Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutrino detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Study of the Neutrino Magnetic Moment with the NOvA Near Detector

Predicted by the Standard Model as theoretical, massless particles, neutrinos have been the subject of many experiments since their first detection. It is now experimentally confirmed that neutrinos do have mass necessitating an extension to the Standard Model. Such an extension allows for other surprising neutrino properties, such as a neutrino magnetic moment, nuMM. While neutrinos are observed to be neutral and do not couple to photons at leading order, higher order expansion of the interaction allows for coupling to the photon to occur and gives rise to a nuMM through quantum loop effects. This is a useful property for studying the Dirac or Majorana nature of neutrinos, as the predicted value of the magnetic moment would differ. This talk focuses on an introduction to the nuMM as well as discusses the current status of work being done on NOvA utilizing the Near Detector to obtain an upper limit on the nuMM value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radio telescopes as the detectors of super-high-energy neutrinos

The registration of super high energy neutrinos is a very difficult and also very important problem that requires construction of detectors with large effective target masses. Askaryan pointed out the possibility of registering cascades in dense media by the Cherenkov radio emission of an excess of negative charges in the cascades which arose in interaction between high energy particles and the atoms of medium. The telescopes for cosmic high energy neutrino detection by radioemission of cascades induced underground, but whose development continues in the atmosphere were proposed by others. The effective target masses of such detectors could be approx. 10(exp 9) tons and more. The properties of Cherenkov radio emission of cascades and the properties of ice in the Antarctic Region make it possible to propose Radio Antarctic Muon and Neutrino Detection (RAMAND): antennas should be placed on the ice surface of approx. 10 sq km to search for radio signals for neutrino (muon) cascades of energy. It is evident from data given that the largest radio telescopes gives the opportunity for registration of the cascades induced by neutrinos with the energies E is greater than or = 10(exp 20) eV.

Dagkesamansky, R. D.↗

Systematic Uncertainties of the NOvA Neutrino Oscillation Analysis

NOvA is a two detector long-baseline neutrino oscillation experiment using Fermilab’s 700 kW NuMI muon neutrino beam. It studies the disappearance of muon (anti)neutrinos and the appearance of electron (anti)neutrinos in the beam over a distance of 810 km between the detectors. The observations can be used to constrain neutrino oscillation parameters: $\theta_{23}, \Delta m_{32}^2$ and $\delta_{CP}$ in the standard 3 active neutrinos paradigm. Although statistical uncertainties currently dominate in these measurements, understanding the major sources of systematic uncertainties and their correlations is vital for both the interpretation and precision of the results and also for further improvements of the analysis. This note presents details of the systematic uncertainties affecting NOvA's neutrino oscillation analysis results and how we evaluate them by generating systematically shifted predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reactor neutrino applications and coherent elastic neutrino nucleus scattering

Potential applications of neutrino detection to nuclear security have been discussed since the 1970s. Recent years have seen great progress in detector technologies based on inverse beta decay, with the demonstration of ton-scale surface-level detectors capable of high quality neutrino spectrum measurements. At the same time coherent elastic neutrino nucleus scattering has been experimentally confirmed in 2017 with neutrinos from stopped pion decay and there is a number of experiments aimed at seeing this reaction with reactor neutrinos. Here, the large cross section and threshold-less nature of this reaction make it plausible to consider it for applications to nuclear security and here, we present a first direct comparison of the two reaction modes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Macroscopic approach to the radar echo scatter from high-energy particle cascades

To probe the cosmic particle flux at the highest energies, large volumes of dense material like ice have to be monitored. This can be achieved by exploiting the radio signal. In this work, we provide a macroscopic model to predict the radar echo signatures found when a radio signal is reflected from a cosmic-ray or neutrino-induced particle cascade propagating in a dense medium like ice. Its macroscopic nature allows for an energy independent run-time, taking less than 10 s for simulating a single scatter event. As a first application, we discuss basic signal properties and simulate the expected signal for the T-576 beam-test experiment at the Stanford Linear Accelerator Center. Finally, we find good signal strength agreement with the only observed radar echo from a high-energy particle cascade to date.

