Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Grid Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Grid Integration Studies: Data Requirements, Greening the Grid

A grid integration study is an analytical framework used to evaluate a power system with high penetration levels of variable renewable energy (VRE). A grid integration study simulates the operation of the power system under different VRE scenarios, identifying reliability constraints and evaluating the cost of actions to alleviate those constraints. These VRE scenarios establish where, how much, and over what timeframe to build generation and transmission capacity, ideally capturing the spatial diversity benefits of wind and solar resources. The results help build confidence among policymakers, system operators, and investors to move forward with plans to increase the amount of VRE on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PRIME: a real-time cyber-physical systems testbed: from wide-area monitoring, protection, and control prototyping to operator training and beyond

As the power grid continues to evolve with advanced wide-area monitoring, protection, and control (WAMPAC) algorithms, there is an increasing need for realistic testbed environments with industry-grade software and hardware-in-the-loop (HIL) to perform verification and validation studies. Such testbed environments serve as ideal platforms to perform WAMPAC prototyping, operator training, and also to study the impacts of different types of cyberattack scenarios on the operation of the grid. In this paper, we introduce PRIME (PNNL cybeR physIcal systeMs tEstbed): the testbed that integrates real-time transmission system simulator with commercial industry grade energy management system (EMS) software and remote hardware-in-the-loop (RHIL). PRIME is an end-to-end, modular testbed that allows high-fidelity RHIL experimentation of a power system. We present two detailed case studies (fault location and clearing in transmission system, and operator training) to showcase the capabilities of our PRIME testbed. Finally, we briefly discuss some of the potential limitations of our testbed in terms of scalability and flexibility to setup larger test systems and identify directions for future work to address those limitations.

42 ENGINEERING↗

Coordinated Control of Wind Turbine and Energy Storage System for Reducing Wind Power Fluctuation

This paper proposes a method for the coordinated control of a wind turbine and an energy storage system (ESS). Because wind power (WP) is highly dependent on wind speed, which is variable, severe stability problems can be caused in power systems, especially when the WP has a high penetration level. To solve this problem, many power generation corporations or grid operators have begun using ESSs. An ESS has very quick response and good performance for reducing the impact of WP fluctuation; however, its installation cost is high. Therefore, it is important to design the control algorithm by considering both the ESS capacity and WP fluctuation. Thus, we propose a control algorithm to mitigate the WP fluctuation by using the coordinated control between the wind turbine and the ESS by considering the ESS capacity and the WP fluctuation. Using de-loaded control, according to the WP fluctuation and ESS capacity, we can expand the ESS lifespan and improve grid reliability by avoiding the extreme value of state of charge (SoC) (i.e., 0 or 1 pu). The effectiveness of the proposed method was validated via MATLAB/Simulink by considering a small power system that includes both a wind turbine generator and conventional generators that react to system frequency deviation. We found that the proposed method has better performance in SoC management, thereby improving the frequency regulation by mitigating the impact of the WP fluctuation on the small power system.

17 WIND ENERGY↗

Statistical and Spectral Analysis of Wind Characteristics Relevant to Wind Energy Assessment Using Tower Measurements in Complex Terrain

The main objective of the study was to investigate spatial and temporal characteristics of the wind speed and direction in complex terrain that are relevant to wind energy assessment and development, as well as to wind energy system operation, management, and grid integration. Wind data from five tall meteorological towers located in Western Nevada, USA, operated from August 2003 to March 2008, used in the analysis. The multiannual average wind speeds did not show significant increased trend with increasing elevation, while the turbulence intensity slowly decreased with an increase were the average wind speed. The wind speed and direction were modeled using the Weibull and the von Mises distribution functions. The correlations show a strong coherence between the wind speed and direction with slowly decreasing amplitude of the multiday periodicity with increasing lag periods. The spectral analysis shows significant annual periodicity with similar characteristics at all locations. The relatively high correlations between the towers and small range of the computed turbulence intensity indicate that wind variability is dominated by the regional synoptic processes. Knowledge and information about daily, seasonal, and annual wind periodicities are very important for wind energy resource assessment, wind power plant operation, management, and grid integration.

