Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PUMPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Performance Evaluation of the ThermoLift Natural Gas Fired Air Conditioner and Cold-Climate Heat Pump

ThermoLift is currently developing its Thermal Compression Heat Pump (TCHP™), a natural-gas driven air conditioner and cold-climate heat pump, which can provide space heating, water heating, and air conditioning simultaneously in a single device. The system has broad application as a combined heating, ventilation, and air-conditioning (HVAC) solution with the benefit of substantial energy, cost, and greenhouse gas (GHG) reductions. Unlike traditional vapor compression heat-pumps, the TCHP™ uses helium as a working fluid in place of high global warming potential (GWP) refrigerants. The development effort has produced three iterations or generations of prototypes with advancement of the technology readiness level (TRL) from TRL-1 (TCHP™ Gen 1.0) to TRL-5 (TCHP™ Gen 3.0). In August of 2013, the US DOE solicited the submission of proposals through funding opportunity announcement DE-FOA-0000823, Building Technologies Innovations Program. The Office of Energy Efficiency and Renewable Energy (EERE) subsequently accepted ThermoLift’s proposal to develop a heat pump system based on the Hofbauer cycle, a new cycle that supplants the Vuilleumier cycle and provided funding for prototype evaluation at Oak Ridge National Laboratory (ORNL). ORNL is a widely known research center for developing and evaluating building technologies. Through its Building Technologies Research and Integration Center, ORNL has unique capabilities which allows them to collaborate with industry and academia to advance building component technologies. The TCHP™ Gen 3.0 prototype was shipped to ORNL on July 23, 2018. After installation and integration of the heat pump into ORNL’s test facility and performing instrumentation validation and calibration, extended operation of the heat pump was achieved during continuous operation on August 6, 2018, and includes various heating and cooling temperature ranges and performance analysis. The Gen 3.0 prototype was evaluated at four “ambient” temperatures: −25°C, −8.33°C, 8.33°C, and 20°C, (−13°F, 17°F, 47°F, and 68°F) denoted as test points 1-4, respectively. For heating, cycle coefficients of performance (COP) at the four “ambient” temperatures were found to be 1.30, 1.46, 1.52, and 1.61, respectively. Furthermore, there is no capacity reduction as the inlet temperature to the cold heat exchanger (HX) decreases. The heating capacity delivered by the TCHP was found to be 12 kW at -25°C. Finally, this final report identifies measures for obtaining further efficiency improvements.

42 ENGINEERING↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing the Subsurface Using Deformation from Pumping and Surface Loading Tests

Changes in pore pressure or applied load cause deformation that can be used to characterize the subsurface. A series of field tests were conducted by measuring the deformation and pressure response from a variety of stresses at our test site in South Carolina. The site is underlain by saprolite to a depth of 30 m, and the water table in the unconfined aquifer occurs at a depth of 9 m. The types of tests performed included constant-rate pumping tests and surface point loading tests using the weight of a person or vehicle. Vertical displacement of the saprolite in response to these stresses was measured at depths of 3, 6, 9 and 11 meters in both saturated and unsaturated conditions using an extensometer with a resolution of +/- 10 nm. Results from 2.5-hr-long constant-rate pumping tests indicate a repeatable, compressive vertical strain of roughly 0.1 microstrain in the vadose zone and 1-10 microstrain in the saturated zone. Drawdown was 5 m in the pumping well and 0.1 m in a nearby (r = 9m) observation well. Under saturated conditions, the strain rate gradually decreased throughout the test in a pattern that resembles the drawdown curve in the monitoring well. In contrast, the strain in the vadose zone increased quickly early in the test, but the strain rate diminished and was negligible after approximately 30 minutes of pumping. Interestingly, drawdown in the pumping well also increased quickly over 30 minutes and remained roughly constant after that. Additional tests were conducted by applying a load (weight of a person or vehicle) at the ground surface above the extensometer and allowing the signal to stabilize before removing the load. In the vadose zone, the soil compressed rapidly and then stabilized. In the saturated zone, sudden compression was followed by additional compression at a much slower rate. A similar response was observed upon removal of the load. This transient signal in the saturated zone is interpreted to be a poroelastic effect. When a load is applied, the solid skeleton compresses and pressurizes the pore fluid, causing flow. The strain rate is then a function of pressure diffusion. Simulation of the deformation from both pumping and loading tests using an unsaturated, poroelastic finite-element model indicates that strains are sensitive to the Young’s modulus and hydraulic conductivity as functions of saturation.

