Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

SU-F-I-19: MRI Positive Contrast Visualization of Prostate Brachytherapy Seeds Using An Integrated Laplacian-Based Phase Processing

Purpose: To propose a new method that provides a positive contrast visualization of the prostate brachytherapy seeds using the phase information from MR images. Additionally, the feasibility of using the processed phase information to distinguish seeds from calcifications is explored. Methods: A gel phantom was constructed using 2% agar dissolved in 1 L of distilled water. Contrast agents were added to adjust the relaxation times. Four iodine-125 (Eckert & Ziegler SML86999) dummy seeds were placed at different orientations with respect to the main magnetic field (B0). Calcifications were obtained from a sheep femur cortical bone due to its close similarity to human bone tissue composition. Five samples of calcifications were shaped into different dimensions with lengths ranging between 1.2 – 6.1 mm.MR imaging was performed on a 3T Philips Achieva using an 8-channel head coil. Eight images were acquired at eight echo-times using a multi-gradient echo sequence. Spatial resolution was 0.7 × 0.7 × 2 mm, TR/TE/dTE = 20.0/2.3/2.3 ms and BW = 541 Hz/pixel. Complex images were acquired and fed into a two-step processing pipeline: the first includes phase unwrapping and background phase removal using Laplacian operator (Wei et al. 2013). The second step applies a specific phase mask on the resulting tissue phase from the first step to provide the desired positive contrast of the seeds and to, potentially, differentiate them from the calcifications. Results: The phase-processing was performed in less than 30 seconds. The proposed method has successfully resulted in a positive contrast of the brachytherapy seeds. Additionally, the final processed phase image showed difference between the appearance of seeds and calcifications. However, the shape of the seeds was slightly distorted compared to the original dimensions. Conclusion: It is feasible to provide a positive contrast of the seeds from MR images using Laplacian operator-based phase processing.

60 APPLIED LIFE SCIENCES↗

SU-F-J-34: Automatic Target-Based Patient Positioning Framework for Image-Guided Radiotherapy in Prostate Cancer Treatment

Purpose: Current image-guided radiotherapy (IGRT) procedure is bonebased patient positioning, followed by subjective manual correction using cone beam computed tomography (CBCT). This procedure might cause the misalignment of the patient positioning. Automatic target-based patient positioning systems achieve the better reproducibility of patient setup. Our aim of this study was to develop an automatic target-based patient positioning framework for IGRT with CBCT images in prostate cancer treatment. Methods: Seventy-three CBCT images of 10 patients and 24 planning CT images with digital imaging and communications in medicine for radiotherapy (DICOM-RT) structures were used for this study. Our proposed framework started from the generation of probabilistic atlases of bone and prostate from 24 planning CT images and prostate contours, which were made in the treatment planning. Next, the gray-scale histograms of CBCT values within CTV regions in the planning CT images were obtained as the occurrence probability of the CBCT values. Then, CBCT images were registered to the atlases using a rigid registration with mutual information. Finally, prostate regions were estimated by applying the Bayesian inference to CBCT images with the probabilistic atlases and CBCT value occurrence probability. The proposed framework was evaluated by calculating the Euclidean distance of errors between two centroids of prostate regions determined by our method and ground truths of manual delineations by a radiation oncologist and a medical physicist on CBCT images for 10 patients. Results: The average Euclidean distance between the centroids of extracted prostate regions determined by our proposed method and ground truths was 4.4 mm. The average errors for each direction were 1.8 mm in anteroposterior direction, 0.6 mm in lateral direction and 2.1 mm in craniocaudal direction. Conclusion: Our proposed framework based on probabilistic atlases and Bayesian inference might be feasible to automatically determine prostate regions on CBCT images.

