Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARALLEL PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Experimental study of a planar atmospheric-pressure plasma operating in the microplasma regime

Electrical characterization of a nonthermal radio-frequency atmospheric-pressure microplasma in a parallel plate configuration has shown that reducing electrode gap into the submillimeter range increases current and power density at a reduced voltage as compared to similar plasmas at larger electrode gaps which have no gap dependence. Calculation of sheath thickness and electric fields in the sheath and in the bulk demonstrate a dependence on the electrode gap as it is reduced into the submillimeter regime, indicating a distinct regime of operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generalized lattice Boltzmann model for flow through tight porous media with Klinkenberg's effect

We report that gas slippage occurs when the mean free path of the gas molecules is in the order of the characteristic pore size of a porous medium. This phenomenon leads to Klinkenberg's effect where the measured permeability of a gas (apparent permeability) is higher than that of the liquid (intrinsic permeability). A generalized lattice Boltzmann model is proposed for flow through porous media that includes Klinkenberg's effect, which is based on the model of Guo et al. [Phys. Rev. E 65, 046308 (2002)]. The second-order Beskok and Karniadakis-Civan's correlation [A. Beskok and G. Karniadakis, Microscale Thermophys. Eng. 3, 43 (1999) and F. Civan, Transp. Porous Med. 82, 375 (2010)] is adopted to calculate the apparent permeability based on intrinsic permeability and the Knudsen number. Fluid flow between two parallel plates filled with porous media is simulated to validate the model. Simulations performed in a heterogeneous porous medium with components of different porosity and permeability indicate that Klinkenberg's effect plays a significant role on fluid flow in low-permeability porous media, and it is more pronounced as the Knudsen number increases. Lastly, fluid flow in a shale matrix with and without fractures is also studied, and it is found that the fractures greatly enhance the fluid flow and Klinkenberg's effect leads to higher global permeability of the shale matrix.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice Boltzmann approach for complex nonequilibrium flows

We present a lattice Boltzmann realization of Grad's extended hydrodynamic approach to nonequilibrium flows. Here, this is achieved by using higher-order isotropic lattices coupled with a higher-order regularization procedure. The method is assessed for flow across parallel plates and three-dimensional flows in porous media, showing excellent agreement of the mass flow with analytical and numerical solutions of the Boltzmann equation across the full range of Knudsen numbers, from the hydrodynamic regime to ballistic motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Demonstration of a Controllable Electrostatic Molecular Beam Splitter

We experimentally demonstrate a controllable electrostatic beam splitter for guided ND{sub 3} molecules with a single Y-shaped charged wire and a homogeneous bias field generated by a charged metallic parallel-plate capacitor. We study the dependences of the splitting ratio R of the guided ND{sub 3} beam and its relative guiding efficiency {eta} on the voltage difference between two output arms of the splitter. The influences of the molecular velocity v and the cutting position L on the splitting ratio R are investigated as well, and the guiding and splitting dynamic processes of cold molecules are simulated. Our study shows that the splitting ratio R of our splitter can be conveniently adjusted from 10% to 90% by changing {Delta}U from -6 kV to +6 kV, and the simulated results are consistent with our experimental ones.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Nonlinear Standing Waves Excited by Plasma-Series-Resonance-Enhanced Harmonics in Capacitive Discharges

We report the first experimental observation of nonlinear standing waves excited by plasma-series-resonance-enhanced harmonics in low pressure, very high frequency, parallel plate, capacitively coupled plasmas. Furthermore, spatial structures of the harmonics of the magnetic field, measured by a magnetic probe, are in very good agreement with simulations based on a nonlinear electromagnetics model. At relatively low pressure, the nonlinear sheath motion generates high-order harmonics that can be strongly enhanced near the series resonance frequencies. Satisfying certain conditions, such nonlinear harmonics induce radial standing waves, with voltage and current maxima on axis, resulting in center-high plasma density. Excitation of higher harmonics is suppressed at higher pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond Compression Dynamics and Timing Jitter Suppression in a THz-driven Electron Bunch Compressor

Herein we present the first demonstration of THz driven bunch compression and timing stabilization of a relativistic electron beam. Quasi-single-cycle strong field THz radiation is used in a shorted parallel-plate structure to compress a few-fC beam with 2.5 MeV kinetic energy by a factor of 2.7, producing a 39 fs rms bunch length and a reduction in timing jitter by more than a factor of 2 to 31 fs rms. This THz driven technique offers a significant improvement to beam performance for applications like ultrafast electron diffraction, providing a critical step towards unprecedented timing resolution in ultrafast sciences, and other accelerator applications using femtosecond-scale electron beams.

