Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

The relation of motion sickness to the spatial-temporal properties of velocity storage

Tilting the head in roll to or from the upright while rotating at a constant velocity (roll while rotating, RWR) alters the position of the semicircular canals relative to the axis of rotation. This produces vertical and horizontal nystagmus, disorientation, vertigo, and nausea. With recurrent exposure, subjects habituate and can make more head movements before experiencing overpowering motion sickness. We questioned whether promethazine lessened the vertigo or delayed the habituation, whether habituation of the vertigo was related to the central vestibular time constant, i.e., to the time constant of velocity storage, and whether the severity of the motion sickness was related to deviation of the axis of eye velocity from gravity. Sixteen subjects received promethazine and placebo in a double-blind, crossover study in two consecutive 4-day test series 1 month apart, termed series I and II. Horizontal and vertical eye movements were recorded with video-oculography while subjects performed roll head movements of approx. 45 degrees over 2 s to and from the upright position while being rotated at 138 degrees /s around a vertical axis. Motion sickness was scaled from 1 (no sickness) to an endpoint of 20, at which time the subject was too sick to continue or was about to vomit. Habituation was determined by the number of head movements that subjects made before reaching the maximum motion sickness score of 20. Head movements increased steadily in each session with repeated testing, and there was no difference between the number of head movements made by the promethazine and placebo groups. Horizontal and vertical angular vestibulo-ocular reflex (aVOR) time constants declined in each test, with the declines being closely correlated to the increase in the number of head movements. The strength of vertiginous sensation was associated with the amount of deviation of the axis of eye velocity from gravity; the larger the deviation of the eye velocity axis from gravity, the more severe the motion sickness. Thus, promethazine neither reduced the nausea associated with RWR, nor retarded or hastened habituation. The inverse relationship between the aVOR time constants and number of head movements to motion sickness, and the association of the severity of motion sickness with the extent, strength, and time of deviation of eye velocity from gravity supports the postulate that the spatiotemporal properties of velocity storage, which are processed between the nodulus and uvula of the vestibulocerebellum and the vestibular nuclei, are likely to represent the source of the conflict responsible for producing motion sickness.

NASA Discipline Neuroscience↗

Influence of Continuous Table Motion on Patient Breathing Patterns

Purpose: To investigate the influence of continuous table motion on patient breathing patterns for compensation of moving targets by a robotic treatment couch. Methods and Materials: Fifteen volunteers were placed on a robotic treatment couch, and the couch was moved on different breathing-correlated and -uncorrelated trajectories. External abdominal breathing motion of the patients was measured using an infrared camera system. The influence of table motion on breathing range and pattern was analyzed. Results: Continuous table motion was tolerated well by all test persons. Volunteers reacted differently to table motion. Four test persons showed no change of breathing range and pattern. Increased irregular breathing was observed in 4 patients; however, irregularity was not correlated with table motion. Only 4 test persons showed an increase in mean breathing amplitude of more than 2mm during motion of the couch. The mean cycle period decreased by more than 1 s for 2 test persons only. No abrupt changes in amplitude or cycle period could be observed. Conclusions: The observed small changes in breathing patterns support the application of motion compensation by a robotic treatment couch.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Liver Tumor Motion With and Without Abdominal Compression Using Cine-Magnetic Resonance Imaging

Purpose: Abdominal compression (AC) can be used to reduce respiratory liver motion in patients undergoing liver stereotactic body radiotherapy. The purpose of the present study was to measure the changes in three-dimensional liver tumor motion with and without compression using cine-magnetic resonance imaging. Patients and Methods: A total of 60 patients treated as a part of an institutional research ethics board-approved liver stereotactic body radiotherapy protocol underwent cine T2-weighted magnetic resonance imaging through the tumor centroid in the coronal and sagittal planes. A total of 240 cine-magnetic resonance imaging sequences acquired at one to three images each second for 30-60 s were evaluated using an in-house-developed template matching tool (based on the coefficient correlation) to measure the magnitude of the tumor motion. The average tumor edge displacements were used to determine the magnitude of changes in the caudal-cranial (CC) and anteroposterior (AP) directions, with and without AC. Results: The mean tumor motion without AC of 11.7 mm (range, 4.8-23.3) in the CC direction was reduced to 9.4 mm (range, 1.6-23.4) with AC. The tumor motion was reduced in both directions (CC and AP) in 52% of the patients and in a single direction (CC or AP) in 90% of the patients. The mean decrease in tumor motion with AC was 2.3 and 0.6 mm in the CC and AP direction, respectively. Increased motion occurred in one or more directions in 28% of patients. Clinically significant (>3 mm) decreases were observed in 40% and increases in <2% of patients in the CC direction. Conclusion: AC can significantly reduce three-dimensional liver tumor motion in most patients, although the magnitude of the reduction was smaller than previously reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE PROPER MOTION OF THE MAGELLANIC CLOUDS. I. FIRST RESULTS AND DESCRIPTION OF THE PROGRAM