60 APPLIED LIFE SCIENCES↗

SU-F-J-43: Positional Variation of Implanted Fiducial Markers Over the Course of Image Guided Radiotherapy for Pancreatic Cancer

Purpose: Pancreas is a soft-tissue organ, implanted fiducials can change positions due to migration or tissue deformation. This study quantified positional variation of fiducials in IGRT for pancreatic cancer. Methods: 20 patients had at least 3 gold fiducials implanted in pancreas under EUS guidance. Patients had 4D-CT simulation for gated treatment. Daily gated OBI kV images (Turebeam) were used for positional alignment with fiducials for total of 25 or 28 fractions. Relative distances among 3 fiducials (d{sub 1–} {sub 2}, d{sub 1–3}, d{sub 2–3}) were measured from 4D-CT end-of-expiration phase bin; and from gated kV images in first, mid, and last fraction (n=180). Results: The median duration between implant and simulation was 11 (range 0–41) days. The median duration between simulation and first fraction was 17 (range 8–24) days. The median relative distance was 12 (range 4–78) mm for d{sub 1–2}, 24 (range 6–80) mm for d{sub 1–3}, and 19 (range 5–63) mm for d{sub 2–3}. The median deviation was 1 mm for d{sub 1–2}, d{sub 1–3}, d{sub 2–3} between simulation and first fraction, first and mid fraction, mid and last fraction (n=180). Two patients (10%) had deviation >= 5 mm (5, 11 mm) between simulation and first fraction. One patient (5%) had deviation >= 5 mm (11 mm) between first and mid fraction. No patient (0%) had deviation >= 5 mm between mid and last fraction. In all 3 cases with deviation >=5 mm, only one fiducial was significantly deviated. No clear evidence that deviation size was associated with time interval between implant and first fraction. Conclusion: Implanted gold fiducials were quite stable over time in their relative positions in pancreas. Our data suggested at least 3 fiducials are needed. In cases that one fiducial was significantly deviated in daily kV images, this fiducial should be excluded in image guidance.

60 APPLIED LIFE SCIENCES↗

SU-F-J-131: Reproducibility of Positioning Error Due to Temporarily Indwelled Urethral Catheter for Urethra-Sparing Prostate IMRT

Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostate at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by post-indwelled CT images.

60 APPLIED LIFE SCIENCES↗

SU-F-J-208: Prompt Gamma Imaging-Based Prediction of Bragg Peak Position for Realistic Treatment Error Scenarios

Purpose: To quantify the accuracy in predicting the Bragg peak position using simulated in-room measurements of prompt gamma (PG) emissions for realistic treatment error scenarios that combine several sources of errors. Methods: Prompt gamma measurements by a knife-edge slit camera were simulated using an experimentally validated analytical simulation tool. Simulations were performed, for 143 treatment error scenarios, on an anthropomorphic phantom and a pencil beam scanning plan for nasal cavity. Three types of errors were considered: translation along each axis, rotation around each axis, and CT-calibration errors with magnitude ranging respectively, between −3 and 3 mm, −5 and 5 degrees, and between −5 and +5%. We investigated the correlation between the Bragg peak (BP) shift and the horizontal shift of PG profiles. The shifts were calculated between the planned (reference) position and the position by the error scenario. The prediction error for one spot was calculated as the absolute difference between the PG profile shift and the BP shift. Results: The PG shift was significantly and strongly correlated with the BP shift for 92% of the cases (p<0.0001, Pearson correlation coefficient R>0.8). Moderate but significant correlations were obtained for all cases that considered only CT-calibration errors and for 1 case that combined translation and CT-errors (p<0.0001, R ranged between 0.61 and 0.8). The average prediction errors for the simulated scenarios ranged between 0.08±0.07 and 1.67±1.3 mm (grand mean 0.66±0.76 mm). The prediction error was moderately correlated with the value of the BP shift (p=0, R=0.64). For the simulated scenarios the average BP shift ranged between −8±6.5 mm and 3±1.1 mm. Scenarios that considered combinations of the largest treatment errors were associated with large BP shifts. Conclusion: Simulations of in-room measurements demonstrate that prompt gamma profiles provide reliable estimation of the Bragg peak position for complex error scenarios. Yafei Xing and Luiza Bondar are funded by BEWARE grants from the Walloon Region. The work presents simulations results for a prompt gamma camera prototype developed by IBA.

