Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Normalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Deep nonparametric estimation of intrinsic data structures by chart autoencoders: Generalization error and robustness

Autoencoders have demonstrated remarkable success in learning low-dimensional latent features of high-dimensional data across various applications. Assuming that data are sampled near a low-dimensional manifold, we employ chart autoencoders, which encode data into low-dimensional latent features on a collection of charts, preserving the topology and geometry of the data manifold. Our paper establishes statistical guarantees on the generalization error of chart autoencoders, and we demonstrate their denoising capabilities by considering n noisy training samples, along with their noise-free counterparts, on a d-dimensional manifold. By training autoencoders, we show that chart autoencoders can effectively denoise the input data with normal noise. We prove that, under proper network architectures, chart autoencoders achieve a squared generalization error in the order of n–$\frac{2}{d+2}$log 4 n, which depends on the intrinsic dimension of the manifold and only weakly depends on the ambient dimension and noise level. We further extend our theory on data with noise containing both normal and tangential components, where chart autoencoders still exhibit a denoising effect for the normal component. As a special case, our theory also applies to classical autoencoders, as long as the data manifold has a global parametrization. Furthermore, our results provide a solid theoretical foundation for the effectiveness of autoencoders, which is further validated through several numerical experiments.

97 MATHEMATICS AND COMPUTING↗

A bi-level data-driven framework for fault-detection and diagnosis of HVAC systems

Long-term operation of heating, ventilation, and air conditioning (HVAC) systems will eventually lead to a range of HVAC system failures, resulting in excessive energy consumption and maintenance costs. Here, to avoid HVAC malfunctioning, fault detection diagnostic (FDD) is utilized as a common practice. Machine learning methods have lately received considerable interest for FDD analysis of HVAC systems due to their high detection accuracy. Meanwhile, HVAC malfunctions are regarded as rare occurrences, hence normal operating data samples are much more accessible than data samples in faulty and malfunctioning conditions. The dominating frequency of normal operation in HVAC datasets has also led to heavily biased classification algorithms within the literature. Moreover, the focus of previous literature has been on increasing the accuracy of the models which leads to a high number of false positives (misleading alarms) in the system. In order to enhance the performance of diagnostic procedures and fill the mentioned gaps, this study proposes a novel data-driven framework. A bi-level machine learning framework is developed for diagnosing faults in air handling units (AHUs) and rooftop units (RTUs) based on principal component analysis (PCA), time series anomaly detection, and random forest (RF). It is shown that PCA can reduce the dataset dimension with one principal component accounting for 95% of data variance. Also, the random forest could classify the faults with 89% precision for single-zone AHU, 85% precision for RTU, and 79% for multi-zone AHU. By proposing this framework, three persistent challenges are addressed: (I) minimizing false positives; (II) accounting for data imbalance; and (III) normal condition monitoring of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field validation of isotropic analytical models for simulating fabric shades

Fabric roller shades are common shading materials used in commercial and residential buildings. Accurately characterizing and modeling shades helps practitioners select the appropriate product and its control strategy based on climate and occupants' priorities, such as visual comfort and view to outdoors. Previous studies established a generalized method for modeling complex fenestration systems using data-driven tabulated bidirectional scattering distribution functions. However, deploying such a method at scale to all fabric shading products on the market is too costly and time-consuming. Analytical models that are based on a limited set of measurements (e.g., normal-normal and normal-hemispherical visible transmittance and reflectance, and directional cut-off angles) can be used to model the wide variety of shading products on the market. This study evaluates the performance of two isotropic analytical models, Roos-Wienold and Modified-Kotey, for modeling fabric roller shades, with a focus on the model's ability to predict occupant visual comfort. The performance evaluation was conducted through laboratory and field measurements and simulations. The results showed that both models are sufficient for predicting vertical illuminance at seated eye-level. Roos-Wienold model was able to predict binary visual comfort classification (glare/no-glare) under a wide range of luminance conditions, while Modified-Kotey model did not perform as well under high-contrast low-adaptation conditions. Both models are insufficient in predicting visual comfort at a four-point scale (e.g., imperceptible, perceptible, disturbing, intolerable). The two isotropic models become less accurate when the fabric exhibits high anisotropy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A cohesive zone treatment for the material point method involving problems of large deformation and damage

