Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

High-Precision Computation and Mathematical Physics

At the present time, IEEE 64-bit floating-point arithmetic is sufficiently accurate for most scientific applications. However, for a rapidly growing body of important scientific computing applications, a higher level of numeric precision is required. Such calculations are facilitated by high-precision software packages that include high-level language translation modules to minimize the conversion effort. This paper presents a survey of recent applications of these techniques and provides some analysis of their numerical requirements. These applications include supernova simulations, climate modeling, planetary orbit calculations, Coulomb n-body atomic systems, scattering amplitudes of quarks, gluons and bosons, nonlinear oscillator theory, Ising theory, quantum field theory and experimental mathematics. We conclude that high-precision arithmetic facilities are now an indispensable component of a modern large-scale scientific computing environment.

97 MATHEMATICS AND COMPUTING↗

A Precision, Low-Cost GPS-Based Synchronization Scheme for Improved AM Reception.

This paper describes a highly accurate carrier-frequency synchronization scheme for actively, automatically locking multiple, remotely located AM broadcast transmitters to a common frequency/timing reference source such as GPS. The extremely tight frequency lock (to ~1 part in 109 or better) permits the effective elimination of audible and even sub-audible beats between the local (desired) station s carrier signal and the distant stations carriers, usually received via skywave propagation during the evening and nighttime hours. These carrier-beat components cause annoying modulations of the desired station s audio at the receiver and concurrent distortion of the audio modulation from the distant station(s) and often cause listeners to tune out due to the poor reception quality. Significant reduction or elimination of the beats and related effects will greatly enlarge the effective (interference-limited) listening area of the desired station (from 4 to 10 times as indicated in our tests) and simultaneously reduce the corresponding interference of the local transmitter to the distant stations as well. In addition, AM stereo (CQUAM) reception will be particularly improved by minimizing the phase shifts induced by co-channel interfering signals; HD will also benefit via reduction in beats from analog signals. The automatic frequency-control hardware described is inexpensive ($1-2K), requires no periodic recalibration, has essentially zero long-term drift, and could employ alternate wide-area frequency references of suitable accuracy, including broadcasts from WWVB, LORAN-C, and equivalent sources. The basic configuration of the GPS-disciplined oscillator which solves this problem is extremely simple. The main oscillator is a conventional high-stability quartz-crystal type. To counter long-term drifts, the oscillator is slightly adjusted to track a high-precision source of standard frequency obtained from a specialized GPS receiver (or other source), usually at 10.000 MHz. This very stable local reference frequency is then used as a clock for a standard digitally implemented frequency synthesizer, which is programmed to generate the specific (AM broadcast) transmitter carrier frequency desired. The stability of the disciplining source, typically ~ 1 part in 109 to 1011, is thus transferred to the final AM transmitter carrier output frequency. Generally, an AM radio listener during the evening and nighttime hours, and to a lesser extent in the early morning, receives undesired skywave signals from several distant stations as well as the desired local (groundwave) signal. If all of these signals are within about 0.01-0.001 Hz of each other, any resulting carrier beats will be of such long periods that the beats will be effectively suppressed by the action of the receiver s AGC circuitry and thus be unnoticeable to the listener. Many modern, synthesizer-based transmitters can directly lock to the precision disciplined 10-MHz source, while older units usually require references at either1 e, 2 e, or 4 e the final frequency. In these latter cases, the existing transmitter crystal can usually be satisfactorily pulled via injection locking. The effectiveness of the synchronization concept to reduce interference effects was demonstrated in a laboratory test setup. Many hours of careful subjective listening were conducted, with the two interfering units both precisely on-frequency with the main unit (synchronous operation) and with the two interferers at various frequency offsets, from below 1 Hz to above 10 Hz.