60 APPLIED LIFE SCIENCES↗

How the CCA-Adding Enzyme Selects Adenine over Cytosine at Position 76 of tRNA

CCA-adding enzymes [ATP(CTP):tRNA nucleotidyltransferases] add CCA onto the 3{prime} end of transfer RNA (tRNA) precursors without using a nucleic acid template. Although the mechanism by which cytosine (C) is selected at position 75 of tRNA has been established, the mechanism by which adenine (A) is selected at position 76 remains elusive. Here, we report five cocrystal structures of the enzyme complexed with both a tRNA mimic and nucleoside triphosphates under catalytically active conditions. These structures suggest that adenosine 5{prime}-monophosphate is incorporated onto the A76 position of the tRNA via a carboxylate-assisted, one-metal-ion mechanism with aspartate 110 functioning as a general base. The discrimination against incorporation of cytidine 5{prime}-triphosphate (CTP) at position 76 arises from improper placement of the {alpha} phosphate of the incoming CTP, which results from the interaction of C with arginine 224 and prevents the nucleophilic attack by the 3{prime} hydroxyl group of cytidine75.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of a monoclonal antibody specific to California serogroup orthobunyaviruses and development as a chimeric immunoglobulin M-positive control in human diagnostics

ABSTRACT California serogroup viruses (CSGVs) of medical importance in the United States include La Crosse virus, Jamestown Canyon virus (JCV), California encephalitis virus, and snowshoe hare virus. Current diagnosis of CSGVs relies heavily on serologic techniques for detecting immunoglobulin M (IgM), an indication of a recent CSGV infection. However, human-positive control sera reactive to viruses in the serogroup are scarce because detection of recent infections is rare. Here, we describe the development of new murine monoclonal antibodies (MAbs) reactive to CSGVs and the engineering of a human-murine chimeric antibody by combining the variable regions of the broadly CSGV cross-reactive murine MAb, 3-3B6/2-3B2 and the constant region of the human IgM. MAb 3-3B6/2-3B2 recognizes a tertiary epitope on the Gn/Gc heterodimer, and epitopes important in JCV neutralization were mapped to the Gc glycoprotein. This engineered human IgM constitutively expressed in a HEK-293 stable cell line can replace human-positive control sera in diagnostic serological techniques such as IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA). Compared to the parent murine MAbs, the human-chimeric IgM antibody had identical serological activity to CSGVs in ELISA and demonstrated equivalent reactivity compared to human immune sera in the MAC-ELISA. Importance Orthobunyaviruses in the California serogroup cause severe neurological disease in children and adults. While these viruses are known to circulate widely in North America, their occurrence is rare. Serological testing for CSGVs is hindered by the limited availability and volumes of human-positive specimens needed as controls in serologic assays. Here, we described the development of a murine monoclonal antibody cross-reactive to CSGVs engineered to contain the variable regions of the murine antibody on the backbone of human IgM. The chimeric IgM produced from the stably expressing HEK293 cell line was evaluated for use as a surrogate human-positive control in a serologic diagnostic test.

Microbiology↗

Demonstration of event position reconstruction based on diffusion in the NEXT-white detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift dis tance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high and low-energy events. Using point-like energy deposits from 83m Kr calibration electron captures (E ~ 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias < 1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E ≥ 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q ββ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position-Enhanced Gradient Attack (PEGA) on Medical Language Models

Federated Learning (FL) enables collaborative training of language models on sensitive clinical notes without sharing the data. However, this paradigm is vulnerable to gradient inversion attacks that can reconstruct private data from shared gradients. We find that state-of-the-art attacks are less effective in the medical domain, failing to overcome the unique challenges posed by its specialized vocabulary and unstructured format. To address this, we introduce the Position-Enhanced Gradient Attack (PEGA), a novel attack that makes gradients position-aware by optimizing token and position embeddings simultaneously. PEGA employs two key innovations: a periodic sorting of positional embeddings to resolve token order ambiguity and a late-stage embedding replacement strategy to correct hard-to-recover critical tokens. To evaluate the leakage of sensitive data more directly, we also propose the Unified PHI-Recall (UPHI), a new metric measuring the recovery of Protected Health Information. Experiments on the MIMIC-III dataset show that PEGA significantly outperforms leading attacks like TAG and LAMP, particularly in its ability to reconstruct identifiable patient information, exposing a more severe and nuanced privacy risk in federated medical NLP.

