Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Orientation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Spatial orientation and balance control changes induced by altered gravitoinertial force vectors

To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

Clinical Trial↗

Orientation processing mechanisms revealed by the plaid tilt illusion

The tilt after-effect (TAE) and tilt illusion (TI) have revealed a great deal about the nature of orientation coding of 1-dimensional (1D) lines and gratings. Comparatively little research however has addressed the mechanisms responsible for encoding the orientation of 2-dimensional (2D) plaid stimuli. A multi-stage model of edge detection has recently been proposed [Georgeson, M. A. (1998) Image & Vision Computing, 16(6-7), 389-405] to account for the perceived structure of a plaid stimulus that incorporates extraction of the zero-crossings (ZCs) of the plaid. Data is presented showing that the ZCs of a plaid inducing stimulus can interact with vertical grating test stimulus to induce a standard tilt illusion. However, by considering the second-order structure of a plaid rather than ZCs, it was shown that the perceived orientation of the vertical test grating results from the combination of orientation illusions due to the first- and second-order components of an inducing plaid. The data suggest that the mechanisms encoding the orientation of second-order contours are similar to, and interact directly with, those that encode first-order contours.

Orientation/physiology↗

Relationship between selected orientation rest frame, circular vection and space motion sickness

Space motion sickness (SMS) and spatial orientation and motion perception disturbances occur in 70-80% of astronauts. People select "rest frames" to create the subjective sense of spatial orientation. In microgravity, the astronaut's rest frame may be based on visual scene polarity cues and on the internal head and body z axis (vertical body axis). The data reported here address the following question: Can an astronaut's orientation rest frame be related and described by other variables including circular vection response latencies and space motion sickness? The astronaut's microgravity spatial orientation rest frames were determined from inflight and postflight verbal reports. Circular vection responses were elicited by rotating a virtual room continuously at 35 degrees/s in pitch, roll and yaw with respect to the astronaut. Latency to the onset of vection was recorded from the time the crew member opened their eyes to the onset of vection. The astronauts who used visual cues exhibited significantly shorter vection latencies than those who used internal z axis cues. A negative binomial regression model was used to represent the observed total SMS symptom scores for each subject for each flight day. Orientation reference type had a significant effect, resulting in an estimated three-fold increase in the expected motion sickness score on flight day 1 for astronauts who used visual cues. The results demonstrate meaningful classification of astronauts' rest frames and their relationships to sensitivity to circular vection and SMS. Thus, it may be possible to use vection latencies to predict SMS severity and duration.

short duration↗

Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs

Tubes made from biaxially oriented liquid-crystal polymers (LCPs) have been developed for use as penetrations on cryogenic tanks. ( Penetrations in this context denotes feed lines, vent lines, and sensor tubes, all of which contribute to the undesired conduction of heat into the tanks.) In comparison with corresponding prior cryogenic-tank penetrations made from stainless steels and nickel alloys, the LCP penetrations offer advantages of less weight and less thermal conduction. An additional major advantage of LCP components is that one can tailor their coefficients of thermal expansion (CTEs). The estimated cost of continuous production of LCP tubes of typical sizes is about $1.27/ft ($4.17/m) [based on 1998 prices]. LCP tubes that are compatible with liquid oxygen and that feature tailored biaxial molecular orientation and quasi-isotropic properties (including quasi-isotropic CTE) have been fabricated by a combination of proprietary and patented techniques that involve the use of counterrotating dies (CRDs). Tailoring of the angle of molecular orientation is what makes it possible to tailor the CTE over a wide range to match the CTEs of adjacent penetrations of other tank components; this, in turn, makes it possible to minimize differential-thermal expansion stresses that arise during thermal cycling. The fabrication of biaxially oriented LCP tubes by use of CRDs is not new in itself. The novelty of the present development lies in tailoring the orientations and thus the CTEs and other mechanical properties of the LCPs for the intended cryogenic applications and in modifications of the CRDs for this purpose. The LCP tubes and the 304-stainless-steel tubes that the LCP tubes were intended to supplant were tested with respect to burst strength, permeability, thermal conductivity, and CTE.

