Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Development of neutron measurement in high gamma field using new nuclear emulsion

To precisely measure the neutron emissions from a spent fuel assembly of a fast breeder reactor, we formed nuclear emulsions based on a non-sensitized Oscillation Project with Emulsion tracking Apparatus (OPERA) film with AgBr grain sizes of 60, 90, and 160 nm. The efficiency for {sup 252}Cf neutron detection of the new emulsion was calculated to be 0.7 x 10{sup -4}, which corresponded to an energy range from 0.3 to 2 MeV and was consistent with a preliminary estimate based on experimental results. The sensitivity of the new emulsion was also experimentally estimated by irradiating with 565 keV and 14 MeV neutrons. The emulsion with an AgBr grain size of 60 nm had the lowest sensitivity among the above three emulsions but was still sensitive enough to detect protons. Furthermore, the experimental data suggested that there was a threshold linear energy transfer of 15 keV/{mu}m for the new emulsion, below which no silver clusters developed. Further development of nuclear emulsion with an AgBr grain size of a few tens of nanometers will be the next stage of the present study. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Real-Time Neutron Noise Analysis System for Fuel Debris Removal at Fukushima Daiichi

The decommissioning of Units 1, 2, and 3 at Fukushima Daiichi presents unique challenges, particularly in mitigating the risk of re-criticality during fuel debris removal. Disturbing previously stable debris configurations has the potential to cause changes in the multiplication of the system, necessitating real-time monitoring to ensure operational safety. Current neutron detection systems, primarily passive, are not optimized for continuous real-time analysis and are limited in their ability to detect rapid changes in system reactivity.

Neutron Detection Systems↗

Study of wavelength-shifting chemicals for use in large-scale water Cherenkov detectors

Cherenkov detectors employ various methods to maximize light collection at the photomultiplier tubes (PMTs). These generally involve the use of highly reflective materials lining the interior of the detector, reflective materials around the PMTs, or wavelength-shifting sheets around the PMTs. Recently, the use of water-soluble wavelength-shifters has been explored to increase the measurable light yield of Cherenkov radiation in water. These wave-shifting chemicals are capable of absorbing light in the ultravoilet and re-emitting the light in a range detectable by PMTs. Using a 250 L water Cherenkov detector, we have characterized the increase in light yield from three compounds in water: 4-Methylumbelliferone, Carbostyril-124, and Amino-G Salt. We report the gain in PMT response at a concentration of 1 ppm as: 1.88 {+-} 0.02 for 4-Methylumbelliferone, stable to within 0.5% over 50 days, 1.37 {+-} 0.03 for Carbostyril-124, and 1.20 {+-} 0.02 for Amino-G Salt. The response of 4-Methylumbelliferone was modeled, resulting in a simulated gain within 9% of the experimental gain at 1 ppm concentration. Finally, we report an increase in neutron detection performance of a large-scale (3.5 kL) gadolinium-doped water Cherenkov detector at a 4-Methylumbelliferone concentration of 1 ppm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Theoretical Prerequisites for PIK Reactor Subcriticality Control Aided by Spectral Noise Analysis

The possibility of measuring and controlling PIK reactor subcriticality on the basis of spectral analysis of reactor noise is examined. A simple lumped-parameter working model of the reactor and an equivalent noise source in accord with Schottky’s relation are used. Attention is focused on the statistical error of measurement of the spectral density of reactor noise owing to the finite measurement time and the random nature of neutron detection in a detector. It is shown that in connection with this error the measurements will require a long time and high-sensitivity detectors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NeutronSTARS: A segmented neutron and charged particle detector for low-energy reaction studies

NeutronSTARS (Neutron-Silicon Telescope Array for Reaction Studies) consists of 2.2-tons of gadolinium-doped liquid scintillator for neutron detection and large area silicon detectors for charged particle identification. This detector array is intended for low-energy-nuclear-reaction measurements that result in the emission of neutrons such as (n, xn) and fission. This paper describes the NeutronSTARS experimental setup, calibration, and the array’s response to neutral and charged particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of large-scale 6 Li-doped pulse-shape discriminating plastic scintillators

