Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

DMLC tracking and gating can improve dose coverage for prostate VMAT

Purpose: To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. Methods: A dose reconstruction method was used to retrospectively assess the dose distributions delivered without motion correction during volumetric modulated arc therapy fractions for 20 fractions of five prostate cancer patients who received conventionally fractionated radiotherapy. These delivered dose distributions were compared with the dose distributions which would have been delivered had DMLC tracking or gating motion correction strategies been implemented. The delivered dose distributions were constructed by incorporating the observed prostate motion with the patient's original treatment plan to simulate the treatment delivery. The DMLC tracking dose distributions were constructed using the same dose reconstruction method with the addition of MLC positions from Linac log files obtained during DMLC tracking simulations with the observed prostate motions input to the DMLC tracking software. The gating dose distributions were constructed by altering the prostate motion to simulate the application of a gating threshold of 3 mm for 5 s. Results: The delivered dose distributions showed that dosimetric effects of intrafraction prostate motion could be substantial for some fractions, with an estimated dose decrease of more than 19% and 34% from the planned CTVD{sub 99%} and PTV D{sub 95%} values, respectively, for one fraction. Evaluation of dose distributions for DMLC tracking and gating deliveries showed that both interventions were effective in improving the CTV D{sub 99%} for all of the selected fractions to within 4% of planned value for all fractions. For the delivered dose distributions the difference in rectum V{sub 65%} for the individual fractions from planned ranged from −44% to 101% and for the bladder V{sub 65%} the range was −61% to 26% from planned. The application of tracking decreased the maximum rectum and bladder V{sub 65%} difference to 6% and 4%, respectively. Conclusions: For the first time, the dosimetric impact of DMLC tracking and gating to account for intrafraction motion during prostate radiotherapy has been assessed and compared with no motion correction. Without motion correction intrafraction prostate motion can result in a significant decrease in target dose coverage for a small number of individual fractions. This is unlikely to effect the overall treatment for most patients undergoing conventionally fractionated treatments. Both DMLC tracking and gating demonstrate dose distributions for all assessed fractions that are robust to intrafraction motion.

60 APPLIED LIFE SCIENCES↗

The effect of visual-motion time delays on pilot performance in a pursuit tracking task

A study has been made to determine the effect of visual-motion time delays on pilot performance of a simulated pursuit tracking task. Three interrelated major effects have been identified: task difficulty, motion cues, and time delays. As task difficulty, as determined by airplane handling qualities or target frequency, increases, the amount of acceptable time delay decreases. However, when relatively complete motion cues are included in the simulation, the pilot can maintain his performance for considerably longer time delays. In addition, the number of degrees of freedom of motion employed is a significant factor.

Miller, G. K., Jr.↗

Determination of polar motion and earth rotation from laser tracking of satellites

Laser tracking of the Lageos spacecraft has been used to derive the position of the earth's pole of rotation at intervals during October, November and December 1976. The estimated precision of the results is 0.01 to 0.02 arcseconds in both x and y components, although the formal uncertainty is an order of magnitude better, and there is general agreement with the Bureau International de l'Heure smoothed pole path to about 0.02 arcseconds. Present orbit determination capability of Lageos is limited to about 25 cm rms fit to data over periods of 5 days and about 50 cm over 50 days. The present major sources of error in the perturbations of Lageos are earth and ocean tides followed by the earth's gravity field, and solar and earth reflected radiation pressure. Ultimate accuracy for polar motion and earth rotation from Lageos after improved modeling of the perturbing forces appears to be of order + or - 5 cm for polar motion over a period of about one day and about + or - 0.2 to + or - 0.3 milliseconds in UT for periods up to 2 or 3 months.

Smith, D. E.↗

Brownian motion studies of viscoelastic colloidal gels by rotational single particle tracking

Colloidal gels have unique properties due to a complex microstructure which forms into an extended network. Although the bulk properties of colloidal gels have been studied, there has been difficulty correlating those properties with individual colloidal dynamics on the microscale due to the very high viscosity and elasticity of the material. We utilize rotational X-ray tracking (RXT) to investigate the rotational motion of component crystalline colloidal particles in a colloidal gel of alumina and decanoic acid. Our investigation has determined that the high elasticity of the bulk is echoed by a high elasticity experienced by individual colloidal particles themselves but also finds an unexpected high degree of rotational diffusion, indicating a large degree of freedom in the rotational motion of individual colloids even within a tightly bound system.