Rubin, Leslie↗

An Orbiting Sample Capture and Orientation System Architecture for Potential Mars Sample Return

An orbiting sample capture and orientation system architecture for a Rendezvous and Orbiting Sample Capture System (ROCS) concept was developed to enable spacecraft based, in-orbit capture, orientation, and transfer of a Mars sample container into a containment vessel as part of a potential Mars Sample Return (MSR) campaign. An analysis of the system functions, requirements, interactions, and constraints was performed. A trade study was carried out on relevant technologies, and a set of evaluation criteria was developed to help determine the most feasible concepts for implementation. The Mars Capture and Re-orientation for the potential Next Mars Orbiter (MACARONE) concept is proposed as a promising system architecture for the ROCS Capture and Orient Module (COM). The concept uses a sliding trap door for Orbiting Sample (OS) capture, a Motorized Cups Mechanism for OS orientation, and a 2 DOF Turret Arm with a paddle for transferring the OS into a containment vessel. This approach facilitates modularity, development flexibility, test-ability in a 1G environment, analyze-ability without the need to simulate or test for 0G contact dynamics, ability to encapsulate potential dust surrounding the OS, and ability to be ejected to reduce the probability of Earth exposure to non-sterilized Mars material.

Lalla, Karan↗

Concept for an On-orbit Capture and Orientation Module for Potential Mars Sample Return

An orbiting sample Capture and Orient Module (COM) architecture for a Capture, Contain, and Return System (CCRS) payload concept for an Earth Return Orbiter (ERO) was developed to enable on-orbit capture, orientation, and transfer of a Mars sample container into a containment vessel for potential Mars Sample Return (MSR). The module is composed of a capture mechanism for containing the Orbiting Sample (OS), a capture cone to capture and contain the OS, an orientation mechanism to orient the OS, an External Transfer Mechanism (ETM) to cage the OS during capture and assemble it into the containment vessel, a capture trigger to trigger capture mechanism and ETM closure during OS capture, and a sensing system to inspect the OS and confirm capture and orientation. Statistical modeling and simulations of the OS during capture were performed to analyze the time to contact and perturbations to the spacecraft at first contact. A half-scale functional prototype of the module was developed to demonstrate end-to-end operation.

Younse, Paulo↗

An Overset Grid Motion Driver for Resolving Entry Vehicle CFD Simulations with Large Changes in Wake Orientation

Time-accurate computational fluid dynamics (CFD) simulations using overset meshes can enable reduced computational cost compared to a rigid, monolithic mesh for blunt-body atmospheric entry vehicles. If the vehicle has a significant change in attitude, the high-density region of the overset mesh designed for resolving the subsonic wake can be kept in position as the wake orientation changes relative to the body. Current simulations generally keep the wake mesh fixed in attitude while the body rotates, assuming the wake orientation remains relatively constant. However, changes in the relative velocity over a long-duration simulation or effects of the body geometry can invalidate this assumption. This work presents a method for calculating the desired mesh orientation to resolve a blunt body wake using the atmosphere-relative velocity of the vehicle. A motion driver using these calculations is implemented in a CFD-in-the-loop flight model bridging the FUN3D flow solver and POST2 trajectory propagator. Overset meshing is performed using the Yoga extension for FUN3D. Results are presented for simulations with both overset and monolithic meshes under large changes in relative velocity (and therefore wake orientation). The results demonstrate that the motion driver successfully orients an overset wake mesh to capture the subsonic wake with sufficient resolution despite variable body rotation and body-relative freestream velocity.