A 6 Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ -299-50, has been developed and produced at the kilogram-scale. A total of 44 bars of dimensions 5.5 cm x 5.5 cm x 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to 6 Li-doped liquid scintillators. Further, the scintillator EJ -299-50 shows good neutron detection capabilities with an effective efficiency for capture on 6 Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of a 6 LilnSe 2 thermal neutron detector into a CubeSat instrument

This paper describes the development of a preliminary compact and lightweight neutron detection system that uses the low power consuming CubeSat platform and will be especially effective for space-based applications. This is made possible using the novel 6 LiInSe 2 scintillator crystal and a silicon avalanche photodiode (Si-APD). The schematics of this instrument are presented as well as the response of the instrument to initial testing under alpha radiation. The entire system weighs 670 grams and requires 5 volts direct current at 3 watts.

36 MATERIALS SCIENCE↗

The 3He Supply Problem

One of the main uses for 3He is in gas proportional counters for neutron detection. Radiation portal monitors deployed for homeland security and non-proliferation use such detectors. Other uses of 3He are for research detectors, commercial instruments, well logging detectors, dilution refrigerators, for targets or cooling in nuclear research, and for basic research in condensed matter physics. The US supply of 3He comes almost entirely from the decay of tritium used in nuclear weapons by the US and Russia. A few other countries contribute a small amount to the world’s 3He supply. Due to the large increase in use of 3He for homeland security, the supply has dwindled, and can no longer meet the demand. This white paper reviews the problems of supply, utilization, and alternatives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of the NDA of HEU Oxide between the AWCC and the HPGe Detector

This paper compares the performance of the Active Well Coincidence Counter (AWCC) with the performance of high resolution gamma spectrometry using an HPGe detector to nondestructively assay highly enriched (HEU) oxide. Traditionally the AWCC was considered to be the more appropriate instrument for this measurement. Although the AWCC had a high degree of precision, the HPGe provided the more accurate measurement of this material. The AWCC determines mass of U-235 from the coincident pairs of neutron detections, or doubles rate. The HPGe determines the mass of both U-235 and U238, the enrichment, and the quantity of other radioisotopes. The Tl-208 gamma rays were used to verify the amount of attenuation for the HPGe analysis. Fifty-four cans of enriched U3O8 were shipped to the Y-12 National Security Complex from Los Alamos National Laboratory (LANL) under Scrap Declaration LANL-45. The declared values for net weight, mass of uranium, mass of U-235, and enrichment (percent mass of U-235 to total uranium) are shown in Table A-1. The masses of U-235 range from 104g to 2404g and the enrichment varies from 20% to 98%.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

DNDO Report: Developing a Photon Clutter Scaling Algorithm for Implementation into the NINESIM Tool

The Nuclear Inspection Node Event SIMulator (NINESIM) is a tool that is capable of modeling a node that monitors passing traffic for radiological and nuclear materials. This task requires the consideration of a number of factors. One such factor is clutter, or the level of traffic passing through a node. Clutter might affect the performance of radiation detectors due to attenuation or scattering that particles undergo as they move through the material. This paper discusses the results from MCNP simulations that were performed to determine in what scenarios clutter had a significant impact on detector performance, where the receiver operating characteristic (ROC) curve was used as the metric to evaluate detector performance. Clutter was found to have an insignificant impact on neutron detection, therefore, clutter may be ignored when modeling neutron detectors. However, there were a number of scenarios where clutter was found to affect the performance of photon detectors; the amount of traffic was found to be directly proportional to the effectiveness of photon detectors. The results of this work were then used to develop a photon clutter scaling algorithm that will be implemented into NINESIM. The Domestic Nuclear Detection Office, and possibly other agencies such as the Defense Threat Reduction Agency, will benefit from this work by eventually obtaining a tool that can enhance their ability in countering the illicit movement of radiological and nuclear materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Bayesian Radiation Source Localization