well tests, strain, surface loading, hydromechanic↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, Gianluigi [Thomas Jefferson National Acce↗

Heat Pumps in the United States: Market Potentials, Challenges and Opportunities

The US heat pump market has been affected by the socioeconomic impacts of the COVID-19 pandemic. However, the US administration’s electrification goal accelerates the deployment of heat pumps, and the US heat pump market has experienced steady growth since 2010. In 2020, heat pumps surpassed gas furnace shipments for the first time, and the trend maintained through 2022. The heat pump market share is expected to grow as policies, and financial incentives steer the building sector toward decarbonization. Here, this paper reviews the US heat pump market trends and discusses the challenges and opportunities in the current policy landscape.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Study of a heat rejection system using capillary pumping

Results of an analytical study investigating the application of capillary pumping to the heat rejection loop of an advanced Rankine cycle power conversion system are presented. The feasibility of the concept of capillary pumping as an alternate to electromagnetic pumping is analytically demonstrated. Capillary pumping is shown to provide a potential for weight and electrical power saving and reliability through the use of redundant systems. A screen wick pump design with arterial feed lines was analytically developed. Advantages of this design are high thermodynamic and hydrodynamic efficiency, which provide a lightweight easily packaged system. Operational problems were identified which must be solved for successful application of capillary pumping. The most important are the development of start up and shutdown procedures, and development of a means of keeping noncondensibles from the system and of earth-bound testing procedures.

Neal, L. G.↗

Stimulated emission in multiple-photon-pumped xenon and argon excimers.

A pumping process involving the multiphoton absorption of laser radiation at 3547 and 2660 A is employed in the investigation. Typically, about 25% of the incident pumping radiation is absorbed and effective in producing excimer fluorescence. The four cases studied include 2660-A-pumped argon, 2660-A-pumped xenon, 3547-A-pumped xenon, and 3547-A-pumped argon. Results concerning the on-axis and off-axis fluorescence obtained from the excimers are presented in a graph.

Harris, S. E.↗

Development of a mercury electromagnetic centrifugal pump for the SNAP-8 refractory boiler development program

An electromagnetic pump, in which pressure is developed in mercury because of the interaction of the magnetic field and current which flows as a result of the voltage induced in the mercury contained in the pump duct, was developed for the SNAP-8 refractory boiler test facility. Pump performance results are presented for ten duct configurations and two stator sizes. These test results were used to design and fabricate a pump which met the SNAP-8 criteria of 530 psi developed pressure at 12,500 lb/hr. The pump operated continuously for over 13,000 hours without failure or performance degradation. Included in this report are descriptions of the experimental equipment, measurement techniques, all experimental data, and an analysis of the electrical losses in the pump.

Fuller, R. A.↗

Investigation of the Centaur boost pump overspeed condition at main engine shutdown on the Titan Centaur TC-2 flight

An investigation was conducted to evaluate a potential boost pump overspeed condition which could exist on the Titan/Centaur launch vehicle after main engine shut-off. Preliminary analyses indicated that the acceleration imparted to the unloaded boost pump-turbine assembly, caused by purging residual hydrogen peroxide from the turbine supply lines, could result in a pump-turbine overspeed. Previous test experience indicated that turbine damage occurs at speeds in excess of 75,000 rpm. Detailed theoretical analyses, in conjunction with pump tests, were conducted to establish the maximum pump-turbine speed at main engine shut-off. The analyses predicted a maximum speed of 68,000 rpm. Testing showed the pump-turbine speed to be 66,700 rpm in the overspeed condition. Inasmuch as both the analysis and tests showed the overspeed to be sufficiently less than the speed at which damage could occur, it was concluded that no corrective action would be required for the launch vehicle.