We present the first results of a ground-based program to determine the proper motion of the Magellanic Clouds (MCs) relative to background quasars (QSO), being carried out using the Irenee du Pont 2.5 m telescope at Las Campanas Observatory, Chile. Eleven QSO fields have been targeted in the Small Magellanic Cloud (SMC) over a time base of six years, and with seven epochs of observation. One quasar field was targeted in the Large Magellanic Cloud (LMC), over a time base of five years, and with six epochs of observation. The shorter time base in the case of the LMC is compensated by the much larger amount of high-quality astrometry frames that could be secured for the LMC quasar field (124 frames), compared to the SMC fields (an average of roughly 45 frames). In this paper, we present final results for field Q0557-6713 in the LMC and field Q0036-7227 in the SMC. From field Q0557-6713, we have obtained a measured proper motion of {mu}{sub {alpha}}cos {delta} = +1.95 {+-} 0.13 mas yr{sup -1}, {mu}{sub {delta}} = +0.43 {+-} 0.18 mas yr{sup -1} for the LMC. From field Q0036-7227, we have obtained a measured proper motion of {mu}{sub {alpha}} cos{delta} = +0.95 {+-} 0.29 mas yr{sup -1}, {mu}{sub {delta}} = -1.14 {+-} 0.18 mas yr{sup -1} for the SMC. Although we went through the full procedure for another SMC field (QJ0036-7225), on account of unsolvable astrometric difficulties caused by blending of the QSO image, it was impossible to derive a reliable proper motion. Current model rotation curves for the plane of the LMC indicate that the rotational velocity (V {sub rot}) at the position of LMC field Q0557-6713 can be as low as 50 km s{sup -1}, or as high as 120 km s{sup -1}. A correction for perspective and rotation effects leads to a center of mass proper motion for the LMC of {mu}{sub {alpha}} cos{delta} = +1.82 {+-} 0.13 mas yr{sup -1}, {mu}{sub {delta}} = +0.39 {+-} 0.15 mas yr{sup -1} (V {sub rot} = 50 km s{sup -1}), and to {mu}{sub {alpha}} cos{delta} = +1.61 {+-} 0.13 mas yr{sup -1}, {mu}{sub {delta}} = +0.60 {+-} 0.15 mas yr{sup -1} (V {sub rot} = 120 km s{sup -1}). Assuming that the SMC has a disk-like central structure, but that it does not rotate, we obtain a center of mass proper motion for the SMC of {mu}{sub {alpha}} cos{delta} = +1.03 {+-} 0.29 mas yr{sup -1}, {mu}{sub {delta}} = -1.09 {+-} 0.18 mas yr{sup -1}. Our results are in reasonable agreement with most previous determinations of the proper motion of the MCs, including recent Hubble Space Telescope measurements. Complemented with published values of the radial velocity of the centers of the LMC and SMC, we have used our proper motions to derive the galactocentric (gc) velocity components of the MCs. For the LMC, we obtain V {sub gc,t} = +315 {+-} 20 km s{sup -1}, V {sub gc,r} = +86 {+-} 17 km s{sup -1} (V {sub rot} = 50 km s{sup -1}), and V {sub gc,t} = +280 {+-} 24 km s{sup -1}, V {sub gc,r} = +94 {+-} 17 km s{sup -1} (V {sub rot} = 120 km s{sup -1}). For the SMC, we obtain V {sub gc,t} = +258 {+-} 50 km s{sup -1}, V {sub gc,r} = +20 {+-} 44 km s{sup -1}. These velocities imply a relative velocity between the LMC and SMC of 84 {+-} 50 km s{sup -1}, for V {sub rot,LMC} = 50 km s{sup -1}, and 62 {+-} 63 km s{sup -1} for V {sub rot,LMC} = 120 km s{sup -1}. Albeit our large errors, these values are not inconsistent with the standard assumption that the MCs are gravitationally bound to each other.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of the Earthquake Rupture on Ground-Motion Variability of the 24 August 2016 M w 6.2 Amatrice, Italy, Earthquake