42 ENGINEERING↗

Recent Advances in Precision Clock Synchronization Protocols for Power Grid Control Systems

With the advent of a new Precision Time Protocol specification, new opportunities abound for clock synchronization possibilities within power grid control systems. The third iteration of the Institute of Electrical and Electronics Engineers Standard 1588 specification provides several new features specifically aimed at complex, wide-area deployments in which situational awareness and control require precise time agreement. This paper describes the challenges faced by existing technology, introduces the new time distribution specification, and provides examples to explain how it represents a game-changing innovation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dissecting Critical Factors for Electrochemical CO 2 Reduction on Atomically Precise Au Nanoclusters

Here, this work investigates the critical factors impacting electrochemical CO 2 reduction reaction (CO 2 RR) using atomically precise Au nanoclusters (NCs) as electrocatalysts. First, the influence of size on CO 2 RR is studied by precisely controlling NC size in the 1–2.5 nm regime. We find that the electrocatalytic CO partial current density increases for smaller NCs, but the CO Faradaic efficiency (FE) is not directly associated with the NC size. This indicates that the surface-to-volume ratio, i.e. the population of active sites, is the dominant factor for determining the catalytic activity, but the selectivity is not directly impacted by size. Second, we compare the CO 2 RR performance of Au 38 isomers (Au 38 Q and Au 38 T) to reveal that structural rearrangement of identical size NCs can lead to significant changes in both CO 2 RR activity and selectivity. Au 38 Q shows higher activity and selectivity towards CO than Au 38 T, and density functional theory (DFT) calculations reveal that the average formation energy of the key *COOH intermediate on the proposed active sites is significantly lower on Au 38 Q than Au 38 T. These results demonstrate how the structural isomerism can impact stabilization of reaction intermediates as well as the overall CO 2 RR performance of identical size Au NCs. Overall, this work provides important structure–property relationships for tailoring the NCs for CO 2 RR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision genome editing in plants using gene targeting and prime editing: existing and emerging strategies

Precise modification of plant genomes, such as seamless insertion, deletion, or replacement of DNA sequences at a predefined site, is a challenging task. Gene targeting (GT) and prime editing are currently the best approaches for this purpose. However, these techniques are inefficient in plants, which limits their applications for crop breeding programs. Recently, substantial developments have been made to improve the efficiency of these techniques in plants. Several strategies, such as RNA donor templating, chemically modified donor DNA template, and tandem-repeat homology-directed repair, are aimed at improving GT. Additionally, improved prime editing gRNA design, use of engineered reverse transcriptase enzymes, and splitting prime editing components have improved the efficacy of prime editing in plants. These emerging strategies and existing technologies are reviewed along with various perspectives on their future improvement and the development of robust precision genome editing technologies for plants.

59 BASIC BIOLOGICAL SCIENCES↗

Panning for gold: Enhancing the precision of sensitivity test data

Sensitivity tests apply a range of stimulus values to experimental subjects and record binary responses in order to estimate the distribution of threshold values in the subject population, where thresholds delineate responses from nonresponses. In many applications, such as explosives engineering, individual tests are expensive and are conducted in small runs. Scarcity of data results in nonexistence of estimates, or estimates with low precision. Here, we discuss various methods, such as combining test runs, covariate analysis, and penalized maximum likelihood, for enhancing precision and “mining more gold” from expensive test results.

97 MATHEMATICS AND COMPUTING↗

Atomically Precise Nanoclusters as Co‐Catalysts for Light‐Activated Microswimmer Motility

Microswimmers are self-propelled particles that navigate fluid environments, offering significant potential for applications in environmental pollutant decomposition, biosensing, and targeted drug delivery. Their performance relies on engineered catalytic surfaces. Gold nanoclusters (AuNCs), with atomically precise structures, tunable optical properties, and high surface area-to-volume ratio, provide a new optimal catalyst for enhancing microswimmer propulsion. Unlike bulk gold or nanoparticles, AuNCs may deliver tunable photocatalytic activity and increased catalytic specificity, making them ideal co-catalysts for hybrid microswimmers. For the first time, this study combines AuNCs with TiO 2 /Cr 2 O 3 Janus microswimmers, combining the unique properties of both materials. This hybrid system capitalizes on the tuned optical properties of AuNCs and their role as co-catalysts with TiO 2 , driving enhanced photocatalytic performance under ultraviolet (UV) excitation. Using motion analysis, it is shown that the AuNC-microswimmers exhibit significantly greater propulsion and mean squared displacement (MSD) as compared to controls. These findings suggest that the integration of nanoclusters with semiconductor materials enables state of the art, light-switchable microswimmers. These AuNC-microswimmer systems may thus offer new opportunities for environmental catalysis and other applications, providing precise control over catalytic and motile behaviors at the microscale.

