Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Faster Antenna Noise Temperature Calculations Using a Novel Approximation Technique

In order to properly tradeoff the various antenna and feed configurations for the Square Kilometre Array (SKA) optical design it is necessary to evaluate the gain and noise temperature of each configuration over a wide range of frequencies. German Cortes describes the standard technique for computing antenna noise temperature. However, since the total antenna pattern needs to be calculated over the entire 4 pi steradians at a fine enough resolution to accurately include the main beam, the computer time required is enormous. Even at modest frequencies and reflector sizes (approximately 5 to 10 GHz for a 12 meter main reflector) the technique can take days on a single node of a supercomputer. Utilizing the standard technique to compute the noise temperature for all the cases required to properly characterize the SKA design is clearly not feasible. At least a 100 to 1000 speedup in the computation time is required. This paper describes an approximation technique that can accomplish this improvement with extremely small errors in noise temperature calculation of a few tenths of Kelvin.

Reflector Antennas↗

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy↗

Reducing the Effect of Transducer Mount Induced Noise on Aeroacoustic Wind Tunnel Testing Data with a New Transducer Mount Design

Characterization of launch vehicle unsteady aerodynamics is a field best studied through experimentation, which is often carried out in the form of large scale wind tunnel testing. Measurement of the fluctuating pressures induced by the boundary layer noise is customarily made with miniature pressure transducers installed into a model of the vehicle of interest. Literature shows that noise level increases between two to five decibels (dB referenced to 20 micropascal) can be induced when the transducer surface is not mounted perfectly flush with the model outer surface. To reduce this artificially induced noise, special transducer holders have been used for aeroacoustic wind tunnel testing by NASA. This holder is a sleeve into which the transducer fits, with a cap that allows it to be mounted in a recessed hole in the model. A single hole in the holder allows the transport of the tunnel medium so the transducer can discriminate the fluctuating pressure due to the turbulent boundary layer noise. The holder is first dry fitted into the model and any difference in height between the holder and the model surface can be sanded flush. The holder is then removed from the model, the transducer glued inside the holder, and the holder replaced in the model, secured also with glue, thus eliminating the problem of noise level increases due to lack of flushness. In order to work with this holder design, special transducers have been ordered with their standard screen removed and the diaphragm moved as close to the top of the casing as possible to minimize any cavity volume. Although this greatly reduces induced noise due to the transducers being out of flush, the holders can also induce a cavity resonance that is usually at a very high frequency. This noise is termed transducer mount induced noise (XMIN). The peak of the mode can vary with the cavity depth, boundary layer noise that can excite the mode, tunnel flow medium, and the build of the transducers. Because the boundary layer flow interaction with the microphone holder seems to have some effect on the cavity resonance response, the NASA/Marshall Space Flight Center (MSFC) aeroacoustic team postulated that changing the design of the holder might reduce the cavity resonance response. An experiment was performed at the MSFC Trisonic Wind Tunnel comparing a new holder design with the traditional MSFC holder. The new holder design is intended to mimic the Kulite Semiconductors, Inc. B-screen, where the single hole of the traditional MSFC holder is replaced by a series of ten 0.007 inch diameter holes. This particular design serves to protect the transducer diaphragm as in the manufacturer's B-screen, but also increases the frequency of the XMIN such that it is not apparent in the data collected from aeroacoustic wind tunnel tests. MSFC compared the two holder designs by installing two transducers in standard holders on one side of a ten inch long ten degree cone, and two transducers in B-screen holders on the opposite side for a series of runs at different conditions. Over 11-13 February, 2013, the model was run at Mach numbers between 0.80 and 1.96 at angles of attack at 0 deg, plus or minus 1 deg, plus or minus 2 deg, plus or minus 4 deg, and plus or minus 8 deg. Model roll attitudes at 0 deg, 90 deg, and 180 deg were tested to isolate potential tunnel bias. This paper presents results from the test showing that the proposed holder design significantly reduces the influence of XMIN on measured fluctuating pressure levels.

Herron, A. J.↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Automated measurement of the bit-error rate as a function of signal-to-noise ratio for microwave communications systems

The performance of microwave systems and components for digital data transmission can be characterized by a plot of the bit-error rate as a function of the signal to noise ratio (or E sub b/E sub o). Methods for the efficient automated measurement of bit-error rates and signal-to-noise ratios, developed at NASA Lewis Research Center, are described. Noise measurement considerations and time requirements for measurement accuracy, as well as computer control and data processing methods, are discussed.

