Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

International Space Agency CIO Forum Industrial Control System (ICS) and Cyber

This briefing covers Industrial Control System (ICS) best practices for enhancing cyber protection. The briefing provides a very high-level overview of best practices currently being pursued by NASA as well as by other US government agencies such as NIST and DHS ICS-CERT. All information presented in this slide deck is publicly available and no sensitive information is provided in these slides. These slides will be used to generate discussion around best practices within the international community in the area of ICS cyber protections.

Powell, Robert↗

JPSS-1 VIIRS Version 2 At-Launch Relative Spectral Response Characterization and Performance

The relative spectral response (RSR) characterization of the JPSS-1 VIIRS spectral bands has achieved at launch status in the VIIRS Data Analysis Working Group February 2016 Version 2 RSR release. The Version 2 release improves upon the June 2015 Version 1 release by including December 2014 NIST TSIRCUS spectral measurements of VIIRS VisNIR bands in the analysis plus correcting CO2 influence on the band M13 RSR. The T-SIRCUS based characterization is merged with the summer 2014 SpMA based characterization of VisNIR bands (Version 1 release) to yield a fused RSR for these bands, combining the strengths of the T-SIRCUS and the SpMA measurement systems. The M13 RSR is updated by applying a model-based correction to mitigate CO2 attenuation of the SpMA source signal that occurred during M13 spectral measurements. The Version 2 release carries forward the Version 1 RSR for those bands that were not updated (M8-M12, M14-M16AB, I3-I5, DNBMGS). The Version 2 release includes band average (overall detectors and subsamples) RSR plus supporting RSR for each detector and subsample. The at-launch band average RSR have been used to populate Look-Up Tables supporting the sensor data record and environmental data record at-launch science products. Spectral performance metrics show that JPSS-1VIIRS RSR are compliant on specifications with a few minor exceptions. The Version 2 release, which replaces the Version 1 release, is currently available on the password-protected NASA JPSS-1 eRooms under EAR99 control.

Chris Moeller↗

Toward Large FOV High-Resolution X-Ray Imaging Spectrometer: Microwave Multiplexed Readout of 32 TES Microcalorimeters

We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.

Yoon, Wonsik↗

NASA's EOSDIS, Trust and Certification

NASA's Earth Observing System Data and Information System (EOSDIS) has been in operation since August 1994, managing most of NASA's Earth science data from satellites, airborne sensors, filed campaigns and other activities. Having been designated by the Federal Government as a project responsible for production, archiving and distribution of these data through its Distributed Active Archive Centers (DAACs), the Earth Science Data and Information System Project (ESDIS) is responsible for EOSDIS, and is legally bound by the Office of Management and Budgets circular A-130, the Federal Records Act. It must follow the regulations of the National Institute of Standards and Technologies (NIST) and National Archive and Records Administration (NARA). It must also follow the NASA Procedural Requirement 7120.5 (NASA Space Flight Program and Project Management). All these ensure that the data centers managed by ESDIS are trustworthy from the point of view of efficient and effective operations as well as preservation of valuable data from NASA's missions. Additional factors contributing to this trust are an extensive set of internal and external reviews throughout the history of EOSDIS starting in the early 1990s. Many of these reviews have involved external groups of scientific and technological experts. Also, independent annual surveys of user satisfaction that measure and publish the American Customer Satisfaction Index (ACSI), where EOSDIS has scored consistently high marks since 2004, provide an additional measure of trustworthiness. In addition, through an effort initiated in 2012 at the request of NASA HQ, the ESDIS Project and 10 of 12 DAACs have been certified by the International Council for Science (ICSU) World Data System (WDS) and are members of the ICSUWDS. This presentation addresses questions such as pros and cons of the certification process, key outcomes and next steps regarding certification. Recently, the ICSUWDS and Data Seal of Approval (DSA) organizations merged their Core Trustworthy Data Repositories Requirements and require that members be recertified every three years. Given the rigor with which NASA manages the ESDIS Project and the DAACs, the recertification through WDSDSA, while involving some additional work, is a relatively simple process.

