Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Multiplication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A Smoking Gun in the Carina Nebula

The Carina Nebula is one of thc youngest, most active sites of massive star formation in our Galaxy. In this nebula, we have discovered a bright X-ray source that has persisted for approx.30 years. The soft X-ray spectrum. consistent with kT approx.130 eV blackbody radiation with mild extinction, and no counterpart in the near- and mid-infrared wavelengths indicate that it is a, approx. 10(exp 6)-year-old neutron star housed in the Carina Nebula. Current star formation theory does not suggest that the progenitor of the neutron star and massive stars in the Carina Nebula, in particular (eta)Car, are coeval. This result demonstrates that the Carina Nebula experienced at least two major episodes of massive star formation. The neutron star would be responsible for remnants of high energy activity seen in multiple wavelengths.

Hamaguchi, Kenji↗

The HTR-Proteus Benchmark: Analysis and Use as a Verification and Validation Case

This presentation outlines the evaluation and application of the HTR-Proteus benchmark as a verification and validation (V&V) case for advanced reactor modeling tools. The work supports the U.S. Department of Energy’s HALEU Availability Program (HAP) and the joint DOE/NRC DNCSH project, which aims to reduce criticality safety uncertainties in commercial-scale HALEU fuel cycle and transportation systems. The HTR-Proteus experiments, conducted at the Paul Scherrer Institute, provide high-fidelity data for TRISO-fueled, graphite-moderated pebble bed reactors with high neutron leakage—conditions relevant to HALEU transport scenarios. This study focuses on Cores 4.2 and 4.3 of the HTR-Proteus benchmark, analyzing key sources of uncertainty including pebble packing, TRISO particle positioning, and core height. Using Project Chrono for realistic pebble geometries and Serpent, SHIFT, and MCNP for neutronics simulations, the study quantifies the impact of these uncertainties on the effective multiplication factor (keff). Results show that a sample size of 110 pebble configurations is sufficient to converge keff, with ±30 pcm uncertainty due to packing randomness. TRISO positioning and core height variations also significantly influence keff, highlighting the importance of detailed modeling in V&V efforts. The benchmark serves as a valuable test case for validating the Griffin reactor physics code and improving confidence in HALEU system simulations.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The mechanisms of catalysis and ligand binding for the SARS-CoV-2 NSP3 macrodomain from neutron and x-ray diffraction at room temperature

The nonstructural protein 3 (NSP3) macrodomain of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (Mac1) removes adenosine diphosphate (ADP) ribosylation posttranslational modifications, playing a key role in the immune evasion capabilities of the virus responsible for the coronavirus disease 2019 pandemic. Here, we determined neutron and x-ray crystal structures of the SARS-CoV-2 NSP3 macrodomain using multiple crystal forms, temperatures, and pHs, across the apo and ADP-ribose–bound states. We characterize extensive solvation in the Mac1 active site and visualize how water networks reorganize upon binding of ADP-ribose and non-native ligands, inspiring strategies for displacing waters to increase the potency of Mac1 inhibitors. Determining the precise orientations of active site water molecules and the protonation states of key catalytic site residues by neutron crystallography suggests a catalytic mechanism for coronavirus macrodomains distinct from the substrate-assisted mechanism proposed for human MacroD2. These data provoke a reevaluation of macrodomain catalytic mechanisms and will guide the optimization of Mac1 inhibitors.

60 APPLIED LIFE SCIENCES↗

Unusual Exchange Couplings and Intermediate Temperature Weyl State in Co 3 Sn 2 S 2

Understanding magnetism and its possible correlations to topological properties has emerged to the forefront as a difficult topic in studying magnetic Weyl semimetals. Co 3 Sn 2 S 2 is a newly discovered magnetic Weyl semimetal with a kagome lattice of cobalt ions and has triggered intense interest for rich fantastic phenomena. In this study, we report the magnetic exchange couplings of Co 3 Sn 2 S 2 using inelastic neutron scattering and two density functional theory (DFT) based methods: constrained magnetism and multiple-scattering Green’s function methods. Co 3 Sn 2 S 2 exhibits highly anisotropic magnon dispersions and linewidths below T C , and paramagnetic excitations above T C . The spin-wave spectra in the ferromagnetic ground state is well described by the dominant third-neighbor “across-hexagon” J d model. Our density functional theory calculations reveal that both the symmetry-allowed 120° antiferromagnetic orders support Weyl points in the intermediate temperature region, with distinct numbers and the locations of Weyl points. Our study highlights the important role Co 3 Sn 2 S 2 can play in advancing our understanding of kagome physics and exploring the interplay between magnetism and band topology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single Grid Error Estimation for Neutron Transport Solvers