Here, the devastating 24 August 2016 M w 6.2 earthquake that struck Amatrice, Italy, marked the beginning of a prolonged seismic sequence dominated by three subsequent M w ≥6.0 events in the central Apennines region. The earthquake destroyed Amatrice’s historic center, claiming the lives of 299 individuals and causing widespread damage in the neighboring villages. The severity of the ground shaking, with a recorded maximum acceleration of 850 cm/s 2 on the east–west component at the Amatrice station, was far greater than the predicted acceleration based on the Italian ground-motion model (GMM). As pointed out by several investigations, the observed ground-motion amplitude and its spatial variability during the earthquake can be linked to specific rupture characteristics, including slip distribution and rupture directivity effects revealed by the observed data (Tinti et al., 2016; Pischiutta et al., 2021). In this study, we conducted physics-based 3D numerical simulations of ground motion for the Amatrice earthquake for frequencies up to 3 Hz. We employed a series of kinematic rupture models and a well-constrained local 3D velocity model incorporating surface topography. The kinematic rupture realizations were generated using multiscale hybrid and fully stochastic models, following the technique proposed by Graves and Pitarka (2016). We focused on assessing the sensitivity of near-fault ground-motion amplitudes to earthquake rupture characteristics, in particular, the spatial slip pattern. To evaluate the quality of our simulations, we employed goodness-of-fit measurements performed in comparisons of simulated and recorded ground motions. The simulated ground motions compare well with the recorded data and predictions from GMMs for Italy, ITA18 (Lanzano et al., 2019). However, we found that the simulated interevent ground-motion variability (randomness in the source process) of peak ground velocity, σ (PGV) is higher than the constant σ (PGV) predicted by conventional GMMs. Our simulations using several rupture scenarios demonstrate that the near-fault ground-motion amplification pattern is directly related to the slip distribution pattern.

3D Ground Motions Simulations↗

Effect of geometric and motion tracking errors on awake small animal SPECT

A series of simulation studies were performed to evaluate the effects of geometric and motion tracking errors on reconstruction image quality for a single pinhole collimator awake animal imaging SPECT system. List-mode SPECT data generated using a custom Monte Carlo program that incorporated experimental mouse motion data were reconstructed by MLEM with Siddon's ray tracing. To better understand the impact of motion tracking and system geometric parameter errors on reconstructed system data, an offset of up to 1 mm or degree was separately applied to each for evaluation. In the absence of motion tracking or system geometric error, the applied motion compensation algorithm successfully reconstructed volumes without any degradation or distortion. Presented results reveal that motion tracking errors propagate through the SPECT reconstruction process. However, it is confirmed that the impact of tracking errors in the currently employed motion tracking system, is minimal because of their accuracy. The results also reveal the direct and indirect impact of geometric errors to motion compensated reconstruction quality and that a wrong assumption of pinhole transaxial position produces the most amount of distortion of all the investigated errors. Finally, system geometric errors are shown to have a greater impact on reconstruction quality than equivalent tracking errors.

60 APPLIED LIFE SCIENCES↗

Determination of Respiratory Motion for Distal Esophagus Cancer Using Four-Dimensional Computed Tomography

Purpose: To investigate the motion characteristics of distal esophagus cancer primary tumors using four-dimensional computed tomography (4D CT). Methods and Materials: Thirty-one consecutive patients treated for esophagus cancer who received respiratory-gated 4D CT imaging for treatment planning were selected. Deformable image registration was used to map the full expiratory motion gross tumor volume (GTV) to the full-inspiratory CT image, allowing quantitative assessment of each voxel's displacement. These displacements were correlated with patient tumor and respiratory characteristics. Results: The mean (SE) tidal volume was 608 (73) mL. The mean GTV volume was 64.3 (10.7) mL on expiration and 64.1 (10.7) mL on inspiration (no significant difference). The mean tumor motion in the x-direction was 0.13 (0.006) cm (average of absolute values), in the y-direction 0.23 (0.01) cm (anteriorly), and in the z-direction 0.71 (0.02) cm (inferiorly). Tumor motion correlated with tidal volume. Comparison of tumor motion above vs. below the diaphragm was significant for the average net displacement (p = 0.014), motion below the diaphragm was greater than above. From the cumulative distribution 95% of the tumors moved less than 0.80 cm radially and 1.75 cm inferiorly. Conclusions: Primary esophagus tumor motion was evaluated with 4D CT. According to the results of this study, when 4D CT is not available, a radial margin of 0.8 cm and axial margin of {+-}1.8 cm would provide tumor motion coverage for 95% of the cases in our study population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Consequences of Intrafraction Prostate Motion

