Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Electromagnetic Analysis of ITER Diagnostic Equatorial Port Plugs During Plasma Disruptions

ITER diagnostic port plugs perform many functionsincluding structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs), Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Opportunities for Space Station wave experiments

The solar terrestrial observatory (STO) concept is discussed as well as Space Station accommodations for STO. Instruments for the initial STO which can be used to excite and detect waves include the electrodynamic tether, waves in space plasmas, space experiments with particle accelerators, vehicle charge and potential experiments, recoverable plasma diagnostics package, magnetospheric multiprobes, and theoretical and experimental beam plasma physics. An example is given of a typical campaign mode of operation which is appropriate for active experiments.

Shawhan, Stanley D.↗

Analysis of the tuning characteristics of microwave plasma source

In this paper, we present an analysis of the tuning characteristics of waveguide-supplied metal-cylinder-based nozzleless microwave plasma source. This analysis has enabled to estimate the electron concentration n{sub e} and electron frequency collisions ν in the plasma generated in nitrogen and in a mixture of nitrogen and ethanol vapour. The parameters n{sub e} and ν are the basic quantities that characterize the plasma. The presented new plasma diagnostic method is particularly useful, when spectroscopic methods are useless. The presented plasma source is currently used in research of a hydrogen production from liquids.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical Study of Radiation from a Broad Range of Impurity Ions for Magnetic Fusion Diagnostics

Spectroscopy of radiation emitted by impurities plays an important role in the study of magnetically confined fusion plasmas. The measurements of these impurities are crucial for the control of the general machine conditions, for the monitoring of the impurity levels, and for the detection of various possible fault conditions. Low-Z impurities, typically present in concentrations of 1%, are lithium, beryllium, boron, carbon, and oxygen. Some of the common medium-Z impurities are metals such as iron, nickel, and copper, and high-Z impurities, such as tungsten, are present in smaller concentrations of 0.1% or less. Despite the relatively small concentration numbers, the aforementioned impurities might make a substantial contribution to radiated power, and also influence both plasma conditions and instruments. A detailed theoretical study of line radiation from impurities that covers a very broad spectral range from less than 1 Å to more than 1000 Å has been accomplished and the results were applied to the LLNL Electron Beam Ion Trap (EBIT) and the Sustained Spheromak Physics Experiment (SSPX) and to the National Spherical Torus Experiment (NSTX) at Princeton. Though low- and medium-Z impurities were also studied, the main emphasis was made on the comprehensive theoretical study of radiation from tungsten using different state-of-the-art atomic structure codes such as Relativistic Many-Body Perturbation Theory (RMBPT). The important component of this research was a comparison of the results from the RMBPT code with other codes such as the Multiconfigurational Hartree–Fock developed by Cowan (COWAN code) and the Multiconfiguration Relativistic Hebrew University Lawrence Atomic Code (HULLAC code), and estimation of accuracy of calculations. We also have studied dielectronic recombination, an important recombination process for fusion plasma, for variety of highly and low charged tungsten ions using COWAN and HULLAC codes. Accurate DR rate coefficients are needed for describing the ionization balance of plasmas, which in turn determines the lines contributing to the spectral emission and the radiative power loss. In particular, we have calculated relativistic atomic data and corresponding dielectronic satellite spectra of highly ionized W ions, such as, for example, Li-like W (with the shortest wavelength of x-ray radiation of about 0.2 Å) that might exist in ITER core plasmas at very high temperatures of 30-40 keV. In addition, we have completed relativistic calculations of low ionized W ions from Lu-like (W3+) to Er-like (W6+) and for Sm-like(W12+) and Pm-like (W13+) that cover a spectral range from few hundred to thousand Å and are more relevant to the edge plasma diagnostics in tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiparameter measurement utilizing poloidal polarimeter for burning plasma reactor

