Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Assessing and Reducing Plug and Process Loads in Office Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Assessing and Reducing Plug and Process Loads in Retail Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Office Building Plug Load Disaggregation

This case study focuses on the National Renewable Energy Lab's succesful effort to develop a disaggregated breakdown of device-level power consumption in a zero energy office building by combining smart plug metering with a device inventory.

plug and process loads, PPLs, device-level meterin↗

Plug and Process Loads in Commercial Buildings

This brochure is intended to address gaps in actionable knowledge regarding plug load (PPL) capacities, as prospective building occupants and real estate brokers lack accurate references for PPL capacity requirements.

plug and process loads, PPL, capacity requirements↗

Decision Guides for Plug and Process Loads

This resource provides guidance for building owners to help them select the right control strategy for plug and process loads (PPLs) in their buildings. It includes guidance for multiple different building types and outline the costs, potential savings, complexities, and user friendliness of various control strategies and their applications to each building type.

Plug and Process Load, PPL, Commercial building, S↗

Integrated Controls for Plug Loads and Lighting Systems - Case Study: Minnesota DOT Cedar Avenue Truck Station

This case study highlights the strategies the Minnesota Department of Transportation used at Cedar Avenue Truck Station for integrating plug load and lighting systems. An integrated controls pilot project with retrofit installation was conducted from October 2019 to April 2020 and was recognized by DOE's Integrated Lighting Campaign.

integrated lighting, lighting, controls, plug load↗

Correlating Dynamometer Testing to In-Use Fleet Results of Plug-In Hybrid Electric Vehicles

Standard dynamometer test procedures are currently being developed to determine fuel and electrical energy consumption of plug-in hybrid vehicles (PHEV). To define a repeatable test procedure, assumptions were made about how PHEVs will be driven and charged. This study evaluates these assumptions by comparing results of PHEV dynamometer testing following proposed procedures to actual performance of PHEVs operating in the US Department of Energy’s (DOE) North American PHEV Demonstration fleet. Results show PHEVs in the fleet exhibit a wide range of energy consumption, which is not demonstrated in dynamometer testing. Sources of variation in performance are identified and examined.

33 ADVANCED PROPULSION SYSTEMS↗

U.S. Department of Energy -- Advanced Vehicle Testing Activity: Plug-in Hybrid Electric Vehicle Testing and Demonstration Activities

The U.S. Department of Energy’s (DOE) Advanced Vehicle Testing Activity (AVTA) tests plug-in hybrid electric vehicles (PHEV) in closed track, dynamometer and onroad testing environments. The onroad testing includes the use of dedicated drivers on repeated urban and highway driving cycles that range from 10 to 200 miles, with recharging between each loop. Fleet demonstrations with onboard data collectors are also ongoing with PHEVs operating in several dozen states and Canadian Provinces, during which trips- and miles-per-charge, charging demand and energy profiles, and miles-per-gallon and miles-per-kilowatt-hour fuel use results are all documented, allowing an understanding of fuel use when vehicles are operated in charge depleting, charge sustaining, and mixed charge modes. The intent of the PHEV testing includes documenting the petroleum reduction potential of the PHEV concept, the infrastructure requirements, and operator recharging influences and profiles. As of May 2008, the AVTA has conducted track and dynamometer testing on six PHEV conversion models and fleet testing on 70 PHEVs representing nine PHEV conversion models. A total of 150 PHEVs will be in fleet testing by the end of 2008, all with onboard data loggers. The onroad testing to date has demonstrated 100+ miles per gallon results in mostly urban applications for approximately the first 40 miles of PHEV operations. The primary goal of the AVTA is to provide advanced technology vehicle performance benchmark data for technology modelers, research and development programs, and technology goal setters. The AVTA testing results also assist fleet managers in making informed vehicle purchase, deployment and operating decisions. The AVTA is part of DOE’s Vehicle Technologies Program. These AVTA testing activities are conducted by the Idaho National Laboratory and Electric Transportation Engineering Corporation, with Argonne National Laboratory providing dynamometer testing support. The proposed paper and presentation will discuss PHEV testing activities and results. INL/CON-08-14333

33 ADVANCED PROPULSION SYSTEMS↗

China’s Booming Plug-in Electric Vehicle Market—How Will It Continue?

The plug-in electric vehicle (PEV) is recognized as a pivotal component in transportation energy security and technology innovation in China. With government incentives and substantial capital investments, the Chinese PEV market has become one of the largest in the world. However, is this market boom ephemeral or will it be continuing? This chapter provides a general review of the Chinese PEV market mainly from the consumer per-spective, by summarizing the characteristics of the vehicle policies and consumer concerns in the PEV market in recent years. Moreover, it intro-duces detailed examples on how the policies, technologies, and infrastruc-ture shape the market. In addition to employing large amounts of reliable data from the China Automotive Technology and Research Center for the review, the authors also adopted a quantitative analysis tool—the New Energy and Oil Consumption Credits model—to project the potential in-dustrial impacts of the government policies in multiple scenarios. Based on the findings, it seems that the prosperity of the PEV market, incentivized by the government, will continue in the short run. The direct subsidies to PEV from the government will gradually phase out, and the supply-side push policies such as the dual-credit policy and other charging infrastruc-ture incentives will work as the invisible hand to force the automakers to invest more in the PEV segment. However, in the long run, innovation in PEV technology and business models, together with consumer acceptance will be the major factors that can sustain further market growth.