CFD↗

An Overset Grid Motion Driver for Resolving Entry Vehicle CFD Simulations with Large Changes in Wake Orientation

Time-accurate computational fluid dynamics (CFD) simulations using overset meshes can enable reduced computational cost compared to a rigid, monolithic mesh for blunt-body atmospheric entry vehicles. If the vehicle has a significant change in attitude, the high-density region of the overset mesh designed for resolving the subsonic wake can be kept in position as the wake orientation changes relative to the body. Current simulations generally keep the wake mesh fixed in attitude while the body rotates, assuming the wake orientation remains relatively constant. However, changes in the relative velocity over a long-duration simulation or effects of the body geometry can invalidate this assumption. This work presents a method for calculating the desired mesh orientation to resolve a blunt body wake using the atmosphere-relative velocity of the vehicle. A motion driver using these calculations is implemented in a CFD-in-the-loop flight model bridging the FUN3D flow solver and POST2 trajectory propagator. Overset meshing is performed using the Yoga extension for FUN3D. Results are presented for simulations with both overset and monolithic meshes under large changes in relative velocity (and therefore wake orientation). The results demonstrate that the motion driver successfully orients an overset wake mesh to capture the subsonic wake with sufficient resolution despite variable body rotation and body-relative freestream velocity.

Computational Fluid Dynamics↗

Fiber Orientation Evaluation in Reinforced Composites using Digital Image Correlation

This paper presents an innovative nondestructive evaluation (NDE) approach to evaluate fiber orientation in fiber reinforced composites utilizing digital image correlation (DIC). Fiber orientation is a crucial factor that influences the mechanical and thermal properties of the composite. Conventional methods for fiber orientation evaluation and measurement are either destructive, which are typically laborious. NDE methods such as micro computed tomography are expensive and limited in sample size. In this work, we evaluate two methods of excitation of the composite, namely-quasistatic mechanical loading and thermal cycling. Digital Image Correlation (DIC) has been employed in conjunction for fiber orientation measurements. The DIC system is able to measure the fiber orientation by capturing 19x higher strain in the transverse direction of the reinforced fiber axis during excitation. The larger strain occurs in the transverse direction due to larger elongation in the surrounding polymer matrix than the fiber which resists elongation. This innovative method is within the preliminary stage and has been developed to fill the gap/limitations of other NDE methods.

Spencer, Ryan↗

Heating-freezing effects on the orientation of kaolin clay particles

The effects of temperature changes on the particle orientation of a consolidated kaolin are studied using XRD experiments. Here, two sets of equipment were utilized in this study: a benchtop equipment, and a synchrotron beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory. The kaolin specimens tested in the benchtop XRD were subjected to elevated and freezing temperatures ex-situ, while those used for the NSLS-II experiment were exposed to the temperature changes in-situ. The temperatures considered in this study range from freezing (-10 °C) to elevated temperature below boiling (90 °C). The thermally-induced reorientation of clay mineral particles is highly dependent on the relative orientation of the clay mineral particles with respect to the applied thermal gradient. For example, kaolin samples with kaolinite particles oriented perpendicular to the thermal gradient, and to the expected thermally-induced pore water flow, experience much higher particles reorientations compared to samples with particles initially oriented parallel to the thermal gradient. Lastly, freezing kaolin preserved its microstructure as ice crystals form.

36 MATERIALS SCIENCE↗

Fiber Length and Orientation in Long-Fiber Injection-Molded Thermoplastics. Part I: Modeling of Microstructure and Elastic Properties

This paper investigates the effects of fiber length and orientation distributions on the elastic properties of long-fiber injection-molded thermoplastics (LFTs). The corrected experimental fiber length distribution and the predicted and experimental orientation distributions were used in modeling to compute the elastic properties of the composite. First, from the fiber length distribution (FLD) data in terms of number of fibers versus fiber length, the probability density functions were built and used in the computation. Also, it has been shown that the two-parameter Weibull’s distribution can be used to represent the actual FLD. Next, the Mori-Tanaka model that employs the Eshelby’s equivalent inclusion method was applied to calculate the stiffness matrix of the aligned fiber composite containing the established FLD. The stiffness of the actual as-formed composite was then determined from the stiffness of the computed aligned fiber composite that was averaged over all possible orientations using the orientation averaging method. The methodology to predict the elastic properties of LFTs was validated via experimental verification of the longitudinal and transverse moduli determined for long glass fiber injection-molded polypropylene specimens. Finally, a sensitivity analysis was conducted to determine the effect of a variation of FLD on the composite elastic properties.