Certification↗

Calibrated Noise Measurements with Induced Receiver Gain Fluctuations

The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory in science and engineering. These limitations were encountered when modeling the performance of radiometer calibration architectures and algorithms in the presence of non stationary receiver fluctuations. Analyses of measured signals have traditionally been limited to a single measurement series. Whereas in a radiometer that samples a set of noise references, the data collection can be treated as an ensemble set of measurements of the receiver state. Noise Assisted Data Analysis is a growing field of study with significant potential for aiding the understanding and modeling of non stationary processes. Typically, NADA entails adding noise to a signal to produce an ensemble set on which statistical analysis is performed. Alternatively as in radiometric measurements, mixing a signal with calibrated noise provides, through the calibration process, the means to detect deviations from the stationary assumption and thereby a measurement tool to characterize the signal's non stationary properties. Data sets comprised of calibrated noise measurements have been limited to those collected with naturally occurring fluctuations in the radiometer receiver. To examine the application of NADA using calibrated noise, a Receiver Gain Modulation Circuit (RGMC) was designed and built to modulate the gain of a radiometer receiver using an external signal. In 2010, an RGMC was installed and operated at the National Institute of Standards and Techniques (NIST) using their Noise Figure Radiometer (NFRad) and national standard noise references. The data collected is the first known set of calibrated noise measurements from a receiver with an externally modulated gain. As an initial step, sinusoidal and step-function signals were used to modulate the receiver gain, to evaluate the circuit characteristics and to study the performance of a variety of calibration algorithms. The receiver noise temperature and time-bandwidth product of the NFRad are calculated from the data. Statistical analysis using temporal-dependent calibration algorithms reveals that the natural occurring fluctuations in the receiver are stationary over long intervals (100s of seconds); however the receiver exhibits local non stationarity over the interval over which one set of reference measurements are collected. A variety of calibration algorithms have been applied to the data to assess algorithms' performance with the gain fluctuation signals. This presentation will describe the RGMC, experiment design and a comparative analysis of calibration algorithms.

Racette, Paul↗

Optical Component Performance for the Ocean Radiometer for Carbon Assessment (ORCA)

The Ocean Radiometer for Carbon Assessment (ORCA) is a new design for the next generation remote sensing of ocean biology and biogeochemistry. ORCA is configured to meet all the measurement requirements of the Decadal Survey Aerosol, Cloud, and Ecology (ACE), the Ocean Ecosystem (OES) radiometer and the Pro-ACE climate data continuity mission (PACE). Under the auspices of a 2007 grant from NASA Research Opportunity in Space and Earth Science (ROSES) and the Instrument Incubator Program (IIP), a team at the Goddard Space Flight Center (GSFC) has been working on a functional prototype with flight-like fore and aft optics and scan mechanisms. As part of the development efforts to bring ORCA closer to a flight configuration and in order to reduce cost, we have conducted component-level optical testing using standard spectrophotometers and system-level characterizations using non-flight commercial off-the-shelf (COTS) focal plane array detectors. Although these arrays would not be able to handle flight data rates, they are adequate for optical alignment and performance testing. The purpose of this presentation is to describe the results of this testing performed at GSFC and the National Institute of Standards and Technology (NIST) at the component and system level. Specifically, we show results for ORCA's spectral calibration ranging from the near UV, visible, and near-infrared spectral region.

Quijada, Manuel A.↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

In-Flight Calibration and Performance of the OSIRIS-REx Visible and IR Spectrometer (OVIRS)

Performance of the Origins, Spectral Interpretation, Resource Identification, Security-Regolith Explorer (OSIRIS-REx) Visible and InfraRed Spectrometer (OVIRS) instrument was validated, showing that it met all science requirements during extensive thermal vacuum ground testing. Preliminary instrument radiometric calibration coefficients and wavelength mapping were also determined before instrument delivery and launch using NIST-traceable sources. One year after launch, Earth flyby data were used to refine the wavelength map by comparing OVIRS spectra with atmospheric models. Near-simultaneous data from other Earth-orbiting satellites were used to cross-calibrate the OVIRS absolute radiometric response, particularly at visible wavelengths. Trending data from internal calibration sources and the Sun show that instrument radiometric performance has been stable to better than 1% in the 18 months since launch.

spectrometer↗

The Effects of High-Temperature Fractional Crystallization on Calcium Isotopic Composition

