Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Multi-Node Modeling of Cryogenic Tank Pressurization System Using Generalized Fluid System Simulation Program

Cryogenic Tanks are pressurized by inert gas such as Helium or Nitrogen to maintain the required pressure of the propellant delivered to the turbo-pump of a liquid rocket engine. Thermo-fluid system simulation tools are used to analyze the pressurization process of a cryogenic tank. Most system level codes (GFSSP and ROCETS) use single node1 to represent ullage which is the gaseous space in the tank. Ullage space in a cryogenic tank is highly stratified because the entering inert gas is at ambient temperature whereas the liquid propellant is at a cryogenic temperature. A single node model does not account for the effect of temperature gradient in the ullage. High fidelity Navier-Stokes based CFD model of Tank Pressurization is not practical for running a long duration transient model with thousands and millions of nodes. A possible recourse is to construct a multi-node model with system level code that can account for ullage stratification.

Bandyopadhyay, Alak↗

Distributed Sensing Node Configuration

A vision and radar sensor integration strategy for surveillance of Advance Air Mobility Mission concept of airspace is contained in the CAD drawing in this publication developed as part of NASA's Transformational Tools and Technology project. High-density airspace operations with multiple aircraft type and potentially noncooperative aircraft require distributed sensor detection and tracking systems to monitor airspace for safe, autonomous flight operations for advanced air mobility, urban air mobility, and high density small uncrewed air systems (SUAS) flight concepts. Contained herein are drawings that are available in the stp and creo file formats of the distributed sensing nodes. Additional dovetail integration is included to enable rapid changing of embedded system. A day in the life node deployment is included in the 2023_last_flight_day.mp4. Please cite this publication if you use these drawings. This sensor configuration methodology is presented in detail in the publication reference below. Chester Dolph, Thomas Lombaerts, Corey A. Ippolito, Vahram Stepanyan, Evan Kawamura, Keerthana Kannan, George Szatkowski, Todd Ferante, Christopher Morris, Federica Vitiello, Flavia Causa, Roberto Opromolla and Giancarmine Fasano. "Distributed Sensor Fusion of Ground and Air Nodes using Vision and Radar Modalities for Tracking Multirotor Small Uncrewed Air Systems and Birds," AIAA 2024-1781. AIAA SCITECH 2024 Forum. January 2024.

Chester V Dolph↗

A Robust and Flexible Design for GCEP Unattended Online Enrichment Monitoring: An OLEM Collection Node Network

Oak Ridge National Laoratory (ORNL) has engineered an on-line enrichment monitor (OLEM) to continuously measure U-235 emissions from the UF6 gas flowing through a unit header pipe of a gas centrifuge enrichment plant (GCEP) as a component of the International Atomic Energy Agency s (IAEA) new generation of technology to support enrichment plant safeguards1. In contrast to other enrichment monitoring approaches, OLEM calibrates and corrects for the pressure and temperature dependent UF6 gas-density without external radiation sources by using the inherent unit header pipe pressure dynamics and combining U-235 gamma-ray spectrometery using a shielded NaI detector with gas pressure and temperature data near the spectrum measurement point to obtain the enrichment of the gas as a function of time. From a safeguards perspective, OLEM can provide early detection of a GCEP being misused for production of highly enriched uranium, but would not detect directly the isolation and use of a cascade within the production unit to produce HEU. OLEM may also reduce the number of samples collected for destructive assay and, if coupled with load cell monitoring, could support isotope mass balance verification and unattended cylinder verification. The earlier paper presented OLEM as one component along with shared load cells and unattended cylinder verification, in the IAEA emering toolbox for unattended instruments at GCEPs1 and described the OLEM concept and how previous modeling studies and field measurements helped confirm the viability of a passive on-line enrichment monitor for meeting IAEA objectives and to support the development of performance targets. Phase I of the United States Support Program (USSP) OLEM project completed a preliminary hardware, software and communications design; phase II will build and test field prototypes in controlled laboratory settings and then at an operational facility. That paper also discussed many of the OLEM collection node commercial off the shelf (COTS) components and summarized the OLEM collection node data security provisions. This paper will discuss a secure and redundant network of OLEM collection nodes, auxiliary detection units and supporting junction boxes distributed throughout a facility for monitoring enrichment on product, feed and tails unit header pipes; the purpose and capability of the built-in Electronic Optical Sealing System (EOSS) network gateway; and a network approach for obtaining reliable and authenticated pressure measurements.