Purpose: To analyze characteristics of intrafraction prostate motion, monitored using the Calypso system, and investigate dosimetric consequences of the motion for different clinical target volume (CTV) to planning target volume (PTV) margins. Methods and Materials: Motion characteristics were analyzed for 1,267 tracking sessions and 35 patients. Using prostate-PTV margins of 0, 1, 2, 3, and 5 mm, dose metrics for the prostate gland, bladder, and rectum were evaluated for scenarios including patient population, individual patients showing the greatest motion during the course of treatment, and the individual session with the largest overall movement. Composite dose distributions incorporating motion blurring were calculated by convolving static intensity-modulated radiotherapy plans with corresponding motion probability functions. Results: For prostate-PTV margins of 2 mm or greater, intrafraction motion did not compromise prostate dose coverage for either the patient population or individual patients. For the patient showing the largest overall movement, the prostate equivalent uniform dose was reduced by only 17.4 cGy (0.23%), and the minimum prostate dose remained greater than 95% of the nominal dose. For margins less than 2 mm, the prostate dose-volume histogram in the same patient was slightly compromised, and the equivalent uniform dose was reduced by 38.5 cGy (0.51%). Sparing of the bladder and rectum was improved substantially by reducing margins. Conclusions: Although significant motion can be observed during individual fractions, the dosimetric consequences are insignificant during a typical course of radiotherapy (30-40 fractions) with CTV-PTV margins of 2 mm or greater provided that the Calypso system is applied for pretreatment localization. Further reduction of the margin is possible if intrafraction realignment is performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Computed Tomography Scan Analysis of Tumor and Organ Motion at Varying Levels of Abdominal Compression During Stereotactic Treatment of Lung and Liver

Purpose: To investigate the effectiveness of different abdominal compression levels on tumor and organ motion during stereotactic body radiotherapy of lower lobe lung and liver tumors using four-dimensional (4D)-CT scan analysis. Methods and Materials: Three 4D-CT scans were acquired for 10 patients first using with no compression and then compared with two different levels of abdominal compression. The position of the tumor and various organs were defined at the peak inspiratory and expiratory phases and compared to determine the maximum motion. Results: Mean ({+-}SD) medium compression force (MC) and high compression force (HC) were 47.6 {+-} 16.0 N and 90.7 {+-} 27.1 N, respectively. Mean overall tumor motion was 13.6 mm (2{sigma} [2 sigma] 11.5-15.6), 8.3 mm (2{sigma} 6.0-10.5), and 7.2 mm (2{sigma} 5.4-9.0) for no compression, MC, and HC, respectively. A significant difference in the control of both superior-inferior (SI) and overall motion of tumors was seen with the application of MC and HC when compared with no compression (p < 0.0001 for both). High compression force improved SI and overall tumor motion compared with MC, but this was only significant for SI motion (p = 0.04 and p = 0.06). Significant control of organ motion was only seen in the pancreas (p = 0.01). Conclusions: Four-dimensional CT shows significant control of both lower lobe lung and liver tumors using abdominal compression. High levels of compression improve SI tumor motion when compared with MC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Interfraction Prostate Motion Using Megavoltage Cone Beam Computed Tomography

