Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Performance and Techno-Economic Evaluation of a Three-Phase, 50-kW SiC-Based PV Inverter

The technical capabilities and benefits of silicon carbide (SiC) compared to silicon (Si) based power electronics converters as well as the premium associated with using SiC instead of Si are well understood. This work proves that the benefits provided by SiC, such as increased efficiency, would result in a lower levelized cost of energy (LCOE) compared to both commercially available, state-of-the-art inverters and the benchmark commercial system cost calculated for the U.S. Department of Energy Solar Energy Technologies Office's SunShot program. The LCOE is calculated to be same as the commercial benchmark despite the installed system cost being 8% more than the benchmark. The LCOE calculation is based on both experiential values obtained from testing the SiC photovoltaic (PV) inverter and on the bottoms-up modeled volume cost for the same 50-kW SiC-based inverter. The PV system used for the LCOE model is also explained, and the system cost breakout is presented in this paper. Furthermore, multiple scenarios with variations in the PV system are presented to show their effect on the system LCOE.

14 SOLAR ENERGY↗

Automated Shift Detection in Sensor-Based PV Power and Irradiance Time Series: Preprint

PV power and irradiance sensor-based measurements are prone to error, resulting in issues such as abrupt time series data shifts. These shifts, which are usually unintentional, may be caused by software or hardware configuration changes on a PV system, and do not reflect an actual change in overall system performance. Locating these shifts and segmenting the associated time series aids in more accurate future PV analysis. In this research, an offline changepoint detection (CPD) algorithm that automatically detects these abrupt data shifts in sensor-based time series is introduced. Data shift periods in 101 daily PV power and irradiance time series were labeled manually by two solar experts. These data streams represent sensor-based measurements, and display a variety of data shift behaviors. A changepoint detection algorithm was tuned using the 101 labeled data streams, with each model configuration's ability to detect labeled changepoints benchmarked using metrics such as F1-score, recall, and Rand Index. Best performing models on seasonality-corrected data streams include the Pruned Exact Linear (PELT) method, the Binary Segmentation method, and the Bottom-Up method, all scoring an average F1-score of 0.76 or greater at detecting labeled changepoints within a 30-day window for the labeled data sets. To promote further research in this space, we are releasing the labeled data shift sets on U.S. Department of Energy's (DOE) DuraMAT Data Hub, and the associated algorithm in the Python PVAnalytics package.

changepoint detection↗

Automated Shift Detection in Sensor-Based PV Power and Irradiance Time Series

PV power and irradiance sensor-based measurements are prone to error, resulting in issues such as abrupt time series data shifts. These shifts, which are usually unintentional, may be caused by software or hardware configuration changes on a PV system, and do not reflect an actual change in overall system performance. Locating these shifts and segmenting the associated time series aids in more accurate future PV analysis. In this research, an offline changepoint detection (CPD) algorithm that automatically detects these abrupt data shifts in sensor-based time series is introduced. Data shift periods in 101 daily PV power and irradiance time series were labeled manually by two solar experts. These data streams represent sensor-based measurements, and display a variety of data shift behaviors. A changepoint detection algorithm was tuned using the 101 labeled data streams, with each model configuration's ability to detect labeled changepoints benchmarked using metrics such as F1-score, recall, and Rand Index. Best performing models on seasonality-corrected data streams include the Pruned Exact Linear (PELT) method, the Binary Segmentation method, and the Bottom-Up method, all scoring an average F1-score of 0.76 or greater at detecting labeled changepoints within a 30-day window for the labeled data sets. To promote further research in this space, we are releasing the labeled data shift sets on U.S. Department of Energy's (DOE) DuraMAT Data Hub, and the associated algorithm in the Python PVAnalytics package.

changepoint detection↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Storage Futures Study: Economic Potential of Diurnal Storage in the U.S. Power Sector

We model the evolution of the U.S. electricity sector from 2020 through 2050 and find significant market potential (>125 GW) for diurnal energy storage across all 19 scenarios considered. Most of this storage has 4-6 hours of duration. We find that storage deployment is driven primarily by the combination of capacity value and energy time-shifting value, and that the combination of these value streams is needed for optimal storage deployment to be realized. We also find a strong correlation of PV penetration and storage market potential. Cost and performance metrics in this study focus on Li-ion batteries because the technology has more market maturity than other emerging technologies but results from this study can be generalized to any technologies that meet the cost and performance projections assumed.