43 PARTICLE ACCELERATORS↗

Unstable Invasion of Sedimenting Granular Suspensions

Here we investigate the development of mobility inversion and fingering when a granular suspension is injected radially between horizontal parallel plates of a cell filled with a miscible fluid. While the suspension spreads uniformly when the suspension and the displaced fluid densities are exactly matched, even a small density difference is found to result in a dense granular front which develops fingers with angular spacing that increase with granular volume fraction and decrease with injection rate. We show that the timescale over which the instability develops is given by the volume fraction dependent settling timescale of the grains in the cell. We then show that the mobility inversion and the nonequilibrium Korteweg surface tension due to granular volume fraction gradients determine the number of fingers at the onset of the instability in these miscible suspensions.

02 PETROLEUM↗

Fission measurements with PPAC detectors using a coincidence technique

A fission detection setup based on Parallel Plate Avalanche Counters (PPAC) has been constructed and used at the CERN n-TOF facility. The setup takes advantage of the coincidence detection of both fission fragments to discriminate the background reactions produced by high energy neutrons and it allows obtaining neutron-induced fission cross section up to 1 GeV. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dielectric and Mechanical Behavior of Thermally Aged EPR/CPE Cable Materials

Power and instrumentation cables play a crucial role in the safe operation of Nuclear Power Plants (NPPs). Thermal and other stressors present in the reactor environment cause the cable materials to degrade. In this work, dielectric and mechanical properties of cable insulation and jacket materials are studied as they are thermally aged, supporting development of non-destructive evaluation sensors for monitoring cable aging. Materials selected for this study are found in certain types of single-core unshielded power cables. These utilize ethylene propylene rubber (EPR)-based insulation material and chlorinated polyethylene (CPE)-based jacket material. Flat mats of these materials were obtained from the cable manufacturer and thermally aged at 140 °C in an air-circulating oven. Elongation-at-break was measured on tensile specimens stamped from the aged mats, and dielectric properties were measured from 100 Hz to 100 kHz using a parallel plate capacitor and precision LCR meter. In the case of aged EPR-based materials, rapid decrease in elongation at break indicating end of useful life was accompanied by a significant increase in dissipation factor, D, measured at 100 kHz. Capacitive measurement of D shows promise, therefore, as a non-destructive indicator of corresponding mechanical property changes in thermally-aged EPR-based insulation materials.

cable aging, nuclear cables, material degradation,↗

Flow Loop Study of ECT-Based Volume Fraction Monitoring in Oil–Water Two-Phase Flows

Measurement of phase volume fractions in water-containing multiphase flows is necessary for the optimization of a host of industrial flow processes. Many water-containing multiphase flows can be classified as either water-dispersed or water-continuous mixtures. A recently developed approach based on Hanai’s mixture formula and utilizing electrical capacitance tomography (ECT) sensors have shown good potential for obtaining water volume fraction estimates in two-phase water-containing flows with different water salinity levels. However, the proposed approach was investigated via controlled experiments restricted to static configurations while, in practice, multiphase flows can be dynamic and unpredictable. In this work, we perform a flow loop study of the proposed ECT-based method for volume fraction estimation in oil–water two-phase flows. Here, we evaluate the performance of the proposed method in both water-dispersed and water-continuous flow regimes by employing different types of capacitive sensors in cylindrical arrangements and parallel-plate rectangular arrangements.