Kerczewski, Robert J.↗

Performance of a Y-Ba-Cu-O superconducting filter/GaAs low noise amplifier hybrid circuit

A superconducting 7.3 GHz two-pole microstrip bandpass filter and a GaAs low noise amplifier (LNA) were combined into an active circuit and characterized at liquid nitrogen temperatures. This superconducting/semiconducting circuit's performance was compared to a gold filter/GaAs LNA hybrid circuit. The superconducting filter/GaAs LNA hybrid circuit showed higher gain and lower noise figure than its gold counterpart.

Bhasin, K. B.↗

Performance of a Y-Ba-Cu-O superconducting filter/GaAs low noise amplifier hybrid circuit

A superconducting 7.3 GHz two-pole microstrip bandpass filter and a GaAs low noise amplifier (LNA) were combined into a hybrid circuit and characterized at liquid nitrogen temperatures. This superconducting/seismology circuit's performance was compared to a gold filter/GaAs LNA hybrid circuit. The superconducting filter/GaAs LNA hybrid circuit showed higher gain and lower noise figure than its gold counterpart.

Bhasin, Kul B.↗

Shuttling Majorana zero modes in disordered and noisy topological superconductors

The braiding of Majorana zero modes (MZMs) forms the fundamental building block for topological quantum computation. Braiding protocols which involve the physical exchange of MZMs are typically envisioned on a network of topological superconducting wires. An important component of these protocols is the transport of MZMs, which can be performed by using electric gates to locally tune sections of the wire between topologically trivial and nontrivial phases. In this work, we numerically simulate this transport by tuning a single section of a superconducting wire which contains either disorder (uncorrelated and correlated) or noise. We focus on the impact of these additional effects on the diabatic error, which describes unwanted transitions between the ground state and excited states. We show that the behavior of the average diabatic error is predominantly controlled by the statistics of the minimum bulk energy gap which is suppressed in the presence of disorder. The increase in diabatic error can be several orders of magnitude and is most deleterious when the disorder correlation length is a finite fraction of the transport distance and negligible when these lengths are far apart. In the presence of noise, the diabatic error is significantly enhanced due to optical transitions which depend on the minimum bulk energy gap as well as the frequency modes present in the noise. The results presented here serve to further characterize the diabatic error in disordered and noisy settings, which are important considerations in practical implementations of physical braiding schemes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reliability Analysis in the Presence of Aleatory Uncertainty

This paper proposes a method for modeling a system’s response using data. In contrast to approaches that identify a limit state function, we focus on the case in which not all uncertain parameters affecting the response are observable and the measured response is corrupted by noise. To this end, the system response is not characterized by a limit state function but instead by a Random Predictor Model (RPM) having a nonparametric structure. Consequently, the resulting failure probability is not a scalar but a random variable. This variable accounts for the aleatory contributions of the model-form uncertainty and the measurement noise into the response. Furthermore, we propose a framework that enables trading off the predicted range of failure probabilities resulting from such an analysis with a measure of risk. In this context, risk is the percentage of all predicted outcomes the analyst is willing to ignore. The reliability analysis of an aeroelastic structure subject to flutter is used to illustrate the ideas proposed.

Crespo, L. G.↗

Bayesian Poroelastic Aquifer Characterization From InSAR Surface Deformation Data. Part I: Maximum A Posteriori Estimate

Characterizing the properties of groundwater aquifers is essential for predicting aquifer response and managing groundwater resources. In this work, we develop a high-dimensional scalable Bayesian inversion framework governed by a three-dimensional quasi-static linear poroelastic model to characterize lateral permeability variations in groundwater aquifers. In this work, we determine the maximum a posteriori (MAP) point of the posterior permeability distribution from centimeter-level surface deformation measurements obtained from Interferometric Synthetic Aperture Radar (InSAR). The scalability of our method to high parameter dimension is achieved through the use of adjoint-based derivatives, inexact Newton methods to determine the MAP point, and a Mat´ern class sparse prior precision operator. Together, these guarantee that the MAP point is found at a cost, measured in number of forward/adjoint poroelasticity solves, that is independent of the parameter dimension. We apply our methodology to a test case for a municipal well in Mesquite, Nevada, in which InSAR and GPS surface deformation data are available. We solve problems with up to 320,824 state variable degrees of freedom (DOFs) and 16,896 parameter DOFs. A consistent treatment of noise level is employed so that the aquifer characterization result does not depend on the pixel spacing of surface deformation data. Our results show that the use of InSAR data significantly improves characterization of lateral aquifer heterogeneity, and the InSAR-based aquifer characterization recovers complex lateral displacement trends observed by independent daily GPS measurements.

