Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Analytic Modeling of a Deep Shielding Problem

Previous generations of scientists would make tremendous efforts to simplify non-tractable problems and generate simpler models that preserved the fundamental physics. This process involved applying assumptions and simplifications to reduce the complexity of the problem until it reached a solvable form. Each assumption and simplification was chosen and applied with the intent to preserve the essential physics of the problem, since, if the core physics of the problem were eliminated, the simplified model served no purpose. Moreover, if done correctly, solutions to the reduced model would serve as useful approximations to the original problem. In a sense, solving the simple models laid the ground-work for and provided insight into the more complex problem. Today, however, the affordability of high performance computing has essentially replaced the process for analyzing complex problems. Rather than "building up" a problem by understanding smaller, simpler models, a user generally relies on powerful computational tools to directly arrive at solutions to complex problems. As computational resources grow, users continue trying to simulate new, more complex, or more detailed problems, resulting in continual stress on both the code and computational resources. When these resources are limited, the user will have to make concessions by simplifying the problem while trying to preserve important details. In the context of the Monte Carlo N-Particle radiation transport simulation tool, simplifications typically come as reductions in geometry, or by using variance reduction techniques. Both approaches can influence the physics of the problem, leading to potentially inaccurate or non-physical results. Errors can also be introduced as a result of faulty input into a computational tool: something as simple as transposing numbers in a tally input can result in incorrect answers. In this paradigm, reduced complexity computational and analytical models still have an important purpose. The explicit form of an analytic solution is arguably the best way to understand the qualitative properties of simple models. In contrast to "building up" a complex problem through understanding simpler problems, results from detailed computational scenarios can be better explained by "building down" the complex model through simple models rooted in the fundamental or essential phenomenology. Simplified analytic and computational models can be used to 1) increase a user's confidence in the computational solution of a complex model, 2) confirm there are no user input errors, and 3) ensure essential assumptions of the simulation tool are preserved. This process of using analytic models to develop a more valuable analysis of simulation results is named the results assessment methodology. The utility of the results assessment methodology and a complimentary sensitivity analysis is exemplified through the analysis of the neutron flux in a dry used fuel storage cask. This application was chosen due to current scientific interest in used nuclear fuel storage.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark for Fuel Shuffling and Depletion for Pebble-Bed Reactors

Pebble bed reactors have specific operational characteristics when their fuel-cycle and fueling operations are considered. They are specifically distinguished by other type of nuclear reactor designs by their online fuel recycling scheme, where the fuel elements that have not yet reached discharge burnup can be reloaded and recycled continuously during normal operation. The fuel in a pebble bed reactor is not stationary and stochastically moves through the core once or several times during its lifetime, which allows them to operate without requiring a large excess reactivity hold for the burnup. However, this characteristic of pebble bed reactors introduces challenges in simulation, as each pebble can take many different trajectories through the core, its composition depends on the details of the irradiation history that is unique to its aggregated path through the core. For predicting the safety performance characteristics, such as source term, maximum fuel temperatures and fuel failure rates, etc., it is important to accurately incorporate the movement of pebbles through the core during their lifetime in a multi-physics simulation together with other phenomena. The equilibrium core analysis for pebble bed reactors are performed with multi-physics tools including fuel depletion in a multi pass reload coupled to the fuel movement. Currently, there are only a few legacy multi-physics simulation tools that can implement the pebble flow characteristics and perform equilibrium core analysis for pebble bed reactors. However, there are development efforts on-going under Department of Energy's Nuclear Energy Advanced Modelling and Simulation program and also in private industry for including these capabilities into their modelling and simulation tools. Any new development in the modelling and simulation tools needs to be validated by using tools such as experiments, analytical solutions or code-to-code benchmarks. In this work, a code-to-code benchmark for the equilibrium core analysis capability of pebble bed reactors was developed. Multiple cases were identified to capture different fuel cycle strategies that can be used in PBRs. The results of each case are presented in terms of overall equilibrium core characteristics: the discharge burnup; spatial burnup distribution; spatial isotopic distributions; axial and radial neutron flux distributions and power history of fuel elements per pass through the core for both a prototypical pebble bed High Temperature Gas-cooled Reactor and a prototypical pebble bed Fluoride-salt cooled High temperature Reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytic Modeling of a Deep Shielding Problem

