Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NCSP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Update on the Benchmark Analysis of the Jupiter Experiments: Plutonium Moderated by Lead

The Jupiter experiment was a series of measurements in the summer of 2017 to analyze the effects of voids in lead moderated plutonium assemblies. This experiment was part of a larger campaign that took place at the National Criticality Experiments Research Center (NCERC) in collaboration with the Japan Atomic Energy Agency (JAEA) that also investigated assemblies with differing uranium enrichments. The purpose for this campaign was to provide data useful for a potential lead-bismuth cooled accelerator driven system. This data is needed due to the low number of benchmarks involving lead. Given the wide use of lead for shielding in addition to new reactor designs, there is a need for further benchmarking that this experiment could help fulfill. In addition, adding more benchmarks to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) is helpful for further validation of simulation methods used for criticality safety. This summary is an update on the current progress of this analysis, and all results shown are preliminary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulated Energy Response in a Multiplicity Detector

Neutron multiplicity analysis is used for many applications, including nonproliferation and criticality safety. Multiplicity detectors have advantages over total neutron counting as they provide the ability to assess both multiplication and mass in fissionable material. In addition, multiplicity detectors can generate real-time information, e.g., dose estimation. The ability to evaluate the detector efficiency in each application is of primary importance in producing meaningful analyses. Multiplicity detectors usually house 3 He tubes within a polyethylene moderator. If the tubes are located behind different thickness of polyethylene, they will have different energy responses. This paper assesses 3 He tube efficiency as a function of neutron energy for a specific multiplicity detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical Unresolved Region Integral Experiment Execution

Integral Experiments are a key aspect of validating nuclear data behavior and simulation capabilities. Further, integral experiments are the earliest form of validation of equations and codes. They have been used extensively since the 1940s. Today, simulation and predictive capabilities have improved greatly from 75 years ago, but nonetheless, integral experiments are still needed. As simulation capabilities improve, their uncertainties get much smaller. The current focus of many new experiments is understanding the intermediate energy range. The intermediate energy range does not have a wide application space and it can be challenging to design experiments that are sensitive to neutron energies in this region. The Zeus experiments evaluated highly enriched uranium (HEU) in the intermediate energy region. Building on the success and knowledge gained from the Zeus experiments, the Critical Unresolved Region Integral Experiment (CURIE) experiments were designed to evaluate HEU in the narrower unresolved resonance region (URR). These experiments were executed during June and July 2020 at the National Criticality Experiments Research Center (NCERC). The National Criticality Experiments Research Center (NCERC), operated by Los Alamos National Laboratory, is the only general purpose critical experiments facility in the United States of America. NCERC regularly designs and executes critical experiments and other measurements useful to a wide variety of fields including nuclear criticality safety, commercial nuclear energy, nonproliferation, and nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments at Sandia to Measure the Effect of Temperature on Critical Systems

Estimation of the uncertainty in a critical experiment attributable to uncertainties in the measured experiment temperature is done by calculating the variation of the eigenvalue of a benchmark configuration as a function of temperature. In the low-enriched water-moderated critical experiments performed at Sandia, this is done by 1) estimating the effects of changing the water temperature while holding the UO 2 fuel temperature constant, 2) estimating the effects of changing the UO 2 temperature while holding the water temperature constant, and 3) combining the two results. This assumes that the two effects are separable. The results of such an analysis are nonintuitive and need experimental verification. Critical experiments are being planned at Sandia National Laboratories (Sandia) to measure the effect of temperature on critical systems and will serve to test the methods used in estimating the temperature effects in critical experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subcritical Multiplication with a Fixed Source

In a subcritical, multiplying medium, the system multiplication describes the expected total number of neutrons created by a single source neutron. Subcriticality plays a large role in criticality safety and thus it is vital for the subcritical multiplication factor be accurate, especially as a system approaches criticality. This work examines the accuracy of calculating the system multiplication using the MCNP6.2 ® k-eigenvalue power iteration (KCODE) method when a fixed-point source is present in a multiplying medium, for near critical systems. This work compares the standard approach for calculating system multiplication, using the fixed-source calculational approach, to a new, single k-eigenvalue power iteration approach that incorporates a fixed-source component and a fission-source component into a single calculation. For the remainder of this paper, some theoretical background and numerical results for an approximate k eigenvalue approach, an accurate fixed-source approach and a new and more accurate k-eigenvalue approach to computing system multiplication are provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of MCNP Critical Benchmark Models of PU-MET-FAST-016

