Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector

Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below 0.3 keV NR via the asymmetric emission of γ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Additionally, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.

detector calibration↗

Neutron Reconstruction via Blips in Liquid Argon Time Projection Chambers

Neutrons are important in the separation of neutrino and antineutrino in atmospheric neutrino oscillation and in reducing atmospheric-neutrino backgrounds in beyond-standard model searches, but they are not explicitly accounted for in most current LArTPC reconstruction. We present a phenomenological study of neutron activities in liquid argon time projection chamber using detector-response constraints from existing detectors. Leveraging energy deposits from neutron scattering, primarily low-energy localized ,blips, we demonstrate the capability to identify neutrons and to reconstruct neutron multiplicity in neutrino interactions. Including neutron information significantly improves neutrino-antineutrino separation and the identification of rare events against atmospheric-neutrino backgrounds, motivating neutron-aware reconstruction for future high-precision LArTPC analyses.

Hernandez Morquecho, Miguel Angel [Minnesota U.] (↗

MENUS—Materials engineering by neutron scattering

Materials engineering by neutron scattering (MENUS) at the second target station will be a transformational high-flux, versatile, multiscale materials engineering diffraction beamline with unprecedented new capabilities for the study of complex materials and structures. It will support both fundamental and applied materials research in a broad range of fields. MENUS will combine unprecedented long-wavelength neutron flux and unique detector coverage to enable real-time studies of complex structural and functional materials under external stimuli. The incorporated small angle neutron scattering and transmission/imaging capabilities will extend its sensitivity to larger length scales and higher spatial resolution. Multimodal MENUS will provide crystallographic and microstructure data to the materials science and engineering community to understand lattice strain/phase transition/microstructure/texture evolution in three orthogonal directions in complex material systems under combined extreme applied conditions. Finally, the capabilities of MENUS will open new scientific opportunities and meet the research needs for science challenges to enable studies of a range of phenomena and answer the key questions in material design/exploration, advanced material processing, transformative manufacturing, and material operations of national impacts in our daily life.

47 OTHER INSTRUMENTATION↗

Micro cavity fission chamber radiation detection system

A radiation detector to monitor the neutron flux of a nuclear reactor or other high-radiation environment, that can withstand the high temperatures and radiation fields of such environment, is provided. A small dielectric substrate with a low neutron-activation cross section is provided. The substrate is coated with a neutron conversion material, such as uranium oxide or thorium oxide. One or more substrates form a micro-sized detection cavity that is filled with a detection gas. A voltage is provided across anode and cathode wires in the detection cavity. A neutron absorbed in the conversion material may release reaction products into the gas, causing ionization of the gas which then produces a current or voltage signal. The small detector volume minimizes energy deposition into the detection gas by competing particles such as gamma rays, fast electrons, and beta particles, and therefore minimizes false counts while retaining large signals from neutron interactions.

McGregor, Douglas S.↗

New NDA Methods for Thorium Fuel Cycle Safeguards (Final Report)

This project developed portable Neutron Resonance Transmission Analysis (pNRTA) as a new non-destructive assay (NDA) method for thorium fuel cycles safeguards and other applications where multiple isotopes must be measured when present together. pNRTA leverages epithermal neutron resonances to assay multiple safeguards-relevant isotopes (e.g., 233 U and 235 U) when they are present together in a sample. Existing techniques are challenged by this task, driving the need for new active interrogation methods. With selected detectors, pNRTA works in high gamma-ray backgrounds from fission and activation products and 232 U progeny expected in thorium fuel cycle samples. This project leveraged a pNRTA system developed at Pacific Northwest National Laboratory (PNNL) and collaboration with the Massachusetts Institute of Technology (MIT). The system uses a commercially available deuterium-tritium (DT) neutron generator at short standoff (2 m). Key achievements in this project included: first-of-a-kind pNRTA quantitative measurements of 233 U oxide samples, an assessment of neutron detector technologies suitable for pNRTA in high gamma-ray background environments, experimentally demonstrating quantitative assay of samples containing 233 U and 235 U, and modeling studies showing the applicability of pNRTA to a wide range of material forms. Further, a custom algorithm was developed at MIT, which provided mean bias of 9% and relative standard deviation of 36% in assaying 233 U, 235 U, 238 U, and 232 Th content in eight measured samples. These outcomes form a solid technical basis for pNRTA as a new promising capability for international safeguards verification that is portable, non-destructive, quantitative, and isotopic specific.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Xenon-Doped Liquid Argon TPCs as a Neutrinoless Double Beta Decay Platform

Next-generation large liquid argon time-projection chambers offer an unprecedented amount of active detector mass in a deep location. Modifications to the detector design could enable neutrinoless double beta decay searches, with the possibility of reaching the normal ordering region. These modifications include adding external neutron moderation, filling the detector with argon depleted in Ar42, doping with xenon, and a method to achieve percent-level energy resolution at the MeV scale. One way to achieve this desired level of energy resolution is to introduce a photosensitive dopant into the argon, converting the isotropic scintillation photons into a directional ionization signal. This would enhance the achievable energy resolution in large LArTPCs, and would lead to sizeable improvements to many facets of the broad physics program such a detector could offer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs . Current and Voltage

