The effects of tracking station location uncertainty and measurement bias errors during phases of the Apollo mission
Effects of measurement noise, measurement bias, and station location uncertainties on Apollo mission phases
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Effects of measurement noise, measurement bias, and station location uncertainties on Apollo mission phases
The performance of a Phase Doppler Particle Analyzer (PDPA) based icing probe suitable for use in icing tunnels and airborne applications is assessed. The instrument is shown to accurately and repeatably measure liquid water content (LWC) to within better than 20 percent of the nominal expected value in the NASA Lewis IRT. This was seen to be true over a wide range of tunnel operating conditions. The principles used by the PDPA for MVD and LWC determination are discussed. Calibration curves for the IRT median volume diameter are also determined and compared to the existing calibration determined via the PMS instruments. As has been shown in previous work, the PDPA is quite repeatable. The results are typically 3 to 5 microns smaller than the existing calibrations for a given run condition. Reasons for these differences are also discussed.
Measurement of phase volume fractions in water-containing multiphase flows is necessary for the optimization of a host of industrial flow processes. Many water-containing multiphase flows can be classified as either water-dispersed or water-continuous mixtures. A recently developed approach based on Hanai’s mixture formula and utilizing electrical capacitance tomography (ECT) sensors have shown good potential for obtaining water volume fraction estimates in two-phase water-containing flows with different water salinity levels. However, the proposed approach was investigated via controlled experiments restricted to static configurations while, in practice, multiphase flows can be dynamic and unpredictable. In this work, we perform a flow loop study of the proposed ECT-based method for volume fraction estimation in oil–water two-phase flows. Here, we evaluate the performance of the proposed method in both water-dispersed and water-continuous flow regimes by employing different types of capacitive sensors in cylindrical arrangements and parallel-plate rectangular arrangements.
The theory of a phase insensitive receiver based on acousto-electric effect is presented along with experimental characteristics of a CdS acousto-electric converter (AEC). Since the AEC is nearly phase insensitive, it is ideal for measurements in inhomogeneous materials and/or materials with irregular flatness and parallelism. Through transmission ultrasonic C-scan data of phantom flaws demonstrates a significant improvement in flaw characterization with an AEC over that of a conventional transducer. In addition, measurements with conventional transducers in anisotropically stressed metal samples are shown to lead to grossly inaccurate results due to phase sensitivity. Various other measurements are presented with data contrasting conventional transducers with an AEC in specific NDE applications.
The theory of a phase insensitive receiver based on acousto-electric effect is presented along with experimental characteristics of a CdS acousto-electric converter (AEC). Since the AEC is nearly phase insensitive, it is ideal for measurements in inhomogeneous materials and/or materials with irregular flatness and parallelism. Through transmission ultrasonic C-scan data of phantom flaws demonstrates a significant improvement in flaw characterization with an AEC over that of a conventional transducer. In addition, measurements with conventional transducers in anisotropically stressed metal samples are shown to lead to grossly inaccurate results due to phase sensitivity. Various other measurements are presented with data contrasting conventional transducers with an AEC in specific NDE applications.
A self phased array was developed for propagation measurements on an earth-space path. The 11.7 GHz CTS beacon was used as the signal source. The self phased array was used to measure angle of arrival as well as attenuation and scintillation statistics. The performance of the array is described, and sample data are presented. The tracking capability of the self phased array was also studied. This technique permits fully electronic, nonmechanical satellite tracking, thus simplifying unmanned operation and eliminating severe weather tracking constraints.
An electronic optical laser interferometer capable of resolving depth differences of as low as 30 A and planar displacements of 6000 A was constructed to examine surface profiles of bearing surfaces without physical contact. Topological chemical reactivity was determined by applying a drop of dilute alcoholic hydrochloric acid and measuring the profile of the solid surface before and after application of this probe. Scuffed bearing surfaces reacted much faster than virgin ones but that bearing surfaces exposed to lubricants containing an organic chloride reacted much more slowly. The reactivity of stainless steel plates, heated in a nitrogen atmosphere to different temperatures, were examined later at ambient temperature. The change of surface contour as a result of the probe reaction followed Arrhenius-type relation with respect to heat treatment temperature. The contact area of the plate of a ball/plate sliding elastohydrodynamic contact run on trimethylopropane triheptanoate with or without additives was optically profiled periodically. As scuffing was approached, the change of profile within the contact region changed much more rapidly by the acid probe and assumed a constant high value after scuffing. A nonetching metallurgical phase was found in the scuff mark, which was apparently responsible for the high reactivity.
A method is provided for controlling two objects relatively moveable with respect to each other. A plurality of receivers are provided for detecting a distinctive microwave signal from each of the objects and measuring the phase thereof with respect to a reference signal. The measured phase signal is used to determine a distance between each of the objects and each of the plurality of receivers. Control signals produced in response to the relative distances are used to control the position of the two objects.