Younkin, James R↗

Sandia Compact Sensor Node (SCSN) v. 1.0

The SCSN communication protocol is implemented in software and incorporates elements of Frequency Division Multiple Access (FDMA), Time Division Multiple Access (TDMA), and Carrier Sense Multiple Access (CSMA) to reduce radio message collisions, latency, and power consumption. Alarm messages are expeditiously routed to a central node as a 'star' network with minimum overhead. Other messages can be routed along network links between any two nodes so that peer-to-peer communication is possible. Broadcast messages can be composed that flood the entire network or just specific portions with minimal radio traffic and latency. Two-way communication with sensor nodes, which sleep most of the time to conserve battery life, can occur at seven second intervals. SCSN software also incorporates special algorithms to minimize superfluous radio traffic that can result from excessive intrusion alarm messages. A built-in seismic detector is implemented with a geophone and software that distinguishes between pedestrian and vehicular targets. Other external sensors can be attached to a SCSN using supervised interface lines that are controlled by software. All software is written in the ANSI C language for ease of development, maintenance, and portability.

HARRINGTON, JOHN↗

Checkpointing for a hybrid computing node

According to an aspect, a method for checkpointing in a hybrid computing node includes executing a task in a processing accelerator of the hybrid computing node. A checkpoint is created in a local memory of the processing accelerator. The checkpoint includes state data to restart execution of the task in the processing accelerator upon a restart operation. Execution of the task is resumed in the processing accelerator after creating the checkpoint. The state data of the checkpoint are transferred from the processing accelerator to a main processor of the hybrid computing node while the processing accelerator is executing the task.

97 MATHEMATICS AND COMPUTING↗

Comparison of plug flow and multi-node stratified tank modeling approaches regarding computational efficiency and accuracy

Residential water heaters contain water stratified by temperature-driven density differences. This implies that a water tank can reach a state in which the top and bottom sections have different temperatures, unless mixing happens. A high degree of thermal stratification can improve the efficiency of some water heaters, by saving the amount of energy required for the heat-up process. Studies of stratification became popular in the 1970s and it remains an active research topic today. The research has led to the development of different models and techniques to better predict and define a stratified tanks behavior. By comparing these models and techniques used previously to describe thermal stratification, the phenomenon could be better understood, exploited, and used to increase efficiency and thermal energy capacity in modern water tanks. From the existing models, we found the one-dimensional standard plug-flow and a multi node model to be appropriate for analyzing the processes of the heat up and cool-down in a water tank. These two models are based on energy balances. This work involved comparing the accuracy and computational effort needed to implement these models. To assess accuracy, we compared both types of existing models to experimental data (also collected in this work) which included a heat up process using an external heat pump. This external process included a layering process that has an eddy diffusivity at five times the rate of thermal diffusion. For this project, we implemented the models in MATLAB, the multi-paradigm numerical computing environment. We quantified model accuracy using the root mean squared error between modeled data and experimental data for six measured tank temperatures. Comparing the accuracy and the computational time taken to run the simulation provides a method to contrast the performance of each model and a way to rate it. The multi node model was run using from 6 to 96 spatial nodes; the plug flow model was run using 1 to 0.001 º C temperature bin sizes. Additionally, timesteps were varied from 4 to 236 s. The results quantify the tradeoff between accuracy and computational time, providing guidance for simulations to intelligently select the best model type and simulation parameters. This research can be used to validate the pre-existing models and possibly improve the modern water tank.