The method of nearby problems (MNP) is a solution verification technique that does not require the use of multiple spatial grids. To estimate spatial discretization error without requiring a high-fidelity spatial grid, an analytical curve fit is interpolated from the numerical solution. The residual between the curve fit solution and numerical solution is calculated and added as an additional source term to the governing equation. The nearby solution is estimated using the updated source term and boundary conditions to remain consistent with the curve fit interpolation. The nearby solution can be compared to the curve fit solution as a discretization error estimation while using a single spatial grid. Without the use of higher fidelity spatial grids, the MNP is able to approximate the spatial discretization error, a facet of solution verification. The application of the method of nearby problems is presented for one- and two-dimensional neutron transport problems for both fixed source and criticality problems on the spatial variable. The fixed source results demonstrate the effectiveness of nearby problems for spatial error identification using the discrete ordinates method. Criticality results are shown to identify area of high spatial error for the C5G7 problem as well as for the discrete ordinates solver. A novel approach of combining the capabilities of Monte Carlo with the discrete ordinates nearby problems is presented for one- and two-dimensional fixed source problems. In conclusion, the MNP demonstrates its effectiveness at identifying spatial error on a single structured grid with a wide variety of neutron transport problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Passive Neutron Instrumentation and Applications

This chapter presents a description of most of the instruments that are currently in use for the measurement of plutonium and uranium using passive methods (without an external source). This includes the acquisition electronics as well as Singles counting methods, coincidence counting methods and multiplicity counting methods. The Singles counting applications include the measurement of waste and curium bearing materials. The coincidence counting applications include bulk plutonium, bulk uranium, waste and holdup measurements and fresh fuel assemblies. The multiplicity application description includes advantages and disadvantages and multiplicity detector design. There is also a description of some non-3He systems. The chapter concludes with a description of additional concepts: neutron imagers, list-mode data analysis, distributed source term analysis, unattended monitoring and MCNP modeling for detector design.

Coincidence shift register↗

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗

Lasers for the observation of multiple order nuclear reactions

Nuclear reaction rates become nonlinear with respect to flux (cm −2 s −1 ) in extreme environments such as those found during stellar nucleosynthesis and terrestrial nuclear detonations. To observe these effects directly in the laboratory, extremely high particle fluences (cm −2 ) are necessary but not sufficient. Reactor-based neutron sources, such as the Institut Laue-Langevin’s high-flux neutron reactor, were previously the closest to meeting this challenge, albeit over ∼hour time scales. In ultra-high flux environments, where multiple reactions occur on picosecond time scales, nuclei are unable to return to their ground states between reactions; consequently, reactions take place on excited nuclei. To accurately model high-flux environments, data on the cross-sections of excited nuclear states are required, which differ significantly from those of ground states due to spin/parity effects. In order to replicate these effects in the laboratory, short high-fluence pulses on the order of the lifetime of a typical nuclear excited state (generally ≲1 ns) are required. Particle beams generated by high-intensity lasers are uniquely positioned to meet this need with the potential to produce fluences of 10 17 protons/cm 2 and 10 22 neutrons/cm 2 over a few pico-seconds or less. In addition to providing a quantitative analysis of the rates of multiple rapid reactions in general, the present work examines a number of laser-based experiments that could be conducted in the near future to observe multiple rapid reactions for laboratory-based astrophysics and the measurement of exotic cross-sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of techniques for gantryless associated-particle imaging

To move fast-neutron radiography using the associated-particle imaging technique from the laboratory to the field, the development of new analysis techniques is required. In particular, the relative positions of the source and detectors need to be determined when they have been placed by hand, the normalization for a particular source–detector geometry needs to be determined without a measurement in the same geometry with no object present, and accurate image stitching is required when multiple detector positions are necessary to image an object. The present work describes methods that employ transmission neutron data to localize a fast-neutron imaging panel with respect to the neutron source, calculate a normalization for a given source–detector geometry, stitch images together, and describes the required system calibrations. The reported techniques enable in-field neutron radiography for cases in which the source–detector geometry is not well known a priori and where operational constraints preclude a normalization measurement.