Baud, K. W.↗

Diode pumped Nd:YAG laser development

A low power Nd:YAG laser was constructed which employs GaAs injection lasers as a pump source. Power outputs of 125 mW TEM CW with the rod at 250 K and the pump at 180 K were achieved for 45 W input power to the pump source. Operation of the laser, with array and laser at a common heat sink temperature of 250 K, was inhibited by difficulties in constructing long-life GaAs LOC laser arrays. Tests verified pumping with output power of 20 to 30 mW with rod and pump at 250 K. Although life tests with single LOC GaAs diodes were somewhat encouraging (with single diodes operating as long as 9000 hours without degradation), failures of single diodes in arrays continue to occur, and 50 percent power is lost in a few hundred hours at 1 percent duty factor. Because of the large recent advances in the state of the art of CW room temperature AlGaAs diodes, their demonstrated lifetimes of greater than 5,000 hours, and their inherent advantages for this task, it is recommended that these sources be used for further CW YAG injection laser pumping work.

Reno, C. W.↗

Low-thrust chemical propulsion system pump technology

Candidate pump and driver systems for low thrust cargo orbit transfer vehicle engines which deliver large space structures to geosynchronous equatorial orbit and beyond are evaluated. The pumps operate to 68 atmospheres (1000 psi) discharge pressure and flowrates suited to cryogenic engines using either LOX/methane or LOX/hydrogen propellants in thrust ranges from 445 to 8900 N (100 to 2000 lb F). Analysis of the various pumps and drivers indicate that the low specific speed requirement will make high fluid efficiencies difficult to achieve. As such, multiple stages are required. In addition, all pumps require inducer stages. The most attractive main pumps are the multistage centrifugal pumps.

Sabiers, R. L.↗

Highly efficient neodymium:yttrium aluminum garnet laser end pumped by a semiconductor laser array

In recent experiments, 80-mW CW power in a single mode has been achieved from a neodymium:yttrium aluminum garnet (Nd:YAG) laser with only 1 W of electrical power input to a single semiconductor laser array pump. This corresponds to an overall efficiency of 8 percent, the highest reported CW efficiency for a Nd:YAG laser. A tightly focused semiconductor laser end pump configuration is used to achieve high pumping intensities (on the order of 1 kW/sq cm), which in turn causes the photon to photon conversion efficiency to approach the quantum efficiency (76 percent for Nd:YAG at 1.06 microns pumped at 0.810 micron). This is achieved despite the dual-lobed nature of the pump. Through the use of simple beam-combining schemes (e.g., polarization coupling and multireflection point pumping), output powers over 1 W and overall electrical to optical efficiencies as high as 10 percent are expected.

Sipes, D. L.↗

Direct solar-pumped iodine laser amplifier

During this period the parametric studies of the iodine laser oscillator pumped by a Vortek simulator were carried out before amplifier studies. The amplifier studies are postponed to the extended period after completing the parametric studies. In addition, the kinetic modeling of a solar-pumped iodine laser amplifier, and the experimental work for a solar pumped dye laser amplifier are in progress. This report contains three parts: (1) a 10 W CW iodine laser pumped by a Vortek solar simulator; (2) kinetic modeling to predict the time to lasing threshold, lasing time, and energy output of solar-pumped iodine laser; and (3) the study of the dye laser amplifier pumped by a Tamarack solar simulator.