The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. It is important to measure and understand the dependence of the neutron production rate on the accelerator current and voltage. In this study we evaluated neutron production with an absolutely calibrated liquid scintillator neutron spectrometer (BTI N-Probe), an absolutely calibrated He-3 detector surrounded by HDPE shells (Detec Nested Neutron Spectrometer, NNS), and two uncalibrated ZnS fast neutron scintillators (EJ-410), for both A3082 and A3083 sealed tubes. Here we also modeled the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental results showed an essentially linear dependence on beam current, as expected. A 3.59 ±0.08 power law dependence on the operating voltage was measured, in effective agreement with the modeled value of 3.5. A series of absolute NNS and N-Probe measurements, matched against MCNP calculations, showed that the A3083 and A3082 tubes provide a maximum neutron yield of 8.2 × 10 8 n/s and 4.7 × 10 8 n/s respectively, with estimated uncertainty of ±10%.We showed, through modeling, that tritium decay is not a significant consideration for tubes, such as these, with lifetimes of less than 10 years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility study to use neutron capture for an ultralow energy nuclear-recoil calibration in liquid xenon

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. Further, the measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted γ cascades can provide the nuclei with up to 0.3 keV nr of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron heating assessment in Minerve reactor by using alanine/ESR dosimetry

In the framework of the ICERR (International Center based on Research Reactors) project, the effect of neutron/gamma irradiation on material and dosimeters has been studied. In this work, we explore the alanine dose-response in the core of the MINERVE research reactor at the CEA Cadarache and we investigate the neutron heating effects in order to evaluate alanine neutron sensitivity. The measured dose of the alanine detector in the mixed gamma-neutron field was estimated by electron spin resonance spectrometry (ESR) with reference to an absorbed dose in water from a 60 Co gamma-ray beam. The experimental sources of uncertainties were reduced by using the optimum conditions of charged-particle equilibrium (CPE), obtained by introducing alanine dosimeters into the aluminum pillbox. Cavity correction factors and dose components were evaluated by the Monte Carlo code MCNP. The calculation showed an underestimated neutron dose with a (C/E) value of about 0.993 +/- 10.83%(k = 1). Results indicate that the fast neutron dose, mainly due to elastic neutron scattering on hydrogen nuclei, represents about 70% of the total dose, while the gamma dose was found to be around 45% of the neutron dose. Additionally, the neutron relative efficiency (REn) to 60 Co gamma-radiation was estimated to be 0.544 +/- 8%(k = 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fast neutron leakage spectra of the EUCLID experiment

Special nuclear material in sub-critical and critical configurations measured in integral experiments are important for validation and adjustment of nuclear data. Many different evaluations of nuclear data exist, and these different evaluations can provide different values for individual cross sections that vary due to the uncertainties in differential experiments or lack of such data. For integral experiments, differences in these individual cross sections can have compensating errors, which lead to the same answer. One example of this is the Jezebel critical assembly, where k eff of the system is correctly computed by both ENDF/B-VIII.0 and JEFF-3.3, despite having substantially different underlying evaluated values for specific reactions (such as elastic and inelastic cross sections). To reduce compensating errors in nuclear data, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project has utilized machine learning to design a set of sub-critical and critical experiments. These experiments include slab- and cube-like configurations of 239 Pu in the form of the ZPPR plates. Six different responses were measured on a total of thirteen different configurations. One of these responses, the neutron leakage spectrum, was measured using an EJ301D detector. Finally, the results of the neutron leakage spectra show good agreement (within 1–2 σ ) with the expected spectrum from simulations and will be used in the subsequent nuclear data adjustment done by the EUCLID team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Activation Diagnostics for High Energy X-ray and Neutron Measurements

Nuclear activation is a vital tool for diagnosing the properties of high-energy particles and photons. We investigate several potential reactions and suitable activation materials that could be used to simultaneously measure both neutrons and high-energy bremsstrahlung x-rays using one detector. Such a diagnostic would be valuable and practical for several facilities capable of creating such high-energy neutrons and x-rays. Laser-generated sources, such as NIF(-ARC) or Omega(-EP), have been shown to be capable of creating high-energy x-rays via high-intensity laser interactions and neutrons via DT fusion reactions. Furthermore, current laser technology is driving the demand for higher repetition rate diagnostics, hence we further constrain reaction/activation selections to accommodate high-repletion rate experiments. Our investigation will concentrate on identifying potential short half-life activation materials associated with high-energy x-ray reactions that could be incorporated into the existing realtime neutron activation detectors (RTNADs), an array of 48 activation detectors positioned around the NIF target chamber used to measure the DT neutron yield isotropy. We have identified two materials, gold and neodymium, that appear to be the best candidates to complement the RTNADs, by adding a new high-energy x-ray measurement capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First observation of isolated nuclear recoils following neutron capture for dark matter calibration

Low-energy nuclear recoils (NRs) are hard to measure, because they produce few e - /h + pairs in solids—i.e., they have low “ionization yield.” A silicon detector was exposed to thermal neutrons over 2.5 live days, probing NRs down to 450 eV. The observation of a neutron capture-induced component of NRs at low energies is supported by the much-improved fit upon inclusion of a capture NR model. This result shows that thermal neutron calibration of very low recoil energy NRs is promising for dark matter searches, coherent neutrino experiments, and improving understanding of ionization dynamics in solids.