A new algorithm is described that permits the use of cohesive zones in the material point method for problems involving large deformation and fracture. In contrast to previous cohesive zone implementations, this method does not utilize massless surface-element particles. Instead, cohesive tractions are computed using the shape function mappings from a reference grid configuration in combination with explicitly defined particle surface normals and surface positions. These normals and relative surface positions are updated each time step according to particle deformation. The tractions are converted to cohesive forces using the nodal areas and mapped back to particles using the same reference shape function mappings. These forces are then remapped by conventional particle-to-grid interpolation as external forces using the current-configuration shape-function mappings. This allows highly compliant cohesive zones to function over jump displacements larger than a grid cell. Upon damage, these interfaces can revert to conventional multi-field contact surfaces. This approach is general and readily applies to two and three dimensions as well as being compatible with damage-field gradient partitioning offering exceptional computational flexibility. The framework for this method enables other capabilities, such as improved contact precision using explicitly defined surface normals and positions, and a method to mitigate spurious material damage at weak discontinuities between stiff brittle materials and soft or compliant materials.

Cohesive zone↗

Experimental investigation on thermal inertia characterization of commercial buildings for demand response

Characterizing the thermal inertia of commercial buildings is of great importance in quantifying demand flexibility. Experimental tests can be used to investigate the thermal inertia of commercial buildings. However, existing studies tend to be qualitative and have limited scope. In this study, a comprehensive field test has been performed to assess the thermal inertia of commercial buildings. In this field test, six buildings are selected with different sizes, vintages, and types of heating, ventilation, and air conditioning (HVAC) systems to represent the majority of the U.S. commercial building stock. We quantify the thermal inertia with building operation data collected under various thermostat excitation signals. We then studied the relationship between thermal inertia and intrinsic properties, such as floor area, HVAC system, etc., as well as the operation condition indicators such as outdoor air temperature, zone temperature, and occupancy. The testing results indicate that the median values of the normalized charge response time and the normalized discharge response time of the five buildings are 1~5 hr/ °C and -5~-1 hr/ °C, respectively. The results also show that the thermal inertia of commercial buildings may be sensitive to the HVAC system type but not the floor area or location of zones, i.e., core vs. perimeter. Finally, our results suggest that the relationships between the charging/discharging normalized response time and the zone/outdoor temperature may vary among zones and be highly nonlinear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observation of two different cool flame regimes of diethyl ether in a counterflow burner

This short communication reports, for the first time, the existence of two different self-sustaining cool flame regimes of diethyl ether (DEE) in a diffusion counterflow burner: a weaker autoignition-assisted cool flame near the fuel burner and a normal diffusion cool flame near the stagnation plane. Here, the results show that the normal diffusion cool flame extinction limit increases monotonically with the fuel mole fraction, while the autoignition-assisted cool flame approaches a plateau and can exist at a fuel mole fraction below the normal diffusion cool flame. It is shown that both flame regimes are governed by the same low-temperature chain-branching reaction pathway of DEE. By using in situ laser diagnostics, entrainment of unburned fuel stream to oxygen stream at the outer edge of the fuel burner is identified as the governing physical mechanism causing a partially premixed self-sustained hollow cool flame structure. The results reveal that when a fuel with high low-temperature reactivity, two different cool flame regimes can be observed in a counterflow flame experiment. Future studies with high-reactivity fuels in a counterflow burner must ensure to distinguish between the two self-sustaining cool flame regimes. Moreover, the existence of these different cool flame regimes needs to be examined so that they would not trigger an uncontrolled combustion phasing in advanced engines fed with high low-temperature reactivity fuels.