Xu, Nuo [University of Minnesota]↗

Extreme Fast Charging: Effect of Positive Electrode Material on Crosstalk

Extreme fast charging (XFC) is a key requirement for the adoption of battery-based electric vehicles by the transportation sector. However, XFC has been shown to accelerate degradation, causing the capacity, life, and safety of batteries to deteriorate. We tested cells containing five positive electrode chemistries, LFP (olivine structure), LMO (spinel), LCO (layered), NMC811 (layered) and NCA (layered), using fast-charging protocols. After testing, the negative electrodes from cells containing positive electrodes crystallizing with a layered structure were found to have more lithium deposited on their surfaces. Further, those crystallizing with a layered structure also tended to have a larger increase in impedance than those crystallizing with a spinel or olivine structure. Characterization of the negative electrodes by X-ray photoelectron spectroscopy showed that using the concentrations of LiF and Li x PO y F z as metrics, the concentration of LiF in the SEI from the cell with different positive electrodes is LFP > LMO > LCO ~ NMC811 > NCA; and for Li x PO y F z , the order is LMO > LFP > NCA > NMC811 > LCO. Clearly, the positive-electrode material was influencing the amounts of these materials formed.

25 ENERGY STORAGE↗

Examining Performance Loss Mechanisms in Lithium-Ion Batteries with the High-Voltage Mn-Rich Spinel Positive Electrodes

The high-voltage spinel, with the nominal composition of LiNi 0.5-x Mn 1.5+x O 4 (LNMO), could be a sustainable alternative to the layered-oxide positive electrodes used in lithium-ion batteries. However, commercial acceptance has been limited as LNMO cells display rapid performance loss during cycling. To examine reasons for this loss we prepared cells with LNMO-based positive and either graphite or lithium titanate (LTO) based negative electrodes. Our initial cells displayed high impedance and rapid impedance rise during cycling. Adding single walled carbon nanotubes in the positive lowered initial cell impedance but impedance increased during cycling because of coating delamination from the Al foil. Using a primed Al current collector solved the delamination problem: cells with this current collector showed only a small impedance rise. Regarding capacity, cells with the LTO negative showed higher initial capacities and smaller fade. Our data indicate that cell capacity retention is determined by reduction reactions at the negative electrode that lower capacity and oxidation reactions at the positive electrode that increase capacity: both types of reactions deplete the cell electrolyte during extended cycling. All things considered, species generated at high voltages, either in the electrolyte or at the LNMO electrode, drive cell capacity fade.

25 ENERGY STORAGE↗

The impact of kidney function on Alzheimer’s disease blood biomarkers: implications for predicting amyloid-β positivity