36 MATERIALS SCIENCE↗

A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software TEMA Motion is used to track the spot which marked the cage surface. Finally, by developing the MATLAB program, a Lissajous’ figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid simulations of plasma transport by Kelvin-Helmholtz instability at the magnetopause: magnetic shear

Two-dimensional hybrid (kinetic ions, massless fluid electrons) simulations of the Kelvin Helmholtz Instability (KHI) for a magnetopause configuration with a magnetic shear across the boundary are carried out to examine how the transport of magnetosheath plasma into the magnetosphere is affected by the shear field. Low magnetic shear conditions where the magnetosheath magnetic field is within 30{sup o} of northward is included in the simulations because KHI is thought to be important for plasma transport only for northward or near-northward interplanetary magnetic field orientations. The simulations show that coherent vortices can grow for these near-northward angles, and that they are sometimes more coherent than for pure northward conditions because the turbulence which breaks-down these vortices is reduced when there are magnetic tension forces. With increasing magnetic shear angle, the growth rate is reduced, and the vortices do not grow to as large of size which reduces the plasma transport. By tracking the individual particle motions diffusion coefficients can be obtained for the system, where the diffusion is not classical in nature but instead has a time dependence resulting from both the increasingly large-scale vortex motion and the small-scale turbulence generated in the break-down of the instabilities. Results indicate that diffusion on the order of 10{sup 9} m{sup 2}/s could possibly be generated by KHI on the flanks of the magnetosphere.

58 GEOSCIENCES↗

Space infrared telescope pointing control system. Infrared telescope tracking in the presence of target motion

The use of charge-coupled-devices, or CCD's, has been documented by a number of sources as an effective means of providing a measurement of spacecraft attitude with respect to the stars. A method exists of defocussing and interpolation of the resulting shape of a star image over a small subsection of a large CCD array. This yields an increase in the accuracy of the device by better than an order of magnitude over the case when the star image is focussed upon a single CCD pixel. This research examines the effect that image motion has upon the overall precision of this star sensor when applied to an orbiting infrared observatory. While CCD's collect energy within the visible spectrum of light, the targets of scientific interest may well have no appreciable visible emissions. Image motion has the effect of smearing the image of the star in the direction of motion during a particular sampling interval. The presence of image motion is incorporated into a Kalman filter for the system, and it is shown that the addition of a gyro command term is adequate to compensate for the effect of image motion in the measurement. The updated gyro model is included in this analysis, but has natural frequencies faster than the projected star tracker sample rate for dim stars. The system state equations are reduced by modelling gyro drift as a white noise process. There exists a tradeoff in selected star tracker sample time between the CCD, which has improved noise characteristics as sample time increases, and the gyro, which will potentially drift further between long attitude updates. A sample time which minimizes pointing estimation error exists for the random drift gyro model as well as for a random walk gyro model.

Powell, J. D.↗

Motion detection, novelty filtering, and target tracking using an interferometric technique with a GaAs phase conjugate mirror

A method and apparatus is disclosed for detecting and tracking moving objects in a noise environment cluttered with fast-and slow-moving objects and other time-varying background. A pair of phase conjugate light beams carrying the same spatial information commonly cancel each other out through an image subtraction process in a phase conjugate interferometer, wherein gratings are formed in a fast photo-refractive phase conjugate mirror material. In the steady state, there is no output. When the optical path of one of the two phase conjugate beams is suddenly changed, the return beam loses its phase conjugate nature and the inter-ferometer is out of balance, resulting in an observable output. The observable output lasts until the phase conjugate nature of the beam has recovered. The observable time of the output signal is roughly equal to the formation time of the grating. If the optical path changing time is slower than the formation time, the change of optical path becomes unobservable, because the index grating can follow the change. Thus, objects traveling at speeds which result in a path changing time which is slower than the formation time are not observable and do not clutter the output image view.

Cheng, Li-Jen↗

Dynamic modeling and control of multibody mechanical systems which are structurally flexible

This paper concerns the dynamic modeling and control of multibody, open-chained, structurally flexible, mechanical systems where the bodies are connected by revolute joints. The equations of motion are formulated based on a matrix form of Lagrange's equations for inertial quasi-coordinates. Each body is treated as a substructure of the system. For the purposes of simulation and control, the equations of motion are separated into two sets of equations using a perturbation approach: one to describe large rigid-body motions of the articulated system and the other to describe small linear motions of the bodies about the large motions. A biologically natural control strategy is used for vibration suppression and tracking the prescribed motion.