33 ADVANCED PROPULSION SYSTEMS↗

Experimental study of fracture slip due to stress perturbation in fractured geo-resources

Anthropogenic activities such as underground fluid injection/extraction, well stimulation, and dam impoundment will perturb the state-of-stress in the subsurface, which could activate critically stressed pre-existing fractures and faults. Fault and fracture activation can induce seismicity, change flow behavior, and damage asperities on the fracture surface to alter reservoir permeability. Here, in this study, triaxial shear tests were conducted on saw cut and rough fracture Barre granite specimens to better characterize how a decrease in normal stress and increase in shear stress will influence crystalline rock fracture hydromechanical properties. In a triaxial set up, confining pressure (CP) and differential stress (DS) were used to induce normal and shear stress on a 45° oriented fracture. Fracture slip and the corresponding stress relaxation was observed when the confining stress decreased. Fracture permeability increased when the fracture slipped. Moreover, new micro-cracks observed by x-ray images indicated the creation of new flow paths for fluid movement. The experimental outcomes of this study indicate that decrease in normal stress due to stress perturbations along the faults/fractures in the extensional stress regime can induce the slip along the fracture. This could have a significant influence on slope stability in quarries, stimulation and injection strategy in deep geo-resources, and potentially minimize the risk of induced seismicity. The observed stress dependency of hydraulic aperture in rough fracture during pre- and post-slip stages could provide key inputs for field-scale simulation of geo-resources.

58 GEOSCIENCES↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Rates of levoglucosanol hydrogenolysis over Brønsted and Lewis acid sites on platinum silica-alumina catalysts synthesized by atomic layer deposition

Nanoscale coatings of AlO x were deposited onto SiO 2 using atomic layer deposition (ALD) to synthesize amorphous silica-alumina (SiAl) catalysts, and these catalysts were investigated for levoglucosanol (Lgol) hydrogenolysis. With decreasing Al 2 O 3 loading, the ratio of Brønsted to Lewis acid sites, measured by NH 3 -TPD and pyridine-FTIR, systematically increases, while the Al coordination, measured by solid state 27 Al NMR, decreases. These structural changes correspond to an increasing mass-normalized rate of Lgol hydrogenolysis. We model the mass-normalized reaction rate as the sum of independent contributions from Brønsted and Lewis sites, showing that Brønsted acid sites on ALD-AlO x /SiO 2 catalysts have a 6-times higher turnover frequency (TOF) than Lewis acid sites on these catalysts. Additionally, Lewis acid sites on ALD-AlO x /SiO 2 catalysts (potentially related to Al(V) species) have a 4-times higher TOF than Lewis acid sites on bulk γ-Al 2 O 3 . The overall mass-normalized reactivity of ALD-AlO x /SiO 2 catalysts is due to Lewis acid sites at the highest Al 2 O 3 loading, while it is predominantly due to Brønsted acid sites at the lowest Al 2 O 3 loadings. In conclusion, this work provides a new approach to synthesize amorphous SiAls with tunable Brønsted/Lewis acid site ratio and reveals differences in the reactivity of Brønsted and Lewis acid sites on these materials.

36 MATERIALS SCIENCE↗

An arbitrarily high-order three-dimensional Cartesian-grid method for reconstructing interfaces from volume fraction fields

Here Tthis work describes a newly developed, arbitrarily high-order Cartesian-grid method for reconstructing material interfaces from a volume fraction field. The method begins by identifying all of the grid cells in the volume fraction field that are intersected by the interface and need to be approximated by the reconstruction scheme. Finite-differences are used to calculate the gradient of the volume fraction field and provide an estimate of the surface normal in all of the interfacial grid cells. Groups of connected grid cells are then identified which all have the same dominant component of the normal vector. This grouping by orientation determines the proper dependent variable to use in the surface reconstruction (e.g. for a 2D curve, this step determines if the surface will be approximated by a function of x or y). A cumulative integral over the surface is constructed and fit using b-splines for two-dimensional problems or tensor-product b-splines for three-dimensional problems. This construction allows for the interface to be recovered through application of the second fundamental theorem of calculus. Fitting the cumulative integral with $\mathscr{N}$ th-order b-splines (or tensor-product b-splines) yields an ($\mathscr{N}$-1) th-order convergence rate of the interface shape. Differentiation of the b-spline interface function(s) allows for the high-order approximation of the normal vector and curvature to be obtained directly anywhere along b-spline. Together, the proposed reconstruction technique can achieve arbitrarily high mesh convergence rates. Validation tests are presented with mesh convergence rates ranging from fourth- to tenth-order.