Impaired kidney function has a potential confounding effect on blood biomarker levels, including biomarkers for Alzheimer’s disease (AD). Given the imminent use of certain blood biomarkers in the routine diagnostic work-up of patients with suspected AD, knowledge on the potential impact of comorbidities on the utility of blood biomarkers is important. We aimed to evaluate the association between kidney function, assessed through estimated glomerular filtration rate (eGFR) calculated from plasma creatinine and AD blood biomarkers, as well as their influence over predicting Aβ-positivity. We included 242 participants from the Translational Biomarkers in Aging and Dementia (TRIAD) cohort, comprising cognitively unimpaired individuals (CU; n = 124), mild cognitive impairment (MCI; n = 58), AD dementia (n = 34), and non-AD dementia (n = 26) patients all characterized by [ 18 F] AZD-4694. Plasma samples were analyzed for Aβ42, Aβ40, glial fibrillary acidic protein (GFAP), neurofilament light chain (NfL), tau phosphorylated at threonine 181 (p-tau181), 217 (p-tau217), 231 (p-tau231) and N-terminal containing tau fragments (NTA-tau) using Simoa technology. Kidney function was assessed by eGFR in mL/min/1.73 m 2 , based on plasma creatinine levels, age, and sex. Participants were also stratified according to their eGFR-indexed stages of chronic kidney disease (CKD). We evaluated the association between eGFR and blood biomarker levels with linear models and assessed whether eGFR provided added predictive value to determine Aβ-positivity with logistic regression models. Biomarker concentrations were highest in individuals with CKD stage 3, followed by stages 2 and 1, but differences were only significant for NfL, Aβ42, and Aβ40 (not Aβ42/Aβ40). All investigated biomarkers showed significant associations with eGFR except plasma NTA-tau, with stronger relationships observed for Aβ40 and NfL. However, after adjusting for either age, sex or Aβ-PET SUVr, the association with eGFR was no longer significant for all biomarkers except Aβ40, Aβ42, NfL, and GFAP. When evaluating whether accounting for kidney function could lead to improved prediction of Aβ-positivity, we observed no improvements in model fit (Akaike Information Criterion, AIC) or in discriminative performance (AUC) by adding eGFR to a base model including each plasma biomarker, age, and sex. While covariates like age and sex improved model fit, eGFR contributed minimally, and there were no significant differences in clinical discrimination based on AUC values. We found that kidney function seems to be associated with AD blood biomarker concentrations. However, these associations did not remain significant after adjusting for age and sex, except for Aβ40, Aβ42, NfL, and GFAP. While covariates such as age and sex improved prediction of Aβ-positivity, including eGFR in the models did not lead to improved prediction for any biomarker. Our findings indicate that renal function, within the normal to mild impairment range, does not seem to have a clinically relevant impact when using highly accurate blood biomarkers, such as p-tau217, in a biomarker-supported diagnosis.

60 APPLIED LIFE SCIENCES↗

False-Positive Results and Incidental Findings with Annual CT or PET/CT Surveillance in Asymptomatic Patients with Resected Stage III Melanoma

Objective: The aim of this study was to quantify false-positive and incidental findings from annual surveillance imaging in asymptomatic, American Joint Committee on Cancer stage III melanoma patients. Methods: This was a cohort study of patients treated at Melanoma Institute Australia (2000–2015) with baseline computed tomography (CT) or positron emission tomography (PET)/CT imaging and at least two annual surveillance scans. False-positives were defined as findings suspicious for melanoma recurrence that were not melanoma, confirmed by histopathology, subsequent imaging, or clinical follow-up, while incidental findings were defined as non-melanoma-related findings requiring further action. Outcomes of incidental findings were classified as ‘benign’ if they resolved spontaneously or were not seriously harmful; ‘malignant’ if a second malignancy was identified; or ‘other’ if potentially harmful. Results: Among 154 patients, 1022 scans were performed (154 baseline staging, 868 surveillance) during a median follow-up of 85 months (interquartile range 56–112); 57 patients (37%) developed a recurrence. For baseline and surveillance imaging, 124 false-positive results and incidental findings were identified in 81 patients (53%). The frequency of these findings was 5–14% per year, and an additional 181 tests, procedures, and referrals were initiated to investigate these findings. The diagnosis was benign in 109 findings of 124 findings (88%). Fifteen patients with a benign finding underwent an unnecessary invasive procedure. Surveillance imaging identified distant metastases in 20 patients (13%). Conclusion: False-positive results and incidental findings occur in at least half of all patients undergoing annual surveillance imaging, and the additional healthcare use is substantial. These findings persist over time. Clinicians need to be aware of these risks and discuss them with patients, alongside the expected benefits of surveillance imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns in the Use of Axillary Operations for Patients with Node-Positive Breast Cancer After Neoadjuvant Chemotherapy: A National Cancer Database (NCDB) Analysis

