Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Characterization of silicon photomultipliers at National Nano-Fab Center for PET-MR

The silicon photomultipliers (SiPMs) were fabricated for magnetic resonance compatible positron emission tomography (PET) applications using customized CMOS processes at National NanoFab Center. Each micro-cell consists of a shallow n+/p well junction on a p-type epitaxial wafer and passive quenching circuit was applied. The size of the SiPM is 3 × 3 mm{sup 2} and the pitch of each micro-cell is 65 μm. In this work, several thousands of SiPMs were packaged and tested to build a PET ring detector which has a 60 mm axial and 390 mm radial field of view. I-V characteristics of the SiPMs are shown good uniformity and breakdown voltage is around 20 V. The photon detection efficiency was measured via photon counting method and the maximum value was recorded as 16% at 470 nm. The gamma ray spectrum of a Ge-68 isotope showed nearly 10% energy resolution at 511 keV with a 3 × 3 × 20 mm{sup 3} LYSO crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PET based nanocomposite films for microwave packaging applications

In recent years, changes in life standards have promoted the diffusion of Ready to Cook (RTC) and Ready to Eat (RTE) products for microwave ovens. However, the main limits in microwave (MW) ovens usage are often related to the proper choice of packaging materials suitable for such technology. In fact, packages for microwaveable RTC and RTE foods should ensure adequate preservation of the product before cooking/heating such as high barriers to gases and aromas and adequate control of water vapor transmission. In addition, microwaveable packaging material must be transparent to MW, thermally stable and resistant to the mechanical stress induced by the accumulation in the head space of volatile substances produced during the cooking. Polymeric materials are good candidates for microwaveable packaging thanks to their transparency to MW. In the last years a great interest is devoted to developing innovative solution based on the use of additives or systems that act as susceptors or heating enhancers for improving the characteristics of polymers in cooking/heating in MW ovens. The present work was focused on the production and characterization of nanocomposite copolyester based films suitable for microwaveable food packaging applications. The matrices selected consist in two PET copolymers modified with carbon black (ULTRA STD) and with titanium oxide (ULTRA NA). Nanocomposite co-extruded multilayer films were produced using different percentages (0%, 2% and 4%wt/wt) of Cloisite 20A (C20A). Films were analyzed for evaluating the effect of nanofiller on the morphology and barrier properties. Moreover, to verify the effectiveness of the designed systems in reducing the cooking times of meat products, MW heating tests were carried out on pork meat hamburgers in MW oven at varying supplied powers. The cooking tests have pointed out that the selected matrices are efficient in reducing cooking times and that even low concentration of C20A acts as heating enhancers of PET.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dynamic-compliance and viscosity of PET and PEN

Complex dynamic-compliance and in-phase dynamic-viscosity data are presented and analyzed for PET and PEN advanced polyester substrates used for magnetic tapes. Frequency-temperature superposition is used to predict long-term behavior. Temperature and frequency ranges for the primary glass transition and secondary transitions are discussed and compared for PET and PEN. Shift factors from frequency-temperature superposition are used to determine activation energies for the transitions, and WLF parameters are determined for the polyester substrates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation tool for optical design of PET detector modules including scintillator material and sensor array

The appearance of single photon avalanche diodes (SPADs) in the field of PET detector modules made it necessary to apply more complex optical design methods to refine the performance of such assemblies. We developed a combined simulation tool that is capable to model complex detector structures including scintillation material, light guide, light collection optics and sensor, correctly taking into account the statistical behavior of emission of scintillation light and its absorbance in SPADs. As a validation we compared simulation results obtained by our software and another optical design program. Calculations were performed for a simple PET detector arrangement used for testing purposes. According to the results, deviation of center of gravity coordinates between the two simulations is 0.0195 mm, the average ratio of total counts 1.0052. We investigated the error resulting from finite sampling in wavelength space and we found that 20 nm pitch is sufficient for the simulation in case of the given spectral dependencies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel Front-End ASIC With Post Digital Filtering and Calibration for CZT-Based PET Detector