Quinn, R. D.↗

Motion detection, novelty filtering, and target tracking using an interferometric technique with GaAs phase conjugate mirror

A method and apparatus for detecting and tracking moving objects in a noise environment cluttered with fast- and slow-moving objects and other time-varying background. A pair of phase conjugate light beams carrying the same spatial information commonly cancel each other out through an image subtraction process in a phase conjugate interferometer, wherein gratings are formed in a fast photorefractive phase conjugate mirror material. In the steady state, there is no output. When the optical path of one of the two phase conjugate beams is suddenly changed, the return beam loses its phase conjugate nature and the interferometer is out of balance, resulting in an observable output. The observable output lasts until the phase conjugate nature of the beam has recovered. The observable time of the output signal is roughly equal to the formation time of the grating. If the optical path changing time is slower than the formation time, the change of optical path becomes unobservable, because the index grating can follow the change. Thus, objects traveling at speeds which result in a path changing time which is slower than the formation time are not observable and do not clutter the output image view.

Cheng, Li-Jen↗

Geolocation tracking for human identification and activity recognition using radar deep transfer learning

Abstract Human identification and activity recognition (HIAR) is crucial for many applications, such as surveillance, smart homes, and assisted living. As a sensing modality, radar has many unique characteristics including privacy protection, and contactless sensing. Single classification systems have shown to be accurate, but for long‐term solutions both human identification (ID) and human activity recognition (HAR) will need to be integrated in one system where it can be utilised simultaneously. In this article, a novel radar‐based human tracking system is presented where three classifiers are utilised to identify the subject and his/her behaviour. For any kind of motion, the system tracks the subject and detect the type of his/her motion. Based on the detected type of motion, the three classifiers are utilised for identification and activity recognition. The classifiers are built utilising deep transfer learning where three radar datasets are established to train and validate each of the deep networks. To recognise six activities and 10 human subjects, the three classifiers, namely, HAR, Gait ID, and Heart sound ID, achieve superior performance compared to the best reported results in literature with classification accuracies of 97.6%, 100%, and 41.8% respectively. Three successful examples are presented to demonstrate the introduced concept.

Alkasimi, Ahmad↗

Use of Implanted Markers and Interportal Adjustment With Real-Time Tracking Radiotherapy System to Reduce Intrafraction Prostate Motion

Purpose: Interportal adjustment was applied to patients with prostate cancer using three fiducial markers and two sets of fluoroscopy in a real-time tumor-tracking radiotherapy (RTRT) system. The incidence of table position adjustment required to keep intrafractional uncertainty within 2.0 mm was investigated in this study. Methods and Materials: The coordinates of the center of gravity of the three fiducial markers were measured at the start of every portal irradiation in intensity-modulated radiotherapy (IMRT) with seven ports. The table position was adjusted to the planned position if the discrepancy was larger than 2.0 mm in the anterior-posterior (AP), cranial-caudal (CC), or left-right (LR) directions. In total, we analyzed 4,541 observations in 20 patients who received 70 Gy in 30 fractions (7.6 times a day on average). Results: The incidence of table position adjustment at 10 minutes from the initial setup of each treatment was 14.2%, 12.3%, and 5.0% of the observations in the AP, CC, and LR directions, respectively. The accumulated incidence of the table position adjustment was significantly higher at 10 minutes than at 2 minutes for AP (p = 0.0033) and CC (p = 0.0110) but not LR (p = 0.4296). An adjustment greater than 5 mm was required at least once in the treatment period in 11 (55%) patients. Conclusions: Interportal adjustment of table position was required in more than 10% of portal irradiations during the 10-minute period after initial setup to maintain treatment accuracy within 2.0 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and evaluation of a prototype tracking system using the treatment couch