25 ENERGY STORAGE↗

Integrating Concentrating Solar Power Technologies into the Hybrid Optimization and Performance Platform (HOPP)

As the world increases renewable energy deployment, there is an increasing interest in hybridizing various generation and storage technologies to maximize net benefit to the developer and/or off-taker. A particularly interesting combination of renewable technologies is concentrating solar power (CSP) with thermal energy storage (TES), photovoltaics (PV), and electrochemical battery energy storage (BESS). Due to the system complexity of CSP technology, it is difficult to evaluate the technological and financial performance of a CSP-PV hybrid system without detailed modeling of annual operations. To address this challenge, we have developed a modeling framework for evaluating the performance and financial viability of CSP systems hybridized with PV and battery technologies. This modeling effort incorporates CSP tower and trough systems into an existing modeling tool recently developed by NREL referred to as the Hybrid Optimization and Performance Platform (HOPP). This report outlines the modeling methodology as well as preliminary results from example case studies conducted using the model. The methodology describes: (i) the integration of CSP tower and troughs into HOPP using python interfaces to access System Advisor Model (SAM) underlining technology models, (ii) the mathematical formulation of the mixed integer linear program dispatch optimization model which optimizes operations of storage asset to either maximize system revenue or minimize operating cost while load following, (iii) the design analysis methods implemented within HOPP, and (iv) simulation clustering for the purposes of reducing computational expense. We exercise the model using a case study of a future scenario where we assume (i) CSP and PV technologies achieve the 2030 cost targets provided by the Solar Energy Technologies Office (SETO), (ii) battery costs reduce to the 2030 mid cost projection presented by NREL. Lastly, (iii) electricity prices for southern California in 2030 are provided by NREL's Cambium database, and (iv) a capacity payment of $150/kW-yr based on the system capacity factor during the to 100 net-load hours.

14 SOLAR ENERGY↗

Dynamic Wind Loading on Compliant, Floating PV Arrays: Cooperative Research and Development (Final Report)

PV panels are subjected to wind loads during normal outdoor operation, where th wind speed, wind direction, panel angle, and array layout play a large role in the overall loading magnitude. For floating PV systems, where panels are installed on floating rafts, these forces can lead to a dynamic displacement of the raft and mounted PV hardware. The Contractor and Participant will perform fluid-structure interaction simulations of this phenomenon for a variety of wind speeds, directions, and panel angles to characterize these forces and help design mooring/tethering lines to resist and anchor raft movement.

14 SOLAR ENERGY↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Design, optimization, and analysis of a self-deploying PV tent array

A tent shaped PV array was designed and the design was optimized for maximum specific power. In order to minimize output power variation a tent angle of 60 deg was chosen. Based on the chosen tent angle an array structure was designed. The design considerations were minimal deployment time, high reliability, and small stowage volume. To meet these considerations the array was chosen to be self-deployable, form a compact storage configuration, using a passive pressurized gas deployment mechanism. Each structural component of the design was analyzed to determine the size necessary to withstand the various forces to which it would be subjected. Through this analysis the component weights were determined. An optimization was performed to determine the array dimensions and blanket geometry which produce the maximum specific power for a given PV blanket. This optimization was performed for both lunar and Martian environmental conditions. Other factors such as PV blanket types, structural material, and wind velocity (for Mars array), were varied to determine what influence they had on the design point. The performance specifications for the array at both locations and with each type of PV blanket were determined. These specifications were calculated using the Arimid fiber composite as the structural material. The four PV blanket types considered were silicon, GaAs/Ge, GaAsCLEFT, and amorphous silicon. The specifications used for each blanket represented either present day or near term technology. For both the Moon and Mars the amorphous silicon arrays produced the highest specific power.

Collozza, Anthony J.↗

Evaluating the Capabilities of Behind-the-Meter Solar-plus-Storage for Providing Backup Power during Long-Duration Power Interruptions [Slides]

The study estimates the performance of behind-the-meter solar PV-plus-energy-storage-systems (PVESS) in providing critical-load or whole-building backup across a wide range of geographies, building types, and power interruption conditions. The study also considers a set of 10 historical long-duration power outage events and evaluates how PVESS could have performed in providing backup power during those specific events. The analysis is the first in what will be a series of studies by Berkeley Lab, in collaboration with the National Renewable Energy Laboratory, on the use of PVESS for backup power. This initial study, which relies on simulated end-use level building loads, solar generation, and storage dispatch, is intended to provide a baseline set of performance estimates and to illustrate key performance drivers.

14 SOLAR ENERGY↗

The Roles and Impacts of PV-Battery Hybrids in a Decarbonized U.S. Electricity Supply

In this paper, we explore the potential impacts of growing industry interest in hybrid systems comprising PV and battery technologies on the results and findings of the Solar Futures Study (DOE 2021). We employ similar scenario definitions in the same ReEDS capacity expansion model, but we perform two versions of each scenario: one in which PV and battery technologies must be deployed separately (No Hybrids), and one in which the model has the option of deploying them together as PVB hybrids (With Hybrids). By comparing the No Hybrids and With Hybrids versions of each scenario, we isolate the impacts of hybridization on the outcomes and findings of the Solar Futures Study. We find that PVB hybrid configurations capture a sizable share of PV deployment, and the highest-net-value PVB hybrid configuration depends strongly on policy conditions. A power sector decarbonization policy generally increases the value proposition of a more forward-looking PVB hybrid configuration that involves significant oversizing of the PV arrays, a larger battery (which facilitates greater recovery and utilization of otherwise clipped energy), and a higher capacity factor. The growing deployment of PVB hybrid configurations primarily displaces standalone PV capacity, such that total installed PV capacity is largely unaffected by the availability of PVB hybrid configurations. However, the higher capacity factors associated with PVB hybrid configurations drive a modest (1-2 percentage point) increase in PV's share of U.S. electricity supply in 2050. Finally, introducing the PVB hybrid configurations influences the future role and makeup of battery storage technologies, and it reduces the required transmission expansion, particularly under scenarios that involve a power sector decarbonization policy.