36 MATERIALS SCIENCE↗

High precision control and deep learning-based corn stand counting algorithms for agricultural robot

This paper presents high precision control and deep learning-based corn stand counting algorithms for a low-cost, ultra-compact 3D printed and autonomous field robot for agricultural operations. Currently, plant traits, such as emergence rate, biomass, vigor, and stand counting, are measured manually. This is highly labor-intensive and prone to errors. The robot, termed TerraSentia, is designed to automate the measurement of plant traits for efficient phenotyping as an alternative to manual measurements. In this paper, we formulate a Nonlinear Moving Horizon Estimator that identifies key terrain parameters using onboard robot sensors and a learning-based Nonlinear Model Predictive Control that ensures high precision path tracking in the presence of unknown wheel-terrain interaction. Moreover, we develop a machine vision algorithm designed to enable an ultra-compact ground robot to count corn stands by driving through the fields autonomously. The algorithm leverages a deep network to detect corn plants in images, and a visual tracking model to re-identify detected objects at different time steps. We collected data from 53 corn plots in various fields for corn plants around 14 days after emergence (stage V3 - V4). The robot predictions have agreed well with the ground truth with C robot =1.02×C human -0.86 and a correlation coefficient R=0.96. The mean relative error given by the algorithm is -3.78%, and the standard deviation is 6.76%. These results indicate a first and significant step towards autonomous robot-based real-time phenotyping using low-cost, ultra-compact ground robots for corn and potentially other crops.

97 MATHEMATICS AND COMPUTING↗

Multi-physics melt pool modeling and process optimization for laser direct energy deposition of Nb-based refractory C103: Defect formation, geometric precision, and process mapping

Recent developments in additive manufacturing (AM) technology have reignited interest in the fabrication of the Nb-based refractory C103 alloy offering solutions to the challenges posed by traditional manufacturing methods. However, the limited numerical and experimental studies on laser direct energy deposition (DED) of C103 have hindered the understanding of the relationships between process parameters and build quality. This has made it challenging to consistently produce parts with the desired quality and microstructure suitable for critical applications. In this study, we focus on optimizing the laser DED process for C103 by employing a hybrid approach that combines experimental techniques and computational fluid dynamics (CFD). This approach facilitates the development of process maps for defect detection and geometric precision. To achieve this, multi-layer C103 samples were fabricated using laser DED under various process parameters, enabling the creation of a process map for defect detection. Additionally, a multi-physics, multiphase simulation framework was developed within a high-performance computing (HPC) environment to establish process maps for geometric precision. Using these process maps, printability windows were identified for achieving both the desired geometric accuracy and defect-free prints. It was observed that prints with a power-to-velocity (P/V) ratio close to unity resulted in defect-free outcomes. This study provides a foundation for reducing design lead time and rejected parts, ultimately optimizing the laser DED process for C103.

Defect formation and geometric precision↗

Precision timing measurements for high energy photons

Particle colliders operating at high luminosities present challenging environments for high energy physics event reconstruction and analysis. We discuss how timing information, with a precision on the order of 10 ps, can aid in the reconstruction of physics events under such conditions. We present calorimeter based timing measurements from test beam experiments in which we explore the ultimate timing precision achievable for high energy photons or electrons of 10 GeV and above. Using a prototype calorimeter consisting of a 1.7×1.7×1.7 cm 3 lutetium–yttrium oxyortho-silicate (LYSO) crystal cube, read out by micro-channel plate photomultipliers, we demonstrate a time resolution of 33.5±2.1 ps for an incoming beam energy of 32 GeV. In a second measurement, using a 2.5×2.5×20 cm 3 LYSO crystal placed perpendicularly to the electron beam, we achieve a time resolution of 59±11 ps using a beam energy of 4 GeV. We also present timing measurements made using a shashlik-style calorimeter cell made of LYSO and tungsten plates, and demonstrate that the apparatus achieves a time resolution of 54±5 ps for an incoming beam energy of 32 GeV.