36 MATERIALS SCIENCE↗

EGS Collab/SIGMA-V Testbed-1 well locations and orientations.

The EGS Collab is conducting experiments in hydraulic fracturing at a depth of 1.5 km in the Sanford Underground Research Facility (SURF) on the 4850 Level. A total of eight ~60m-long subhorizontal boreholes were drilled at that depth on the western rib of the West Access Drift. Six of these holes are used for geophysical monitoring, one is used for hydraulic fracturing and the remaining hole was designed as a production borehole. In addition to these eight boreholes, 4 5-m Jack leg boreholes were drilled for housing geophones. This submission package includes well head locations, total lengths of boreholes, their orientations (gyro data). The reported boreholes orientation data were primarily obtained with REFLEX GYRO (TM) survey right after the completion of each hole. Gyro based orientations were later verified and refined with the results of magnetic orientation survey. Well head locations were ascertained by Laser/Lider survey of the drift around the Testbed.

15 GEOTHERMAL ENERGY↗

Controlling domain orientation of liquid crystalline block copolymer in thin films through tuning mesogenic chemical structures

Controlling the macroscopic orientation of nanoscale periodic structures of amphiphilic liquid crystalline block copolymers (LC BCPs) is important to a variety of technical applications (e.g., lithium conducting polymer electrolytes). To study LC BCP domain orientation, a series of LC BCPs containing a poly(ethylene oxide) (PEO) block as a conventional hydrophilic coil block and LC blocks containing azobenzene mesogens is designed and synthesized. LC ordering in thin films of the BCP leads to the formation of highly ordered, microphase-separated nanostructures, with hexagonally arranged PEO cylinders. Substitution on the tail of the azobenzene mesogen is shown to control the orientation of the PEO cylinders. When the substitution on the mesogenic tails is an alkyl chain, the PEO cylinders have a perpendicular orientation to the substrate surface, provided the thin film is above a critical thickness value. In contrast, when the substitution on the mesogenic tails has an ether group the PEO cylinders assemble parallel to the substrate surface regardless of the film thickness value.

azobenzene mesogen↗

Grain Orientation Dependence of the Residual Lattice Strain in a Cold Rolled Interstitial-Free Steel

The experimentally measured grain-orientation-dependent residual lattice strains, evolved in an interstitia-free steel after 70% cold rolling reduction, are studied by means of crystal elastic visco-plastic finite element simulations, which provides a very satisfactory prediction of deformation texture. The calculated residual lattice strain pole figure matches well with the experimentally measured counterpart within the highest density regions of major texture components observed. Both experimental evidence and results of modeling clearly indicate that the residual lattice strain is orientation dependent, based on comprehensive information on the evolution of residual lattice strain in various crystallographic orientations during plastic deformation. It appears that in a cold rolled material, there is a general correlation between the stresses developed just prior to unloading and the residual lattice strains in particular directions. Here, it is also shown that the cumulative plastic shear does not reveal a clear correlation with the components of residual lattice strain while presented in the normal correlation plot, however, this relationship can be better understood by means of the orientation distribution function of residual lattice strain, which can be derived from the neutron or X-ray diffraction experiments.

36 MATERIALS SCIENCE↗

X-ray Scattering Measurements of Particle Orientation in a Sheared Polymer/Clay Dispersion

We report steady and transient measurements of particle orientation in a clay dispersion subjected to shear flow. An organically modified clay is dispersed in a Newtonian polymer matrix at a volume fraction of 0.02, using methods previously reported by Mobuchon et al. (Rheol Acta 46: 1045, 2007). In accord with prior studies, mechanical rheometry shows yield stress-like behavior in steady shear, while time dependent growth of modulus is observed following flow cessation. Measurements of flow-induced orientation in the flow-gradient plane of simple shear flow using small-angle and wide-angle X-ray scattering (SAXS and WAXS) are reported. Both SAXS and WAXS reveal increasing particle orientation as shear rate is increased. Partial relaxation of nanoparticle orientation upon flow cessation is well correlated with time-dependent changes in complex modulus. SAXS and WAXS data provide qualitatively similar results; however, some quantitative differences are attributed to differences in the length scales probed by these techniques.