Previous generations of scientists would make tremendous efforts to simplify non-tractable problems and generate simpler models that preserved the fundamental physics. This process involved applying assumptions and simplifications to reduce the complexity of the problem until it reached a solvable form. Each assumption and simplification was chosen and applied with the intent to preserve the essential physics of the problem, since, if the core physics of the problem were eliminated, the simplified model served no purpose. Moreover, if done correctly, solutions to the reduced model would serve as useful approximations to the original problem. In a sense, solving the simple models laid the ground-work for and provided insight into the more complex problem. Today, however, the affordability of high performance computing has essentially replaced the process for analyzing complex problems. Rather than "building up" a problem by understanding smaller, simpler models, a user generally relies on powerful computational tools to directly arrive at solutions to complex problems. As computational resources grow, users continue trying to simulate new, more complex, or more detailed problems, resulting in continual stress on both the code and computational resources. When these resources are limited, the user will have to make concessions by simplifying the problem while trying to preserve important details. In the context of the Monte Carlo N-Particle radiation transport simulation tool, simplifications typically come as reductions in geometry, or by using variance reduction techniques. Both approaches can influence the physics of the problem, leading to potentially inaccurate or non-physical results. Errors can also be introduced as a result of faulty input into a computational tool: something as simple as transposing numbers in a tally input can result in incorrect answers. In this paradigm, reduced complexity computational and analytical models still have an important purpose. The explicit form of an analytic solution is arguably the best way to understand the qualitative properties of simple models. In contrast to "building up" a complex problem through understanding simpler problems, results from detailed computational scenarios can be better explained by "building down" the complex model through simple models rooted in the fundamental or essential phenomenology. Simplified analytic and computational models can be used to 1) increase a user's confidence in the computational solution of a complex model, 2) con firm there are no user input errors, and 3) ensure essential assumptions of the simulation tool are preserved. This process of using analytic models to develop a more valuable analysis of simulation results is named the results assessment methodology. The utility of the results assessment methodology and a complimentary sensitivity analysis is exempli fied through the analysis of the neutron flux in a dry used fuel storage cask. This application was chosen due to current scientific interest in used nuclear fuel storage.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and Optimization of a Purification Process to Recover 99 Mo from Low-enriched Uranium

Supported by the DOE-NNSA Office of Material Management & Minimization (M3), a number of domestic entities are pursuing non-highly enriched uranium (non-HEU) production of 99 Mo. As the production technologies of 99Mo pivot toward low-enriched uranium (LEU) or molybdenum targets, new reaction channels and accelerators are being evaluated. Superconducting electron linear accelerators (LINACs) with high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that are capable of inducing photonuclear reactions and LEU fission. A particular advantage of a LINAC is that it does not rely on HEU-fueled reactor cores (which are currently slated for LEU conversion) and can operate on an almost continuous basis. Regarding the chemical purification of 99 Mo from irradiated uranium targets under acidic digestion, there exists a procedure known as Cintichem or modifications thereof with respect to LEU (LEU Modified Cintichem process, LMC). The process relies on a number of selective precipitation steps and column chromatography to purify Mo. It is important to note that LMC prescribes the addition of stable Mo to carry 99 Mo on alpha benzoin oxime, which reduces the specific activity of 99 Mo. This is especially important for processing 99 Mo batches with lower activities (~33 Ci of 99 Mo per batch).

07 ISOTOPE AND RADIATION SOURCES↗

24.1.3.1 - Verification of Spent Fuel Inside Dry Storage Casks by Fast/Epi-thermal Neutron Mapping

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multi-detector scanning array will be built and tested in FY2021 to demonstrate a practical rapid verification system in FY2022.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental Studies of Tritium Diffusivity in Pure and Defective Zircaloy-4 Getters (Tritium Science Program FY2020 Report)

Zirconium (Zr) alloys are extensively used as tritium (T) getters in nuclear reactors due to their low absorption cross section to thermal neutron, good mechanical properties at high temperature and resistant to corrosion in different environmental conditions. Zr alloys have better thermal properties than many other refractory alloys including stainless steel. The nuclear characteristic is simulated, and T is produced in tritium-producing burnable absorber rods (TPBAR) by the irradiation of neutron flux in pressurized water reactor (PWR). T thus produced diffuses through the pellets and is captured by the getter where it chemically reacts with Zr to form metal hydride (ZrTx). These hydrides are brittle and affect adversely the mechanical properties of alloys. In addition to that, mismatch in the lattice structures after hydride formation creates a stress which needs to be considered in component design and their life evaluation. Therefore, understanding the behavior of T and its species becomes significant as fuel burnup is increased, which leads to increase in hydrogen pickup and oxide formation. The transport of T and its species in pure Zr alloys, and in alloys with certain alloying elements and defects are important to understand in order to enhance the performance of the materials.