54 ENVIRONMENTAL SCIENCES↗

A dual high-energy radiography platform with 15 μ m resolution at the National Ignition Facility

To study matter at extreme densities and pressures, we need mega laser facilities such as the National Ignition Facility as well as creative methods to make observations during timescales of a billionth of a second. To facilitate this, we developed a platform and diagnostic to characterize a new point-projection radiography configuration using two micro-wires irradiated by a short pulse laser system that provides a large field of view with up to 3.6 ns separation between images. In this work, we used tungsten-carbide solid spheres as reference objects and inferred characteristics of the back-lighter source using a forward-fitting algorithm. The resolution of the system is inferred to be 15 μm (using 12.5 μm diameter wires). The bremsstrahlung temperature of the source is 70–300 keV, depending on laser energy and coupling efficiency. By adding the images recorded on multiple stacked image plates, the signal-to-noise of the system is nearly doubled. The imaging characterization technique described here can be adapted to most point-projection platforms where the resolution, spectral contrast, and signal-to-noise are important.

47 OTHER INSTRUMENTATION↗

Calibrated Noise Measurements with Induced Receiver Gain Fluctuations

The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory in science and engineering. These limitations were encountered when modeling the performance of radiometer calibration architectures and algorithms in the presence of non stationary receiver fluctuations. Analyses of measured signals have traditionally been limited to a single measurement series. Whereas in a radiometer that samples a set of noise references, the data collection can be treated as an ensemble set of measurements of the receiver state. Noise Assisted Data Analysis is a growing field of study with significant potential for aiding the understanding and modeling of non stationary processes. Typically, NADA entails adding noise to a signal to produce an ensemble set on which statistical analysis is performed. Alternatively as in radiometric measurements, mixing a signal with calibrated noise provides, through the calibration process, the means to detect deviations from the stationary assumption and thereby a measurement tool to characterize the signal's non stationary properties. Data sets comprised of calibrated noise measurements have been limited to those collected with naturally occurring fluctuations in the radiometer receiver. To examine the application of NADA using calibrated noise, a Receiver Gain Modulation Circuit (RGMC) was designed and built to modulate the gain of a radiometer receiver using an external signal. In 2010, an RGMC was installed and operated at the National Institute of Standards and Techniques (NIST) using their Noise Figure Radiometer (NFRad) and national standard noise references. The data collected is the first known set of calibrated noise measurements from a receiver with an externally modulated gain. As an initial step, sinusoidal and step-function signals were used to modulate the receiver gain, to evaluate the circuit characteristics and to study the performance of a variety of calibration algorithms. The receiver noise temperature and time-bandwidth product of the NFRad are calculated from the data. Statistical analysis using temporal-dependent calibration algorithms reveals that the natural occurring fluctuations in the receiver are stationary over long intervals (100s of seconds); however the receiver exhibits local non stationarity over the interval over which one set of reference measurements are collected. A variety of calibration algorithms have been applied to the data to assess algorithms' performance with the gain fluctuation signals. This presentation will describe the RGMC, experiment design and a comparative analysis of calibration algorithms.

Racette, Paul↗

Improved Flaw Detection and Characterization with Difference Thermography

Flaw detection and characterization with thermographic techniques in graphite polymer composites is often limited by localized variations in the thermographic response. Variations in properties such as acceptable porosity, variations in fiber volume content and surface polymer thickness result in variations in the thermal response that in general cause significant variations in the initial thermal response. These variations result in a noise floor that increases the difficulty of detecting and characterizing deeper flaws. The paper investigates comparing thermographic responses taken before and after a change in state in a composite to improve the detection of subsurface flaws. A method is presented for registration of the responses before finding the difference. A significant improvement in the detectability is achieved by comparing the differences in response. Examples of changes in state due to application of a load and impact are presented.

Winfree, William P.↗

Utilizing distributed acoustic sensing and ocean bottom fiber optic cables for submarine structural characterization

The sparsity of permanent seismic instrumentation in marine environments often limits the availability of subsea information on geohazards, including active fault systems, in both time and space. One sensing resource that provides observational access to the seafloor environment are existing networks of ocean bottom fiber optic cables; these cables, coupled to modern distributed acoustic sensing (DAS) systems, can provide dense arrays of broadband seismic observations capable of recording both seismic events and the ambient noise wavefield. Here, we report a marine DAS application which demonstrates the strength and limitation of this new technique on submarine structural characterization. Based on ambient noise DAS records on a 20 km section of a fiber optic cable offshore of Moss Landing, CA, in Monterey Bay, we extract Scholte waves from DAS ambient noise records using interferometry techniques and invert the resulting multimodal dispersion curves to recover a high resolution 2D shear-wave velocity image of the near seafloor sediments. We show for the first time that the migration of coherently scattered Scholte waves observed on DAS records can provide an approach for resolving sharp lateral contrasts in subsurface properties, particularly shallow faults and depositional features near the seafloor. Our results provide improved constraints on shallow submarine features in Monterey Bay, including fault zones and paleo-channel deposits, thus highlighting one of many possible geophysical uses of the marine cable network.