Heath, Matthew↗

Mapping periplasmic binding protein oligosaccharide recognition with neutron crystallography

Numerous studies have shown how periplasmic binding proteins (PBPs) bind substrates with exquisite specificity, even distinguishing between sugar epimers and anomers, or structurally similar ions. Yet, marked substrate promiscuity is also a feature encoded in some PBPs. Except for three sub-Ångström crystal structures, there are no reports of hydrogen atom positions in the remaining (> 1000) PBP structures. The previous X-ray crystal structure of the maltodextrin periplasmic-binding protein from Thermotoga maritima (tmMBP) complexed with oligosaccharide showed a large network of interconnected water molecules stretching from one end of the substrate binding pocket to the other. These water molecules are positioned to form multiple hydrogen bonds, as well as forming interactions between the protein and substrate. Here we present the neutron crystal structure of tmMBP to a resolution of 2.1 Å. This is the first neutron crystal structure from the PBP superfamily and here we unambiguously identify the nature and orientation of the hydrogen bonding and water-mediated interactions involved in stabilizing a tetrasaccharide in the binding site. More broadly, these results demonstrate the conserved intricate mechanisms that underlie substrate-specificity and affinity in PBPs.

59 BASIC BIOLOGICAL SCIENCES↗

Strength and ductility of additively manufactured 316L stainless steel: Impact of neutron irradiation and data variability

Here, this article presents the mechanical properties of additively manufactured (AM) 316L stainless steel processed via the laser powder bed fusion (LPBF) method, focusing on the effects of neutron irradiation on mechanical properties and the variability in strength and ductility data. The rapid melting-solidification process and multiple heating-cooling cycles inherent in LPBF typically result in a fine, metastable microstructure with significant local variability. AM 316L builds of varying thicknesses were fabricated, and SS-J3 miniature tensile specimens were machined from six different locations. These specimens were irradiated with fast neutrons to doses of 2 and 10 dpa at target temperatures of 300 °C and 600 °C. Post-irradiation tensile tests were conducted at room temperature, 300 °C, and 600 °C. Compared to conventional 316L stainless steel, AM 316L exhibited higher initial strength but lower ductility. Irradiation at 300 °C caused significant hardening and prompt necking at yield, with limited uniform ductility, although embrittlement was not observed up to 10 dpa. While neutron irradiation, particularly at 600 °C, increased the variability in strength and ductility data, no clear dependence of mechanical properties on build thickness or sampling location was found—contrary to the conventional perception that AM materials may exhibit high property variability. Furthermore, we observed that the variability in property data for LPBF-processed 316L was relatively low compared to that of wrought 316L stainless steel. This reduced variability in AM 316L steel may be attributed to its highly metastable, stress-containing microstructure, which is discussed in the context of general tensile property variations.

Additively manufactured 316L stainless steel↗

Nanosecond solvation dynamics in a polymer electrolyte for lithium batteries

Solvation dynamics critically affect charge transport. Spectroscopic experiments and computer simulations show that these dynamics in aqueous systems occur on a picosecond timescale. In the case of organic electrolytes, however, conflicting values ranging from 1 to several 100 picoseconds have been reported. We resolve this conflict by studying mixtures of an organic polymer and a lithium salt. Lithium ions coordinate with multiple polymer chains, resulting in temporary crosslinks. Relaxation of these crosslinks, detected by quasielastic neutron scattering, are directly related to solvation dynamics. Simulations reveal a broad spectrum of relaxation times. The average timescale for solvation dynamics in both experiment and simulation is one nanosecond. Here we present the direct measurement of ultraslow dynamics of solvation shell break-up in an electrolyte.

25 ENERGY STORAGE↗

Toward full simulations for a liquid metal blanket: part 2. Computations of MHD flows with volumetric heating for a PbLi blanket prototype at Ha ~10 4 and Gr ~10 12

On the pathway toward full simulations for a liquid metal (LM) blanket, this part 2 extends a previous study of purely magnetohydrodynamic (MHD) flows in a DCLL blanket in reference Chen et al (2020 Nucl. Fusion 60 076003) to more general conditions when the MHD flow is coupled with heat transfer. The simulated prototypic blanket module includes all components of a real LM blanket system, such as supply ducts, inlet and outlet manifolds, multiple poloidal ducts and a U-turn zone. Volumetric heating generated by fusion neutrons is added to simulate thermal effects in the flowing lead–lithium (PbLi) breeder. The MHD flow equations and the energy equation are solved with a DNS-type finite-volume code ‘MHD-UCAS’ on a very fine mesh of 470 × 10 6 cells. The applied magnetic field is 5 T (Hartmann number Ha ~ 10 4 ), the PbLi velocity in the poloidal ducts is 10 cm s –1 (Reynolds number Re ~10 5 ), whereas the maximum volumetric heating is 30 MW m –3 (Grashof number Gr ~ 10 12 ). Four cases have been simulated, including forced- and mixed-convection flows, and either an electrically conducting or insulating blanket structure. Various comparisons are made between the four computed cases and also against the purely MHD flows computed earlier in reference Chen et al (2020 Nucl. Fusion 60 076003) with regards to the (1) MHD pressure drop, (2) flow balancing, (3) temperature field, (4) flows in particular blanket components, and (5) 3D and turbulent flow effects. The strongest buoyancy effects were found in the poloidal ducts. In the electrically non-conducting blanket, the buoyancy forces lead to significant modifications of the flow structure, such as formation of reverse flows, whereas their effect on the MHD pressure drop is relatively small. In the electrically conducting blanket case, the buoyancy effects on the flow and MHD pressure drop are almost negligible.