43 PARTICLE ACCELERATORS↗

Assessing the Impact of Measurement Precision on Metabolite Identification Probability in Multidimensional Mass Spectrometry-Based, Reference-Free Metabolomics

Identification of compounds with minimal ambiguity remains a central challenge in mass spectrometry-based metabolomics. Conventional compound identification relies on comparing analytical signatures (e.g., mass-to-charge ratio, collision cross section, tandem mass spectra) against reference data obtained from measurements of authentic chemical standards. The breadth of annotatable compounds using this approach is necessarily limited by availability of authentic standards, analytical throughput, and resolving power of the separations that underly the measurements. The maturation of computational methods, both theory-driven and artificial intelligence/machine learning-based, for prediction of various molecular properties relevant to multidimensional mass spectrometry measurements has opened the door to a new “reference-free” paradigm of compound annotation. Through augmenting existing reference data for molecular properties with computational predictions, the universe of identifiable chemical species can be expanded significantly beyond its current limits. An unexplored aspect of this novel approach is understanding how to gauge confidence in resulting annotations, especially as the compound search space is expanded. Intuitively, the confidence of a compound annotation is related to the inherent discriminatory power of the molecular properties used for identification, as well as the precision with which the properties are measured or predicted. In this work, we characterize this relationship between measurement precision and identification probability in a systematic and quantitative fashion for a defined region of chemical space that includes organic small molecule metabolites. Importantly, this work establishes a framework for conducting metabolite identification probability analysis that enables others to quantify this relationship for their own compounds and properties of interest.

Metabolite Identification↗

Mixed Precision Fermi-Operator Expansion on Tensor Cores from a Machine Learning Perspective

Here we present a second-order recursive Fermi-operator expansion scheme using mixed precision floating point operations to perform electronic structure calculations using tensor core units. A performance of over 100 teraFLOPs is achieved for half-precision floating point operations on Nvidia’s A100 tensor core units. The second-order recursive Fermi-operator scheme is formulated in terms of a generalized, differentiable deep neural network structure, which solves the quantum mechanical electronic structure problem. We demonstrate how this network can be accelerated by optimizing the weight and bias values to substantially reduce the number of layers required for convergence. We also show how this machine learning approach can be used to optimize the coefficients of the recursive Fermi-operator expansion to accurately represent the fractional occupation numbers of the electronic states at finite temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precise Colloidal Plasmonic Photocatalysts Constructed by Multistep Photodepositions

Natural photosynthesis relies on a sophisticated charge transfer pathway among multiple components with precise spatial, energetic, and temporal organizations in the aqueous environment. It continues to inspire and challenge the design and fabrication of artificial multicomponent colloidal nanostructures for solar-to-fuel conversion. Herein, we introduce a plasmonic photocatalyst synthesized with colloidal methods with five integrated components including cocatalysts installed in orthogonal locations. The precise deposition of individual inorganic components on an Au/TiO 2 nanodumbell nanostructure is enabled by photoreduction and photo-oxidation, which selectively occurs at the TiO 2 tip sites and Au lateral sites, respectively. Under visible-light irradiation, the photocatalyst exhibited activity of oxygen evolution from water without scavengers. Here, we demonstrate that each component is essential for improving the photocatalytic performance. In addition, mechanistic studies suggest that the photocatalytic reaction requires combining the hot charge carriers derived from exciting both the d-sp interband transition and the localized surface plasmon resonance of Au.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improving statistical precision in Monte Carlo samples with negative weights via reweighting and uncertainty quantification