79 ASTRONOMY AND ASTROPHYSICS↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

In this work, liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by γ interactions from 228 Th (2615 keV), 226 Ra (1764 keV), and 60 Co (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5±0.5 (syst.) ±0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double β -decay detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons

In this paper, we describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. We report a detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on flavor-diagonal non-standard neutrino interactions from Borexino Phase-II

The Borexino detector measures solar neutrino fluxes via neutrino-electron elastic scattering. Observed spectra are determined by the solar-$\nu_{e}$ survival probability $P_{ee}(E)$, and the chiral couplings of the neutrino and electron. Some theories of physics beyond the Standard Model postulate the existence of Non-Standard Interactions (NSI's) which modify the chiral couplings and $P_{ee}(E)$. In this paper, we search for such NSI's, in particularly neutral-current-like interactions that modify the $\nu_e - e$ and $\nu_\tau - e$ couplings, using Borexino Phase II data. Standard Solar Model predictions of the solar neutrino fluxes for both high- and low-metallicity assumptions are considered. No indication of new physics is found at the level of sensitivity of the detector and constraints on the parameters of the NSI's are placed. In addition, with the same dataset the value of $\sin^2\theta_W$ is obtained with a precision comparable to that achieved in reactor antineutrino experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic shower reconstruction and energy validation with Michel electrons and π 0 samples for the deep-learning-based analyses in MicroBooNE

This article presents the reconstruction of the electromagnetic activity from electrons and photons (showers) used in the MicroBooNE deep learning-based low energy electron search. The reconstruction algorithm uses a combination of traditional and deep learning-based techniques to estimate shower energies. We validate these predictions using two v μ -sourced data samples: charged/neutral current interactions with final state neutral pions and charged current interactions in which the muon stops and decays within the detector producing a Michel electron. Both the neutral pion sample and Michel electron sample demonstrate agreement between data and simulation. Finally, the absolute shower energy scale is shown to be consistent with the relevant physical constant of each sample: the neutral pion mass peak and the Michel energy cutoff.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for neutrino lines from dark matter annihilation and decay with IceCube

Dark matter particles in the Galactic Center and halo can annihilate or decay into a pair of neutrinos producing a monochromatic flux of neutrinos. The spectral feature of this signal is unique and it is not expected from any astrophysical production mechanism. Its observation would constitute a dark matter smoking gun signal. Here we performed the first dedicated search with a neutrino telescope for such signal, by looking at both the angular and energy information of the neutrino events. To this end, a total of five years of IceCube’s DeepCore data has been used to test dark matter masses ranging from 10 GeV to 40 TeV. No significant neutrino excess was found and upper limits on the annihilation cross section, as well as lower limits on the dark matter lifetime, were set. The limits reached are of the order of 10 -24 cm 3 /s for an annihilation and up to 10 27 s for decaying dark matter. Using the same data sample we also derive limits for dark matter annihilation or decay into a pair of Standard Model charged particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement Of The Total Cross-Section Of Muon Neutrino Charged-Current Coherent Pion Production in NOvA Near Detector

Charged Current (CC) coherent neutrino-nucleus pion production is characterized by small momentum transferred to the nucleus, which is left in its ground state. Despite the relatively large uncertainties on the production cross-section, coherent production of mesons by neutrinos represents an important process, as it can shed light on the structure of the weak current and can also constitute a potential source of background for modern neutrino oscillation experiments and searches for Beyond Standard Model (BSM) physics. This Ph.D. thesis presents a new measurement of CC coherent pion production in the NOvA near detector at the Fermi National Accelerator Laboratory (Fermilab). The analysis is based on the use of both particle identification and kinematic selection criteria based on Convolutional Neural Networks (CNN) to achieve a selection purity of 60%. Given the energy range 1-5 GeV accessible with the available NOvA exposure in the NuMI beam, the results will also be relevant for f uture neutrino experiments like the Deep Underground Neutrino Experiment (DUNE).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