Bulnes, Fernando Karg↗

Carrier and sampling frequency offset estimation for RF communication with crystal-less nodes

When the ultra-low power mm-scale sensor node does not have a crystal oscillator and phase-lock loop, it inevitably exhibits significant carrier frequency offset (CFO) and sampling frequency offset (SFO) with respect to the reference frequencies in the gateway. This disclosure enables efficient real-time calculation of accurate SFO and CFO at the gateway, thus the ultra-low power mm-scale sensor node can be realized without a costly and bulky clock reference crystal and also power-hungry phase lock loop. In the proposed system, the crystal-less sensor starts transmission with repetitive RF pulses with a constant interval, followed by the data payload using pulse-position modulation (PPM). A proposed algorithm uses a two-dimensional (2D) fast Fourier transform (FFT) based process that identifies the SFO and CFO at the same time to establish successful wireless communication between the gateway and crystal-less sensor nodes.

Kim, Hun-Seok↗

Slow Nodes Cost Your Users Valuable Resources. Can You Find Them?

Many High Performance Computing applications have a static load balance which is easy and cheap to implement. When one or a few nodes are not performing properly this makes the whole code slow down to the rate limiting performance of the slowest node. We describe the utilization of a coded called Bugget which has been used on Catamount and the Cray Linux Environment to quickly identify these nodes so they can be removed from the user pool until the next appropriate maintenance period.

99 GENERAL AND MISCELLANEOUS↗

Multiscale wireless sensor node for impedance-based SHM and low-frequency vibration data acquisition

This paper presents recent developments in an extremely compact, wireless impedance sensor node (WID3, Wireless Impedance Device) at Los Alamos National Laboratory for use in impedance-based structural health monitoring (SHM), Sensor diagnostics and low-frequency vibrational data acquisition. The current generation WID3 is equipped with an Analog Devices AD5933 impedance chip that can resolve measurements up to 100 kHz, a frequency range ideal for many SHM applications. An integrated set of multiplexers allows the end user to monitor seven piezoelectric sensors from a single sensor node. The WID3 combines on-board processing using an Atmega1281 microcontroller, data storage using flash memory, wireless communications capabilities, and a series of internal and external triggering options into a single package to realize a truly comprehensive, self-contained wireless active-sensor node for SHM applications. Furthermore, we recently extended the capability of this device by implementing low-frequency analog to digital and digital and analog converters so that the same device can measure structural vibration data. The WID3 requires less than 70 mW of power to operate, and it can operate in various wireless network paradigms. The performance of this miniaturized and portable device is compared to our previous results and its broader capabilities are demonstrated.

42 ENGINEERING↗

Particle removal challenges with EUV patterned mask for the sub-22nm HP node

The particle removal efficiency (PRE) of cleaning processes diminishes whenever the minimum defect size for a specific technology node becomes smaller. For the sub-22 nm half-pitch (HP) node, it was demonstrated that exposure to high power megasonic up to 200 W/cm{sup 2} did not damage 60 nm wide TaBN absorber lines corresponding to the 16 nm HP node on wafer. An ammonium hydroxide mixture and megasonics removes {ge}50 nm SiO{sub 2} particles with a very high PRE, A sulfuric acid hydrogen peroxide mixture (SPM) in addition to ammonium hydroxide mixture (APM) and megasonic is required to remove {ge}28 nm SiO{sub 2} particles with a high PRE. Time-of-flight secondary ion mass spectroscopy (TOFSIMS) studies show that the presence of O{sub 2} during a vacuum ultraviolet (VUV) ({lambda} = 172 nm) surface conditioning step will result in both surface oxidation and Ru removal, which drastically reduce extreme ultraviolet (EUV) mask life time under multiple cleanings. New EUV mask cleaning processes show negligible or no EUV reflectivity loss and no increase in surface roughness after up to 15 cleaning cycles. Reviewing of defect with a high current density scanning electron microscope (SEM) drastically reduces PRE and deforms SiO{sub 2} particles. 28 nm SiO{sub 2} particles on EUV masks age very fast and will deform over time, Care must be taken when reviewing EUV mask defects by SEM. Potentially new particles should be identified to calibrate short wavelength inspection tools, Based on actinic image review, 50 nm SiO{sub 2} particles on top of the EUV mask will be printed on the wafer.