High statistical precision is critical for Monte Carlo (MC) samples in high energy physics and is degraded by negatively weighted events. This paper investigates a procedure to learn the relationship between the negative and positive weight distributions of any sample, allowing the reduction of statistical uncertainty by reweighting kinematically equivalent events with the same sign. A robust uncertainty quantification method is required for the practical application of such method. Two methods for the estimation of the reweighting uncertainty are developed: one at the event and another one at the final observable level. The latter method is strongly favored. The gains in statistical precision are then quantified. The method is demonstrated on Sherpa vector boson plus jets samples when using all generated events and when restricted to the signal region of a mock analysis. It is demonstrated to significantly reduce stochastic behavior in sparse MC samples while decreasing the overall uncertainty with a sufficiently well-known reweighting function.

Monte Carlo methods↗

High-speed raster-scanning synchrotron serial microcrystallography with a high-precision piezo-scanner

The Frontier Microfocus Macromolecular Crystallography (FMX) beamline at the National Synchrotron Light Source II with its 1 µm beam size and photon flux of 3 × 10 12 photons s −1 at a photon energy of 12.66 keV has reached unprecedented dose rates for a structural biology beamline. The high dose rate presents a great advantage for serial microcrystallography in cutting measurement time from hours to minutes. To provide the instrumentation basis for such measurements at the full flux of the FMX beamline, a high-speed, high-precision goniometer based on a unique XYZ piezo positioner has been designed and constructed. The piezo-based goniometer is able to achieve sub-100 nm raster-scanning precision at over 10 grid-linepairs s −1 frequency for fly scans of a 200 µm-wide raster. The performance of the scanner in both laboratory and serial crystallography measurements up to the maximum frame rate of 750 Hz of the Eiger 16M's 4M region-of-interest mode has been verified in this work. This unprecedented experimental speed significantly reduces serial-crystallography data collection time at synchrotrons, allowing utilization of the full brightness of the emerging synchrotron radiation facilities.

43 PARTICLE ACCELERATORS↗

Evaluating Precision of Measured Radionuclide Ambient Air Concentrations

According to AIRNET – Quality Assurance Project Plan for the Radiological Air Sampling Network, SOP-5140, Revision 2 (to become EPC-CP-PIP-5140): “The regulation 40 CFR Part 61.93 requires that the system be able to readily detect a dose of 1.0 mrem above background. Following statistical principles and assuming 95% confidence for such a measurement, we require that 95% of all measurements must fall within two standard deviations of the mean. This represents the minimum acceptable precision for decision making.” An independent assessment of the Rad-NESHAP program completed in early 2019 found that no documentation existed proving that the Airnet data meets the precision defined above. Therefore, to address this particular finding, Airnet concentration data was pulled from the Environmental Information Management (EIM), a cloud-based database maintained by Locus Technologies, for analysis.

54 ENVIRONMENTAL SCIENCES↗

A Platform Technology for High-throughput Atomically Precise Manufacturing: Mechatronics at the Atomic Scale

The main objective of this project is to invent the necessary enabling technologies for high throughput atomically precise manufacturing (APM). APM is an emerging technology that refers to any manufacturing capability that enables fabrication of atomically precise structures, components, and devices under programmable control. APM will require positional assembly at the atomic and/or molecular scale, as well as at the nano and microscales using hierarchical assembly to create products ranging from nanoscale and quantum devices to macroscale systems and materials. This project builds on the expectation that commercial viability of APM will depend on a high level of parallelism to achieve the required throughput, a capability that currently does not exist. This project is the first attempt to address this key technological bottleneck.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-precision arithmetic in mathematical physics

For many scientific calculations, particularly those involving empirical data, IEEE 32-bit floating-point arithmetic produces results of sufficient accuracy, while for other applications IEEE 64-bit floating-point is more appropriate. But for some very demanding applications, even higher levels of precision are often required. Furthermore, this article discusses the challenge of high-precision computation, in the context of mathematical physics, and highlights what facilities are required to support future computation, in light of emerging developments in computer architecture.

97 MATHEMATICS AND COMPUTING↗