Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Developing Ultra-small Scale Mechanical Testing Methods and Microstructural Investigation Procedures for Irradiated Materials

Nuclear materials are an essential aspect of nuclear engineering. While great effort is spent on designing more advanced reactors or enhancing a reactor’s safety, materials have been the bottleneck of most new developments. The designs of new reactor concepts are driven by neutronic and thermodynamic aspects, leading to unusual coolants (liquid metal, liquid salt, gases), higher temperatures, and higher radiation doses than conventional light water reactors have. However, any (nuclear) engineering design must consider the materials used in the anticipated application in order to ever be realized. Designs which may look easy, simple and efficient considering thermodynamics or neutronic aspects can show their true difficulty in the materials area, which then prevents them from being deployed. In turn, the materials available are influencing the neutronic and thermodynamic designs and therefore must be considered from the beginning, requiring close collaborations between different aspects of nuclear engineering. If a particular design requires new materials, the licensing of the reactor must be considered, but licensing can be a costly and time consuming process that results in long lead times to realize true materials innovation.

36 MATERIALS SCIENCE↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Active Inspection of Nuclear Materials Using {sup 4}He Scintillation Detectors

The detection of fissionable materials by neutron and high-energy photon active interrogation methods is explored using {sup 4}He scintillation detectors to search for prompt and delayed neutron signature. The low electron density of {sup 4}He in addition to its pulse shape discrimination capability allows strong rejection of gamma radiation. For the detection of the prompt neutron signatures, this capability is important as the signal produced by induced fission is accompanied by intense gamma radiation. The nanosecond time resolution of {sup 4}He scintillation detectors can be used for time-of-flight measurements aimed at determining the energy of the emitted neutrons. For delayed neutron detection, the insensitivity to the low energy neutrons present from non-signal reactions is inherent. Unlike detectors requiring a moderator, this technology can easily be collimated to reduce sensitivity to neutrons from outside the field of interest. The performance of the detectors for these applications is studied using GEANT4 computer modeling, based on measured detector parameters. A comparison is made with technologies typically used for these applications, i.e. heavily shielded organic scintillators for prompt neutron detection and Cd-lined {sup 3}He neutron detectors for the detection of delayed neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Safeguards for the Lithium Fluoride Thorium Reactor: A Preliminary Nuclear Material Control and Accounting Assessment

This report was prepared by Oak Ridge National Laboratory (ORNL) for Flibe Energy Inc. (FEI), a US-based advanced reactor company founded in 2011 and headquartered in Huntsville, Alabama. FEI is developing the lithium-fluoride thorium reactor (LFTR), which is a modern two-fluid molten salt reactor (MSR) design operating on a thorium/ 233 U fuel cycle. FEI intends for LFTR to become a self-sustaining clean energy source that can create or breed its own fuel from thorium. Each LFTR is intended to breed enough fissile material to compensate for the amount it consumes. Consequently it would not require fissile replenishment during its operational lifetime. This self-sustaining nature would eliminate the need for uranium enrichment infrastructure to support LFTRs after the first generation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Non-Contact Measurement of Thermal Diffusivity in Ion-Implanted Nuclear Materials

Knowledge of mechanical and physical property evolution due to irradiation damage is essential for the development of future fission and fusion reactors. Ion-irradiation provides an excellent proxy for studying irradiation damage, allowing high damage doses without sample activation. Limited ion-penetration-depth means that only few-micron-thick damaged layers are produced. Substantial effort has been devoted to probing the mechanical properties of these thin implanted layers. Yet, whilst key to reactor design, their thermal transport properties remain largely unexplored due to a lack of suitable measurement techniques. Here we demonstrate non-contact thermal diffusivity measurements in ion-implanted tungsten for nuclear fusion armour. Alloying with transmutation elements and the interaction of retained gas with implantation-induced defects both lead to dramatic reductions in thermal diffusivity. These changes are well captured by our modelling approaches. Our observations have important implications for the design of future fusion power plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry

This work demonstrates an analytical protocol for high precision Sm isotope analysis by thermal ionization mass spectrometry (TIMS) using a Pt activator. Here, the method permits precise measurements of small aliquots (1–20 ng) of Sm on single Re filament using a modified static-total evaporation technique. This study represents the first attempt to use such protocols for Sm isotope analyses while reducing the loading size of Sm for TIMS. The method could potentially be deployed to study geological, meteorites and lunar samples containing low Sm concentrations, to monitor neutron irradiation exposure based on 149,150 Sm, or to measure Sm isotopic composition in other types of nuclear samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A new capability facilitating nuclear materials research: the Activated Materials Laboratory at the Advanced Photon Source

The Activated Materials Laboratory (AML), located in the Long Beamline Building (LBB) of the Advanced Photon Source (APS) of Argonne National Laboratory (ANL), serves as a centralized radiological facility for preparing radioactive samples for APS beamline experiments. The AML is equipped to receive shipments, handle open-form radioactive materials, encapsulate samples, and transport samples to-and-from beamline end-stations. The AML works closely with users and the APS radiological safety committee to make sure the safe conduct of experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stochastic Approaches for Calculating and Aggregating Detection Probabilities for Nuclear Material Diversion

The goal of this project is to develop statistical methods and tools that can be used to rigorously calculate achieved DPs on individual material strata and then aggregate these to the facility and state levels. In particular, this project is evaluating the utility of stochastic ("Monte Carlo") methods as a potentially more powerful and flexible option to the analytical solutions traditionally employed by IAEA statisticians.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A system for the measurement of delayed neutrons and gammas from special nuclear materials