Purpose: Determine the degree of interfraction prostate motion and its components measured by using daily megavoltage (MV) cone beam computed tomography (CBCT) imaging. Methods and Materials: A total of 984 daily MV CBCT images from 24 patients undergoing definitive intensity-modulated radiotherapy for localized prostate cancer were analyzed retrospectively. Pretreatment couch shifts, based on physician registration of MV CBCT to planning CT data sets, were used as a measure of daily interfraction motion. Off-line bony registration was performed to separate bony misalignment from internal organ motion. Interobserver and intraobserver variation studies were performed on 20 MV CBCT images. Results: Mean interfraction prostate motion was 6.7 mm, with the greatest single-axis deviation in the anterior-posterior (AP) direction. The largest positional inaccuracy was accounted for by systematic deviations in bony misalignment, whereas random deviations occurred from bony misalignment and internal prostate motion. In the aggregate, AP motion did not correlate with days elapsed since beginning therapy or on average with rectal size at treatment planning. Interobserver variation was greatest in the AP direction, decreased in experienced observers, and further decreased in intraobserver studies. Mean interfraction motion during the first 6 days of therapy, when used as a subsequent offset, reduced acceptable AP planning target volume margins by 50%. Conclusion: The MV CBCT is a practical direct method of daily localization that shows significant interfraction motion with respect to conventional three-dimensional conformal and intensity-modulated radiotherapy margins, similar to that measured in other modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual Motion and Duty Time in Respiratory Gating Radiotherapy Using Individualized or Population-Based Windows

Purpose: The efficiency and precision of respiratory gated radiation therapy for tumors is affected by variations in respiration-induced tumor motion. We evaluated the use of individualized and population-based parameters for such treatment. Methods and Materials: External respiratory signal records and images of respiration-induced tumor motion were obtained from 42 patients undergoing respiratory gated radiation therapy for liver tumors. Gating window widths were calculated for each patient, with 2, 4, and 10 mm of residual motion, and the mean was defined as the population-based window width. Residual motions based on population-based and predefined window widths were compared. Duty times based on whole treatment sessions, at various window levels, were calculated. The window level giving the longest duty time was defined as the individualized most efficient level (MEL). MELs were also calculated based on the first 10 breathing cycles. The duty times for population-based MELs (defined as mean MELs) and individualized MELs were compared. Results: Tracks of respiration-induced tumor motion ranged from 3 to 50 mm. Half of the patients had larger actual residual motions than the assigned residual motions. Duty times were greater when based on individualized, rather than population-based, window widths. The MELs established during whole treatment sessions for 2 mm and 4 mm of residual motion gave significantly increased duty times, whereas those calculated using the first 10 breathing cycles showed only marginal increases. Conclusions: Using individualized window widths and levels provided more precise and efficient respiratory gated radiation therapy. However, methods for predicting individualized window levels before treatment remain to be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Electromagnetic Transponder Use to Monitor Inter- and Intrafractional Motion in Locally Advanced Pancreatic Cancer Patients

Purpose: The primary objective of this study was to determine the feasibility of electromagnetic transponder implantation in patients with locally advanced unresectable pancreatic cancer. Secondarily, the use of transponders to monitor inter- and intrafractional motion, and the efficacy of breath holding for limiting target motion, were examined. Methods and Materials: During routine screening laparoscopy, 5 patients without metastatic disease were implanted with transponders peri-tumorally. The Calypso System's localization and tracking modes were used to monitor inter- and intrafractional motion, respectively. Intrafractional motion, with and without breath holding, was also examined using Calypso tracking mode. Results: Transponder implantation was well tolerated in all patients, with minimal migration, aside from 1 patient who expulsed a single transponder. Interfractional motion based on mean shifts from setup using tattoos/orthogonal imaging to transponder based localization from 164 treatments was significant in all dimensions. Mean shift (in millimeters), followed by the standard deviation and p value, were as follows: X-axis: 4.5 mm (1.0, p = 0.01); Y axis: 6.4 mm (1.9, p = 0.03); and Z-axis 3.9 mm (0.6, p = 0.002). Mean intrafractional motion was also found to be significant in all directions: superior, 7.2 mm (0.9, p = 0.01); inferior, 11.9 mm (0.9, p < 0.01); anterior: 4.9 mm (0.5, p = 0.01); posterior, 2.9 mm (0.5, p = 0.02); left, 2.2 mm (0.4, p = 0.02); and right, 3.1 mm (0.6, p = 0.04). Breath holding during treatment significantly decreased tumor motion in all directions. Conclusions: Electromagnetic transponder implantation appears to be safe and effective for monitoring inter- and intrafractional motion. Based on these results a larger clinical trial is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Tracking Method Based on a Deformable 4D CT Breathing Motion Model Driven by an External Surface Surrogate