14 SOLAR ENERGY↗

Test and Evaluation of Solar Foil Directly Mounted on the Ground (Final Report)

HyET Solar (HyET), established in 2012, is a small business developing a thin-film silicon solar photovoltaic (PV) product called "Power Foil" that can be mounted directly on the constructed earthen dykes. HyET's goals are for low-cost, efficient, generation of PV electricity at utility scale. HyET has requested assistance from the National Renewable Energy Laboratory (NREL) to evaluate the performance of the Power Foil product in several outdoor environments, with a particular focus on 1) heat effects on efficiency and 2) heat and UV effects on reliability and durability. NREL has been working on PV module testing at laboratory scale for more than 40 years, and has the equipment and facilities required to provide the PV material testing required.

14 SOLAR ENERGY↗

Optimal hybrid power plants for electric vehicle charging demand

Transmission constraints, increasing motivations to decarbonize, and concerns over peak electric vehicle (EV) load impacts on local grids have driven electric customers to consider behind-the-meter, hybrid power plant generation and storage at the distributed-grid level for EV charging. In this study, we develop capabilities to optimize hybrid power plant component capacities for EV charging. We then demonstrate these capabilities in a case study for Boulder, Colorado, using public EV charging data as well as wind and solar resource data. Our results show system designs that balance the cost of energy with load-meeting and peak shaving performance. Within the case study, systems designed for wind, solar photovoltaic (PV), and storage resulted in lower cost of energy than those optimized for PV and storage only. This indicates that in areas where wind resource exists, hybrid power plants that include wind, PV, and battery assets can better meet EV charging loads (including peak loads that are prone to overloading local grids) than PV and battery assets alone. Future work to address limitations in this paper include extending cost modeling to include performance losses (e.g., based on operations or weather) and charging station costs to estimate levelized cost of charging, and quantifying uncertainty and error in our aggregation methods for estimating EV charging loads at the hourly timescale.

14 SOLAR ENERGY↗

Field‐Relevant Degradation Mechanisms in Metal Halide Perovskite Modules

Field testing, failure analysis, and understanding of degradation mechanisms are essential to advancing metal halide perovskite (MHP) photovoltaic (PV) technology toward commercialization. Here, we present performance data from up to 1 year of outdoor testing of MHP modules in Golden, Colorado. The module encapsulation architecture and encapsulant materials have a significant impact on module reliability, with modules containing a polyolefin elastomer (POE) in addition to a desiccated polyisobutylene (PIB) edge seal outlasting modules with only a PIB edge seal or PIB blanket. Nondestructive and destructive characterization of the field-tested modules points to module scribes and interfaces as areas of potential mechanical weakness and chemical migration, resulting in shunt pathways and increased series resistance. Finally, indoor accelerated stress testing with light and elevated temperatures is performed, demonstrating failure with similar scribe degradation signatures as compared to the field-tested modules. In conclusion, under both outdoor testing and light and elevated temperature conditions, electrochemical corrosion between the copper electrode and the mobile iodine ions appeared dominant, with a significant progression at the scribes that is speculated to result from an interplay between the initial laser damage and joule heating from enhanced ion diffusion under bias.

14 SOLAR ENERGY↗

FAIRification, Quality Assessment, and Missingness Pattern Discovery for Spatiotemporal Photovoltaic Data

The growth of the photovoltaic market has pushed the demand for power forecasting and performance evaluation for a huge population of PV power plants. Many of these power plants have spatiotemporal coherence that can be utilized for improving model accuracy. We have demonstrated in this paper the FAIRification of spatiotemporal PV time series data. Through the creation of a solar power plant ontology, we propose standards for the naming and structure of metadata used to describe the data from these power plants. Using the structure from this ontology, we have developed both R and Python packages for the automation of the FAIRification process. Going further, we have also developed an R package that automates the analysis of the quality of a data set through the designation of letter grades. To solve the issue of data missingness, we propose the use of St-GNN autoencoders to detect and impute missing values from a data set by utilizing data from power plants nearby.

14 SOLAR ENERGY↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗

Validation of Silevo Modules at the Regional Test Centers (Cooperative Research and Development Final Report, CRADA Number CRD-15-589)

Silevo and the National Renewable Energy Laboratory (NREL) are entering into a cooperative research and development agreement (CRADA) in order to perform validation testing of Silevo's Photovoltaic (PV) modules through the Department of Energy (DOE) Regional Test Center (RTC) program. This CRADA describes testing activities conducted specifically at the NREL-managed Colorado RTC site.

14 SOLAR ENERGY↗