The delayed neutron counting (DNC) system at the Royal Military College of Canada has been upgraded to accommodate concurrent delayed neutron and gamma measurements. This delayed neutron and gamma counting (DNGC) system uses a SLOWPOKE-2 reactor to irradiate fissile materials before their transfer to a counting arrangement consisting of six ³He and one HPGe detector. The application of this system is demonstrated in an example where delayed neutron and gamma emissions are used in complement to examine ²³³U content and determine fissile mass with an average relative error and accuracy of -2.2 and 1.5 %, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Computational Age Dating of Special Nuclear Materials

This slide-show presented an overview of the Constrained Progressive Reversal (CPR) method for computing decays, age dating, and spoof detecting. The CPR method is: Capable of temporal profiling a SNM sample; Precise (compared with known decay code, such a ORIGEN); Easy (for computer implementation and analysis). We have illustrated with real SNM data using CPR for age dating and spoof detection. If SNM is pure, may use CPR to derive its age. If SNM is mixed, CPR will indicate that it is mixed or spoofed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Detecting fission from special nuclear material sources

A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a graphing component that displays the plot of the neutron distribution from the unknown source over a Poisson distribution and a plot of neutrons due to background or environmental sources. The system further includes a known neutron source placed in proximity to the unknown source to actively interrogate the unknown source in order to accentuate differences in neutron emission from the unknown source from Poisson distributions and/or environmental sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Triple Coincidence for the Detection of Small Amounts of Special Nuclear Materials

We constructed a device that measures two {gamma}-rays and one neutron from spontaneous fission and any resulting multiplication chains. It extends the associated particle technique based upon correlated counting of the multiplicity of gamma-rays and neutrons released in spontaneous- or neutron-induced fission. There are two advantages in incorporating a third detector in the design over the standard two-detector version. First, we found that random uncorrelated events dominate the background of coincident counting with a gamma-ray and neutron detector. These might be suppressed by requiring an additional coincidence. Second, the time history of gamma-ray emission between the two gamma-ray detectors is related to multiplication in the target media. Multiplication in highly enriched uranium is much greater than in depleted uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable nuclear material detector and process

A portable, hand held, multi-sensor radiation detector is disclosed. The detection apparatus has a plurality of spaced sensor locations which are contained within a flexible housing. The detection apparatus, when suspended from an elevation, will readily assume a substantially straight, vertical orientation and may be used to monitor radiation levels from shipping containers. The flexible detection array can also assume a variety of other orientations to facilitate any unique container shapes or to conform to various physical requirements with respect to deployment of the detection array. The output of each sensor within the array is processed by at least one CPU which provides information in a usable form to a user interface. The user interface is used to provide the power requirements and operating instructions to the operational components within the detection array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waste minimization efforts at the H-Canyon nuclear materials processing facility located at the Savannah River Site - 15535

During the last decade, the H-Canyon at the Savannah River Site (SRS) has employed various means to minimize liquid waste generation and/or to segregate liquid waste that favors generation of low level vs high level wastes. The primary drivers were cost reduction and support of SRS liquid waste tank farm feed to the SRS's Defense Waste Processing Facility. Recent High Level Waste (HLW) volume restrictions (transfers of liquid waste from the H-Canyon to the SRS's Liquid Waste System) imposed on H-Canyon have renewed waste minimization efforts. For the next several years, H-Canyon is faced with a HLW transfer reduction of approximately 65% (reduced from approximately 300,000 gallons to 100,000 gallons). This comes at a time when H-Canyon (and a companion facility named HB-Line) are about to begin executing two high profile missions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry↗

Fast-neutron Multiplicity Counter for Passive and Active Measurements of Special Nuclear Material

We developed a fast-neutron multiplicity counter (FNMC) based on organic scintillators (liquid and stilbene). The system is able to detect correlated photon and neutron multiplets emitted by fission reactions. We tested the system both in passive and active operation mode, and present the results of the experiments, both carried out at the Zero Power Physics Reactor of Idaho National Laboratory. The system was operated in coincidence mode (with a gate time of 50 nanoseconds) and two calibration-based approaches were used to estimate the 240Pu effective (240Pueff) and 235U mass of the samples. In passive mode, we assayed two types of plutonium metal plates, i.e. PAHN and PANN, with a 240Pueff mass of 4.7 g and 25.05 g per plate, respectively. The 239Pu mass percentage was 74% for the PAHN and 95% for the PANN series. We measured neutrons emitted in coincidence by several plate assemblies, having an overall 240Pueff mass in the 4.7 g to 500 g range. In active mode, we characterized several uranium samples. We used two AmLi sources (~50000 neutrons emitted per second) to induce fission in the samples. The first six measured samples were certified reference materials (CRM, set 149), having a constant enrichment, i.e. 93.2 wt%, and mass in the range between 0.5 and 4 kg. Additionally, we assayed three CRM-146 samples, with constant total mass of 500 g and an enrichment of 20.1 wt%, 52.8 wt% and 93.2 wt%. In both configurations, the system succeeded in estimating the fissile mass of an unknown sample with a statistical uncertainty lower than 1% (4-minute assay) and 7% (10-minute assay), in passive and active mode, respectively. In passive mode, the statistical uncertainty is lower than the one achieved by standard 3He counters for plutonium metal samples of similar mass. The difference between the estimated and the declared 240Pueff mass, i.e., the bias error, measured by the fast neutron multiplicity counter was consistently lower compared to the bias error of a standard thermal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