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The repository is the combined effort of the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The initial set of benchmark models in the repository are derived from the Whisper Suite provided with MCNP6.2 and are evaluated against the benchmark experiments described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with PU-MET-FAST-016, “Flooded 3X3X3 Arrays of 3-kg Plutonium (Pu) Metal Cylinders – Phase I”. In this critical experiment, twenty-seven 3-kg Pu metal cylinders with a height of 46.33 ± 0.15 mm and diameter of 65.25 ± 0.05 mm were arranged in a cubic array. The Pu cylinders were sealed in aluminum cans, and three cans were placed in each of nine perforated aluminum sleeves, as shown in Fig. 1. The nine sleeves were supported by an aluminum frame that allowed for control of the lateral spacing of the cylinders, both in the X and Y directions. The benchmark experiment measured thirteen configurations. Of these configurations, six were modeled using MCNP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sandia 7uPCX Critical Experiments Exploring the Effects of Fuel-to-Water Ratio Variations

The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The LEUCOMP-THERM-078 and LEU-COMP-THERM-080 evaluations from the handbook provide similar cases for reference. The set of experiments described here were performed using the Seven Percent Critical Experiment (7uPCX) fuel to measure the effects of decreasing the fuel-to-water volume ratio on the critical array size. This was accomplished by using fuel loading patterns to effectively increase the pitch of the fuel arrays in the assembly. The fuel rod pitch variations provided assembly configurations that ranged from strongly undermoderated to slightly overmoderated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity Calculations for Systems with Polyethylene Reflector Materials Using CLUTCH

The SCALE 6.2.4 code package contains four sequences for calculating $k_{eff}$ sensitivity coefficients. Two of these sequences use deterministic transport solvers: a one-dimensional (1D) capability based on XSDRN, and a two-dimensional (2D) capability based on NEWT. These sequences are restricted to the multigroup (MG) treatment of neutron energy. The three-dimensional (3D) sequences use the KENO V.a or KENO-VI Monte Carlo transport codes and can be used to calculate sensitivity coefficients with either MG or continuous-energy (CE) transport. The 3D sensitivities are ultimately reported in an MG structure, regardless of the method used in the transport calculations. If desired, the sensitivity coefficients can be reported with very fine energy resolution from a CE calculation, but they are calculated only in the MG library structure in the MG mode. CE TSUNAMI methods are available in SCALE starting in SCALE version 6.2. Sensitivity coefficients were generated using the 3D sequences as part of the generation of the SCALE 6.2.2 Validation Report; difficulties encountered when using the CLUTCH method for thick, fissionable-material reflectors were discussed and investigated as documented in a previous paper. This paper discusses the difficulties encountered in generating accurate sensitivity coefficients using the CLUTCH technique for polyethylene reflectors for two fast spectrum benchmarks. Direct perturbation (DP) calculations were performed to confirm the accuracy of the total sensitivity coefficient for important isotopes with large sensitivities in the system. Discrepancies were detected for CLUTCH-calculated sensitivity coefficients in the reflector of a critical experiment with a radial polyethylene reflector. A simple polyethylene-reflected plutonium sphere was then used to further investigate the discrepancy. Calculations performed using the iterated fission probability (IFP) method generated accurate sensitivity coefficients in both cases. The results of this study emphasize the need to confirm CLUTCH sensitivity results with DP calculations. IFP calculations are generally less efficient but more reliable than CLUTCH calculations. Improvements to the CLUTCH methodology that retain the greater efficiency but address identified difficulties are therefore potentially useful to analysts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovery of AMPX Thermal Scattering Law Processing Issue for Solid Moderators