36 MATERIALS SCIENCE↗

Report on Properties and Microstructure of 3D Printed Inc-718

The report presents the microstructure and mechanical properties of 3D printed Inconel 718 to assess its potential use as a structural material for the Transformation Challenge Reactor (TCR). The structural components near the outlet of the core will experience significant neutron fluxes and outlet coolant temperatures from the hot standby temperature of 300°C to nearly 550°C at the center of the part. These components must support the core in appropriate loading conditions and require structural analysis at relevant temperatures. Strong spatial and chemical heterogeneity was found in as-built (ASB) Inconel 718. Three heat treatments were designed and conducted to simplify the microstructure and determine how each precipitating phase contributed to the overall strength. Baseline mechanical properties were measured from uniaxial tensile tests on subsize SS-J2 specimens at room temperature and at elevated temperatures of 300, 450, and 600°C. Microstructure electron microscopy was performed on ASB Inconel 718 and heat treated to correlate the observed mechanical properties with nanoscale features. Homogenization of the microstructure led to a highly ductile Inconel with lower strength compared with wrought Inconel 718. The tensile properties of additively manufactured 718 using a standard ASTMrecommended heat treatment were consistent with literature and with the ASTM for the properties of this alloy. A higher fraction of the δ phase led to shorter uniform elongation without altering other engineering properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Field Test at INL Cask Farm of Single Detector Fast Neutron Spent Fuel Cask Verification System

Detecting diversion of spent fuel elements in dry storage casks is challenging due to the thick shielding used in cask construction. Measurements on top of the cask to map the underlying arrangement of the fuel elements and looking for anomalous changes over time has proven difficult to achieve using gamma rays due to the high scattering and attenuation from the thick steel structure, weakening information on the present or absence of fuel bundles. Simulations and laboratory experiments suggest that the high-energy neutron flux (>200 keV) measured directly above each fuel bundle is sufficient to produce a position map that enables detection of the present or absence of fuel bundles, and therefore diversion of a spent fuel bundle. A single-detector spent-fuel monitoring technique based on this principle was development at the Lawrence Livermore National Laboratory (LLNL). The INL Cask Farm in the INTEC technical area at Idaho National Laboratory (INL) offers the capability to test this technique on an MC-10 storage cask which has a distribution of full and empty fuel positions. An experimental test plan for the single-detector verification system was developed in consultation with INL personnel to be completed in FY2021. Due to travel advisories related to COVID-19, the experimental test plan was adapted to enable INL personnel to carry out the measurements in consultation with LLNL personnel following shipment of the LLNL system to INL. Field test measurements of the single detector verification system were successfully carried out at the INL cask farm on September 7-9, 2021. This document summarizes results of the field test.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification of Spent Fuel Inside Dry Storage Casks Using Neutron Mapping (2022 Midyear Report)

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multi-detector scanning array will be built and tested to demonstrate a practical rapid verification system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Niowave Flow Testing of the High Power Converter - FY 21

Design work for a 100 kW converter to produce a neutron flux via electron impact on a flowing stream of liquid metal lead-bismuth (LBE) was conducted in FY20. In FY21, the focus shifted to a 20 kW converter which was designed in collaboration with Niowave engineers. A flow visualization model is needed to validate model results for the 20 kW converter and ensure adequate coolant flow over containment structures. This work highlights the mockup that was made with quartz side plates by LANL.

42 ENGINEERING↗

Titanium Material Comparison for Second Target Station Moderators

Two titanium alloys, Ti 15-3-3-3 and Grade 5 Ti, have been analyzed for their neutronic differences after being exposed to neutron fluxes from a 5-year operational period in the Second Target Station (STS)moderators. There are several differences in the original composition of the two alloys where Ti 15-3-3-3contains Cr and Sn and Grade 5 Ti does not. The differences in original composition propagate through the analysis to yield discrepancies in decay power density and decay gamma intensity density of more than a factor of 3.5 at some times during operation. Immediately after the 5-year operational period, Ti 15-3-3-3has a factor of 3.59 higher intensity of high-energy decay gammas than Grade 5 Ti, and Ti 15-3-3-3 also has a factor of 3.53 higher decay power than Grade 5 Ti. After 1 year of shutdown, Ti 15-3-3-3 has a 48% higher intensity of high-energy decay gammas and a 86% greater decay power density when compared with Grade 5 Ti. The quantities-of-interest in this report are per unit volume and the overall volume of titanium should be considered when making engineering judgment on final titanium alloy selection.