The authors have made the basic and applied research on the polarimeter for plasma diagnostics. Recently, the authors have proposed an application of multiparameter measurement (magnetic field, B, electron density, n{sub e}, electron temperature, T{sub e}, and total plasma current, I{sub p}) utilizing polarimeter to future fusion reactors. In this proceedings, the brief review of the polarimeter, the principle of the multiparameter measurement and the progress of the research on the multiparameter measurement are explained. The measurement method that the authors have proposed is suitable for the reactor for the following reasons; multiparameters can be obtained from a small number of diagnostics, the proposed method does not depend on time-history, and far-infrared light utilized by the polarimeter is less sensitive to degradation of of optical components. Taking into account the measuring error, performance assessment of the proposed method was carried. Assuming that the error of Δθ and Δε were 0.1° and 0.6°, respectively, the error of reconstructed j{sub φ}, n{sub e} and T{sub e} were 12 %, 8.4 % and 31 %, respectively. This study has shown that the reconstruction error can be decreased by increasing the number of the wavelength of the probing laser and by increasing the number of the viewing chords. For example, By increasing the number of viewing chords to forty-five, the error of j{sub φ}, n{sub e} and T{sub e} were reduced to 4.4 %, 4.4 %, and 17 %, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Four-Barrel Pellet Injection System for the TJ-II Stellarator

A new pellet injection system for the TJ-II stellarator has been developed/constructed as part of a collaboration between the Oak Ridge National Laboratory (ORNL) and the Centro de Investigaciones Energ ticas, Medioambientales y Tecnol gicas (CIEMAT). ORNL is providing most of the injector hardware and instrumentation, the pellet diagnostics, and the pellet transport tubes; CIEMAT is responsible for the injector stand/interface to the stellarator, cryogenic refrigerator, vacuum pumps/ballast volumes, gas manifolds, remote operations, plasma diagnostics, and data acquisition. The pellet injector design is an upgraded version of that used for the ORNL injector installed on the Madison Symmetric Torus (MST). It is a four-barrel system equipped with a cryogenic refrigerator for in situ hydrogen pellet formation and a combined mechanical punch/propellant valve system for pellet acceleration (speeds ~100 to 1000 m/s). On TJ-II, it will be used as an active diagnostic and for fueling. To accommodate the plasma experiments planned for TJ-II, pellet sizes significantly smaller than those typically used for the MST application are required. The system will initially be equipped with four different pellet sizes, with the gun barrel bores ranging between ~0.5 to 1.0 mm. The new system is almost complete and is described briefly here, highlighting the new features added since the original MST injector was constructed. Also, the future installation on TJ-II is reviewed.

diagnostic↗

Integrated Data Analysis to Improve Te and Zeff Measurement on NSTX-U

The multi-energy soft x-ray (ME-SXR) camera is a new concept for a fusion plasma diagnostic based on a pixelated detector with adjustable photon cutoff thresholds. It is a single, compact, solid-state detector which combines spatial and spectral sensitivity and can be configured remotely at run time, making it ideal for a fusion environment. The detector can be configured for application to a wide range of physics problems including impurity transport, electron temperature profiles, and non-thermal effects. The detector has been installed on the Madison Symmetric Torus (MST) as part of a collaboration between Princeton Plasma Physics Laboratory and the University of Wisconsin–Madison to develop the technology and analysis techniques. A full diagnostic forward model of the ME-SXR diagnostic has been developed to enable analysis of the raw photon count data. This model incorporates the atomic physics underlying the plasma emission, diagnostic geometry, and detector response characteristics. Employing this model, a Bayesian analysis approach is used to extract electron temperature from the raw data. This analysis approach uses all available information, clearly quantifies prior information, and handles uncertainties transparently. The ME-SXR camera is being used to study the 3D (helical, stellarator-like) state that forms in the MST device. This helical core structure has improved energy confinement. The transition to the helical state is accompanied by a rise in electron temperature in the central part of the helical structure, but then this enhancement fluctuates. The characteristics of this fluctuation are being compared to a magneto-hydrodynamics model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ion diagnostics and physics at MAST-Upgrade (Final Report)

The main contribution of UCI personnel to MAST-U was installation of the solid-state neutral particle analyzer (SSNPA) diagnostic, which was documented in a 2022 Review of Scientific Instruments article by UCI PhD student Garrett Prechel. Another paper by PI William Heidbrink et al supplied a helpful tool for analysis of the data from the 3 MeV proton diagnostic [Plasma Phys. Cont. Fusion, 2021]. Useful advice was also given concerning the FIDA diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma wave turbulence around the shuttle - Results from the Spacelab-2 flight

During the Spacelab-2 flight, which occurred from July 29, to August 6, 1985, a spacecraft called the Plasma Diagnostics Package (PDP) was released from the shuttle to explore the plasma environment around the shuttle. The plasma wave instrument on the PDP detected a region of intense broadband turbulence around the shuttle at frequencies extending from a few Hz to about 10 kHz. The noise has broadband intensities ranging from 1 to 5 mV/m and was observed at distances of up to 400 m from the shuttle. The highest intensities occurred in the region downstream of the shuttle and along magnetic field lines passing near the shuttle. The intensities also tended to increase during periods of high thruster activity, which provides strong evidence that the noise is caused by an interaction of the ionosphere with gaseous emissions from the shuttle, similar in many respects to the interaction of a comet with the solar wind. Antenna interference patterns observed in the wideband data show that the wavelength of the turbulence is very short, a few meters or less.