This paper presents a novel front-end electronics based on a front-end ASIC with post digital filtering and calibration dedicated to CZT detectors for PET imaging. A cascade amplifier based on split-leg topology is selected to realize the charge-sensitive amplifier (CSA) for the sake of low noise performances and the simple scheme of the power supplies. The output of the CSA is connected to a variable-gain amplifier to generate the compatible signals for the A/D conversion. A multi-channel single-slope ADC is designed to sample multiple points for the digital filtering and shaping. The digital signal processing algorithms are implemented by a FPGA. To verify the proposed scheme, a front-end readout prototype ASIC is designed and implemented in 0.35 μm CMOS process. In a single readout channel, a CSA, a VGA, a 10-bit ADC and registers are integrated. Two dummy channels, bias circuits, and time controller are also integrated. The die size is 2.0 mm x 2.1 mm. The input range of the ASIC is from 2000 e{sup -} to 100000 e{sup -}, which is suitable for the detection of the X-and gamma ray from 11.2 keV to 550 keV. The linearity of the output voltage is less than 1 %. The gain of the readout channel is 40.2 V/pC. The static power dissipation is about 10 mW/channel. The above tested results show that the electrical performances of the ASIC can well satisfy PET imaging applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of PhytoPET: A plant imaging PET system

The development and initial evaluation of a high-resolution positron emission tomography (PET) system to image the biodistribution of positron emitting tracers in live plants is underway. The positron emitting {sup 11}CO{sub 2} tracer is used in plant biology research investigating carbon sequestration in biomass, optimization of plant productivity and biofuel development. This PhytoPET design allows flexible arrangements of PET detectors based on individual standalone detector modules built from single 5 cm x 5 cm Hamamatsu H8500 position sensitive photomultiplier tubes. Each H8500 is coupled to a LYSO:Ce scintillator array composed of 48 x 48 elements that are 10 mm thick arranged with a 1.0 mm pitch. An Ethernet based 12-bit flash analog to digital data acquisition system with onboard coincident matrix definition is under development to digitize the signals. The detector modules of the PhytoPET system can be arranged and stacked to accommodate various sized plants and plant structures.

09 BIOMASS FUELS↗

Ethernet-based flash ADC for a plant PET detector system

We have developed a flash analog to digital (ADC) based read out system to be used for a Positron Emission Tomography (PET) system. The custom designed 16 channel 12-bit Ethernet-based flash ADC (EFADC-16) unit operates at 250 MHzls/channel utilizing a gigabit Ethernet interface to parse time-stamped event signals. Each unit allows the user to define a custom coincidence table for triggering. Each EFADC-16 unit can digitize four H8500 position sensitive photomultiplier tubes (PSPMT) equipped with a Jefferson Lab designed 4 channel resistive readout (a total of 16 channels). We present initial performance results of the EFADC-16 with four PET detector modules in a plant biology application to acquire tomographic images of the translocation of {sup 11}C within an oak seedling.

42 ENGINEERING↗

Imaging corn plants with PhytoPET, a modular PET system for plant biology

PhytoPET is a modular positron emission tomography (PET) system designed specifically for plant imaging. The PhytoPET design allows flexible arrangements of PET detectors based on individual standalone detector modules built from single Hamamatsu H8500 position sensitive photomultiplier tubes and pixelated LYSO arrays. We have used the PhytoPET system to perform preliminary corn plant imaging studies at the Duke University Biology Department Phytotron. Initial evaluation of the PhytoPET system to image the biodistribution of the positron emitting tracer {sup 11}C in corn plants is presented. {sup 11}CO{sub 2} is loaded into corn seedlings by a leaf-labeling cuvette and translocation of {sup 11}C-sugars is imaged by a flexible arrangement of PhytoPET modules on each side. The PhytoPET system successfully images {sup 11}C within corn plants and allows for the dynamic measurement of {sup 11}C-sugar translocation from the leaf to the roots.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive Detector Positioning for a Room PET System

Investigating human brain function in response to environmental stimuli requires freely moving humans without attached instrumentation. The RoomPET concept provides a feasible solution for human brain imaging. A RoomPET system is a room that contains an optical head tracking system and PET detectors that move to keep the head in the PET detector field-of-view. As a proof of principle, a small box-size prototype was built to demonstrate feasibility of RoomPET with gantry mechanics, tracking capabilities, and control systems.