36 MATERIALS SCIENCE↗

Verification of Spent Fuel Inside Dry Storage Casks by Fast/Epi-thermal Neutron Mapping (FY2022 NA-241 Annual Report)

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multidetector scanning array will be built and tested to demonstrate a practical rapid verification system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Purification and Concentration of 99 Mo from a UREX raffinate

The medical isotope 99m Tc ( t ½ = 6.0 h) accounts for over 80% of isotopes used in diagnostic nuclear medicine today and is normally derived from its transient equilibrium parent 99 Mo ( t ½ = 66 h). To reduce U.S. dependence on 99 Mo derived from HEU by foreign suppliers, the NNSA/M3 program—under the American Medical Isotope Production Act—has been tasked with facilitating the work of domestic 99 Mo suppliers that do not utilize HEU. Superconducting electron linear accelerators with high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that can induce photonuclear reactions and LEU fission. After sufficient production intervals, targets can be rotated out and processed while another batch is irradiated. The process flow chemistry is shown in Figure 1. The irradiated U 3 O 8 targets are retrieved and dissolved in HNO 3 ; the volatile fission products are expelled and captured during this step. The HNO 3 liquor bearing the uranyl, fission and activation products is injected into the UREX suite of liquid-liquid extraction banks. The uranyl is partitioned in typical fashion using tri-$\textit{n}$-butyl phosphate (TBP) in a hydrocarbon diluent. The raffinate—comprising mainly 99 Mo and fission products—is then injected into the MoLLE (Molybdenum Liquid-Liquid Extraction) flowsheet, where the Mo is selectively extracted by an organophosphorous acid extractant such as di-(2-ethylhexyl phosphoric acid) (HDEHP). Trace amounts of Nb, Zr, Np, I, and Te are co-extracted. The Mo is stripped using acetohydroxamic acid (AHA) and fed onto an anion exchange column. Following a series of hydroxide, HCl, and oxalic acid wash steps, the Mo can be recovered in NaOH/NaCl. A manuscript describing this process chemistry in more detail was recently published.

07 ISOTOPE AND RADIATION SOURCES↗

Embedded acoustic sensing and monitoring techniques for small modular reactors

The goal of this project was to study the applicability of specific innovative instrumentation techniques for assessing parameters needed for safe small modular reactor operation and safeguarding of nuclear material. Small modular reactor core designs are currently being developed to provide energy more effectively and efficiently than in the past because they can be built as modules at fabrication sites and then transported to a power-producing facility. However, these modules and/or the final core will often be sealed and not accessible again until disposal. Instead of instruments that access the core directly, during and after operation, to monitor flux/dose and structural integrity, as current power plants use, new sensors need to be designed that can be built into the reactor initially to determine operating history, structural integrity through operation of the system, and nuclear material accountancy after shutdown and before disposition of the core. Embedded sensors already exist that can provide neutron flux, gamma dose, and temperatures, but techniques to expand upon these for assessing structural health and material inventory in the system over time need to be developed. Structural health assessments include the detection and imaging of cracks in the components that could eventually cause radioactive fission products to be released.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Neutron Cross Section Measurements at the RPI LINAC [Slides]

Cold polyethylene shows adequate capacity for enhancing sub-thermal neutron flux. Cold moderator system produced high quality thermal cross section measurements. Measurements were performed for polyethylene, polystyrene, Plexiglas, yttrium hydride and beryllium and compared with ENDF/B-VIII.0 TSL evaluations. All data reduction for all measurements was finalized. Future work includes completion of necessary journal publications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsed Sphere Time of Flight Neutron Spectrum Measurements: Blank Run and 1.8 Mean-Free-Path thick Polyethylene Moderating Sphere

From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Science & Technology Review: Awards for Livermore Innovation

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review (S&TR) is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world. In 2021, Lawrence Livermore technologies received three R&D 100 awards, which honor the year’s top 100 innovations from around the world. The feature article beginning on p. 4 describes the Laboratory’s winners: the Multiplicity Counter for Thermal and Fast Neutrons, Flux, and the Optical Transconductance Varistor. The 2021 awards raised the Laboratory’s total R&D 100 awards to 173 since 1978. The R&D 100 logo is reprinted in this issue with permission from R&D World magazine.

24 POWER TRANSMISSION AND DISTRIBUTION↗