Belu, Radian↗

Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters

This paper investigates operational techniques to achieve seamless (smooth) microgrid (MG) transitions by dispatching a grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control modes during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worth exploring how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. The results show that the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires that the GFM inverter(s) maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-forming↗

Artificial Intelligence for Energy Systems Cybersecurity

Artificial intelligence and machine learning systems have the potential to influence the future design and implementation of cybersecurity systems for the power grid. These systems may enhance the overall operation of the power system by leveraging and making sense of massive amounts of data. However, we must also understand how AI/ML will need to be protected from cyber threat actors. We discuss the existing insights the NREL team has developed using AI/ML systems and then present resources including ESIF and the Cyber Energy Emulation Platform that can be used to generate training data and insights. We end by offering suggestions on priority research paths for AI in cybersecurity.

artificial intelligence↗

Probabilistic Day-Ahead Forecasting Using an Analog Ensemble Approach for Wind Farm Grid Services

Wind resource assessment and wind power forecasting are used in research and industry to anticipate future power output at scales ranging from individual wind turbines to entire wind farms. Probabilistic day-ahead wind forecasting is useful for anticipating how a wind farm could potentially participate in the day-ahead market by providing upper and lower bounds for expected power generation, thus informing grid operators of its uncertainty. Understanding this uncertainty is part of a larger project focused on building a platform that combines efforts in weather forecasting, aerodynamic and economic modeling to create maximum value of a wind plant to better provide services to the grid. This effort is also known as the Atmosphere to Electrons to Grid (A2E2G) project. One method for producing a probabilistic forecast is through the analog ensemble approach (Delle Monache et al., 2011). This method leverages historical forecasts and their corresponding observations as a training data set from which future forecasts can be made. For some future forecast, the most similar historical forecasts (analogs) are identified on a regular time basis such as once per a 3-hour window. The most similar analogs, based on a metric such as root mean square error (RMSE), are recorded and their corresponding verifying observations are used as an ensemble member for this future forecast. Prior work in this area demonstrates improvements over raw Numerical Weather Prediction (NWP) forecasts and shows skill similar to techniques such as logistic regression and machine learning (Delle Monache et al., 2013; Alessandrini et al., 2015). Here, we take the High-Resolution Rapid Refresh model (HRRR) day-ahead forecast (0-36 hours) to create a probabilistic day-ahead forecast using an analog ensemble approach. The HRRR has an hourly temporal resolution, with a spatial resolution of 3 km. The 12 UTC HRRR model run is downloaded every day for one year from August 2019 - July 2020, with the first 11 months serving as a bank of analogs from which the forecasting algorithm can create a probabilistic forecast. Once downloaded, the original HRRR forecast is temporally interpolated to 5-minutes, aligning with both the temporal resolution of the observations as well as the timescale relevant for day-ahead power forecasts. The forecast is validated at the M2 tower at the Flatirons Campus of the National Renewable Energy Laboratory (NREL) at a typical wind turbine height of 80 m. Variables such as wind speed, wind direction, and turbulence intensity are incorporated into the probabilistic forecast model and weighted according to their relative importance to the forecast. Based on metrics such as mean bias error (MBE), mean absolute error (MAE), and root mean square error, the analog ensemble forecast outperforms the raw HRRR forecast during the testing period of July 2020. Figure 1 illustrates an example day-ahead forecast compared against the verifying observations. The general variability and ramps are captured throughout the day, with potential to further improve the analog ensemble model through machine learning techniques.

numerical weather prediction↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid: Preprint

Power System is a complex system, with an objective to provide power to the customers. The objective is driven by a complex consideration of the secure, economic and resilient operation of the system. With the growing occurrence of extreme events emphasis has been shifted towards making the grid more resilient. However, an economic operation is still a priority for the utilities as well as its customers. Many utilities especially small isolated micro-grids do not emphasize much on an economic and resilient operation, but more on reliability. In this research we focus on striking a balance between economic and resilientoperation, ensuring reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure- and Physics-Preserving Reductions of Power Grid Models

