Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Data Reproducibility of Spin-Echo Small-Angle Neutron Scattering Instruments

Spin-echo small-angle neutron scattering (SESANS) is a unique method to measure structures of materials in real space with length scales from ∼ 30 μm to ∼20 µm. As shown in Figure 1, the accessible length scale of SESANS is given by its ability to encode the momentum transfer into the Larmor phase, namely Φ = $\vec{𝛿}$ ⋅ $\vec{𝑄}$, where $\vec{𝑄}$ is the momentum transfer and $\vec{𝛿}$ is the encoding vector of the setup and its projection along Q (δQ) is called spin-echo length (SEL). The spin echo length, which is synonymous with the spatial correlation distance probed, is defined as the following 𝛿𝑄 ∝ 𝜆 2 𝐵𝐿cot𝜃 where 𝜆 is neutron wavelength, B is magnetic field, L is length of the parallelogram magnetic field region, and 𝜃 is the angle between the inclined magnetic field boundary and the beam direction, as shown in Figure 1. The result of the SESANS experiment is a Hankel transformation of the SANS scattering function I(Q), which yields the correlation function of the sample in real space.

47 OTHER INSTRUMENTATION↗

Desmearing small-angle scattering data by central moment expansions of instrument resolution

This study introduces an enhanced numerical technique tailored specifically for refining 1D small-angle scattering (SAS) intensity profiles affected by smearing. Our primary objective is to address the resolution blurring commonly encountered in SAS data, particularly in systems with clearly defined correlation peaks whose spread aligns with the width of the resolution function at corresponding Q positions. Unlike previous approaches that expanded the SAS intensity using central moment expansion, the new method focuses on expanding the resolution function itself, thus eliminating artificial oscillations observed in smeared spectra due to limitations inherent in our earlier algorithm. This method is straightforward to implement, computationally efficient and consistently performs well in numerical benchmarking. To illustrate its effectiveness, we present a case study of a lamellar phase characterized by distinct peaks in its small-angle neutron scattering intensities.

central moment expansions↗

Insufficient reporting of x-ray photoelectron spectroscopy instrumental and peak fitting parameters (metadata) in the scientific literature

This study was motivated by earlier observations. It is a systematic examination of the adequacy of reporting of information (metadata) necessary to understand x-ray photoelectron spectroscopy (XPS) data collection and data analysis in the scientific literature. The information for this study was obtained from papers published in three high-quality journals over a six-month period in 2019 and throughout 2021. Each paper was evaluated to determine whether the authors had reported (percentages of the papers properly providing the information are given in parentheses) the spectrometer (66%), fitting software (15%), x-ray source (40%), pass energy (10%), spot size (5%), synthetic peak shapes in fits (10%), backgrounds in fits (10%), whether the XPS data are shown in the main body of the paper or in the supporting information (or both), and whether fitted or unfitted spectra were shown (80% of published spectra are fit). The Shirley background is the most widely used background in XPS peak fitting. The Al Kα source is the most widely used x-ray source for XPS data collection. CASAXPS is the most widely used fitting program for XPS data analysis. Further, there is good agreement between the results gathered during the two years of our survey. There are some hints the situation may be improving. This study also provides a list of the information/parameters that should be reported when XPS is performed.

47 OTHER INSTRUMENTATION↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Safety-Related Instrumentation and Control Upgrade Pilot Project: NUREG- 0711 Process Development, Planning and Analysis Activities, and Lessons Learned

Constellation Energy and the United States Department of Energy (DOE) have established a public/private partnership to implement a pilot digital upgrade to replace legacy analog, safety-related reactor protection and emergency safety feature actuation systems (RPS/ESFAS) with modern digital systems. This effort is occurring at Constellation’s Limerick Generating Station. This project is being performed in accordance with industry processes that have been adapted to better support digital upgrades. These processes include IP-ENG-001, Standard Design Process, NISP-EN-04, Standard Digital Engineering Process and Electric Power Research Institute Report 3002011816, Digital Engineering Guide. The Light Water Reactor Sustainability (LWRS) Program at the Idaho National Laboratory (INL) has been supporting this effort. Latest INL HFE efforts in support of this project have focused on definition and implementation of the Human Factors Engineering (HFE) Program in support of Constellation design and related licensing efforts. This paper presents the development execution of the HFE Program through completion of the Planning and Analysis Phase as defined by NUREG-0711 as well as HFE lessons learned.