79 ASTRONOMY AND ASTROPHYSICS↗

An Integrated Approach to Precision Neutron Measurements in a Dynamic Environment [Slides]

Any quantity of special nuclear material must be accurately quantified for health, safety, and security concerns. High-Level Neutron Coincidence Counters (HLNCCs) are detectors used for assaying the mass of special nuclear material. HLNCCs record a neutron count rate over some period of time which is compared to a calibration curve to determine the quantity of special nuclear material present within the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Leakage Spectra Sensitivities for ICSBEP Benchmarks

Neutron leakage spectra have been measured, simulated, and investigated by many groups. These spectra have many uses, including determining shielding requirements and calculating dose for radiation protection purposes, validating nuclear data, and determining material composition. It has even been proposed to use measurements of neutron leakage spectra to determine the soil composition of Mars. As part of the Los Alamos National Laboratory (LANL) Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) Laboratory Directed Research Development (LDRD) project, the authors are working on developing methods to calculate sensitivities to neutron leakage spectra. This may allow nuclear data evaluators to better use neutron leakage spectra data to constrain or adjust nuclear data. This may also be particularly useful as many neutron leakage spectra measurements do not require fissile material and can be performed with well characterized neutron sources. Neutron leakage spectra measurements are usually performed by placing a detector at the outside of a nuclear system. This may be a reactor, a neutron generator, or a neutron source. Certain detection systems can use pulse height data to infer neutron energies, other detector systems rely on other ways of determining neutron energy (for example, a Bonner sphere with multiple moderator thicknesses can be used to measure neutron spectrum). These measurements typically rely on some unfolding of the measured results. For pulsed systems like the "Livermore Pulsed Spheres," time-of-flight information can also help to constrain the neutron energy spectra data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Irradiation Results of Commercial Neutron and Gamma Sensors at the Ohio State University Research Reactor

This report serves to present the evaluation results of commercial radiation detectors (SPNDs) with the potential to accomplish the data objectives—having sufficient gamma and fast neutron sensitivity—at temperatures near 650°C. The detectors chosen for evaluation are gamma ion chambers from Exosens (previously known as Photonis) models CRGA11 and CRGE32 and tantalum-based self-powered neutron detectors (Ta-SPND) from Mirion. The evaluation was performed in a series of heat irradiations from ambient to 850°C in the 9.5-inch dry tube furnace at the Ohio State University Research Reactor (OSURR). Ion chamber counting curves were measured to evaluate sensor operability at temperature. Detector sensitivity to reactor power and temperature were measured and presented in curve fit parameters. The curve fit equations were used to identify the suggested operational temperatures based on reactor power. Overall, it was evaluated that the CRGA11 was not significantly affected by temperatures up to 650°C and is operable—with higher temperature-contributed signals—up to 700°C. The CRGE32 was more affected by the high temperatures compared to the CRGA11. As a result of increasing temperature, the leakage current was a dominating factor. While the detector can operate up to 600°C and 700°C with lowered high voltage, it is not recommended unless a suitably strong gamma flux field is present. Finally, Ta SPND did not demonstrate good performance beyond 350°C due to the presence of an unknown phenomenon at changing temperatures. The study of the phenomenon is an active research topic outside the scope of this project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

High Multiplication Neutron Noise Measurements Using the 7uPCX Assembly

The Seven Percent Critical Experiment, or 7uPCX, is a system that mimics the physics of light water nuclear reactor systems by using uranium dioxide fuel pins at an enrichment of approximately 7%. 7uPCX is often used for benchmarking and nuclear data purposes. As part of a collaboration between Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Sandia National Laboratories, and the Institut de Radioprotection et de Sûreté Nucléaire, measurements were performed in support of a high-multiplication, subcritical benchmark candidate for a thermal system. The measurements were completed by making subcritical configurations using the fuel loading pattern of a well-documented configuration of the Seven Percent Critical Experiment at Sandia National Laboratories, which exists as a benchmark in the International Criticality Safety Benchmark Evaluation Project handbook. These measurements, which aimed to capture multiplications ranging from approximately 10 to 1,000, also serve as an intercomparison between both the fielded detector systems and analysis methodologies with the goal of better characterizing the detectors and their ability to capture the state of the criticality these types of systems. Los Alamos National Laboratory’s measurements for this collaboration were made with five linked helium-3 based neutron multiplicity detectors placed on the periphery of the reactor tank beyond the infinite reflector thickness of water, and four organic scintillators placed in dry-wells in-reactor near the edge of the upper fuel grid plate. This work captures the Los Alamos National Laboratory measurements, the Rossi-α and Feynman-Y results, provides an intercomparison between the results of the 3 He neutron detectors and the organic scintillators, compares to simulation where possible, and expands on future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