Ou, Shawn↗

High-Flow Renal Arteriovenous Fistula Treated with the Amplatzer Vascular Plug: Implementation of an Arterial and Venous Approach

We present a 28-year-old man with a large symptomatic arteriovenous fistula (AVF) treated with embolization using the Amplatzer vascular plug (AVP). Although embolization may be considered the first-line therapy in the treatment of AVFs, there is an inherent high risk of migration of the embolic agents into the venous and pulmonary circulations. This case is illustrative of the ease and safety of using this device in high-flow renal AVFs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was also not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of the AMPLATZER Vascular Plug in Endovascular Occlusion of Dialysis Accesses

The purpose of this study was to share our initial experience with the AMPLATZER Vascular Plug (AVP) in occluding dialysis accesses. Between January 2007 and October 2008, five patients with autogenous and one patient with prosthetic accesses were referred for endovascular occlusion owing to central venous obstruction (n = 4) and dialysis-associated steal syndrome (n = 2) leading to disabling complications. We used a single AVP in two patients, double AVPs in two patients, and double AVPs and n-butyl 2-cyanoacrylate in one patient with an autogenous access. Two coils were deployed between two AVPs to occlude the prosthetic graft. Immediate success was achieved in all patients, with no complications. Mean follow-up time was 13 months (range, 1-21 months) and none of the patients had experienced symptom recurrence as of the time of writing. The AVP allows simple, precise, and reliable dialysis access occlusion without significant complications when surgical ligation is not preferred. It can be used with other embolizing agents to provide occlusion in the case of failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Use of the AMPLATZER Vascular Plug: Preventing Bile Leak Following Inadvertent Subcapsular Deployment of a Biliary Stent

The AMPLATZER Vascular Plug (AVP; AGA Medical, USA) is designed to provide optimal embolization of peripheral veins and arteries through single-device occlusion. There are no reported cases of the AVP's being used to prevent bile leak. We report the successful use of the AVP within the liver to prevent intraperitoneal bile leak following inadvertent subcapsular stent deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Embolization of a Spontaneous Mesocaval Shunt Using the Amplatzer Vascular Plug II

A 48-year-old man with alcoholic liver cirrhosis and hepatic encephalopathy was found to have a large, spontaneous mesocaval shunt. The shunt was successfully occluded with the use of an Amplatzer Vascular Plug. To our knowledge, this is the first report of the use of this device to embolize a mesocaval shunt involving the superior mesenteric vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Transjugular and Plugged-Percutaneous Liver Biopsy in Patients with Contraindications to Ordinary Percutaneous Liver Biopsy and an 'In-House' Protocol for Selecting the Procedure of Choice

The purpose of this study was to evaluate the effectiveness and safety of transjugular liver biopsy (TJLB) and plugged-percutaneous liver biopsy (PB) in consecutive patients with severe liver disease associated with impaired coagulation, ascites, or both and to verify the in-house protocol used to select the appropriate procedure. In 2000-2006, 329 patients (208 male [62.8%] and 121 female [37.2%]), aged 1 month to 81 years (mean, 46.8 years), underwent 150 TJLBs (39.1%) or 233 PBs (60.9%) procedures at a major tertiary center, as determined by an in-house protocol. The groups were compared for specimen characteristics, technical success, and complications. Technical success rates were 97.4% for TJLB (146/150) and 99.1% for PB (231/233). TJLB was associated with a lower average core length (1.29 vs. 1.43 cm) and lower average number of specimens obtained (2.44 vs. 2.8), but both methods yielded sufficient tissue for a definitive diagnosis. There were no major complications in either group. TJLB and PB can be safely and effectively performed for the diagnosis of hepatic disease in patients with contraindications for standard percutaneous liver biopsy. When both are technically available, we suggest PB as the procedure of choice, especially in transplanted livers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Experience with the Amplatzer Vascular Plug II for Occlusive Purposes in Arteriovenous Hemodialysis Access

The Amplatzer Vascular Plug Type II (AVP II) has proven effective in the therapeutic embolization of various vascular lesions. It benefits from very rapid occlusion of the target lesion and can be deployed, retrieved, and redeployed if required. There is no literature available on use of the AVP II in the maintenance, closure, and management of complicated arteriovenous access in hemodialysis patients. In this series, we present our clinical experience with the use of the AVP II for embolization of problematic hemodialysis access. The AVP II is a self-expandable Nitinol wire-mesh device. Mounted on a delivery wire it has the capability to be deployed, recaptured, and redeployed. In total seven patients (four males: one diabetic, all nonsmokers), with ages ranging from 44 to 81 years (mean, 63 years), were treated between July 2008 and January 2009. One patient had not started dialysis. The remaining six patients had varied histories, with the time on hemodialysis ranging from 1 to 21 years. Retrospective review of clinical notes revealed patient demographics, type of access, device size, deployment site, and outcomes. Indications for embolization included steal syndrome (one patient), high-flow tributaries (two patients), and limb swelling (four patients). All patients had clinical and sonographical follow-up to 3 months. Surgical ligation had either failed, was considered a contraindication due to concerns regarding wound healing, or was considered difficult due to complex venous anatomy. Only one device was used in each patient, ranging from 6 to 16 mm in diameter. Immediate technical success was seen in 100%. All these patients were followed up clinically in the vascular access radiology clinic at 4 weeks and 3 months. Occlusion of the treated vessel and resolution of symptoms were reconfirmed in 100% of cases at 3 months. It was also noted whether patients were having successful dialysis, if required. There were no complications. Average procedural time was 19 min. We conclude that the AVP II is an efficient, safe, and technically simple occlusion device for use in arteriovenous access.

62 RADIOLOGY AND NUCLEAR MEDICINE↗