Byrd, Brook↗

A Room PET Scanner for Natural Environment Neuroscience Research

A room size PET scanner for neuroscience research is proposed in which subjects can move about freely in a natural environment. This scanner, termed RoomPET, would open new frontiers in the study of dynamic brain function. The key to a feasible system is PET detectors with a limited vertical dimension that may translate up and down to keep the brain in the field of view. Head position can be tracked by an array of video cameras, providing real-time data to guide detector motion and for motion-corrected image reconstruction. For a point in the center of the room and centered within the vertical field of view of the detectors, geometric sensitivity ranges between 4 and 18% for room widths of 2 to 3 m and detectors with vertical dimensions of 15 to 40 cm. Spatial resolution is dominated by annihilation photon non-colinearity due to the large detector separation. This non-colinearity contribution for F-18 is 4.4 and 6.6 mm full width at half maximum (FWHM) at the center of 2 ×2 and 3×3m 2 rooms, respectively, for a line of response orthogonal to the opposite walls. With pixelated scintillation crystal elements 2 mm on a side the system resolution for F-18 radiotracers is estimated at 4.5 and 6.7 mm FWHM for room widths of 2 and 3 m, respectively. A RoomPET system would advance the understanding of brain function in healthy humans and in those with neurological diseases, disorders and brain injury.

Smith, Mark F.↗

Performance of the Tachyon Time-of-Flight PET Camera

We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm 2 side of 6.15 ×6.15 ×25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.

47 OTHER INSTRUMENTATION↗

Combining multiple FDG-PET radiotherapy target segmentation methods to reduce the effect of variable performance of individual segmentation methods

Purpose: Many approaches have been proposed to segment high uptake objects in 18F-fluoro-deoxy-glucose positron emission tomography images but none provides consistent performance across the large variety of imaging situations. This study investigates the use of two methods of combining individual segmentation methods to reduce the impact of inconsistent performance of the individual methods: simple majority voting and probabilistic estimation. Methods: The National Electrical Manufacturers Association image quality phantom containing five glass spheres with diameters 13-37 mm and two irregularly shaped volumes (16 and 32 cc) formed by deforming high-density polyethylene bottles in a hot water bath were filled with 18-fluoro-deoxyglucose and iodine contrast agent. Repeated 5-min positron emission tomography (PET) images were acquired at 4:1 and 8:1 object-to-background contrasts for spherical objects and 4.5:1 and 9:1 for irregular objects. Five individual methods were used to segment each object: 40% thresholding, adaptive thresholding, k-means clustering, seeded region-growing, and a gradient based method. Volumes were combined using a majority vote (MJV) or Simultaneous Truth And Performance Level Estimate (STAPLE) method. Accuracy of segmentations relative to CT ground truth volumes were assessed using the Dice similarity coefficient (DSC) and the symmetric mean absolute surface distances (SMASDs). Results: MJV had median DSC values of 0.886 and 0.875; and SMASD of 0.52 and 0.71 mm for spheres and irregular shapes, respectively. STAPLE provided similar results with median DSC of 0.886 and 0.871; and median SMASD of 0.50 and 0.72 mm for spheres and irregular shapes, respectively. STAPLE had significantly higher DSC and lower SMASD values than MJV for spheres (DSC, p < 0.0001; SMASD, p= 0.0101) but MJV had significantly higher DSC and lower SMASD values compared to STAPLE for irregular shapes (DSC, p < 0.0001; SMASD, p= 0.0027). DSC was not significantly different between 128 Multiplication-Sign 128 and 256 Multiplication-Sign 256 grid sizes for either method (MJV, p= 0.0519; STAPLE, p= 0.5672) but was for SMASD values (MJV, p < 0.0001; STAPLE, p= 0.0164). The best individual method varied depending on object characteristics. However, both MJV and STAPLE provided essentially equivalent accuracy to using the best independent method in every situation, with mean differences in DSC of 0.01-0.03, and 0.05-0.12 mm for SMASD. Conclusions: Combining segmentations offers a robust approach to object segmentation in PET. Both MJV and STAPLE improved accuracy and were robust against the widely varying performance of individual segmentation methods. Differences between MJV and STAPLE are such that either offers good performance when combining volumes. Neither method requires a training dataset but MJV is simpler to interpret, easy to implement and fast.