36 MATERIALS SCIENCE↗

Tungsten Blister Formation Kinetic as a Function of Fluence, Ion Energy and Grain Orientation Dependence Under Hydrogen Plasma Environment

This work deals with the formation kinetic of tungsten (W) blisters under smooth plasma conditions, i.e. low hydrogen flux and energy in order to analyze the first stages of their formation. In addition, we focus on determining the W grain orientation where blisters grow preferentially. For this purpose, mirror-polished polycrystalline tungsten samples were exposed to hydrogen plasma under fixed hydrogen flux of 2.2 × 10{sup 20} m{sup −2} s{sup −1}, with a fluence in the range of ~ 10{sup 24} m{sup −2}, ion energy of ~ 20, 120 and 220 eV, and sample surface temperature of ~ 500 K. The formation of blisters at the surface was investigated using SEM, AFM and EBSD to determine the size, the distribution and the orientation of grain where blisters are formed, respectively. The critical fluence for initiating blisters was established around 2.3 × 10{sup 24} m{sup −2}. The evolution of blister size distribution and density is discussed as function of fluence and ion energy. At lower ion energy, i.e. 20 eV, only nanoblisters (less than 150 nm) are observed whatever the fluence value (1.5 and 2.3 × 10{sup 24} m{sup −2}). At higher ion energy i.e. 120 and 220 eV, micrometric (~ few to tens of µm) blisters are observed and their density highly depends on fluence. We show that blisters can also be formed on (001) oriented grains contrarily to previous results from the literature where the (111) orientation seemed more favorable. Such information is of importance for tungsten based fusion tokamak operation and design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear dichroism of DNA: Characterization of the orientation distribution function caused by hydrodynamic shear

Linear dichroism provides information on the orientation of chromophores part of, or bound to, an orientable molecule such as DNA. For molecular alignment induced by hydrodynamic shear, the principal axes orthogonal to the direction of alignment are not equivalent. Thus, the magnitude of the flow-induced change in absorption for light polarized parallel to the direction of flow can be more than a factor of two greater than the corresponding change for light polarized perpendicular to both that direction and the shear axis. The ratio of the two flow-induced changes in absorption, the dichroic increment ratio, is characterized using the orthogonal orientation model, which assumes that each absorbing unit is aligned parallel to one of the principal axes of the apparatus. The absorption of the alienable molecules is characterized by components parallel and perpendicular to the orientable axis of the molecule. The dichroic increment ratio indicates that for the alignment of DNA in rectangular flow cells, average alignment is not uniaxial, but for higher shear, as produced in a Couette cell, it can be. The results from the simple model are identical to tensor models for typical experimental configuration. Approaches for measuring the dichroic increment ratio with modern dichrometers are further discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Preferred orientation of calcium aluminosilicate hydrate compacts: Implications for creep and indentation

Nano/micro-indentation has been extensively used to examine elastic properties and creep of cement-based materials. However, there have been inconsistencies in the measured elastic moduli and debate on the creep mechanism of calcium (alumino) silicate hydrates (C-(A-)S-H). To bring new insights, we examined the deviatoric stress-induced preferred orientation of calcium aluminosilicate hydrate (C-A-S-H), portlandite, and ettringite compacts, using synchrotron-based X-ray diffraction. Intense preferred orientations were observed in C-A-S-H compacts, and the c-axis of unit cells is highly aligned with the compression direction; weaker c-axis related fiber-type texture formed in portlandite and ettringite. Higher humidity, greater compacting pressure, and/or increased duration of the pressure intensified the C-A-S-H preferred orientation, which is facilitated by gel-pore water lubrication. This pressure-induced time-dependent preferential re-orientation of crystallites can contribute to the creep of cement-based materials, and it may cause overrepresentation of the soft c-axis of C-(A-)S-H unit-cell in nanoindentation experiments and underestimation of Young's modulus.

36 MATERIALS SCIENCE↗