02 PETROLEUM↗

Field-Emission Properties of Vertically Aligned Carbon Nanotube Cathodes of Varying Geometries

This work characterizes the bulk emission properties of carbon nanotube (CNT) forest cathodes fabricated with various geometries. Geometries explored include dense nanotube forests of varying height grown on 5×5 mm silicon (Si) substrates and discrete, patterned CNT pillars fabricated using UV photolithography. Dense forests heights ranged from 526 μ m to 1.41 mm, with packing fraction for dense forest calculated to be 4e10 nanotubes/cm2 based on an average nanotube separation distance of 100 nm for fixed growth dense forests. Patterned sample micro pillar heights ranged from 47 to 393 μ m with pillar widths on tested samples ranging from 250 to 270 μ m . Properties explored include emission current, turn-on field, and emission current performance over time. A parallel plate electron beam diode with a 100- μ m A-K gap and an automated test apparatus were developed to provide a configurable experiment that provides accurate and repeatable measurements for dc, dc sweep, and timed performance testing. Operating voltages for the voltage sweeps spanned from 0 to −350 V. Furthermore, testing has shown evidence of a hysteresis effect on the emission current tied to the applied field history as well as shifting of the turn-on field magnitude throughout the testing period, suggesting a conditioning effect during use. Three separate emission regions in the I–V curves during sweep testing have also been observed. In the geometric study, dense forests and patterned samples were sweep tested up to a peak applied voltage of −250 V, with the taller samples generally performing better. Currents produced in the geometric study from the dense forest emitters ranged from 36.8 to 572.34 μ A , with current densities ranging from 15 to 2.29 mA/cm2. Currents produced from the patterned micropillar emitters ranged from 39.4 to 317.51 μ A , with current densities ranging from 67 to 3 mA/cm2. DC time testing s...

36 MATERIALS SCIENCE↗

Design and Preliminary Experimental Results on a Uniform-Field Test Fixture for Power Flow Experiments

Electrodes that produce a uniform electric field across their surfaces are desired for a variety of high-voltage systems including spark-gap switches and transversely excited atmospheric lasers. Here, the implementation of uniform-field electrodes to a parallel-plate load is described for the study of vacuum power flow under pulsed-power applications. We begin with an overview of general uniform-field geometries, and provide an open-source program that generates these geometries as described by Ernst. Following that, a modification to an existing power-flow experimental platform, that adopts a uniform-field geometry, is introduced and its utility is described. Lastly, preliminary experimental results are presented and future steps are outlined.

Capacitors↗

A Reduced-Boundary-Function Method for Convective Heat Transfer with Axial Heat Conduction and Viscous Dissipation

We introduce a method of solution for the convective heat transfer under forced laminar flow that is confined by two parallel plates with a distance of 2a or by a circular tube with a radius of a. The advection-conduction equation is first mapped onto the boundary. The original problem of solving the unknown field is reduced to seek the solutions of T at the boundary (r=a or r=0, r is the distance from the centerline shown in Fig. 1), i.e. the boundary functions and/or . In this manner, the original problem is significantly simplified by reducing the problem dimensionality from 3 to 2. The unknown field can be eventually solved in terms of these boundary functions. The method is applied to the convective heat transfer with uniform wall temperature boundary condition and with heat exchange between flowing fluids and its surroundings that is relevant to the geothermal applications. Analytical solutions are presented and validated for the steady state problem using the proposed method.

Heat Transport, Convective, Conduction, Multi-scal↗

Preparation of TiO{sub 2} thin films on the inner surface of a quartz tube using atmospheric-pressure microplasma

Titanium dioxide (TiO{sub 2}) thin films were prepared on the inner surface of a quartz tube, with inner and outer diameters of 1 and 3 mm, respectively, using plasma-enhanced chemical vapor deposition with titanium tetraisopropoxide and oxygen (O{sub 2}) as reactants and helium as the carrier gas at atmospheric pressure. A microplasma was generated inside the tube by rf (13.56 MHz) excitation using externally attached parallel-plate electrodes. The characteristics of the deposited films were examined by scanning electron microscopy, x-ray photoelectron spectroscopy, and x-ray diffraction. A typical as-deposited film had an amorphous structure with a smooth surface and was transparent. With increasing O{sub 2} concentration in the plasma gas phase, the deposited film surface was covered with a large number of TiO{sub 2} nanoparticles. However, the deposited films were a mixture of TiO{sub 2} and amorphous carbon and showed rough surface in the absence of O{sub 2} in the source gas. The effects of the O{sub 2} concentration in the plasma gas on the characteristics of the deposited TiO{sub 2} films are discussed on the basis of the analysis of the gas species generated in the plasma using optical emission spectroscopy.