Gurnett, D. A.↗

Interference patterns in the Spacelab 2 plasma wave data: Lower hybrid waves driven by pickup ions

During the Spacelab 2 mission the University of Iowa's Plasma Diagnostics Package (PDP) was released from the shuttle to explore the plasma environment around the shuttle. Wideband spectrograms were obtained from the PDP at frequencies from 0 to 30 kHz and distances up to 400 m from the shuttle. The wideband data frequently showed antenna interference patterns when the PDP was on the downstream side of the shuttle. Analysis of these interference patterns allows a determination of the wavelength, the plasma rest frame frequency, the direction of propagation, the power spectrum, and in some cases the location of the source. We concentrate our analysis on interference patterns due to lower hybrid waves: waves which have rest frame frequencies near the lower hybrid frequency and propagate perpendicular to the magnetic field. The waves have an almost flat dispersion relation with frequencies just above the lower hybrid frequency and relatively short wavelengths (1 - 4 m). The observed lower hybrid waves depend strongly on the position of the PDP relative to the shuttle and the magnetic field direction. Our results confirm previous suggestions that the lower hybrid waves are generated primarily in the vicinity of the shuttle and that they are driven by a charge exchange interaction between the ambient ionosphere and a H2O cloud around the shuttle.

Feng, Wei↗

Gas Puff Imaging Diagnostics of Edge Plasma Turbulence in Magnetic Fusion Devices

Gas puff imaging (GPI) is a diagnostic of plasma turbulence which usesa puff of neutral gas at the plasma edge to increase the local visiblelight emission for improved space-time resolution of plasmafluctuations. This paper reviews gas puff imaging diagnostics of edgeplasma turbulence in magnetic fusion research, with a focus on theinstrumentation, diagnostic cross-checks, and interpretationissues. The gas puff imaging hardware, optics, and detectors aredescribed for about 10 GPI systems implemented over the past ~15years. Comparison of GPI results with other edge turbulence diagnosticresults are described and many common features are observed. Severalissues in the interpretation of GPI measurements are discussed, andpotential improvements in hardware and modeling are suggested.

Gas puff imaging↗

Wakefield generation in hydrogen and lithium plasmas at FACET-II: Diagnostics and first beam-plasma interaction results

Plasma wakefield acceleration provides ultrahigh acceleration gradients of tens of GeV/m, providing a novel path toward efficient, compact, TeV-scale linear colliders, and high brightness free electron lasers. Critical to the success of these applications is demonstrating simultaneously high gradient acceleration, high energy transfer efficiency, and preservation of emittance, charge, and energy spread. Experiments at the FACET-II National User Facility at SLAC National Accelerator Laboratory aim to achieve all of these milestones in a single-stage plasma wakefield accelerator, providing a 10 GeV energy gain in a < 1 m plasma with high energy transfer efficiency. Such a demonstration depends critically on diagnostics able to measure emittance with mm mrad accuracy, energy spectra to determine both percent level energy spread, and broadband energy gain and loss, incoming longitudinal phase space, and matching dynamics. This paper discusses the experimental setup at FACET-II, including the incoming beam parameters from the FACET-II linac, plasma sources, and diagnostics developed to meet this challenge. Initial progress on the generation of beam ionized wakes in meter-scale hydrogen gas is discussed as well as commissioning of the plasma sources and diagnostics. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Parametric Thermal and Flow Analysis of ITER Diagnostic Shield Module