We report Ca isotope fractionation among a co-genetic suite of samples from the Mauritanian Guelb el Azib ultramafic-mafic-anorthosite complex (GAC), which represents the fractional crystallization sequence of an igneous magma chamber. We investigate how the composition of an evolving crystallizing liquid and the resultant mineralogy of co-crystallizing assemblages affects inter-phase Ca isotope fractionation. Because the GAC is an Archean metamorphosed complex, we first investigate the resistance of the Ca isotope signature to secondary hydrothermal alteration and to metamorphism. While we cannot conclude here that Ca isotopes are undisturbed at the mineral scale, we show that they are preserved at the bulk rock scale. This is adequate for our study where several samples are almost monomineralic at the bulk scale level. The δ(exp 44/40)Ca (relative to NIST standard SRM 915a) of GAC layers range from −1.53 to 1.61‰, with the earliest-formed ultramafic cumulate layer being isotopically heaviest and the later, more felsic layers being isotopically lighter. For the first time, we show that plagioclase is much more enriched in light Ca isotopes compared to olivine and (Ca-) pyroxene. Monte Carlo simulations suggest that Ca isotopes are fractionated among co-existing silicate minerals during fractional crystallization, possibly in relation with the residual liquid composition. In qualitative agreement with computational models based on first principles lattice dynamics, we observe that Ca isotope fractionation is mineralogically controlled and importantly, that the degree of fractionation can vary according to the CaO composition of the residual liquid. While previous studies have aimed to understand partial melting as a source of Ca isotope fractionation, our results suggest that fractional crystallization is also a source of Ca isotope variability among co-genetic samples.

Maria C. Valdes↗

Detector Based Calibration of a Portable Imaging Spectrometer for CLARREO Pathfinder Mission

The Climate Absolute Refractivity and Reflectance Observatory (CLARREO) Pathfinder (CPF) mission is being developed to demonstrate SI-traceable retrievals of reflectance at unprecedented accuracies for global satellite observations. An Independent Calibration of the CPF sensor using the Goddard Laser for Absolute Measurement of Radiance (GLAMR) is planned to allow validation of CPF accuracies. GLAMR is a detector-based calibration system relies on a set of NIST-calibrated transfer radiometers to assess the spectral radiance from the GLAMR sphere source to better than 0.3 % (k=2). The current work describes the calibration of the Solar, Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS) that was originally developed as a calibration demonstration system for the CLARREO mission and is now being used to assess the independent calibration being developed for CPF. The methodology for the radiometric calibration of SOLARIS is presented as well as results from the GLAMR-based calibration of SOLARIS. The portability of SOLARIS makes it capable of collecting field measurements of earth scenes and direct solar and lunar irradiance similar to those expected during the on-orbit operation of the CPF sensor. Results of SOLARIS field measurements are presented. The use of SOLARIS in this effort also allows the testing protocols for GLAMR to be improved and the field measurements by SOLARIS build confidence in the error budget for GLAMR calibrations. Results are compared to accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

Aytac, Yigit↗

Updates to the Absolute Radiometric Accuracy of the AIRS on Aqua

The Atmospheric Infrared Sounder (AIRS) on the EOS Aqua Spacecraft was launched on May 4, 2002. The AIRS was designed to measure small changes in the global hydro-thermodynamic cycle and has demonstrated exceptional radiometric and spectral stability and accuracy in-orbit. This accuracy is achieved by transferring the calibration from a Large Area Blackbody (LABB) to the On-Board Calibrator (OBC) blackbody during preflight testing. The LABB theoretical emissivity is in excess of 0.9999 and temperature uncertainty is less than 50 mK. The LABB emitted radiance is NIST traceable through thermistors located on the internal surfaces. The AIRS also provides a full aperture space view every scan for offset calibration. AIRS nonlinearity and polarization calibration coefficients were based on pre-flight testing and have been amongst the highest uncertainty sources in the calibration. A recent method using on-board space view data has reduced the uncertainty of the polarization coefficients and use of separate A side and B side data from preflight testing has reduced the uncertainty of the nonlinearity estimates. An update to the system radiometric uncertainty is made based on the new data and is presented in this paper.