The large size of multiscale, distribution and transmission, power grids hinders fast systemwide estimation and real-time control and optimization of operations. This paper studies graph reduction methods of power grids that are favorable for fast simulations and follow-up applications. While the classical Kron reduction has been successful in reduced order modeling of power grids with traditional, hierarchical design, the selection of reference nodes for the reduced model in a multiscale, distribution and transmission, network becomes ambiguous. In this work we extend the use of the iterative Kron reduction by utilizing the electric grid's graph topology for the selection of reference nodes, consistent with the design features of multiscale networks. Additionally, we propose further reductions by aggregation of coherent subnetworks of triangular meshes, based on the graph topology and network characteristics, in order to preserve currents and build another power-flow equivalent network. Our reductions are achieved through the use of iterative aggregation of subgraphs that include general tree structures, lines, and triangles. Important features of our reduction algorithms include that (i) the reductions are either equivalent to the Kron reduction or otherwise produce a power-flow equivalent network; (ii) due to the mentioned power-flow equivalence, the reduced network can model the dynamic of the swing equations for a lossless, inductive, steady state network; (iii) the algorithms efficiently utilize hash tables to store the sequential reduction steps. The third feature allows for easy reintroduction of detailed models into the reduced, conceptual network and makes the final reduced order model backward compatible with a sequence of intermediate, partially reduced networks with varying resolution---the ordered sequence of iterative reductions corresponds to a sequence of reduced order models. The performance of our graph reduction algorithms and features of the reduced grids are discussed on a real-word transmission and distribution grid. We produce visualizations of the reduced models through open source libraries and release our reduction algorithms with example code and toy data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Padding for the Two-Dimensional Fast Fourier Transform

One-dimensional Fast Fourier Transform (FFT) operations work fastest on grids whose size is divisible by a power of two. Because of this, padding grids (that are not already sized to a power of two) so that their size is the next highest power of two can speed up operations. While this works well for one-dimensional grids, it does not work well for two-dimensional grids. For a two-dimensional grid, there are certain pad sizes that work better than others. Therefore, the need exists to generalize a strategy for determining optimal pad sizes. There are three steps in the FFT algorithm. The first is to perform a one-dimensional transform on each row in the grid. The second step is to transpose the resulting matrix. The third step is to perform a one-dimensional transform on each row in the resulting grid. Steps one and three both benefit from padding the row to the next highest power of two, but the second step needs a novel approach. An algorithm was developed that struck a balance between optimizing the grid pad size with prime factors that are small (which are optimal for one-dimensional operations), and with prime factors that are large (which are optimal for two-dimensional operations). This algorithm optimizes based on average run times, and is not fine-tuned for any specific application. It increases the amount of times that processor-requested data is found in the set-associative processor cache. Cache retrievals are 4-10 times faster than conventional memory retrievals. The tested implementation of the algorithm resulted in faster execution times on all platforms tested, but with varying sized grids. This is because various computer architectures process commands differently. The test grid was 512 512. Using a 540 540 grid on a Pentium V processor, the code ran 30 percent faster. On a PowerPC, a 256x256 grid worked best. A Core2Duo computer preferred either a 1040x1040 (15 percent faster) or a 1008x1008 (30 percent faster) grid. There are many industries that can benefit from this algorithm, including optics, image-processing, signal-processing, and engineering applications.

Dean, Bruce H.↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

DNN-based policies for stochastic AC OPF

We report a prominent challenge to the safe and optimal operation of the modern power grid arises due to growing uncertainties in loads and renewables. Stochastic optimal power flow (SOPF) formulations provide a mechanism to handle these uncertainties by computing dispatch decisions and control policies that maintain feasibility under uncertainty. Most SOPF formulations consider simple control policies such as affine policies that are mathematically simple and resemble many policies used in current practice. Motivated by the efficacy of machine learning (ML) algorithms and the potential benefits of general control policies for cost and constraint enforcement, we put forth a deep neural network (DNN)-based policy that predicts the generator dispatch decisions in real time in response to uncertainty. The weights of the DNN are learnt using stochastic primal–dual updates that solve the SOPF without the need for prior generation of training labels and can explicitly account for the feasibility constraints in the SOPF. The advantages of the DNN policy over simpler policies and their efficacy in enforcing safety limits and producing near optimal solutions are demonstrated in the context of a chance constrained formulation on a number of test cases.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

OpenSolar: Promoting the Openness and Accessibility of Diverse Public Solar Datasets