As part of the diagnostic port plug assembly, the ITER Diagnostic Shield Module (DSM) is designed to provide mechanical support and the plasma shielding while allowing access to plasma diagnostics. Thermal and hydraulic analysis of the DSM was performed using a conjugate heat transfer approach, in which heat transfer was resolved in both solid and liquid parts, and simultaneously, fluid dynamics analysis was performed only in the liquid part. ITER Diagnostic First Wall (DFW) and cooling tubing were also included in the analysis. This allowed direct modeling of the interface between DSM and DFW, and also direct assessment of the coolant flow distribution between the parts of DSM and DFW to ensure DSM design meets the DFW cooling requirements. Design of the DSM included voids filled with Boron Carbide pellets, allowing weight reduction while keeping shielding capability of the DSM. These voids were modeled as a continuous solid with smeared material properties using analytical relation for thermal conductivity. Results of the analysis lead to design modifications improving heat transfer efficiency of the DSM. Furthermore, the effect of design modifications on thermal performance as well as effect of Boron Carbide will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of plasma density and turbulence near the shuttle orbiter

In August 1985 the University of Iowa's Plasma Diagnostics Package was used in the Spacelab 2 mission to study the plasma environment near the shuttle orbiter. Measurements of the plasma density and the percentage density fluctuations yielded information about the structure of the orbiter's wake. These data appear to be in general agreement with previous shuttle results and with laboratory observations of plasma flow-body interactions.

Tribble, A.↗

The spectrum of NGC 7027

IUE and echelle spectrograph observations of the planetary nebular NGC 7027 are analyzed to obtain nebular plasma diagnostics and chemical abundances. It is found that most of the nebular plasma has a density of about 60,000/cu cm and a temperature of about 14,000 K. The results suggest that the stellar radiation field is greatly enhanced shortward of 130 A because of a dense non-LTE wind. It is found that the chemical composition is that of a normal C-rich object, rather than that of a N-rich object.

Keyes, Charles D.↗

ON THE ACCURACY OF THE DIFFERENTIAL EMISSION MEASURE DIAGNOSTICS OF SOLAR PLASMAS. APPLICATION TO SDO/AIA. II. MULTITHERMAL PLASMAS

Differential emission measure (DEM) analysis is one of the most used diagnostic tools for solar and stellar coronae. Being an inverse problem, it has limitations due to the presence of random and systematic errors. We present in this series of papers an analysis of the robustness of the inversion in the case of SDO/AIA observations. We completely characterize the DEM inversion and its statistical properties, providing all the solutions consistent with the data along with their associated probabilities, and a test of the suitability of the assumed DEM model. While Paper I focused on isothermal conditions, we now consider multithermal plasmas and investigate both isothermal and multithermal solutions. We demonstrate how the ambiguity between noises and multithermality fundamentally limits the temperature resolution of the inversion. We show that if the observed plasma is multithermal, isothermal solutions tend to cluster on a constant temperature whatever the number of passbands or spectral lines. The multithermal solutions are also found to be biased toward near-isothermal solutions around 1 MK. This is true even if the residuals support the chosen DEM model, possibly leading to erroneous conclusions on the observed plasma. We propose tools for identifying and quantifying the possible degeneracy of solutions, thus helping the interpretation of DEM inversion.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-Equilibrium Plasma Interactions with Biomaterials, Biological Solutions and Tissues

Cold atmospheric pressure plasma discharges offer an abundant source of reactive oxygen and nitrogen species (RONS) at room temperature enabling unique interactions with biomaterials, biological solutions and tissues. These interactions particularly with living matter are presently an important intellectual frontier in plasma science with promising potential applications ranging from human health care to advanced biomaterial processing. Exciting case studies have been reported that illustrate the huge potential of cold atmospheric plasma technology in wound healing and cancer treatment. The interaction of plasma with conducting and dielectric biomaterials such as tissue strongly influences the plasma properties. In turn this changes the impact of the plasma on the biomaterial. Particularly in the case of living matter, liquid based solutions are ubiquitous which complicates interfacial processes. The lack of insight into the underlying mechanisms of the interaction of plasma with wounds and tumors is currently a bottleneck for the further development of the technology and gives rise to many interesting scientific questions. This project was focused on plasma properties and kinetics during plasma-biomaterial interactions. Both DC pulsed and RF driven atmospheric pressure plasma jets, extensively used by the plasma community were studied. The bio-interfaces included hydrogel as a tissue model, (saline) solutions, bacteria and virus. Plasma diagnostics used include Thomson scattering, Rayleigh scattering, Raman scattering, (two-photon absorption) laser induced fluorescence, optical emission spectroscopy, absorption spectroscopy, molecular beam mass spectrometry and fast imaging allowing to determine electron densities and temperatures, ionic species, reactive species including radicals, gas temperatures, gas composition, electric fields and solution components transferred to the gas phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