36 MATERIALS SCIENCE↗

Pancreatic neuroendocrine tumors: MR imaging features preoperatively predict lymph node metastasis

Purposes: Predictive factors of lymph node metastasis (LNM) in pancreatic neuroendocrine tumors (pNETs) are not well established. We sought to identify the value of MR imaging features in preoperatively predicting the lymph node metastasis of pNETs. Materials and methods: In this study, we enrolled 108 consecutive patients with pNETs between January 2009 and June 2018. MR morphologic features and quantitative data were evaluated. Predictors of LNM were evaluated using univariate and multivariate logistic regression models. Results: A total of 108 patients with pNETs were finally enrolled, including 82 LNM-negative and 26 LNM-positive patients. Features significantly related to the LNM of pNETs at univariate analysis were tumor size > 2 cm (P = 0.003), Ki-67 > 5% (P = 0.002), non-enhancement pattern (P < 0.001), apparent diffusion coefficient value (P < 0.001), main pancreatic duct dilation (P < 0.001) and pancreatic atrophy (P = 0.032) and extrapancreatic tumor spread (P = 0.001), CNRs during arterial, portal and delay phase (P = 0.005, 0.047, and 0.045, respectively), and histological classification (P = 0.006). At multivariate analysis, non-enhancement pattern (P = 0.019; odds ratio, 6.652; 95% CI 1.369, 32.321) and main pancreatic duct dilation (P = 0.018; odds ratio, 6.745; 95% CI 1.379, 32.991) were independent risk factors for predicting the LNM of pNETs. Conclusion: The non-enhancement characteristic and main pancreatic duct dilation appear to be linked with LNM in pNETs. These radiological predictors can be easily obtained preoperatively, and may help to avoid missing pNETs with a high risk of LNM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Activin type IB receptor signaling in prostate cancer cells promotes lymph node metastasis in a xenograft model

Highlights: Black-Right-Pointing-Pointer ActRIB signaling induces Snail and S100A4 expressions in prostate cancer cells. Black-Right-Pointing-Pointer The prostate cancer cell lines expressing an active form of ActRIB were established. Black-Right-Pointing-Pointer ActRIB signaling promotes EMT and lymph node metastasis in xenograft model. -- Abstract: Activin, a member of the transforming growth factor-{beta} family, has been known to be a growth and differentiating factor. Despite its pluripotent effects, the roles of activin signaling in prostate cancer pathogenesis are still unclear. In this study, we established several cell lines that express a constitutive active form of activin type IB receptor (ActRIBCA) in human prostate cancer cells, ALVA41 (ALVA-ActRIBCA). There was no apparent change in the proliferation of ALVA-ActRIBCA cells in vitro; however, their migratory ability was significantly enhanced. In a xenograft model, histological analysis revealed that the expression of Snail, a cell-adhesion-suppressing transcription factor, was dramatically increased in ALVA-ActRIBCA tumors, indicating epithelial mesenchymal transition (EMT). Finally, mice bearing ALVA-ActRIBCA cells developed multiple lymph node metastases. In this study, we demonstrated that ActRIBCA signaling can promote cell migration in prostate cancer cells via a network of signaling molecules that work together to trigger the process of EMT, and thereby aid in the aggressiveness and progression of prostate cancers.

60 APPLIED LIFE SCIENCES↗

Implementation of extrinsic cohesive zone model (ECZM) in 2D finite-discrete element method (FDEM) using node binding scheme

The combined finite-discrete element method (FDEM) has been widely used for rock fracturing simulations. Conventionally, FDEM is realized using the intrinsic cohesive zone model (ICZM); however, it has the drawback of artificial compliance and high computational expense. As a complement, the extrinsic cohesive zone model (ECZM) is seen to be realized in FDEM recently, whereas the node splitting scheme utilized is cumbersome. Here, within the framework of ICZM-based FDEM, we propose a node binding scheme to efficiently bind the pre-discretized finite elements and thus guarantee the continuum behavior of materials in the elastic stage. The yield surfaces, controlled by ECZM, are dynamically embedded by invoking the pre-inserted cohesive elements. The effectiveness and efficiency of the proposed approach are validated and tested by performing a suite of numerical experiments. Compared with ICZM-based FDEM, the proposed approach can correctly capture material deformation and reduce the computation cost. In contrast to the existing ECZM-based FDEM, the proposed approach can overcome the frequent and complex element topology updating. Finally, this work provides a novel perspective that fully inherits the advantages of both ICZM and ECZM, but circumvents their shortcomings, which guarantees a more efficient and effective simulation of brittle material evolution from continuum to discontinuum.