Han, K. S.↗

Direct solar-pumped iodine laser amplifier

In order to evaluate the feasibility of the solar pumped dye laser, the parametric study of a dye laser amplifier pumped by a solar simulator and flashlamp was carried out, and the amplifier gains were measured at various pump beam irradiances on the dye cell. Rhodamine 6G was considered as a candidate for the solar pumped laser because of its good utilization of the solar spectrum and high quantum efficiency. The measurement shows that a solar concentration of 20,000 is required to reach the threshold of the dye. The work to construct a kinetic model algorithm which predicts the output parameter of laser was progressed. The kinetic model was improved such that there is good agreement between the theoretical model and experimental data for the systems defined previously as flashlamp pumped laser oscillator, and the long path length solar pumped laser.

Han, Kwang S.↗

Air-Operated Sump Pump

Pump removes liquid seepage from small, restricted area and against large pressure head. Developed for moving small amounts of water and oil from sump pit 85 ft (25.91 m) deep. Fits in space only 6 1/2 in. (16.5 cm) in diameter and 18 in. (45.7 cm) long. In discharge part of pumping cycle, air forces liquid out of pump chamber through pipe. During filling part of pumping cycle, water enters pump chamber from sump pit. Float in chamber next to pump chamber controls pressurization through timer and solenoid valve.

Nolt, Gary D.↗

Bistable direction switching in an off-axis pumped continuous wave ruby laser

A report is presented of the observation of hysteretic bistable direction switching in a single-mode CW ruby laser system. This effect is only observed when the pump beam which is focused into the ruby rod is misaligned with respect to the rod end faces. At low pump powers, the ruby lases in a mode nearly collinear with the pump axis. At a higher pump power the ruby switches to a mode that is collinear with the rod end faces and preserves the original polarization. The effect is large enough to switch the beam by an angle equal to twice the diffraction angle. The observations show that under steady-state pumping, a CW ruby laser can exhibit bistable operation in its output direction and power. A calculation using the heat equation with two concentric cylinders with one as a heat source (pump laser) and the outer wall of the other held at 77 K, gives an increase in core temperature of about 0.01 K. Therefore, the increase in temperature is not large enough to change the index of refraction to account for such large macroscopic effects.

Afzal, R. Sohrab↗

The magnetic pumping of plasmas with sawtooth waveforms

The pumping of plasmas by sawtooth-waveform magnetic induction variations is studied theoretically and by means of computer simulations. A sawtooth is a cycle waveform that is characterized by a slow increase in the magnetic induction followed by a rapid drop in the induction. Two types of sawtooth pumping are analyzed, and the types classified as to whether or not the first adiabatic invariants of the plasma particles are conserved during the rapid drops in the magnetic induction. When the invariants are conserved, the sawtooth waveforms are found to be less efficient than square waves for pumping plasmas. When the adiabatic invariations are not conserved, the pumping efficiency is found to be a slight improvement over square waves. Both types of pumping are applied to a hypothetical tokamak plasma and it is concluded that neither type of sawtooth pumping is practical for heating magnetically confined fusion plasmas.

Borovsky, Joseph E.↗

Fluctuating pressures in pump diffuser and collector scrolls, part 1

The cracking of scroll liners on the SSME High Pressure Fuel Turbo Pump (HPFTP) on hot gas engine test firings has prompted a study into the nature of pressure fluctuations in centrifugal pump states. The amplitudes of these fluctuations and where they originate in the pump stage are quantified. To accomplish this, a test program was conducted to map the pressure pulsation activity in a centrifugal pump stage. This stage is based on typical commercial (or generic) pump design practice and not the specialized design of the HPFTP. Measurements made in the various elements comprising the stage indicate that pulsation activity is dominated by synchronous related phenomena. Pulsation amplitudes measured in the scroll are low, on the order of 2 to 7 percent of the impeller exit tip speed velocity head. Significant non-sychronous pressure fluctuations occur at low flow, and while of interest to commercial pump designers, have little meaning to the HPFTP experience. Results obtained with the generic components do provide insights into possible pulsation related scroll failures on the HPFTP, and provide a basis for further study.

Sloteman, Donald P.↗