Background: The American College of Surgeons Oncology Group (ACOSOG) Z1071 and Sentinel Neoadjuvant (SENTINA) trials of sentinel node biopsy for node-positive breast cancer treated with neoadjuvant chemotherapy (NAC) demonstrated false-negative rates that varied on the basis of surgical technique. This study evaluated trends in axillary operations before and after publication of these trials. Methods: This study analyzed patients from National Cancer Database (NCDB) with clinical T0 through T4, N1 and N2, M0 breast cancer who received NAC from 1 January 2012 to 31 December 2015 and sentinel lymph node biopsy (SNB) or axillary lymph node dissection (ALND). The patients were divided into the following groups: SNB, ALND, and (SNB + ALND). Results: Of the 32,036 evaluable patients identified in this study. 5565 had SNB, 19,930 had ALND, and 6541 had SNB + ALND. Compared with the ALND group, the SNB group was younger, had more invasive ductal cancers, and had lower clinical T- and N-stage disease (p < 0.001). The patients in the SNB group had a higher rate of estrogen receptor-positive and triple-negative breast cancers, but a lower rate of human epidermal growth factor receptor 2 (HER2)-positive cancer (p < 0.001). The nodal pathologic complete response (PCR) rate, defined as no residual invasive cancer, was 66.5% in the SNB group and 33.1% in the ALND group. Since 2013, the rate of ALND has decreased from 88.7 to 77.1% in both community and academic institutions (p < 0.001). Conclusion: Since publication of the ACOSOG Z1071 and SENTINA trials, the national rates of ALND in node positive breast cancer treated with NAC have decreased despite reported false-negative SNB rates and lack of prospective outcome data regarding the oncologic safety of ALND omission.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neoadjuvant Endocrine Therapy Versus Neoadjuvant Chemotherapy in Node-Positive Invasive Lobular Carcinoma

Background: Neoadjuvant chemotherapy (NACT) is often recommended for patients with node-positive invasive lobular carcinoma (ILC) despite unclear benefit in this largely hormone receptor-positive (HR+) group. We sought to compare overall survival (OS) between patients with node-positive ILC who received neoadjuvant endocrine therapy (NET) and those who received NACT. Methods: Women with cT1–4c, cN1–3 HR+ ILC in the National Cancer Data Base (2004–2014) who underwent surgery following neoadjuvant therapy were identified. Kaplan–Meier curves and Cox proportional hazards modeling were used to estimate unadjusted and adjusted overall survival (OS), respectively. Results: Of the 5942 patients in the cohort, 855 received NET and 5087 received NACT. NET recipients were older (70 vs. 54 years) and had more comorbidities (Charlson–Deyo score ≥ 1: 21.1% vs. 11.5%), lower cT classification (cT3–4: 44.2% vs. 51.0%), lower rates of mastectomy (72.5% vs. 82.2%), lower rates of pathologic complete response (0% vs. 2.5%), and lower rates of postlumpectomy (73.2% vs. 91.0%) and postmastectomy (60.0% vs. 80.8%) radiation versus NACT recipients (all p < 0.001). NACT recipients had higher unadjusted 10-year OS versus NET recipients (57.9% vs. 36.0%), but after adjustment, there was no significant difference in OS between the two groups (p = 0.10). Conclusions: Patients with node-positive ILC who received NET presented with smaller tumors, older age, and greater burden of comorbidities versus NACT recipients but had similar adjusted OS. While there is evidence from clinical trials supporting efficacy of NET in HR+ breast cancer, our findings suggest the need for further, histology-specific investigation regarding the optimal inclusion and sequence of endocrine therapy and chemotherapy in ILC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Creation of Mice Bearing a Partial Duplication of HPRT Gene Marked with a GFP Gene and Detection of Revertant Cells In Situ as GFP-Positive Somatic Cells

