Vaporization and compatibility of SiGe radioisotope thermoelectric generators.
The limiting operating temperatures of SiGe thermoelectrics designed for extended operation are set by sublimation process of the elements and by considerations of their compatibility with the surrounding insulating elements. Mass spectrometric Knudsen cell and Langmuir vaporization modes of operation have been utilized in the study of the equilibrium vapor species and in the time evaluation of the sublimation process. Isothermal high-vacuum (1 ntorr) anneals of samples have extended observations to long-time spans. The time variations follow the formation of surface depletion layers due to disproportional rates of sublimation of the various species.