47 OTHER INSTRUMENTATION↗

Noise in state of the art clocks and their impact for fundamental physics

In this paper a review of the use of advanced atomic clocks in testing the fundamental physical laws will be presented. Noise sources of clocks will be discussed, together with an outline their characterization based on current models. The paper will conclude with a discussion of recent attempts to reduce the fundamental, as well as technical noise in atomic clocks.

noise state-of-the-art clocks fundamental physics↗

Design, construction, and test of the Gas Pixel Detectors for the IXPE mission

Due to be launched in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2–8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis—particularly as far as the response to unpolarized radiation and the stability in time are concerned.

79 ASTRONOMY AND ASTROPHYSICS↗

Highly silanized cellulose biocomposites for sustainable insulation materials

Microfibrillated lignocellulose networks, derived from agricultural byproducts, represent an environmentally friendly biogenic material production due to their abundant availability to circular bioeconomy and inherent carbon sink in life cycle analysis. Yet, its vulnerability to moisture and flammability, coupled with challenges in creating highly reinforced insulation materials, poses challenges for the carbon-zero green building sector. Here we address these challenges with a new concept of in-situ grafting polymerization of nanoporous silica in pre-formed lignocellulosic fiber networks. The seamlessly integrating nanoporous silica with cellulose through hydrogen bonding networks enabled us to prepare highly reinforced biogenic composites for green building insulations. A high reinforcement biocomposite with hierarchal arrangements of nanoporous silica within the cellulose network exhibits remarkable attributes. It boasts a thermal conductivity of 24.2 mW·m –1 ·K –1 , a flexural modulus of 942 MPa, and soundproofing with a 20.8 % noise reduction, as well as the fire resistance characterized by an extended time to ignition and a reduced peak heat release rate of 144 kW·m –2 at 35 kW·m –2 of incident radiant heat flux. Furthermore, it demonstrates a reduced water absorption capacity, dropping from 5.12 g·g –1 to 0.75 g·g –1 . Altogether, this study opens the new pathways towards sustainable carbon-zero building materials in the context of circular bioeconomy.

36 MATERIALS SCIENCE↗

hIPPYlib-MUQ: A Bayesian Inference Software Framework for Integration of Data with Complex Predictive Models under Uncertainty

Bayesian inference provides a systematic framework for integration of data with mathematical models to quantify the uncertainty in the solution of the inverse problem. However, the solution of Bayesian inverse problems governed by complex forward models described by partial differential equations (PDEs) remains prohibitive with black-box Markov chain Monte Carlo (MCMC) methods. We present hIPPYlib-MUQ, an extensible and scalable software framework that contains implementations of state-of-the art algorithms aimed to overcome the challenges of high-dimensional, PDE-constrained Bayesian inverse problems. These algorithms accelerate MCMC sampling by exploiting the geometry and intrinsic low-dimensionality of parameter space via derivative information and low rank approximation. The software integrates two complementary open-source software packages, hIPPYlib and MUQ. hIPPYlib solves PDE-constrained inverse problems using automatically-generated adjoint-based derivatives, but it lacks full Bayesian capabilities. MUQ provides a spectrum of powerful Bayesian inversion models and algorithms, but expects forward models to come equipped with gradients and Hessians to permit large-scale solution. By combining these two complementary libraries, we created a robust, scalable, and efficient software framework that realizes the benefits of each and allows us to tackle complex large-scale Bayesian inverse problems across a broad spectrum of scientific and engineering disciplines. To illustrate the capabilities of hIPPYlib-MUQ, we present a comparison of a number of MCMC methods available in the integrated software on several high-dimensional Bayesian inverse problems. These include problems characterized by both linear and nonlinear PDEs, various noise models, and different parameter dimensions. The results demonstrate that large (~ 50×) speedups over conventional black box and gradient-based MCMC algorithms can be obtained by exploiting Hessian information (from the log-posterior), underscoring the power of the integrated hIPPYlib-MUQ framework.

97 MATHEMATICS AND COMPUTING↗