Observational solar data is the foundation of data-driven research in solar power grid integration and power system operations. Compared to other fields in data science, the openness and accessibility of solar data is lacking, which prevents solar data science from catching up with the emerging trends of data science (e.g., deep learning). In this paper, OpenSolar, a package with both R and Python versions, is developed to enhance the openness and accessibility of publicly available solar datasets. The OpenSolar package provides access to multiple types of solar data, primarily from four datasets: (1) the National Renewable Energy Laboratory (NREL) Solar Power Data for Integration Studies dataset, (2) the NREL Solar Radiation Research Laboratory dataset, (3) the Sheffield Solar-Microgen database, and (4) the Dataport database. Unlike other open solar datasets that only contain meteorological data, the four datasets in the OpenSolar package also contain behind-the-meter power data, sky images, and solar power data with satisfactory temporal and spatial resolution and coverage. The overview, quality-control methods, and potential usage of the datasets, in conjunction with sample code implementing the OpenSolar functions, are described in this paper. The package is expected to assist in bridging the gaps between the research fields of solar energy, power systems, and data science.

14 SOLAR ENERGY↗

Cyber Attack Sequences Generation for Electric Power Grid

Security assessment of cyber-physical energy systems (CPESs) such as the electric power grid is a critical operation to maintain availability, reliability, and quality of service in the presence of persistent threats from malicious cyber actors. Existing security assessment approaches such as penetration testing and red teaming rely on subject matter expert experience and forensic cyber analysis of historical events to perform realistic, threat-informed assessments of CPES defense. CPESs have a large attack surface because of the heterogeneity and complexity of underlying topology, devices, measurements, and vulnerabilities. The aforementioned approaches lead to partial coverage of the attack surface with a large set of unknown but possible exploits. There is a need to automate the CPES attack surface discovery and contextualize it for relevant, highly probable, real-world attack scenarios. We propose a methodology and framework to facilitate the discovery of the CPES attack surface. We present a multilayer attack graph with ranked attack sequences to describe CPES failure scenarios. We present a work-in-progress framework that lists key components to automate the attack modeling and sequence generation. We demonstrate the published National Electric Sector Cybersecurity Organization Resource CPES failure scenario to highlight the trustworthiness of generated attack sequences.

Dutta, Ashutosh↗

Stochastic Home Energy Management Systems with Varying Controllable Resources

This paper studies the performance of a model predictive control (MPC) algorithm in a home energy management system (HEMS) as the set of controllable resources varies and under both a constant and a time-of-use (TOU) electricity price structure. The set of controllable resources includes residentially-owned photovoltaic (PV) panels, a home battery system (HBS), an electric vehicle (EV), and a home heating, ventilation, and air conditioning (HVAC) system. The HEMS optimally schedules the set of controllable resources given user preferences such as indoor thermal comfort and electricity cost sensitivity. The home energy management system is built on a chance constrained, MPC-based algorithm, where the chance constraint ensures the indoor thermal comfort is satisfied with a high probability given uncertainty in the outdoor temperature and solar irradiance forecasts. Simulation results for varying sets of controllable resources under two different electricity price structures demonstrate the variation in the HEMS control with respect to HBS operation, electricity cost, and grid power usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guidelines for Implementing Advanced Distribution Management Systems: Requirements for DMS Integration with DERMS and Microgrids

This guideline focuses on the integration of DMS with DERMS and microgrids connected to the distribution grid by defining generic and fundamental design and implementation principles and strategies. It starts by addressing the current status, objectives, and core functionalities of each system, and then discusses the new challenges and the common principles of DMS design and implementation for integration with DERMS and microgrids to realize enhanced grid operation reliability and quality power delivery to consumers while also achieving the maximum energy economics from the DER and microgrid connections.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Real-Time Operations Manual for the IEEE 118 Bus Transmission Model

This document presents a sample operations manual for the IEEE 118 Bus Model, which is a synthetic test case developed in 1962 from a section of the transmission grid operated by American Electric Power (AEP). The model is one of the most used synthetic test cases for development of power system applications and is referenced by over 9000 papers. However, the model lacks any context for use with real-time energy management system (EMS) applications, including common considerations, such as generator ramp rates, reactive capabilities, operating limits, and other information typically used by power system operators for real-time decision making. This manual divides the IEEE 118 Bus Model into three operating areas, defines various operating limits, and sets recommended operating procedures for responding to a few types of emergency operating conditions. The manual can be used in support of a wide variety of human-in-the-loop evaluation methodologies for new advanced power applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