The 2020 edition of The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook includes a newly produced plastic-moderated evaluation, identified as PU-MET-MIXED-002 and referred to as PMM002. The 2021 edition should include another new plastic-moderated experiment, HEU-MET-THERM-004, referred to as HMT-004. These evaluations are of particular interest, as PMM-002 is moderated with polyethylene, and HMT-004 is moderated with polymethyl methacrylate (Lucite), allowing for investigation of the differences in the thermal scattering laws (TSLs) available for these materials. ENDF/B-VIII.0 includes newly produced data for 1 H-based scattering materials, including Lucite and yttrium hydride. Other available 1 H TSLs include polyethylene, light water, zirconium hydride. The unbound 1 H (free-gas) cross sections were also used. ENDF/B-VIII.0 also includes revisions made to the ENDF/B-VII.1 light water and polyethylene evaluations. Zirconium hydride was unchanged from ENDF/B-VII.1. As of this writing, there are no benchmarks included in the Verified, Archived Library of Inputs and Data (VALID) that are primarily moderated with any solid moderator, so validation that includes the PMM-002 and HMT-004 evaluations would expand the coverage to two new moderators. A study was undertaken at Oak Ridge National Laboratory with two purposes: to provide validation data based on systems that are primarily moderated with polyethylene and Lucite, and to demonstrate the reactivity changes that can result from use of different 1 H TSLs in these plastic-moderated systems. The first objective was mainly to test data and code for SCALE and AMPX, whereas the second objective was to provide useful data for practitioners on the potential variability of predicted $k_{eff}$ based on TSL changes. The use of an exactly correct TSL is often not possible given the materials involved (e.g., lubricants), but this study was intended to provide some indication of the magnitude of the changes among similar materials that can manifest through application of different TSLs in hydrogenous systems over a range of different neutron energy spectra. Unfortunately, the nominal $k_{eff}$ results exposed deviations between SCALE and Monte Carlo N-Particle (MCNP). Some of the results using different TSLs were also unexpected and difficult to explain. An investigation revealed a processing issue in AMPX that was caused by an ambiguous description of the data for incoherent elastic scattering in the ENDF manual. This issue is discussed in detail in a SCALE User Notification, and it affects some solid moderators, but it does not apply to 1 H bound in water. This issue highlights the importance of validating all TSLs used in safety analysis calculations. The remainder of this paper provides a more detailed examination of the results that triggered the investigation and a summary of the findings of that investigation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hierarchical Data Format for Nuclear Data Sensitivities

The SCALE code system includes capabilities for sensitivity and uncertainty (S/U) analysis as part of its TSUNAMI code suite. The sensitivity of a quantity of interest (for example, an application’s $k_{eff}$) to nuclear data is stored as a profile in a text-based file, which is known as a sensitivity data file (SDF). The sensitivity profile can be used to calculate uncertainties, correlation coefficients, and similarity indices. One of the goals of the present work was to seek general performance improvements in the TSUNAMI code suite, starting with the TSUNAMI-IP code for calculating similarity indices. Through profiling, it was found that reading the text-based sensitivity files was a performance bottleneck in the TSUNAMI-IP code. In a typical TSUNAMI-IP calculation, an application might be compared to thousands of benchmarks, thus requiring the reading of thousands of SDFs. Reading of binary-based data is generally faster than reading text-based data. Hierarchical Data Format 5 (HDF5) is a binary-based format that also benefits from being portable, and it can be inspected with nonproprietary tools. This paper describes an HDF5-based file format that has been introduced for SDFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of ISO and ANSI/ANS Nuclear Criticality Safety Standards

This paper provides a high-level comparison between the international and domestic Nuclear Criticality Safety (NCS) standards, as requested by members of the Nuclear Criticality Safety Division. Currently, there are 18 enacted American National Standards Institute (ANSI)/American National Standards (ANS) and 1 ANSI/ANS standard in progress. There are 11 NCS standards from the International Organization for Standardization (ISO), Technical Committee 85 (TC85) on Nuclear Energy, Subcommittee 5 (SC5) on Nuclear Fuel Cycle, Working Group 8 (WG8). There are NCS standard revisions in progress for both standards organizations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Thermal Neutron Scattering Cross Sections for CaH 2

Solid metal hydrides have long been considered viable moderators for nuclear reactor designs due to their moderating ratios, hydrogen densities, high dissociation temperatures, and mechanical properties. CaH 2 is an orthorhombic saline-hydride that has recently been investigated and shows promise for use as a moderator in microreactors. At present, there is no Thermal Scatting Law (TSL) evaluation for CaH 2 in the ENDF/B-VIII.0 database. An evaluation does exist in the JEFF-3.3 database, performed by Serot, however it was limited by the implemented methods and thus both drastically over-predicts the incoherent elastic contribution and completely ignores the coherent elastic contribution to scattering from the metal ions. The thermal neutron scattering cross sections of CaH 2 are evaluated in this work to establish accurate data for use in reactor design. The present evaluation corrects the inaccuracies of the JEFF-3.3 data, and yields three distinct libraries: Ca in CaH 2 , H 1 in CaH 2 , and H 2 in CaH 2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a Pulsed Slowing-Down-Time Benchmark of Neutron Thermalization in Graphite

Graphite is a classic neutronic material that has been used as both a reactor reflector and moderator in various nuclear reactor systems. The ability to accurately predict the slowing down and thermalization of neutrons in graphite can have significant implications on the safety and operation of such reactor systems. In reactors, the neutron thermalization process is quantified using the thermal scattering law (TSL) and related cross sections for a given moderator. An ideal approach to assess the validity of TSL data is using benchmark measurement based on the pulsed Slowing-Down-Time technique and its comparison with the appropriate graphite nuclear library. In this work, experimental measurement and computational Monte Carlo simulations were performed to benchmark the slowing down characteristics and thermalization of neutrons in nuclear (reactor-grade) graphite. Given the density of graphite, various graphite libraries were selected for the benchmark analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Delayed Neutron Sensitivities for Several ICSBEP Benchmarks using MCNP