Locating illicit radiological sources using gamma ray or neutron detection is a key challenge for both homeland security and nuclear nonproliferation. Localization methods using an array of detectors or a sequence of observations in time and space must provide rapid results while accounting for a dynamic attenuating environment. In the presence of significant attenuation and scatter, more extensive numerical transport calculations in place of the standard analytical approximations may be required to achieve accurate results. Numerical adjoints based on deterministic transport codes provide relatively efficient detector response calculations needed to determine the most likely location of a true source. Probabilistic representations account for uncertainty in the source location resulting from uncertainties in detector responses, the approximations that are used, and the potential for nonunique solutions. A Bayesian approach improves on previous likelihood methods for source localization by allowing the incorporation of all available information to help constrain solutions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

New crystal structural families of lanthanide chloride alcohol/water complexes

The exploration of lanthanide chloride compounds as possible scintillation materials for gamma ray and neutron detection has led to the discovery of several new families of crystal structures with the general formula LnCl3(CH3OH)x(H2O)y. The specific crystal structure depends on the water/methanol content and lanthanide ion. The coordination of the light (large) lanthanides is the typical value of 8 and reduces to 7 for the heavier (small) lanthanides. The binding energy of water versus alcohol ligands is comparable, so that if water is present in the system, it is typically incorporated as a ligand in the crystal. In these crystals, the molecular adducts occur as monomers, dimers, and dichloro-bridged chains. These, in turn, form 3-D frameworks through H-bonds to the Cl atoms. Other distinct crystal structures are predicted, given the volume changes due to the lanthanide contraction, the water content of the crystal growth solutions, and the specific halide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A wearable sensor based on CLYC scintillators

We developed a wearable radiation sensor using Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous gamma-ray and neutron detection. The system includes two ø2.5×2.5 cm 3 crystals coupled to small, metal-body photomultiplier tubes. A custom, low-power electronics base digitizes the output signal at three time points and enables both pulse height and pulse shape discrimination of neutrons and gamma-rays. Data, including spectra, can be transferred via a wired or wireless connection. The total gamma-ray and neutron counts, anomaly detection metrics, and identified isotopes are displayed on a small screen on the device. Users may leave the system in unattended mode to collect long-dwell energy spectra. The prototype system has overall dimensions of 13×7.5×18 cm 3 and weight of 1.3 kg, not including the protective pouch, and runs on six AA alkaline batteries for 29 hours with a 1% wireless transmission duty cycle and 41 hours with the wireless turned off . In this paper, we summarize the system design and present characterization results from the detector modules. The energy resolution is about 6.5% full width at half maximum at 662 keV due to the small photomultiplier tube selected, and the linearity and pulse shape discrimination performance are very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Quick Overview of the Extended Feynman Project

The low natural background rates and the penetrating nature of neutron radiation makes neutron detection a good method for quantifying and accounting for large amounts of special nuclear material capable of neutron induced fission and fission chains. Fission is one of the few natural processes that produces time-correlated neutrons, the others are spallation-type processes (e.g. (n,Xn), cosmic induced background, etc) which have low but measurable rates in common terrestrial material. The high rates of most transuranic spontaneous fission sources of even a gram or less usually swamp any cosmic induced background rate but even Kilogram quantities of natural uranium produce neutrons only on the same order as that of the cosmic generated background flux. However the primary characteristic of special nuclear material is its ability to fission and to support fission chains through neutron induced fission. This means that neutrons produced from fission are not produced randomly singly but rather in time-correlated bursts. Almost from the beginning of the atomic age, the measurement of time-correlated neutrons has been used to detect and quantify fission and fission processes. Feynman himself proposed a method, the grandfather of what is used today, to compare correlation rates of neutron flux in a fixed time to that which would be expected of a random neutron source. The larger variance (broader distribution) as compared to a random distribution is a tell-tale sign of correlated production and commonly used as signature of fission and more importantly fission chains, the broader the distribution (and its departure from a random distribution) the higher the multiplication. Feynman’s original method was used to determine the criticality of the first reactor and other critical or near critical systems. We at LLNL have been developing this concept over the past decade and a half and have employed it for the detection and assessment of nuclear materials. Our method for doing this involved generating a theoretical prediction of what we might expect to see, given a neutron source (spontaneous fission with a nubar, or alpha-n) and a possibly multiplying material (Plutonium or Uranium) and comparing it to a measured result and deducing from this what it is we are measuring. We first developed these methods for portable (low efficiency) thermal neutron detectors that were used predominantly for emergency response situations and we have applied some of these techniques with thermal neutron detectors to arms control verification and authentication, for example verifying that there are multiplying quantities of plutonium in an unknown object. In recent years we have been exploring the use of fast neutrons using liquid scintillator cells with Pulse Shape Discrimination (PSD) and in this project we developing both the theory of fast particle production from fission and fission chains and the use of fast particle detection methods primarily for arms control verification and authentication, but for other uses. We have found that fast detection has many advantages, primarily because the speed of the detection (nanoseconds) preserves the original time scale of the particles produced by fission (and more importantly from induced fission) but also because the fast time scales allow for considering much shorter measurement times (binning) that greatly reduce the pollution of random correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution, vacuum-ultraviolet absorption spectrum of boron trifluoride