Purpose: To develop a tumor tracking method based on a surrogate-driven motion model, which provides noninvasive dynamic localization of extracranial targets for the compensation of respiration-induced intrafraction motion in high-precision radiation therapy. Methods and Materials: The proposed approach is based on a patient-specific breathing motion model, derived a priori from 4-dimensional planning computed tomography (CT) images. Model parameters (respiratory baseline, amplitude, and phase) are retrieved and updated at each treatment fraction according to in-room radiography acquisition and optical surface imaging. The baseline parameter is adapted to the interfraction variations obtained from the daily cone beam (CB) CT scan. The respiratory amplitude and phase are extracted from an external breathing surrogate, estimated from the displacement of the patient thoracoabdominal surface, acquired with a noninvasive surface imaging device. The developed method was tested on a database of 7 lung cancer patients, including the synchronized information on internal and external respiratory motion during a CBCT scan. Results: About 30 seconds of simultaneous acquisition of CBCT and optical surface images were analyzed for each patient. The tumor trajectories identified in CBCT projections were used as reference and compared with the target trajectories estimated from surface displacement with the a priori motion model. The resulting absolute differences between the reference and estimated tumor motion along the 2 image dimensions ranged between 0.7 and 2.4 mm; the measured phase shifts did not exceed 7% of the breathing cycle length. Conclusions: We investigated a tumor tracking method that integrates breathing motion information provided by the 4-dimensional planning CT with surface imaging at the time of treatment, representing an alternative approach to point-based external–internal correlation models. Although an in-room radiograph-based assessment of the reliability of the motion model is envisaged, the developed technique does not involve the estimation and continuous update of correlation parameters, thus requiring a less intense use of invasive imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging–Guided versus Surrogate-Based Motion Tracking in Liver Radiation Therapy: A Prospective Comparative Study

Purpose: This study applied automatic feature detection on cine–magnetic resonance imaging (MRI) liver images in order to provide a prospective comparison between MRI-guided and surrogate-based tracking methods for motion-compensated liver radiation therapy. Methods and Materials: In a population of 30 subjects (5 volunteers plus 25 patients), 2 oblique sagittal slices were acquired across the liver at high temporal resolution. An algorithm based on scale invariant feature transform (SIFT) was used to extract and track multiple features throughout the image sequence. The position of abdominal markers was also measured directly from the image series, and the internal motion of each feature was quantified through multiparametric analysis. Surrogate-based tumor tracking with a state-of-the-art external/internal correlation model was simulated. The geometrical tracking error was measured, and its correlation with external motion parameters was also investigated. Finally, the potential gain in tracking accuracy relying on MRI guidance was quantified as a function of the maximum allowed tracking error. Results: An average of 45 features was extracted for each subject across the whole liver. The multi-parametric motion analysis reported relevant inter- and intrasubject variability, highlighting the value of patient-specific and spatially-distributed measurements. Surrogate-based tracking errors (relative to the motion amplitude) were were in the range 7% to 23% (1.02-3.57mm) and were significantly influenced by external motion parameters. The gain of MRI guidance compared to surrogate-based motion tracking was larger than 30% in 50% of the subjects when considering a 1.5-mm tracking error tolerance. Conclusions: Automatic feature detection applied to cine-MRI allows detailed liver motion description to be obtained. Such information was used to quantify the performance of surrogate-based tracking methods and to provide a prospective comparison with respect to MRI-guided radiation therapy, which could support the definition of patient-specific optimal treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Near field fluid coupling between internal motion of the organ of Corti and the basilar membrane