60 APPLIED LIFE SCIENCES↗

{sup 18}F-FLT uptake kinetics in head and neck squamous cell carcinoma: A PET imaging study

Purpose: To analyze the kinetics of 3{sup ′}-deoxy-3{sup ′}-[F-18]-fluorothymidine (18F-FLT) uptake by head and neck squamous cell carcinomas and involved nodes imaged using positron emission tomography (PET). Methods: Two- and three-tissue compartment models were fitted to 12 tumor time-activity-curves (TACs) obtained for 6 structures (tumors or involved nodes) imaged in ten dynamic PET studies of 1 h duration, carried out for five patients. The ability of the models to describe the data was assessed using a runs test, the Akaike information criterion (AIC) and leave-one-out cross-validation. To generate parametric maps the models were also fitted to TACs of individual voxels. Correlations between maps of different parameters were characterized using Pearson'sr coefficient; in particular the phosphorylation rate-constants k{sub 3-2tiss} and k{sub 5} of the two- and three-tissue models were studied alongside the flux parameters K{sub FLT-2tiss} and K{sub FLT} of these models, and standardized uptake values (SUV). A methodology based on expectation-maximization clustering and the Bayesian information criterion (“EM-BIC clustering”) was used to distil the information from noisy parametric images. Results: Fits of two-tissue models 2C3K and 2C4K and three-tissue models 3C5K and 3C6K comprising three, four, five, and six rate-constants, respectively, pass the runs test for 4, 8, 10, and 11 of 12 tumor TACs. The three-tissue models have lower AIC and cross-validation scores for nine of the 12 tumors. Overall the 3C6K model has the lowest AIC and cross-validation scores and its fitted parameter values are of the same orders of magnitude as literature estimates. Maps ofK{sub FLT} and K{sub FLT-2tiss} are strongly correlated (r = 0.85) and also correlate closely with SUV maps (r = 0.72 for K{sub FLT-2tiss}, 0.64 for K{sub FLT}). Phosphorylation rate-constant maps are moderately correlated with flux maps (r = 0.48 for k{sub 3-2tiss} vs K{sub FLT-2tiss} and r = 0.68 for k{sub 5} vs K{sub FLT}); however, neither phosphorylation rate-constant correlates significantly with SUV. EM-BIC clustering reduces the parametric maps to a small number of levels—on average 5.8, 3.5, 3.4, and 1.4 for K{sub FLT-2tiss}, K{sub FLT}, k{sub 3-2tiss}, and k{sub 5.} This large simplification is potentially useful for radiotherapy dose-painting, but demonstrates the high noise in some maps. Statistical simulations show that voxel level noise degrades TACs generated from the 3C6K model sufficiently that the average AIC score, parameter bias, and total uncertainty of 2C4K model fits are similar to those of 3C6K fits, whereas at the whole tumor level the scores are lower for 3C6K fits. Conclusions: For the patients studied here, whole tumor FLT uptake time-courses are represented better overall by a three-tissue than by a two-tissue model. EM-BIC clustering simplifies noisy parametric maps, providing the best description of the underlying information they contain and is potentially useful for radiotherapy dose-painting. However, the clustering highlights the large degree of noise present in maps of the phosphorylation rate-constantsk{sub 5} and k{sub 3-2tiss}, which are conceptually tightly linked to cellular proliferation. Methods must be found to make these maps more robust—either by constraining other model parameters or modifying dynamic imaging protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction for FDG PET dose extravasations: Monte Carlo validation and quantitative evaluation of patient studies