Purpose: Tumor motion increases safety margins around the clinical target volume and leads to an increased dose to the surrounding healthy tissue. The authors have developed and evaluated a one-dimensional treatment couch tracking system to counter steer respiratory tumor motion. Three different motion detection sensors with different lag times were evaluated. Methods: The couch tracking system consists of a motion detection sensor, which can be the topometrical system Topos (Cyber Technologies, Germany), the respiratory gating system RPM (Varian Medical Systems) or a laser triangulation system (Micro Epsilon), and the Protura treatment couch (Civco Medical Systems). The control of the treatment couch was implemented in the block diagram environment Simulink (MathWorks). To achieve real time performance, the Simulink models were executed on a real time engine, provided by Real-Time Windows Target (MathWorks). A proportional-integral control system was implemented. The lag time of the couch tracking system using the three different motion detection sensors was measured. The geometrical accuracy of the system was evaluated by measuring the mean absolute deviation from the reference (static position) during motion tracking. This deviation was compared to the mean absolute deviation without tracking and a reduction factor was defined. A hexapod system was moving according to seven respiration patterns previously acquired with the RPM system as well as according to a sin{sup 6} function with two different frequencies (0.33 and 0.17 Hz) and the treatment table compensated the motion. Results: A prototype system for treatment couch tracking of respiratory motion was developed. The laser based tracking system with a small lag time of 57 ms reduced the residual motion by a factor of 11.9 ± 5.5 (mean value ± standard deviation). An increase in delay time from 57 to 130 ms (RPM based system) resulted in a reduction by a factor of 4.7 ± 2.6. The Topos based tracking system with the largest lag time of 300 ms achieved a mean reduction by a factor of 3.4 ± 2.3. The increase in the penumbra of a profile (1 × 1 cm{sup 2}) for a motion of 6 mm was 1.4 mm. With tracking applied there was no increase in the penumbra. Conclusions: Couch tracking with the Protura treatment couch is achievable. To reliably track all possible respiration patterns without prediction filters a short lag time below 100 ms is needed. More scientific work is necessary to extend our prototype to tracking of internal motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of Lagrangian/Eulerian approaches for tracking the kinematics of high deformation solid motion.

The modeling of solids is most naturally placed within a Lagrangian framework because it requires constitutive models which depend on knowledge of the original material orientations and subsequent deformations. Detailed kinematic information is needed to ensure material frame indifference which is captured through the deformation gradient F. Such information can be tracked easily in a Lagrangian code. Unfortunately, not all problems can be easily modeled using Lagrangian concepts due to severe distortions in the underlying motion. Either a Lagrangian/Eulerian or a pure Eulerian modeling framework must be introduced. We discuss and contrast several Lagrangian/Eulerian approaches for keeping track of the details of material kinematics.

97 MATHEMATICS AND COMPUTING↗

High-resolution 3D microwave imaging of a moving target using optical motion capture

Three-dimensional microwave or millimeter-wave imaging is usually performed using a fixed two-dimensional planar or cylindrical aperture that is defined using a 2D array or precise mechanical scanning of a transceiver or linear antenna array. For some applications, it is more convenient to manually pass a linear array over the scene of interest, or equivalently, move the target in front of the linear array to scan an effective aperture. This paper explores high-resolution 3D microwave imaging of a moving target by using optical motion capture to track the moving target, and developing image reconstruction techniques that account for the irregular motion.

Millimeter-wave imaging, microwave imaging, Concea↗

Progress in Navier-Stokes Simulation of Delta Wing Maneuver Aerodynamics

This paper will summarize recent progress in the numerical simulation of high incidence vortical flow about a generic 65 degree sweep delta wing using the three dimensional, time-dependent, Reynolds averaged, Navier-Stokes (RANS) equations. Computations have been carried out at 15 and 30 degrees angle of attack under subsonic turbulent flow conditions, and compared with experimental data provided by Hanff, Jenkins, and their colleagues. This work has already been published elsewhere and widely disseminated. Computations carried out at 15 degrees angle of attack included static roll angles ranging up to 65 degrees, and a large-amplitude (40 degree), high rate (7 Hz), forced roll motion. There was very good agreement between computed and experimental forces and moments, and static surface pressures. There was a significant hysteresis of the dynamic rolling moment due to the high rate of roll motion. At this angle of attack, no vortex breakdown was observed in the computations or experiment. Computations were also carried out at 30 degrees angle of attack, where vortex breakdown was present in both the computations and experiment. There was overall good agreement in the computed and experimental forces and moments. The static rolling moment varied with roll angle in a highly nonlinear manner, and exhibited three stable trim points and two unstable trim points. This behavior was attributed to the presence of vortex breakdown. Two large-amplitude (30 degrees), high-rate (10 Hz) forced roll motions were computed. The dynamics of the vortex breakdown motion was dramatically visualized by tracking the time-dependent motion of particles released near the delta wing apex. This numerical visualization is analogous to experimental smoke flow techniques. In one of the dynamic cases the breakdown was found to move off the wing, convected downwind of the trailing edge, and later reformed near the trailing edge through an instability of the vortex core. A damped free-to-roll motion was also computed by releasing the wing from rest at 40 degrees of roll. The wing went to the same trim point as in the experiment.

Chaderjian, Neal M.↗