Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Topographic slope from the SAR interferometric phase gradient

A new algorithm for the direct calculation of topographic slope maps from synthetic aperture radar (SAR) interferograms is presented. The algorithm derives slope maps without first requiring the creation of a digital elevational model (DEM) from the interferogram, thus obviating the need for high SNR in the interferogram and altitude calibration points for the scene. SAR data useful for interferometry has been collected by the Active Microwave Imager on board the ERS-1 satellite, when it was in a short period repeat orbit. Two passes of the radar sensor form a cross-track interferometric baseline. For a point target at some position (x,y,h), the interferometric phase difference phi is proportional to the difference in path lengths for the two sensor positions to the scatterer. Given the phase difference as measured in the complex interferogram and an accurate baseline geometry, the position of the scatterer, most significantly the height h, can be determined through triangulation. The interferometric phase measurement however is known only modulo 2-pi, and hence it is necessary to determine the correct multiple of 2-pi to add to the phase at each point to obtain an estimate of the actual phase with respect to an absolute datum. This phase unwrapping process is required for creating DEM's, and is difficult or impossible for regions of low SNR or SAR image layover. The new algorithm described here derives slope maps without requiring phase unwrapping.

Werner, Charles L.↗

Gas-liquid Phase Distribution and Void Fraction Measurements Using the MRI

We used a permanent-magnet MRI system to estimate the integral and spatially- and/or temporally-resolved void-fraction distributions and flow patterns in gas-liquid two-phase flows. Air was introduced at the bottom of the stagnant liquid column using an accurate and programmable syringe pump. Air flow rates were varied between 1 and 200 ml/min. The cylindrical non-conducting test tube in which two-phase flow was measured was placed in a 2.67 kGauss MRI with MRT spectrometer/imager. Roughly linear relationship has been obtained for the integral void-fraction, obtained by volume-averaging of the spatially-resolved signals, and the air flow rate in upward direction. The time-averaged spatially-resolved void fraction has also been obtained for the quasi-steady flow of air in a stagnant liquid column. No great accuracy is claimed as this was an exploratory proof-of-concept type of experiment. Preliminary results show that MRI a non-invasive and non-intrusive experimental technique can indeed provide a wealth of different qualitative and quantitative data and is especially well suited for averaged transport processes in adiabatic and diabatic multi-phase and/or multi-component flows.

Daidzic, N. E.↗

Radio wave propagation experiments to probe the ionosphere

Ionospheric bias corrections associated with radio tracking of spacecraft depend on the following measuring techniques for integrated electron content: (1) Faraday rotation measurements from an earth synchronous satellite; (2) ranging measurements at two frequencies; and (3) group and phase velocity measurements obtained from tracking data. The extraction of the integrated electron content directly from tracking data is achieved by comparison of range-rate measurements based on Doppler shift with differentiated range measurements based on tone delay. This method is most desirable because the measured corrections pertain directly to the spacecraft whose orbit is being determined and can be used in near earth as well as deep space tracking data.

Schmid, P. E.↗

Adjustment of sleep and the circadian temperature rhythm after flights across nine time zones

The adjustment of sleep-wake patterns and the circadian temperature rhythm was monitored in nine Royal Norwegian Airforce volunteers operating P-3 aircraft during a westward training deployment across nine time zones. Subjects recorded all sleep and nap times, rated nightly sleep quality, and completed personality inventories. Rectal temperature, heart rate, and wrist activity were continuously monitored. Adjustment was slower after the return eastward flight than after the outbound westward flight. The eastward flight produced slower readjustment of sleep timing to local time and greater interindividual variability in the patterns of adjustment of sleep and temperature. One subject apparently exhibited resynchronization by partition, with the temperature rhythm undergoing the reciprocal 15-h delay. In contrast, average heart rates during sleep were significantly elevated only after westward flight. Interindividual differences in adjustment of the temperature rhythm were correlated with some of the personality measures. Larger phase delays in the overall temperature waveform (as measured on the 5th day after westward flight) were exhibited by extraverts, and less consistently by evening types.