97 MATHEMATICS AND COMPUTING↗

Microstructural analysis of tristructural isotropic particles in high-temperature steam mixed gas atmospheres

High-temperature gas-cooled reactors (HTGRs) use tristructural isotropic (TRISO) particles embedded in a graphitic matrix material to form the integral fuel element. Potential off-normal reactor conditions for HTGRs include steam ingress with temperatures above 1,000 °C. Fuel element exposure to steam can cause the graphitic matrix material to evolve, forming an atmosphere composed of oxidants and oxidation products and potentially exposing the TRISO particles to these conditions. Investigating the oxidation response of TRISO particles exposed to a mixed gas atmosphere will provide insight into the stability under off-normal conditions. In this study, surrogate TRISO particles were exposed to high temperatures (T = 1,200 °C) in flowing steam (3% < pH 2 O < 21%) and CO (pCO < 1%) to determine the oxidation behavior of the SiC layer when exposed to various mixed gas atmospheres. Scanning electron microscopy, x-ray diffraction, and focused ion beam milling was used to determine the impact of CO and steam on the oxidation behavior of the SiC layer. Therefore, the data presented demonstrates how the SiC layer showed strong oxidation resistance due to limited SiO 2 growth and maintained its structural integrity under these off-normal conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of isotropic and anisotropic porous microstructure on electrochemical performance of Li ion battery cathodes: An experimental and computational study

Liquid electrolyte mass transport is a major limitation affecting high-power Li ion batteries. Fast discharging causes Li salt depletion in the current collector region of the cathode which produces overpotential in the electrolyte and consequently a drop of cell voltage to below the cut-off voltage, especially at higher electrode thickness and discharge rate. In this study, through experiment and simulation, we have investigated the effect of electrode thickness, mass loading, discharge rate and tortuosity on electrolyte mass transport and final derived areal capacity and specific energy for electrodes having isotropic (normal tape casting) and anisotropic (freeze tape casting) porous microstructure. Furthermore, the macroporous channels in freeze tape cast electrodes facilitate Li salt transport and reduce the Li salt mass transport limitations even at high electrode thickness and discharge rates, and high electrode tortuosity. In our results, computer simulations show that freeze tape cast electrodes may be fully discharged up to 750 μm thickness at 1 C rate compared to 300 μm for normal tape cast electrodes with the same mass loading. Freeze tape cast electrodes also show stable maximum areal capacity for C rates about double the maximum C rates of their normal tape cast electrode counterparts with the same mass loading.

25 ENERGY STORAGE↗

Statistical characterization of twin transmission across grain boundaries in magnesium

Here, a detailed statistical analysis of twin transmission (TT) across grain boundaries is performed in rolled, commercial purity magnesium compressed along the rolling direction. EBSD images are acquired from two different cuts: a section containing the rolling (RD) and normal (ND) directions; and a section at 35° to the ND which contains transverse direction (TD). An automated twinning analysis software, METIS, is used to obtain the statistical correlations between deformation twins and other microstructural features by analyzing EBSD microstructures comprising thousands of grains and twins. This detailed statistical analysis reveals that the TT propensity is sensitive to the grain boundary (GB) misorientation angle but not to the GB misorientation axis. Specifically, TT propensity decreases with increasing GB misorientation angle; however, the decreasing trend is not monotonic. Further, the detailed analysis of TT events combining macroscopic Schmid factor and the geometric measures (m’: accounts for the alignment of both twin plane normal and shear directions; m”: accounts for the alignment of only twin shear directions; and m”’: accounts for the alignment of only twin plane normal) helps in understanding and identifying the process of twin-pair formation, i.e., co-nucleation versus transmission, also to identify the role of local stresses at GBs induced by inter-grain interaction versus twinning shear transformation processes. In addition, Bayesian inference is used to draw statistically meaningful conclusions as to the likelihood of transmission given misorientation angles. Lastly, twin chain frequency as a function of chain length is predicted using the probability distribution obtained from the Bayesian inference and compared with the actual data from the EBSD microstructures.