99 GENERAL AND MISCELLANEOUS↗

Microwave Radiometer – 3-Channel (MWR3C) Instrument Handbook

The microwave radiometer 3-channel (MWR3C) provides time-series measurements of brightness temperatures from three channels centered at 23.834, 30, and 89 GHz. These three channels are sensitive to the presence of liquid water and precipitable water vapor.

47 OTHER INSTRUMENTATION↗

Laser Disdrometer (LDIS) Instrument Handbook

The second-generation particle size velocity (Parsivel2, Figure 1) disdrometer, or laser disdrometer, referred to as “LDIS” within the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) User Facility, is a modern, laser-based disdrometer designed for comprehensive and reliable measurement of all types of precipitation. LDIS captures detailed information on the size and velocity of individual hydrometeors that fall to the ground, classifying them into a range of 32 categories. These raw measurements are processed by a fast signal processor (provided by the vendor) to calculate various parameters, including precipitation type, amount, intensity, kinetic energy, visibility in the precipitation, and equivalent radar reflectivity. These measurements have served as the primary data set and a valuable reference for a variety of studies, ranging from observational analyses of precipitation processes and climate model evaluations to monitoring or validating radar/satellite retrievals (e.g., Wang et al. 2018, Giangrande et al. 2019, Jackson et al. 2020).

47 OTHER INSTRUMENTATION↗

AmeriFlux Measurement Component Instrument Handbook

An AMC system was installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s North Slope Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling PAR sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape. The soil VWC and temperature sensors used at NSA C1 are the Campbell Scientific CS650L and the sensors at NSA M1 use the Campbell Scientific CS655. The two sensors are nearly identical in function, and vendor specifications are based on the CS650 unless otherwise stated.

47 OTHER INSTRUMENTATION↗

Ultrafine Condensation Particle Counter Instrument Handbook

The Model 3776 Ultrafine Condensation Particle Counter (UCPC; pictured in Appendix A) is designed for researchers interested in airborne particles smaller than 20 nm. With sensitivity to particles down to 2.5 nm in diameter, this UCPC is ideally suited for atmospheric and climate research, particle formation and growth studies, combustion and engine exhaust research, and nanotechnology research.

47 OTHER INSTRUMENTATION↗

Scanning Mobility Particle Sizer (SMPS) Instrument Handbook

The Model 3936 Scanning Mobility Particle Spectrometer (SMPS) measures the size distribution of aerosols ranging from 10 nm up to 1000 nm. The SMPS uses a bipolar aerosol charger to keep particles within a known charge distribution. Charged particles are classified according to their electrical mobility, using a long-column differential mobility analyzer (DMA). Particle concentration is measured with a condensation particle counter (CPC). The SMPS is well-suited for applications including: nanoparticle research, atmospheric aerosol studies, pollution studies, smog chamber evaluations, engine exhaust and combustion studies, materials synthesis, filter efficiency testing, nucleation/condensation studies, and rapidly changing aerosol systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stereo Cameras for Clouds (STEREOCAM) Instrument Handbook

The three pairs of stereo camera setups aim to provide synchronized and stereo calibrated time series of images that can be used for 3D cloud mask reconstruction. Each camera pair is positioned at approximately 120 degrees from the other pair, with a 17o-19o pitch angle from the ground, and at 5-6 km distance from the U.S. Department of Energy (DOE) Central Facility at the Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) observatory to cover the region from northeast, northwest, and southern views. Images from both cameras of the same stereo setup can be paired together to obtain 3D reconstruction by triangulation. 3D reconstructions from the ring of three stereo pairs can be combined together to generate a 3D mask from surrounding views. This handbook delivers all stereo reconstruction parameters of the cameras necessary to make 3D reconstructions from the stereo camera images.