Purpose: Current procedure guidelines for whole body [18F]fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) state that studies with visible dose extravasations should be rejected for quantification protocols. Our work is focused on the development and validation of methods for estimating extravasated doses in order to correct standard uptake value (SUV) values for this effect in clinical routine. Methods: One thousand three hundred sixty-seven consecutive whole body FDG-PET studies were visually inspected looking for extravasation cases. Two methods for estimating the extravasated dose were proposed and validated in different scenarios using Monte Carlo simulations. All visible extravasations were retrospectively evaluated using a manual ROI based method. In addition, the 50 patients with higher extravasated doses were also evaluated using a threshold-based method. Results: Simulation studies showed that the proposed methods for estimating extravasated doses allow us to compensate the impact of extravasations on SUV values with an error below 5%. The quantitative evaluation of patient studies revealed that paravenous injection is a relatively frequent effect (18%) with a small fraction of patients presenting considerable extravasations ranging from 1% to a maximum of 22% of the injected dose. A criterion based on the extravasated volume and maximum concentration was established in order to identify this fraction of patients that might be corrected for paravenous injection effect. Conclusions: The authors propose the use of a manual ROI based method for estimating the effectively administered FDG dose and then correct SUV quantification in those patients fulfilling the proposed criterion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout

Purpose: Depth encoding detectors are required to improve the spatial resolution and spatial resolution uniformity of small animal positron emission tomography (PET) scanners, as well as dedicated breast and brain scanners. Depth of interaction (DOI) can be measured by using dual-ended readout of lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiodes. Inter-crystal reflectors and crystal surface treatments play important roles in determining the performance of dual-ended detectors. In this paper, the authors evaluated five LSO arrays made with three different intercrystal reflectors and with either polished or unpolished crystal surfaces. Methods: The crystal size in all arrays was 1.5 mm, which is typical of the detector size used in small animal and dedicated breast scanners. The LSO arrays were measured with dual-ended readout and were compared in terms of flood histogram, energy resolution, and DOI resolution performance. Results: The four arrays using enhanced specular reflector (ESR) and Toray reflector provided similar quality flood histograms and the array using Crystal Wrap reflector gave the worst flood histogram. The two arrays using ESR reflector provided the best energy resolution and the array using Crystal Wrap reflector yielded the worst energy resolution. All arrays except the polished ESR array provided good DOI resolution ranging from 1.9 mm to 2.9 mm. DOI resolution improved as the gradient in light collection efficiency with depth (GLCED) increased. The geometric mean energies were also calculated for these dual-ended readout detectors as an alternative to the conventional summed total energy. It was shown that the geometric mean energy is advantageous in that it provides more uniform photopeak amplitude at different depths for arrays with high GLCED, and is beneficial in event selection by allowing a fixed energy window independent of depth. A new method of DOI calculation that improved the linearity of DOI ratio vs depth and simplifies the DOI calibration procedure also was developed and tested. Conclusions: The results of these studies provide useful guidance in selecting the proper reflectors and crystal surface treatments when LSO arrays are used for high-resolution PET applications in small animal scanners or dedicated breast and brain scanners.

60 APPLIED LIFE SCIENCES↗

SU-E-I-07: An Improved Technique for Scatter Correction in PET

Purpose: In positron emission tomography (PET), the single scatter simulation (SSS) algorithm is widely used for scatter estimation in clinical scans. However, bias usually occurs at the essential steps of scaling the computed SSS distribution to real scatter amounts by employing the scatter-only projection tail. The bias can be amplified when the scatter-only projection tail is too small, resulting in incorrect scatter correction. To this end, we propose a novel scatter calibration technique to accurately estimate the amount of scatter using pre-determined scatter fraction (SF) function instead of the employment of scatter-only tail information. Methods: As the SF depends on the radioactivity distribution and the attenuating material of the patient, an accurate theoretical relation cannot be devised. Instead, we constructed an empirical transformation function between SFs and average attenuation coefficients based on a serious of phantom studies with different sizes and materials. From the average attenuation coefficient, the predicted SFs were calculated using empirical transformation function. Hence, real scatter amount can be obtained by scaling the SSS distribution with the predicted SFs. The simulation was conducted using the SimSET. The Siemens Biograph™ 6 PET scanner was modeled in this study. The Software for Tomographic Image Reconstruction (STIR) was employed to estimate the scatter and reconstruct images. The EEC phantom was adopted to evaluate the performance of our proposed technique. Results: The scatter-corrected image of our method demonstrated improved image contrast over that of SSS. For our technique and SSS of the reconstructed images, the normalized standard deviation were 0.053 and 0.182, respectively; the root mean squared errors were 11.852 and 13.767, respectively. Conclusion: We have proposed an alternative method to calibrate SSS (C-SSS) to the absolute scatter amounts using SF. This method can avoid the bias caused by the insufficient tail information and therefore improve the accuracy of scatter estimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-96: A Study About the Influence of ROI Variation On Tumor Segmentation in PET