36 MATERIALS SCIENCE↗

Complete coverage fouling model for constant flux crossflow ultrafiltration and experimental validation

A complete coverage model is proposed to describe fouling in constant flux crossflow ultrafiltration. Constant flux crossflow fouling experiments were conducted using dilute latex bead suspensions and commercial poly(ether sulfone) flat sheet ultrafiltration membranes to investigate the influence of operating conditions on evolution of transmembrane pressure (ΔP, TMP) with time. Changes in permeate flux or crossflow rate had little influence on the normalized TMP profile at high latex bead concentration (i.e., above 25 ppm) because the membrane surface was covered with latex beads. At low concentration (i.e., below 25 ppm), increases in permeate flux or foulant concentration increased normalized ΔP. However, this increase in normalized ΔP with permeate flux or foulant concentration diminishes when the permeate flux/concentration is high enough to overwhelm particle removal due to crossflow. Furthermore, these results are in good agreement with the new complete coverage model which describes the influence of operating parameters on fouling better than the previous model.

36 MATERIALS SCIENCE↗

Deformation behavior of nanoscale Al–Al 2 Cu eutectics studied by in situ micropillar compression

We report deformation behavior of nanoscale laser processed Al–Al 2 Cu eutectics at room temperature is characterized through in situ micro-pillar compression testing in a scanning transmission microscope. Interlamellar spacing of Al–Al 2 Cu eutectics varies from hundreds of nanometers to 20 nm. Three different sizes of micro-pillars are fabricated in order to study the deformation behaviors of single colony and multiple colonies, corresponding to the single crystal and polycrystal respectively. For single colonies, lamellar orientations parallel, normal or inclined to the loading direction were tested. The main findings are: 1) the plasticity mechanisms strongly depend on loading orientation: buckling and kinking in the parallel-loaded eutectics, planar sliding along Al–Al 2 Cu lamellar interfaces in the incline-loaded eutectics and localized shearing in the normal-loaded eutectics. 2) the incline-loaded eutectics exhibits the lowest compression flow strength, and the normal-loaded eutectics has the highest compression flow strength. 3) with decreasing inter-lamellar spacing, the strength increases and plasticity is uniformly distributed, as opposed to shear localization. Highest compressive plasticity is observed in polycrystalline eutectics with an ensemble of lamellar orientations with ~20 nm average spacing: 17.9% at flow stress of 1.63 GPa, and degenerate, bimodal morphology: 11.1% at flow stress of 1.36 GPa.

36 MATERIALS SCIENCE↗

Development of techniques for gantryless associated-particle imaging

To move fast-neutron radiography using the associated-particle imaging technique from the laboratory to the field, the development of new analysis techniques is required. In particular, the relative positions of the source and detectors need to be determined when they have been placed by hand, the normalization for a particular source–detector geometry needs to be determined without a measurement in the same geometry with no object present, and accurate image stitching is required when multiple detector positions are necessary to image an object. The present work describes methods that employ transmission neutron data to localize a fast-neutron imaging panel with respect to the neutron source, calculate a normalization for a given source–detector geometry, stitch images together, and describes the required system calibrations. The reported techniques enable in-field neutron radiography for cases in which the source–detector geometry is not well known a priori and where operational constraints preclude a normalization measurement.