58 GEOSCIENCES↗

Integrated reactor architecture of conductive network and catalytic nodes to accelerate polysulfide conversion for durable and high-loading Li-S batteries

The development of carbon-based heterogeneous framework host with synergistic catalytic and conductive effects for sulfur cathode is a promising strategy to realize high performance lithium sulfur batteries (LSBs). Here, an integrated reactor architecture with defective carbon nodes (IRA-DC) is designed for serving as high-loading (92.4 wt%) sulfur host. The hierarchical porous IRA-DC consists of untangled conductive carbon nanotube network and Co/N co-doped catalytic nodes with high dispersity. Therein the optimization of electric field distribution and homogenization of adsorption-catalysis sites offer the multi-electron conversion reaction of polysulfides with excellent kinetics and stability. The resultant IRA-DC/S cathode enables a high areal capacity of 8.86 mAh cm -2 under ultra-high sulfur loading (13.1 mg cm -2 ) and lean electrolyte (8 μL mg sulfur -1 ). It also displays a long-term cycling performance (1200 cycles at 1 C) and ultrahigh rate performance up to 20 C (with a capacity of 473.6 mAh g -1 ). In conclusion, this work provides an electrode building strategy by optimizing the environments of heterogeneous electrocatalysis and micro electric field to activate the polysulfide conversion efficiency and utilization of high-loading sulfur in monolithic sulfur-carbon cathodes.

25 ENERGY STORAGE↗

Utility of Positron Emission Tomography Compared With Mediastinoscopy for Delineating Involved Lymph Nodes in Stage III Lung Cancer: Insights for Radiotherapy Planning From a Surgical Cohort

Purpose: Mediastinoscopy is routinely carried out on the majority of nonmetastatic, non-small-cell lung cancer (NSCLC) patients in our institution. We used the results of mediastinoscopy from a Stage III NSCLC cohort to assess the reliability of positron emission tomography (PET) scans at identifying involved mediastinal lymph nodes (MLN) when used during radiotherapy planning. Methods and Materials: Mediastinoscopy was the gold standard. Characteristics of PET were calculated for nodal sensitivity. To compare the impact on contouring, theoretical nodal targets (NTs) containing involved MLNs were generated using PET and mediastinoscopy. We determined whether the NT derived from PET (NT-P) was equivalent to, greater than, or less than that seen with the mediastinoscopy (NT-M). Results: Data for 122 patients with Stage III NSCLC, treated between 2000 and 2004, were analyzed. After exclusions, 87 patients with Stage III disease by mediastinoscopy were analyzed. Overall PET sensitivity was 61% and positive predictive value was 94%. Of the 87 patients, 33 (38%) had no abnormal MLN findings by PET. Of 36 Stage IIIA cancer patients, 18 (50%) had NT-P equivalent to NT-M, 10 (28%) had smaller NT-Ps, and 8 (22%) had larger NT-Ps compared with NT-Ms. Of 18 Stage IIIB cancer patients, NTs were equivalent in 6 (34%); in 1 patient (5%) NT-P was larger than the corresponding NT-M, and in 11 (61%) smaller than the corresponding NT-M. Conclusions: In this study PET had modest sensitivity to detect MLN involvement and underestimated the extent of involved nodes for target definition. The role of PET in mediastinal contouring needs to be evaluated prospectively and ideally correlated with a pathology standard.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Clinical Trial of Positron Emission Tomography/Computed Tomography Image-Guided Intensity-Modulated Radiation Therapy for Cervical Carcinoma With Positive Para-Aortic Lymph Nodes