Purpose: To study the influence of different regions of interest (ROI) on tumor segmentation in PET. Methods: The experiments were conducted on a cylindrical phantom. Six spheres with different volumes (0.5ml, 1ml, 6ml, 12ml, 16ml and 20 ml) were placed inside a cylindrical container to mimic tumors of different sizes. The spheres were filled with 11C solution as sources and the cylindrical container was filled with 18F-FDG solution as the background. The phantom was continuously scanned in a Biograph-40 True Point/True View PET/CT scanner, and 42 images were reconstructed with source-to-background ratio (SBR) ranging from 16:1 to 1.8:1. We took a large and a small ROI for each sphere, both of which contain the whole sphere and does not contain any other spheres. Six other ROIs of different sizes were then taken between the large and the small ROI. For each ROI, all images were segmented by eitht thresholding methods and eight advanced methods, respectively. The segmentation results were evaluated by dice similarity index (DSI), classification error (CE) and volume error (VE). The robustness of different methods to ROI variation was quantified using the interrun variation and a generalized Cohen's kappa. Results: With the change of ROI, the segmentation results of all tested methods changed more or less. Compared with all advanced methods, thresholding methods were less affected by the ROI change. In addition, most of the thresholding methods got more accurate segmentation results for all sphere sizes. Conclusion: The results showed that the segmentation performance of all tested methods was affected by the change of ROI. Thresholding methods were more robust to this change and they can segment the PET image more accurately. This work was supported in part by National Natural Science Foundation of China (NNSFC), under Grant Nos. 60971112 and 61375018, and Fundamental Research Funds for the Central Universities, under Grant No. 2012QN086. Wei Lu was supported in part by the National Institutes of Health (NIH) Grant No. R01 CA172638.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-17: Dependence of 3D/4D PET Quantitative Image Features On Noise

Purpose: Quantitative imaging is a fast evolving discipline where a large number of features are extracted from images; i.e., radiomics. Some features have been shown to have diagnostic, prognostic and predictive value. However, they are sensitive to acquisition and processing factors; e.g., noise. In this study noise was added to positron emission tomography (PET) images to determine how features were affected by noise. Methods: Three levels of Gaussian noise were added to 8 lung cancer patients PET images acquired in 3D mode (static) and using respiratory tracking (4D); for the latter images from one of 10 phases were used. A total of 62 features: 14 shape, 19 intensity (1stO), 18 GLCM textures (2ndO; from grey level co-occurrence matrices) and 11 RLM textures (2ndO; from run-length matrices) features were extracted from segmented tumors. Dimensions of GLCM were 256×256, calculated using 3D images with a step size of 1 voxel in 13 directions. Grey levels were binned into 256 levels for RLM and features were calculated in all 13 directions. Results: Feature variation generally increased with noise. Shape features were the most stable while RLM were the most unstable. Intensity and GLCM features performed well; the latter being more robust. The most stable 1stO features were compactness, maximum and minimum length, standard deviation, root-mean-squared, I30, V10-V90, and entropy. The most stable 2ndO features were entropy, sum-average, sum-entropy, difference-average, difference-variance, difference-entropy, information-correlation-2, short-run-emphasis, long-run-emphasis, and run-percentage. In general, features computed from images from one of the phases of 4D scans were more stable than from 3D scans. Conclusion: This study shows the need to characterize image features carefully before they are used in research and medical applications. It also shows that the performance of features, and thereby feature selection, may be assessed in part by noise analysis.

60 APPLIED LIFE SCIENCES↗