Physics↗

Compromise of Personal Protective Clothing from Liquid Exposure

Following critiques of multiple personal contamination events from entries into the Oak Ridge National Laboratory’s Spallation Neutron Source transfer bay, it was considered that the most likely causes for contamination were personal protective clothing doffing errors or that moisture (sweat) allowed contamination to wick through the protective clothing. To pursue this issue, radiological protection staff looked more closely, however, at the specific area of the clothing where contamination was highest; under enhanced lighting and photochromic manipulation, there appeared to have been some type of moisture in the area. Recognizing the possibility that moisture may have allowed for migration of contamination through the clothing, further experiments were undertaken to determine under which conditions this transport might have occurred. The objective for this work was to identify the susceptibility of different types of personal protective clothing to various liquids encountered in the workplace.Method: Several tests were performed to determine if perspiration had enabled migration of contamination, and to identify what other liquids might have affected contamination transport. Two layers of personal protective clothing were subjected to static conditions and dynamic conditions, to include active rubbing of the materials while wet. Food dye added to each of the liquids tested enabled visual indications of liquid breakthrough. Additional tests were conducted to see if solid contamination could be transported through the materials along with the liquids. As a result, it was found that all but one type of non-rubberized personal protective clothing in use at Oak Ridge National Laboratory were permanently compromised to some extent by the solvents used for decontamination. It was determined that most common cleaning agents immediately and permanently destroyed the hydrophobic nature of several of the splash-resistant protective clothing materials, allowing for radioactive contamination to penetrate through the material to the worker. Work around wet surfaces or performing wet decontamination will only be performed in protective clothing known to prevent transport of the wetting agent.

61 RADIATION PROTECTION AND DOSIMETRY↗

Incommensurate magnetic orders and topological Hall effect in the square-net centrosymmetric EuGa 2 Al 2 system

Neutron diffraction on the centrosymmetric square-net magnet EuGa 2 Al 2 reveals multiple incommensurate magnetic states (AFM1, 2, 3) in zero field. In applied field, a new magnetic phase (A) is identified from magnetization and transport measurements, bounded by two of the μ 0 H=0 incommensurate magnetic phases (AFM1, helical, and AFM3, cycloidal) with different moment orientations. Moreover, magnetotransport measurements indicate the presence of a topological Hall effect, with maximum values centered in the A phase. Together, these results render EuGa 2 Al 2 a material with noncoplanar or topological spin texture in applied field. X-ray diffraction reveals an out-of-plane (OOP) charge density wave (CDW) below T CDW ~50 K while the magnetic propagation vector lies in plane below T N =19.5 K. Together these data point to a new route to realizing in-plane noncollinear spin textures through an OOP CDW. In turn, these noncollinear spin textures may be unstable against the formation of topological spin textures in an applied field.

36 MATERIALS SCIENCE↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An improved thermionic power conversion system for space propulsion

A concept of an out-of-core thermionic nuclear electric power conversion system for 400 Kwe power level is being investigated for space propulsion applications. Two key features distinguish the power system design from previous thermionic power conversion concepts. First, the thermionic converters are located outside a nuclear reactor with a neutron shield inserted to reduce the radiation level on the thermionic converter matrix. Second, multiple liquid-metal heat pipes are used exclusively for both thermal power transport (from the nuclear reactor to the thermionic converters) and waste heat removal (from the thermionic converters to the space radiator); no mechanical or electromagnetic pumps are involved. The system characteristics are are compared to those of the in-core thermionic reactor system concept. In many aspects, the system characteristics, including specific weight, lifetime, dynamics control and safety features are found to be more desirable than those of the in-core system concept.

Hsieh, T. M.↗