Gander, Philippa H.↗

NASA's Atmospheric Effects of Aviation Project: Results of the August 1999 Aerosol Measurement Intercomparison Workshop, Laboratory Phase

During August 1-14, 1999, NASA's Atmospheric Effects of Aviation Project (AEAP) convened a workshop at the NASA Langley Research Center to try to determine why such a wide variation in aerosol emissions indices and chemical and physical properties have been reported by various independent AEAP-supported research teams trying to characterize the exhaust emissions of subsonic commercial aircraft. This workshop was divided into two phases, a laboratory phase and a field phase. The laboratory phase consisted of supplying known particle number densities (concentrations) and particle size distributions to a common manifold for the participating research teams to sample and analyze. The field phase was conducted on an aircraft run-up pad. Participating teams actually sampled aircraft exhaust generated by a Langley T-38 Talon aircraft at 1 and 9 m behind the engine at engine powers ranging from 48 to 100 percent. Results from the laboratory phase of this intercomparison workshop are reported in this paper.

Cofer, W. Randy, III↗

MSFC/UAH Full Aperture Cryo-Figure AMSD Modal Characterization

A full-aperture, interferometric method for measuring the modal characteristics of the Advanced Mirror System Demonstrators (AMSDs) will be presented. The method involves stroboscopic surface figure measurement using an interferometer capable of simultaneous phase-shift measurements. Results of bread-board experiments will be presented as well as the plan for cryo measurements of the AMSDs.

Rogers, Ted↗

Phased Array Noise Source Localization Measurements Made on a Williams International FJ44 Engine

A 48-microphone planar phased array system was used to acquire noise source localization data on a full-scale Williams International FJ44 turbofan engine. Data were acquired with the array at three different locations relative to the engine, two on the side and one in front of the engine. At the two side locations the planar microphone array was parallel to the engine centerline; at the front location the array was perpendicular to the engine centerline. At each of the three locations, data were acquired at eleven different engine operating conditions ranging from engine idle to maximum (take off) speed. Data obtained with the array off to the side of the engine were spatially filtered to separate the inlet and nozzle noise. Tones occurring in the inlet and nozzle spectra were traced to the low and high speed spools within the engine. The phased array data indicate that the Inflow Control Device (ICD) used during this test was not acoustically transparent; instead, some of the noise emanating from the inlet reflected off of the inlet lip of the ICD. This reflection is a source of error for far field noise measurements made during the test. The data also indicate that a total temperature rake in the inlet of the engine is a source of fan noise.

Podboy, Gary G.↗

Fundamental aspects of pulse phase-locked loop technology-based methods for measurement of ultrasonic velocity

A new instrument based on a constant frequency pulse phase-locked loop concept has been developed to accurately measure the ultrasonic phase velocity in condensed matter. Measurements of the sound velocity in ultrapure water are reported in which both damped and undamped transducers are used with the instrument together with reflectors of various thicknesses placed in the sound propagation path. An analysis of measurements made with the new instrument and similar measurements, taken under identical experimental conditions, using a popular variable frequency pulsed-phase-locked loop instrument is reported. Uncertainties in both measurement systems are analyzed and discussed. A method for measuring inherent phase shifts, not addressed by previous investigations, within the variable frequency pulsed phase-locked loop system and a derivation of the equations that govern the overall use of variable frequency systems using phase-sensitive comparisons are presented. The effects of a finite pulse length on the measurements of phase velocity in dispersive media are addressed in detail.

Yost, William T.↗

Planetary astronomy and supporting laboratory research

The aim was to obtain form laboratory measurements the molecular parameters needed to interpret observations of planetary and cometary spectra, and to develop the analytical and computational techniques to interpret the observed spectra in terms of planetary atmospheres including solids and cometary ices. The gas phase molecular parameters measured include the intensities and half-widths of vib-rotational lines, total intensities of absorption bands, temperature dependencies, and absorption and pressure parameters in random-band models of absorption bands. Computation of line shapes of H2 quadrupole lines from quantum mechanical first principles for comparison with laboratory data and use in modeling of planetary atmospheres was accomplished. The solid phase measurements include band profile and quantitative intensity measurements and dependence on composition as well as thermal and photolytic processing which mimics the particular astrophysical environments. Work on GeH4, PH3, has made significant progress.

Valero, F. P. J.↗

Single particle aerodynamic relaxation time analyzer

An instrument employing a laser Doppler velocimeter and a microphone to measure the phase lag of the motion of aerosol particulates relative to the motion of the fluid medium within an acoustic field is described. The relaxation times and aerodynamic diameters of the particles or droplets are determined in real time from the measured values of phase lag; thus, the size analysis is independent of the electrostatic charges and refractive indices of the particulates. The instrument is suitable for analyzing the aerodynamic size spectrum of atmospheric particulate pollutants with aerodynamic diameters ranging from 0.1 to 10.0 microns.

Mazumder, M. K.↗