It is becoming clear that apparently normal somatic cells accumulate mutations. Such accumulations or propagations of mutant cells are thought to be related to certain diseases such as cancer. To better understand the nature of somatic mutations, we developed a mouse model that enables in vivo detection of rare genetically altered cells via GFP positive cells. The mouse model carries a partial duplication of 3’ portion of X-chromosomal HPRT gene and a GFP gene at the end of the last exon. In addition, although HPRT gene expression was thought ubiquitous, the expression level was found insufficient in vivo to make the revertant cells detectable by GFP positivity. To overcome the problem, we replaced the natural HPRT -gene promoter with a CAG promoter. In such animals, termed HPRT-dup-GFP mouse, losing one duplicated segment by crossover between the two sister chromatids or within a single molecule of DNA reactivates gene function, producing hybrid HPRT-GFP proteins which, in turn, cause the revertant cells to be detected as GFP-positive cells in various tissues. Frequencies of green mutant cells were measured using fixed and frozen sections (liver and pancreas), fixed whole mount (small intestine), or by means of flow cytometry (unfixed splenocytes). The results showed that the frequencies varied extensively among individuals as well as among tissues. X-ray exposure (3 Gy) increased the frequency moderately (~2 times) in the liver and small intestine. Further, in two animals out of 278 examined, some solid tissues showed too many GFP-positive cells to score (termed extreme jackpot mutation). Present results illustrated a complex nature of somatic mutations occurring in vivo. While the HPRT-dup-GFP mouse may have a potential for detecting tissue-specific environmental mutagens, large inter-individual variations of mutant cell frequency cause the results unstable and hence have to be reduced. This future challenge will likely involve lowering the background mutation frequency, thus reducing inter-individual variation

Science & Technology - Other Topics↗

Drone Strikes: An Overview, Articulation and Assessment of the United States' Position Under International Law

The United States unmanned aerial vehicle (UAV or drone) program has origins dating back to the early part of the twentieth century. From crude target tug vessels to sophisticated Hellfire missile delivery vehicles, United States drones have undergone a gradual metamorphosis from their early days as an obscure technology to their present status as a center piece in global counterterrorism operations. Since the attacks of September 11, 2001 and the onset of the war on terror, weaponized drones have effectuated thousands of strikes in numerous countries spanning multiple continents in the course of a claimed non-international armed conflict with “al-Qaida, the Taliban and their associated forces.” A plethora of scholarship has evaluated aspects of the legal underpinnings of the nearly two decade-long campaign and its utilization of weaponized drones. This article builds upon that analytic foundation to date in articulating and assessing the present United States legal position vis-à-vis its lethal drone strike operations under relevant principles of international law. It identifies numerous instances in which the United States position departs to varying degree from general international understanding and concludes that, in the aggregate, these deviations are sufficient to pose serious international rule of law concerns. It then goes further to briefly consider possible alternatives for mitigating these concerns, but notes their challenges given prevailing political circumstances. The article is organized in four parts. Part I provides a condensed history of the development of drone capabilities in the United States and their use under the administrations of Clinton, Bush, Obama and Trump. Part II surveys principles of international law relevant to the analysis of United States drone strike operations abroad. Part III draws on key government documents to articulate the United States legal position, including its jus ad bellum justifications and stance on international humanitarian and international human rights law principles, and offers a legal assessment. Part IV briefly considers and evaluates possible alternatives to the present position.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Energy Sector Position, Navigation, and Time Cybersecurity Profile

The Pacific Northwest National Laboratory has developed this positioning, navigation, and timing (PNT) profile for the Energy Sector at the request of the U.S. Department of Energy. The Department of Energy is the sector-specific agency for the Energy Sector and is responsible for providing guidance in the form of this PNT Profile, per Executive Order 13905, Strengthening National Resilience Through Responsible Use of Positioning, Navigation, and Timing Services (Executive Office of the President 2020) issued February 18, 2020. Executive Order 13905 directed the National Institute of Standards & Technology to develop a PNT Profile that is broadly applicable to all sectors and to serve as a foundation for sector-neutral guidance, NISTIR 8323 Foundational PNT Profile: Applying the Cybersecurity Framework for the Responsible Use of Positioning, Navigation, and Timing (PNT) Services. This document builds on NISTIR 8323 to identify and serve as the required Energy Sector specific guidance. For purposes of this PNT Profile, Energy Sector precise time is 0.5 µs (microseconds) to 1 µs accuracy. Currently, the electricity subsector has systems that use this level of precision time, but the oil and natural gas subsector currently does not. While the electricity subsector uses precision timing, it does not use positioning and/or navigation at this level of accuracy. For this reason, this PNT Profile will focus on only precise time for the electricity subsector.

24 POWER TRANSMISSION AND DISTRIBUTION↗