In the course of investigations of thermal neutron detection based on mixtures of {sup 10}BF{sub 3} with other gases, knowledge was required of the photoabsorption cross sections of {sup 10}BF{sub 3} for wavelengths between 135 and 205 nm. Large discrepancies in the values reported in existing literature led to the absolute measurements reported in this communication. The measurements were made at the SURF III Synchrotron Ultraviolet Radiation Facility at the National Institute of Standards and Technology. The measured absorption cross sections vary from 10{sup −20} cm{sup 2} at 135 nm to less than 10{sup −21} cm{sup 2} in the region from 165 to 205 nm. Three previously unreported absorption features with resolvable structure were found in the regions 135–145 nm, 150–165 nm, and 190–205 nm. Quantum mechanical calculations, using the TD-B3LYP/aug-cc-pVDZ variant of time-dependent density functional theory implemented in Gaussian 09, suggest that the observed absorption features arise from symmetry-changing adiabatic transitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of astrophysical S factors and electron screening potentials for d(d, n){sup 3}He reaction In ZrD{sub 2}, TiD{sub 2}, D{sub 2}O, and CD{sub 2} targets in the ultralow energy region using plasma accelerators

The paper is devoted to study electron screening effect influence on the rate of d(d, n){sup 3}He reaction in the ultralow deuteron collision energy range in the deuterated polyethylene (CD{sub 2}), frozen heavy water (D{sub 2}O) and deuterated metals (ZrD{sub 2} and TiD{sub 2}). The ZrD{sub 2} and TiD{sub 2} targets were fabricated via magnetron sputtering of titanium and zirconium in gas (deuterium) environment. The experiments have been carried out using high-current plasma pulsed accelerator with forming of inverse Z pinch (HCEIRAS, Russia) and pulsed Hall plasma accelerator (NPI at TPU, Russia). The detection of neutrons with energy of 2.5MeV from dd reaction was done with plastic scintillation spectrometers. As a result of the experiments the energy dependences of astrophysical S factor for the dd reaction in the deuteron collision energy range of 2-7 keV and the values of the electron screening potential U{sub e} of interacting deuterons have been measured for the indicated above target: U{sub e}(CD{sub 2}) Less-Than-Or-Slanted-Equal-To 40 eV; U{sub e}(D{sub 2}O) Less-Than-Or-Slanted-Equal-To 26 eV; U{sub e}(ZrD{sub 2}) = 157 {+-} 43 eV; U{sub e}(TiD{sub 2}) = 125{+-}34 eV. The value of astrophysical S factor, corresponding to the deuteron collision energy equal to zero, in the experiments with D{sub 2}O target is found: S{sub b}(0) = 58.6 {+-} 3.6 keV b. The paper compares our results with other available published experimental and calculated data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlated Neutron Emissions from 252 Cf

This paper presents new experimental results of correlated, prompt neutron emission from the spontaneous fission of 252 Cf. Specifically, we present correlated-neutron emission probabilities and average energies for two detected neutrons as a function of the angle between the two neutrons. Finally, experimental results are compared to several Monte Carlo models that include the number, energy, and angular distributions of prompt neutrons from fission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