Weiler, Margaret H.↗

Pragmatic Stress Prediction on Additively Manufactured Coupons

Prediction of residual stresses from process parameters for additively manufactured large metal parts is computationally expensive. NASA is currently developing meter-scale parts with direct energy deposition. Practically, the predictive computational methods need to efficiently scale-up to meter-scale parts. Coupled thermal-mechanical multi-physics simulations have been developed with the pragmatic method using ABAQUS, COMSOL Multiphysics, ALE3D software. The residual stresses are a result of the manufacturing process which creates thermal cycling of the build layers. The pragmatic method uses lumped thermal layers for stress predictions to reduce computational costs. The stress predictions as well as deformations of the different codes are compared with each other and with ANSYS Additive using identical material models, boundary and initial conditions. The codes were used to simulate three different geometries: a thin wall, hollow cylinder and twin-cantilever part. The coupon parts were then manufactured with Inconel-625. The residual stresses in these parts were measured using X-ray diffraction as well as neutron beam diffraction at NIST. The stress measurements for the two technologies are compared. The pragmatic stress prediction method enabled predictions of the multi-centimeter scale parts using desktop computer workstations in only a few hours for each coupon. The results of the simulated stress predictions compared favorably with the measured stresses even though thermally lumped layers were employed. Finally, a two-meter scale nozzle was simulated using ANSYS Additive. The simulations were used to examine the build orientation trade-space with respect to resulting geometric deformation. The predicted deformations were compared to measurements of an actual subscale part manufactured with direct energy deposition.

Additive Manufacturing↗

On-Orbit Calibration and Performance Assessments of Terra and Aqua Modis Thermal Emissive Bands

Terra and Aqua MODIS have successfully operated for more than 20 and 18 years, respectively, and far exceeded their designed lifetimes of 6 years. MODIS has 36 spectral bands, among which 16 are the thermal emissive bands (TEB) covering a wavelength range from 3.75 to 14.24 μm. Observations from the MODIS TEB have been used to generate a number of data products, such as surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties. To a large extent, the quality of the MODIS L1B radiance product has been maintained through the entirety of each mission via extensive on-orbit calibration and validation efforts. MODIS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with its temperature measurements traceable to the NIST standard. We provide an overview of the MODIS instrument operations, key TEB calibration activities, and algorithms used in the latest L1B data Collection 6.1 (C6.1) and describe the TEB on-orbit performance for both Terra and Aqua MODIS. The TEB gain trends have been stable to within 5% over the Terra mission after 2003 under the same electronic configuration, except for bands 27 to 30, and within 3% over the Aqua mission. The Terra MODIS optical crosstalk correction implemented right after launch has been very effective in removing the ghost images in its photoconductive detector bands 32 to 36. Starting from C6.1, an electronic crosstalk correction algorithm has also been applied to the Terra MODIS photovoltaic detector long-wave infrared bands 27 to 30. The noise characterization performance remains stable with most TEB detectors continuously meeting their design requirements. A gradual loss of the Aqua MODIS radiative cooler margin reached its maximum in 2013 and has been slowly recovering since then. On-orbit changes in TEB response versus scan angle are extremely small based on pitch maneuver observations and assessments using vicarious approaches. The remaining challenges in TEB calibration and proposed improvements for the upcoming data collection with L1B data production and reprocessing are discussed.

Terra↗

Radiometric Calibration of A Non-Imaging Airborne Spectrometer To Measure the Greenland Ice Sheet Surface

Methods to radiometrically calibrate a non-imaging airborne visible-to-shortwave infrared (VSWIR) spectrometer to measure the Greenland ice sheet surface are presented. Airborne VSWIR measurement performance for bright Greenland ice and dark bare rock/soil targets is compared against the MODerate resolution atmospheric TRANsmission (MODTRAN ® ) radiative transfer code (version 6.0), and a coincident Landsat 8 Operational Land Imager (OLI) acquisition on 29 July 2015 during an in-flight radiometric calibration experiment. Airborne remote sensing flights were carried out in northwestern Greenland in preparation for the Ice, Cloud, and land Elevation Satellite 2 (ICESat-2) laser altimeter mission. A total of nine science flights were conducted over the Greenland ice sheet, sea ice, and open-ocean water. The campaign's primary purpose was to correlate green laser pulse penetration into snow and ice with spectroscopic-derived surface properties. An experimental airborne instrument configuration that included a nadir-viewing (looking downward at the surface) non-imaging Analytical Spectral Devices (ASD) Inc. spectrometer that measured upwelling VSWIR (0.35 to 2.5 µm) spectral radiance (Wm −2 sr −1 µm −1 ) in the two-color Slope Imaging Multi-polarization Photon-Counting Lidar's (SIMPL) ground instantaneous field of view, and a zenith-viewing (looking upward at the sky) ASD spectrometer that measured VSWIR spectral irradiance (W m −2 nm −1 ) was flown. National Institute of Standards and Technology (NIST) traceable radiometric calibration procedures for laboratory, in-flight, and field environments are described in detail to achieve a targeted VSWIR measurement requirement of within 5 % to support calibration/validation efforts and remote sensing algorithm development. Our MODTRAN predictions for the 29 July flight line over dark and bright targets indicate that the airborne nadir-viewing spectrometer spectral radiance measurement uncertainty was between 0.6 % and 4.7 % for VSWIR wavelengths (0.4 to 2.0 µm) with atmospheric transmittance greater than 80 %. MODTRAN predictions for Landsat 8 OLI relative spectral response functions suggest that OLI is measuring 6 % to 16 % more top-of-atmosphere (TOA) spectral radiance from the Greenland ice sheet surface than was predicted using apparent reflectance spectra from the nadir-viewing spectrometer. While more investigation is required to convert airborne VSWIR spectral radiance into atmospherically corrected airborne surface reflectance, it is expected that airborne science flight data products will contribute to spectroscopic determination of Greenland ice sheet surface optical properties to improve understanding of their potential influence on ICESat-2 measurements.