36 MATERIALS SCIENCE↗

Measurement of electron temperatures and electron energy distribution functions in dual frequency capacitively coupled CF{sub 4}/O{sub 2} plasmas using trace rare gases optical emission spectroscopy

Measurements of electron temperatures (T{sub e}) and electron energy distribution functions (EEDFs) in a dual frequency capacitively coupled etcher were performed by using trace rare gas optical emission spectroscopy (TRG-OES). The parallel plate etcher was powered by a high frequency (60 MHz) ''source'' top electrode and a low frequency (13.56 MHz) ''substrate'' bottom electrode. T{sub e} first increased with pressure up to {approx}20 mTorr and then decreased at higher pressures. Increasing the bottom rf power resulted in higher electron temperatures. Electron temperatures in 90% CF{sub 4}+10% O{sub 2} plasmas were similar to those in 80% CF{sub 4}+20% O{sub 2} plasmas. EEDF exhibited bi-Maxwellian characteristics with enhanced high energy tail, especially at pressures >20 mTorr.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and dosimetry of a few leaf electron collimator for energy modulated electron therapy

Despite the capability of energy modulated electron therapy (EMET) to achieve highly conformal dose distributions in superficial targets it has not been widely implemented due to problems inherent in electron beam radiotherapy such as planning dosimetry accuracy, and verification as well as a lack of systems for automated delivery. In previous work we proposed a novel technique to deliver EMET using an automated 'few leaf electron collimator' (FLEC) that consists of four motor-driven leaves fit in a standard clinical electron beam applicator. Integrated with a Monte Carlo based optimization algorithm that utilizes patient-specific dose kernels, a treatment delivery was incorporated within the linear accelerator operation. The FLEC was envisioned to work as an accessory tool added to the clinical accelerator. In this article the design and construction of the FLEC prototype that match our compact design goals are presented. It is controlled using an in-house developed EMET controller. The structure of the software and the hardware characteristics of the EMET controller are demonstrated. Using a parallel plate ionization chamber, output measurements were obtained to validate the Monte Carlo calculations for a range of fields with different energies and sizes. Further verifications were also performed for comparing 1-D and 2-D dose distributions using energy independent radiochromic films. Comparisons between Monte Carlo calculations and measurements of complex intensity map deliveries show an overall agreement to within {+-}3%. This work confirms our design objectives of the FLEC that allow for automated delivery of EMET. Furthermore, the Monte Carlo dose calculation engine required for EMET planning was validated. The result supports the potential of the prototype FLEC for the planning and delivery of EMET.

61 RADIATION PROTECTION AND DOSIMETRY↗

An absorbed dose to water standard for HDR {sup 192}Ir brachytherapy sources based on water calorimetry: Numerical and experimental proof-of-principle

Water calorimetry is an established technique for absorbed dose to water measurements in external beams. In this paper, the feasibility of direct absorbed dose measurements for high dose rate (HDR) iridium-192 ({sup 192}Ir) sources using water calorimetry is established. Feasibility is determined primarily by a balance between the need to obtain sufficient signal to perform a reproducible measurement, the effect of heat loss on the measured signal, and the positioning uncertainty affecting the source-detector distance. The heat conduction pattern generated in water by the Nucletron microSelectron-HDR {sup 192}Ir brachytherapy source was simulated using COMSOL MULTIPHYSICSTM software. Source heating due to radiation self-absorption was calculated using EGSnrcMP. A heat-loss correction k{sub c} was calculated as the ratio of the temperature rise under ideal conditions to temperature rise under realistic conditions. The calorimeter setup used a parallel-plate calorimeter vessel of 79 mm diameter and 1.12 mm thick front and rear glass windows located 24 mm apart. Absorbed dose was measured with two sources with nominal air kerma strengths of 38 000 and 21 000 U, at source-detector separations ranging from 24.7 to 27.6 mm and irradiation times of 36.0 to 80.0 s. The preliminary measured dose rate per unit air kerma strength of (0.502{+-}0.007) {mu}Gy/(s U) compares well with the TG-43 derived 0.505 {mu}Gy/(s U). This work shows that combined dose uncertainties of significantly less than 5% can be achieved with only modest modifications of current water calorimetry techniques and instruments. This work forms the basis of a potential future absolute dose to water standard for HDR {sup 192}Ir brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