The pressure distribution in each of the fluid chambers of the cochlea can be decomposed into a 1D, or plane wave, component and a near field component, which decays rapidly away from the excitation point. The transverse motion of the basilar membrane, BM, for example, generates both a 1D pressure field, which couples into the slow wave, and a local near field pressure, proportional to the BM acceleration, that generates an added mass on the BM due to the fluid motion. When the organ of Corti, OC, undergoes internal motion, due for example to outer hair cell activity, this motion will not itself generate any 1D pressure if the OC is incompressible and the BM is constrained not to move volumetrically, and so will not directly couple into the slow wave. This motion will, however, generate a near field pressure, proportional to the OC acceleration, which will act on the OC and thus increases its effective mass. The near field pressure due to this OC motion will also act on the BM, generating a force on the BM proportional to the acceleration of the OC, and thus create a “coupling mass” effect. By reciprocity, this coupling mass is the same as that acting on the OC due to the motion of the BM. This near field fluid coupling is initially observed in a finite element model of a slice of the cochlea. These simulations suggest a simple analytical formulation for the fluid coupling, using higher order beam modes across the width of the cochlear partition. It is well known that the added mass due to the near field pressure dominates the overall mass of the BM, and thus significantly affects the micromechanical dynamics. This work not only quantifies the added mass of the OC due its own motion in the fluid, and shows that this is important, but also demonstrates that the coupling mass effect between the BM and OC significantly affects the dynamics of simple micromechanical models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

UBIQUITOUS TORSIONAL MOTIONS IN TYPE II SPICULES

Spicules are long, thin, highly dynamic features that jut out ubiquitously from the solar limb. They dominate the interface between the chromosphere and corona and may provide significant mass and energy to the corona. We use high-quality observations with the Swedish 1 m Solar Telescope to establish that so-called type II spicules are characterized by the simultaneous action of three different types of motion: (1) field-aligned flows of order 50-100 km s{sup -1}, (2) swaying motions of order 15-20 km s{sup -1}, and (3) torsional motions of order 25-30 km s{sup -1}. The first two modes have been studied in detail before, but not the torsional motions. Our analysis of many near-limb and off-limb spectra and narrowband images using multiple spectral lines yields strong evidence that most, if not all, type II spicules undergo large torsional modulation and that these motions, like spicule swaying, represent Alfvenic waves propagating outward at several hundred km s{sup -1}. The combined action of the different motions explains the similar morphology of spicule bushes in the outer red and blue wings of chromospheric lines, and needs to be taken into account when interpreting Doppler motions to derive estimates for field-aligned flows in spicules and determining the Alfvenic wave energy in the solar atmosphere. Our results also suggest that large torsional motion is an ingredient in the production of type II spicules and that spicules play an important role in the transport of helicity through the solar atmosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Mass parameters for relative and neck collective motions in heavy ion fusion reactions

Mass parameters for the relative and neck motions in fusion reactions of symmetric systems {sup 90}Zr+{sup 90}Zr, {sup 110}Pd+{sup 110}Pd, and {sup 138}Ba+{sup 138}Ba are studied by means of a microscopic transport model. The shape of the nuclear system is determined by an equidensity surface obtained from the density distribution of the system. The relative and neck motions are then studied and the mass parameters for these two motions are deduced. The mass parameter for the relative motion is around the reduced mass when the reaction partners are at the separated configuration and increases with a decrease of the distance between two reaction partners after the touching configuration. The mass parameter for the neck motion first decreases slightly up to the touching configuration and then increases with the neck width, and its magnitude is from less than a tenth to several times more than the total mass of the system. The mass parameters obtained from the microscopic transport model are larger than the ones obtained from the hydrodynamic model and smaller than those obtained from the linear response function theory. The mass parameters for both motions depend on the reaction systems, but the one for the relative motion depends on the incompressibility of the EoS more obviously than that for neck motion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of geometric and motion tracking error for awake small animal SPECT

A series of simulation studies were performed to evaluate the effects of geometric and motion tracking errors on reconstruction image quality for a single pinhole collimator awake animal imaging SPECT system. List-mode SPECT data generated using a custom Monte Carlo program that incorporated experimental mouse motion data were reconstructed by MLEM with Siddon's ray tracing. To better understand the impact of motion tracking and system geometric parameter errors on reconstructed system data, an offset of up to 1 mm or degree was separately applied to each for evaluation. In the absence of motion tracking or system geometric error, the applied motion compensation algorithm successfully reconstructed volumes without any degradation or distortion. Presented results reveal that motion tracking errors propagate through the SPECT reconstruction process. However, it is confirmed that the impact of tracking errors in the currently employed motion tracking system, is minimal because of their accuracy. The results also reveal the direct and indirect impact of geometric errors to motion compensated reconstruction quality and that a wrong assumption of pinhole transaxial position produces the most amount of distortion of all the investigated errors. Finally, system geometric errors are shown to have a greater impact on reconstruction quality than equivalent tracking errors.

60 APPLIED LIFE SCIENCES↗