Heath, Matthew↗

Density scaling approximation for Monte-Carlo simulations of radioactive plumes

The release of radioactive gas into the atmosphere can diffuse into large volumes of air downwind from the point of release. The extent of radioactivity can cover thousands of cubic meters of air. For such large volumes, the weather models used to predict the down-wind distribution of the plume and the radiation transport models used to predict the radiation reaching ground-level from the plume can take tens of hours of computer time on multi-node institutional High-Performance Computing facilities. In this paper we focus on the radiation transport aspect of plume modeling. Here, we describe a phenomenological method for approximating the amounts of radiation that reach ground level from large volumes of a static radioactive plume that can be calculated on a stand-alone personal computer in much shorter computation times than those usually needed for such large volume evaluations. We refer to this method as the Density Scaling Approximation (DSA). Its ability to approximate ground-level count rates of large plumes comes from using a small-plume volume with a scaled-up value of air density to simulate the same number of scatterings that occur during transport in larger plume volumes at normal air density. We demonstrate the DSA by using a 100 m-diameter air-filled hemispherical dome geometry with a uniform volumetric activity of 135 Xe gas throughout the air-filled volume. The DSA for a larger dome diameter is obtained by evaluating the 100 m dome with an air density scaled up by the linear ratio of the larger diameter to the 100 m diameter. We find that this approximation works well for dome diameters up to 1200 m – the largest diameter studied and a size more than sufficient for accounting for all the radiation from 135 Xe. Moreover, most of our DSA results can be calculated over 500 times faster than corresponding full-sized geometry with normal air density. To help evaluate the accuracy of the DSA and gain insight into how well it can reproduce different regions of the spectra, we use three, easily understood regions of interest to compare the DSA results to the full-sized geometry at normal air density results. These regions are the full-energy peak, the region of single-Compton scattering, and the region of multiple-Compton scattering. We show how the dominance of the Compton scattering mechanism determines this division and thus provides insight into how Compton scattering is manifested in spectra from photon scattering through air in general, and how well the DSA approximation works.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing high fidelity multi-component models to facilitate safeguards at Gas Centrifuge Enrichment Plants

We report that the International Atomic Energy Agency (IAEA) inspectors routinely carry out environmental sampling (ES) as a verification method. Collection of environmental swipe samples at various locations in Gas Centrifuge Enrichment Facilities (GCEPs) is an important process in detecting misuse of a declared facility and possibly the existence of undeclared nuclear material. These samples are measured for isotopic composition in uranium containing particles by Thermal Ionization Mass Spectrometry (TIMS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Even though ES is highly effective in detecting the absolute value of enrichments and their deviations from the declared values, it cannot explain the cause of those changes. Several potential explanations can serve as possibilities for particles detected above or other than the declared enrichment. These include normal and non-malicious events such as the design of the enrichment cascades, unintentional failures of the machines, or overshoot during startup of a cascade. It can also be the result of deliberate misuse by the facility operators. The primary objective of this work is to understand how these factors affect the enrichments produced by a cascade and quantify anticipated multi-isotopic concentrations for each case. The following methodology is employed to determine signatures at a particular facility. 1) Utilize a new two-dimensional multi-component diffusion code to obtain centrifuge performance data and use that information to design and perform cascade analysis. Compare and contrast the results with previous 1-D radially averaged solutions from the Pancake code. 2) Design a GCEP cascade with the production goal of 19.75% 235 U for each set of machine data above. Investigate two cascade scenarios that include enrichment of natural uranium (NU) feed to 19.75% 235U in a single cascade compared to a two-step process of NU to 5% and then 5% to 19.75%. 3) Simulate the intentional vs. unintentional off-normal scenarios in the cascades to assess the differences in isotopic concentrations. A non-ideal squared-off cascade model developed at the University of Virginia is used to calculate flow rates and isotopic concentrations of the process gas. The analysis is performed using the Rome machine model operated at 600 m/s rotor speed. The upper and lower bounds of normal and abnormal enrichments in a typical facility are used in conjunction with ES results to understand the root causes of such observations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