47 OTHER INSTRUMENTATION↗

Tethered Balloon System (TBS) Instrument Handbook

The Tethered Balloon System (TBS) is an unmanned aerial system composed of a helium-filled balloon, tether, winch, and sensors. Individual components of the system may change with each flight based on the desired measurements, atmospheric conditions, and flight strategy. The TBS operates within the U.S. Department of Energy (DOE)’s R-2204 Restricted Airspace, which encompasses a two-nautical-mile radius centered on Oliktok Point, Alaska that is segmented by altitude into R-2204 Low (0-1,499’ MSL or 0-457 m MSL) and R-2204 High (1,500-6,999’ MSL or 457-2133 m MSL). The TBS may operate outside of R-2204 if allowed to do so under a Certificate of Authorization from the Federal Aviation Administration.

42 ENGINEERING↗

Weighing Bucket Rain Gauge Instrument Handbook

The OTT precipitation gauge is used for automatic determination of the intensity and amount of precipitation. In contrast to conventional precipitation gauges, the Pluvio2 works using the balance principle. The gauge reliably recognizes precipitation by determining the weight of the collecting bucket. A high-precision stainless steel load cell, hermetically sealed against environmental influences, is used as the sensor element. An integrated temperature sensor compensates for the temperature changes in the weighing mechanism. These sensors have been found to be stable for years. The orifice of the gauge is heated and when snow/ice precipitation occurs, the weight of its water equivalent is the amount observed.

42 ENGINEERING↗

Detector Instrumentation, Energy Reconstruction and Data Analysis in the DUNE and NOvA Neutrino Experiments

Neutrino oscillations are so far the only experimental observation beyond the standard model since its development four decades ago. The remaining fundamental questions that can be answered by long-baseline neutrino oscillations are (1) the CP violation (whether neutrinos and antineutrinos behave the same way in oscillation), and (2) the mass hierarchy ($m_3>m_{1,2}$ or $m_{1,2}>m_3$), and (3) the octant of $\theta_{23}$ ($\theta_{23}>45^\circ, =45^\circ$ or $<45^\circ$). The PI's group at UCI focuses on long-baseline neutrino experiments DUNE and NOvA, key components of DOE's Intensity Frontier program. NOvA is the current major U.S.-based long-baseline neutrino experiment aiming to solve the mass hierarchy and $\theta_{23}$ octant. It is taking $\nu$ and $\bar{\nu}$ data from the NuMI beam at Fermilab. DUNE is the next-generation flagship neutrino experiment in the U.S. which is designed to decisively determine neutrino CP violation, mass hierarchy and $\theta_{23}$ octant. DUNE is Fermilab's first priority, and has been established as an international collaboration. During the period covered by the report, the PI's group has been exceptionally productive, with leading contributions to DUNE argon-purity monitoring detectors, NOvA/DUNE deep-learning reconstruction, and NOvA oscillation and near detector (ND) analyses. The group also is actively involved in DUNE/NOvA detector operation, data production, calibration, software upgrade and maintenance, and ProtoDUNE cold electronic QA/QC. Specifically, we have made accomplishments in the following four research projects: 1) Purity monitor R\&D and data analysis for DUNE, 2) Deep-learning-based energy reconstruction at NOvA and DUNE, 3) Oscillation analysis at NOvA, and 4) $\nu$-e elastic scattering analysis at NOvA.

47 OTHER INSTRUMENTATION↗

Application-Specific Implementations: Self-Consistent Analysis, Uncertainty Estimation, Instrumentation Effects

When UF 6 is located on the bottom of a cylindrical container lying flat, the Hage-Cifarelli formalism can be used to reconstruct the multiplication of the UF 6 and the strength of the 234 U (a,n) source, from which the 235 U can be inferred. However, when the UF 6 sticks to the ends or to the sides of the container, the reconstruction is no longer predictive in terms of source strength. The same conclusions were reached, whether one uses 3 He tubes or scintillators to detect the neutrons. Feynman’s point theory underlying the reconstruction would need to be improved to address the differences in source strenghts observed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single-Channel Tricolor Absorption Photometer (STAP) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook describes the principles and operations of the single-channel tricolor absorption photometer, Model 9406.

47 OTHER INSTRUMENTATION↗