The effective delayed neutron (β$_{eff}$) is a very important parameter for reactor and criticality applications. This parameter is equal to the difference in reactivity between delayed critical ($k_{eff}$ = 1, which requires both prompt and delayed neutrons to achieve criticality) and prompt critical ($k_p$ = 1, which requires only prompt neutrons to achieve criticality). This is often referred to as the delayed critical "window" (the region of criticality between delayed and prompt critical). β$_{eff}$ is a reactor kinetics parameters and depends on the nuclides in the system that undergo fission as well as the spectral characteristics of the system. Measurements of β$_{eff}$ have been performed for many criticality experiments. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond $k_{eff}$. Our team has recently investigated the use of pulsed spheres for nuclear data validation. Several other measurement methods are also of interest, including β$_{eff}$ (investigated here) and reactivity coefficients (investigated in a separate work at this same meeting). One focus of our work is to determine if other methods are complimentary to the critical experiments already utilized for nuclear data validation. This is important because if a method has similar sensitivities then it will not be particularly useful for nuclear data validation as it will provide the same information as the critical experiments already being used. Here "similar" could refer to several characteristics, one being the shape of a sensitivity profile over energy. In the future, these methods will be utilized (with both existing and new experiments) in machine learning algorithms for nuclear validation, similar to what is currently done for criticality experiments. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for that parameter. This work looks at one approach to estimate β$_{eff}$ sensitivities by utilizing $k_{eff}$ sensitivities within Monte Carlo N-Particle ® Code Version 6.2. This is applied to several criticality benchmarks. Results are compared and the benefits and limitations of this approach are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Energy Reactions of the n+ 233 U Nuclear Compound System and Its Initial Validation

The strong negative gradient as a function of the epithermal fission fraction (FEPIT) observed in both Evaluated Nuclear Data File (ENDF)/B-VII.1 and ENDF/B-VIII.0 nuclear data libraries poses new challenges for the verification of the n+ 233 U nuclear compound system, especially in the low energy range. The aim of this paper is to summarize the steps forward to consistently update the 233 U evaluated nuclear data to attain improved performance in benchmark calculations; this work is described in detail in a forthcoming paper by Pigni et al.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RPI LINAC refurbishment and upgrade project

The Electron Linear Accelerator at Rensselaer Polytechnic Institute (RPI) was constructed in the late 1950s and started operation in 1961 [1]. The facility was designed and used primarily for measurements of Nuclear Data (ND) with emphasis on the resonance energy region. As such it was designed to produce short pulses of neutrons (5-5000 ns) and equipped with detection stations at different neutron flight path distances from the source (15 m-250 m). When the LINAC started operation it was one of the most powerful accelerators in the world for high energy-resolution measurements in the resonance region. The original LINAC with some upgrades is still in operation but no longer provides world class capabilities for measurements with short pulses. In 2011 discussions between the RPI ND group, Naval Reactors, and the Nuclear Criticality Safety Program about the future of the LINAC concluded that maintaining the capability to perform world-class nuclear data measurements at RPI was desirable. To that end, it was decided to refurbish the facility and upgrade the accelerator capabilities to enable high accuracy measurement in the resonance region with narrow neutron pulse and high electron beam power. Located at a major US technical university, this project provides a needed US nuclear data capability for both research and education, and also includes external users and industrial applications.

43 PARTICLE ACCELERATORS↗

Bayesian Monte Carlo Evaluation Framework for Imperfect Nuclear Data

Bayesian evaluation of resolved resonance region (RRR) nuclear data has historically been carried out using the generalized least squares (GLS) formalism, as implemented in, e.g., SAMMY. We have recently developed a prototype of Bayesian Monte Carlo (BMC) evaluation framework, implemented using a Markov Chain Monte Carlo (MCMC) method with a Metropolis-Hastings (MH) acceptance criterion. This was done in order to remove the approximations underlying the conventional GLS evaluations, namely, the linear approximation, and the approximation that all probability density functions (PDFs) are of the normal kind. Recent works by others have used similar stochastic approaches to quantify cross section uncertainties from ENDF evaluated co-variances, and/or, from integral benchmark data, but those have not been conceived as an evaluation framework like the one presented here.

97 MATHEMATICS AND COMPUTING↗