Purpose: To describe a more aggressive treatment technique allowing dose escalation to positive para-aortic lymph nodes (PALN) in patients with cervical cancer, by means of positron emission tomography (PET)/computed tomography (CT)-guided intensity-modulated radiation therapy (IMRT). Here, we describe methods for simulation and planning of these treatments and provide objectives for target coverage as well as normal tissue sparing to guide treatment plan evaluation. Methods and Materials: Patients underwent simulation on a PET/CT scanner. Treatment plans were generated to deliver 60.0 Gy to the PET-positive PALN and 50.0 Gy to the PALN and pelvic lymph node beds. Treatment plans were optimized to deliver at least 95% of the prescribed doses to at least 95% of each target volume. Dose-volume histograms were calculated for normal structures. Results: The plans of 10 patients were reviewed. Target coverage goals were satisfied in all plans. Analysis of dose-volume histograms indicated that treatment plans involved irradiation of approximately 50% of the bowel volume to at least 25.0 Gy, with less than 10% receiving at least 50.0 Gy and less than 1% receiving at least 60.0. With regard to kidney sparing, approximately 50% of the kidney volume received at least 16.0 Gy, less than 5% received at least 50.0 Gy, and less than 1% received at least 60.0 Gy. Conclusions: We have provided treatment simulation and planning methods as well as guidelines for the evaluation of target coverage and normal tissue sparing that should facilitate the more aggressive treatment of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Distribution Analysis of Axillary Lymph Nodes for Three-Dimensional Conformal Radiotherapy With a Field-in-Field Technique for Breast Cancer

Purpose: We previously reported that most of axillary regions could be irradiated by the modified tangential irradiation technique (MTIT). The purpose of this study was to determine whether the three-dimensional conformal radiotherapy (3D-CRT) with a field-in-field technique improves dosimetry for the breast and axillary nodes. Methods and Materials: Fifty patients with left-sided breast cancer were enrolled. With MTIT, we planned the radiation field to be wider in the cranial direction than the standard tangential fields to include the axillary regions. With 3D-CRT, a field-in-field technique was used to spare the heart and contralateral breast to the extent possible by applying the multileaf collimator manually. Dose-volume histograms were compared for the breast, axillary region, heart, lung, and other normal tissues. Results: There were no significant differences in the percent volume of the breast receiving >90% of the prescribed dose (V90) between MTIT and 3D-CRT. The mean V90 of the level I to III axillary regions were increased from 93.7%, 48.2%, and 41.3% with MTIT to 97.6%, 85.8%, and 82.8% with 3D-CRT. 3D-CRT significantly reduced the volume of the heart receiving >30 Gy (mean, 7.6 vs. 15.9 mL), the percent volume of the bilateral lung receiving >20 Gy (7.4% vs. 8.9%), and the volume of other normal tissues receiving >107% of the prescribed dose (0.1 vs. 2.9 mL). Conclusion: The use of 3D-CRT with a field-in-field technique improves axillary node coverage, while decreasing doses to the heart, lungs, and the other normal tissues, compared with MTIT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coverage of Axillary Lymph Nodes in Supine vs. Prone Breast Radiotherapy

Purpose: To compare the dosimetry of target and normal tissue when tangents with the breast tissue were applied in a subset of breast cancer patients who had undergone computed tomography (CT) planning both supine and prone. Methods and Materials: The CT images of 20 patients who had undergone simulation in supine and prone positions were used for planning. The axillary lymph node regions (level I-III), breast tissue, tumor bed, heart, and bilateral lungs were manually contoured. Standard tangent fields were designed for the whole breast to deliver a prescribed dose of 50 Gy. Dose-volume histograms were compared between the two sets. Results: In each patient, coverage of breast tissue and tumor bed was readily achieved by either technique. In either position, treatment of the nodal regions was inadequate. On average, the mean dose to the nodal regions for levels I-III was {approx}50% less in the prone as compared with the supine position. The mean ipsilateral lung volume receiving 95% of the prescribed dose was 6.3% in the supine position compared to 0.43% in the prone position. When planned supine, the mean heart volume receiving 30 Gy was 0.56% compared with 0.30% in the prone position. Conclusions: Planning in either position was found to achieve adequate coverage of the breast tissue and tumor bed for all patients. Lung was better spared prone. Coverage of axillary nodes was inadequate in either position, but further reduced in the prone vs. supine position. The choice of optimal setup should take into considerations stage and risk of nodal recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