An algorithm has been demonstrated for simultaneously measuring the phase and arrival time of optical pulses relative to pulses in a reference channel using one detector array. Based on this algorithm, a simple optoelectronic pulse phase and arrival time stabilisation scheme has been designed for operation in a coherent beam combining fibre system for ultrashort pulses (including chirped ones). We have studied the performance of the stabilisation scheme. In particular, we have reached a phase measurement rate of 25 000 cps, demonstrated an ∼ 2 kHz limiting phase stabilisation frequency in a feedback loop, and obtained an arrival time measurement accuracy of ∼ 5 % of the transform-limited pulse duration at a measurement rate of 5 cps. In experiments concerned with coherent beam combining for two channels of a pulsed fibre system at a wavelength of 1030 nm, we have demonstrated phase stabilisation with an accuracy better than λ/100 and delay setting accuracy of 10 fs at a transform-limited pulse duration of ∼ 200 fs and obtained 94 % beam combining efficiency. (paper)
Variational quantum algorithms (VQAs), which classically optimize a parametrized quantum circuit to solve a computational task, promise to advance our understanding of quantum many-body systems and improve machine learning algorithms using near-term quantum computers. Prominent challenges associated with this family of quantum-classical hybrid algorithms are the control of quantum entanglement and quantum gradients linked to their classical optimization. Known as the barren plateau phenomenon, these quantum gradients may rapidly vanish in the presence of volume-law entanglement growth, which poses a serious obstacle to the practical utility of VQAs. Inspired by recent studies of measurement-induced entanglement transition in random circuits, we investigate the entanglement transition in variational quantum circuits endowed with intermediate projective measurements. Considering the Hamiltonian Variational Ansatz (HVA) for the XXZ model and the Hardware Efficient Ansatz (HEA), we observe a measurement-induced entanglement transition from volume-law to area-law with increasing measurement rate. Moreover, we provide evidence that the transition belongs to the same universality class of random unitary circuits. Importantly, the transition coincides with a “landscape transition” from severe to mild/no barren plateaus in the classical optimization. Our work may provide an avenue for improving the trainability of quantum circuits by incorporating intermediate measurement protocols in currently available quantum hardware.
Measurements are examined of snow coverage during the snow-melt season in 1973 and 1974 from LANDSAT imagery for the three Columbia River Subbasins. Satellite derived snow cover inventories for the three test basins were obtained as an alternative to inventories performed with the current operational practice of using small aircraft flights over selected snow fields. The accuracy and precision versus cost for several different interactive image analysis procedures was investigated using a display device, the Electronic Satellite Image Analysis Console. Single-band radiance thresholding was the principal technique employed in the snow detection, although this technique was supplemented by an editing procedure involving reference to hand-generated elevation contours. For each data and view measured, a binary thematic map or "mask" depicting the snow cover was generated by a combination of objective and subjective procedures. Photographs of data analysis equipment (displays) are shown.
System allows precise measurement of phase shift between two toneburst signals initially derived from same periodic source but delayed by different amounts through either path-length differences, propagation velocity differences, or both. Used to measure accurately phase shift encountered by acoustic wave striking front and back surfaces of sample. Velocity known, resulting measurement is of sample thickness. Thickness known, measurement is of sound velocity. Technique applies to many sources of radiation and not limited to acoustics.
Although phase diagrams can be leveraged to investigate high transition temperature (high-T c ) superconductivity, the issue has not been discussed thoroughly. In this study, we elucidate the phase diagram of the overdoped side of high-T c cuprates via systematic anisotropic transport measurements for Pb-doped Bi-2212 single crystals. We demonstrate that the characteristic temperatures of the “weak” pseudogap opening and electronic coherence cross each other at a critical doping level, while those of the “strong” pseudogap merges into that of superconducting fluctuations above the critical doping level. Her the results indicate the importance of Mottness in high-T c superconductivity.
This oral presentation explains that measurements of the opposition surge (the nonlinear increase in reflectance seen in particulate materials when observed at small phase angles) are the first ever made using the JPL long-arm goniometer, which permits very small phase angle measuremnets to be made.
Neutron interferometry has played a distinctive role in fundamental science and characterization of materials. Moiré neutron interferometers are candidate next-generation instruments: they offer microscopy-like magnification of the signal, enabling direct camera recording of interference patterns across the full neutron wavelength spectrum. Here we demonstrate the extension of phase-grating moiré interferometry to two-dimensional geometries. Our fork-dislocation phase gratings reveal phase singularities in the moiré pattern, and we explore orthogonal moiré patterns with two-dimensional phase gratings. Our measurements of phase topologies and gravitationally induced phase shifts are in good agreement with theory. These techniques can be implemented in existing neutron instruments to advance interferometric analyses of emerging materials and precision measurements of fundamental constants. Published by the American Physical Society 2024
Detection and measurement of cycle skipping and phase offsets in frequency multiplying phase-lock filters
A comparative study of the gaps measured in two techniques, angle-resolved photoelectron spectroscopy and spectroscopic imaging scanning tunneling microscopy, is presented herein. In particular the study focuses on the more overdoped region of the cuprate phase diagram in the superconducting state. While the total densities of states measured in the two techniques agree very well, it is shown that the peak in the density of states, Δ DOS , is consistently displaced to higher energies relative to the maximal superconducting gap, Δ 0 , determined in photoemission. The difference between the two gaps is more evident for the less doped samples reflecting increased normalization of bands. This observation will clearly influence the boundaries in the phase diagrams of the cuprates defined by these two techniques.