Christopher J. Crawford↗

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗

Pragmatic Stress Prediction on Additively Manufactured Coupons

Prediction of residual stresses from process parameters for additively manufactured large metal parts is computationally expensive. NASA is currently developing meter-scale parts with direct energy deposition. Practically, the predictive computational methods need to efficiently scale-up to meter-scale parts. Coupled thermal-mechanical multi-physics simulations have been developed with the pragmatic method using ABAQUS, COMSOL Multiphysics, ALE3D software. The residual stresses are a result of the manufacturing process which creates thermal cycling of the build layers. The pragmatic method uses lumped thermal layers for stress predictions to reduce computational costs. The stress predictions as well as deformations of the different codes are compared with each other and with ANSYS Additive using identical material models, boundary and initial conditions. The codes were used to simulate three different geometries: a thin wall, hollow cylinder and twin-cantilever part. The coupon parts were then manufactured with Inconel-625. The residual stresses in these parts were measured using X-ray diffraction as well as neutron beam diffraction at NIST. The stress measurements for the two technologies are compared. The pragmatic stress prediction method enabled predictions of the multi-centimeter scale parts using desktop computer workstations in only a few hours for each coupon. The results of the simulated stress predictions compared favorably with the measured stresses even though thermally lumped layers were employed. Finally, a two-meter scale nozzle was simulated using ANSYS Additive. The simulations were used to examine the build orientation trade-space with respect to resulting geometric deformation. The predicted deformations were compared to measurements of an actual subscale part manufactured with direct energy deposition.

pragmatic method↗

Characterization of Bidirectional Transmissive and Reflective Properties of Black Silicon

This paper describes the initial work of characterizing the transmissive and reflective properties of black silicon diffusers. The diffusers were fabricated from a 100 mm diameter black silicon sample at NASA’s Goddard Space Flight Center (GSFC). The directional hemispherical reflectance from 250 nm to 2500 nm and BRDF/BTDF measurements at 632.8 nm, 1064 nm, and 1550 nm were measured using the GSFC Diffuser Calibration Laboratory’s (DCL) spectrophotometer and optical scatterometer. The diffusers exhibit a low level of specular reflection up to ~1100 nm with no evidence of retroscatter. The measurements are traceable to those made at the National Institute of Standards and Technology (NIST).

Bidirectional Reflectance Distribution Function↗

NASA’s Bio-inspired Broadband Acoustic Absorber: Experiences at the 2021 FedTech Startup Studio

Motivated by the need to reduce aircraft engine noise, NASA’s Bio-inspired Broadband Acoustic Absorber (“Bioliner”) is patented technology that can be developed into multifunctional structures that can absorb sound and might also transfer heat and/or carry a load. Bioliner was one of 12 technologies from federal and university labs that were selected for the FedTech Startup Studio 2021:1 National Aeronautics and Space Administration (NASA),2,3 National Institute of Standards and Technology (NIST),4 National Nuclear Security Administration (NNSA),5 and Northeastern University.6 From August to December 2021, FedTech coached teams of entrepreneurs who explored the commercial potential of the bioliner by performing customer discovery interviews. Results of that investigation supported the claim that the bioliner might have broad commercial potential, beyond aerospace use

acoustic absorber, noise, liner↗