Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microwave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Integrated microwave acousto-optic frequency shifter on thin-film lithium niobate

Electrically driven acousto-optic devices that provide beam deflection and optical frequency shifting have broad applications from pulse synthesis to heterodyne detection. Commercially available acousto-optic modulators are based on bulk materials and consume Watts of radio frequency power. Here, we demonstrate an integrated 3-GHz acousto-optic frequency shifter on thin-film lithium niobate, featuring a carrier suppression over 30 dB. Further, we demonstrate a gigahertz-spaced optical frequency comb featuring more than 200 lines over a 0.6-THz optical bandwidth by recirculating the light in an active frequency shifting loop. Our integrated acousto-optic platform leads to the development of on-chip optical routing, isolation, and microwave signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accelerated microwave-assisted synthesis and in situ X-ray scattering of tungsten-substituted vanadium dioxide (V 1-x W x O 2 )

Vanadium dioxide (VO 2 ) has been widely studied due to its metal-insulator phase transition at 68°C, below which it is a semiconducting monoclinic phase, P2 1 /c, and above it is a metallic tetragonal phase, P4 2 /mnm. Substituting vanadium with transition metals allows transition temperature tunability. An accelerated microwave-assisted synthesis for VO 2 and 5d tungsten substituted VO 2 presented herein decreased synthesis time by three orders of magnitude while maintaining phase purity, particle size, and transition character. Tungsten substitution amount was determined using inductively coupled plasma-optical emission spectroscopy. Differential scanning calorimetry, superconducting quantum interference device measurements, and in-situ heating and cooling experiments monitored through synchrotron x-ray diffraction (XRD) confirmed the transition temperature decreased with increased tungsten substitution. Scanning electron microscopy analyzed through the line-intercept method produced an average particle size of 3 – 5 μm. Average structure and local structure phase purity was determined through Rietveld analysis of synchrotron XRD and least-squares refinement of pair-distribution function data.

36 MATERIALS SCIENCE↗

Integrated Harsh Environment Gas / Temperature Wireless Microwave Acoustic Sensor System for Fossil Energy Applications

There is a significant need for sensors capable of detecting gases, such as H 2 , O 2 , NO x , SO x within harsh environments encountered in power plants, industrial manufacturing, oil and gas exploration, and aerospace applications. This project successfully demonstrated the use of wireless microwave acoustic sensor technology for the detection of gases (H 2 or O 2 ) from ambient temperatures up to 650°C. The work focused on langasite (LGS) based surface acoustic wave resonator (SAWR) sensors as the harsh-environment sensor platform and explored multiple combinations of high-temperature thin films and device structures which were used to increase the sensor platform stability and detection capability at temperatures in the operational range of 150°C to 700°C. Specific material configurations that were investigated include: yttria-stabilized-zirconia (YSZ) decorated with Pt nanoparticles, atomic layer deposited (ALD) Al 2 O 3 , palladium, and Pt/Al 2 O 3 co-deposited electrode alloys. Through the deposition of YSZ at temperatures as high as 850°C and the use of graded alloy concentrations of Pt in the fabrication of the Pt/Al 2 O 3 electrode structures, film stress problems were mitigated, and sensor operation and stability achieved. To test and evaluate SAWR sensor performance for the detection of H 2 and O 2 under the influence of temperature variations, a comprehensive gas sensor control system and test apparatus was created to operate within a laboratory box furnace-controlled environment. In addition to the advancement in thin film materials through the deposition and fabrication techniques mentioned above, the work characterized the performance of sensors containing these films in the presence of oxidizing and reducing gases between 25°C and 700°C. In particular, the work revealed that the exposure of the SAWR sensor surfaces to oxidizing environments significantly improve the sensor response to H 2 , whereas the exposure of the sensor to reducing environments at high temperatures (≈ 500°C) renders the sensor irresponsive to H 2 , requiring sensor surface treatment at high temperatures (above 500°C) to recover the responsiveness to H 2 . The SAWR sensors have been also tested for wireless operation and array operation using multiple orientations to resolve the detection of gases under temperature variations. The work developed at the University of Maine was aided by a collaboration with the NETL Research and Innovation Center, Pittsburgh, PA, where thin film materials and device structures fabricated at UMaine were tested and characterized using NETL gas reactors and surface analysis techniques. SAWR sensors fabricated at UMaine were exposed multiple times to temperatures up to 700°C and H 2 concentrations up to 100% in the NETL facilities to measure the sensor performance. Environetix Technologies Corporation, a UMaine harsh-environment sensor spin-off company, also provided support and assistance in sensor system testing and implementation. The sensor small size and configuration allows flexible sensor placement and embedding of multiple sensor arrays into a variety of components within power systems and other aerospace or industrial settings that need to be interrogated wirelessly. The SAW platform is an attractive option for high-temperature harsh-environment gas sensing applications due to its inherent features, namely small size, capability of battery-free and wireless operation, and cost effective scale production using well-established production techniques from the semiconductor industry. The research findings achieved in this work, particularly advances regarding the fabrication and performance of the SAWR gas sensor platform, can be adapted and transferred to industrial power plants and other harsh environments.

01 COAL, LIGNITE, AND PEAT↗

Analysis of Microwave Resonant Cavity Transducer Degradation Mechanisms

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-efficiency microwave-optical quantum transduction based on a long-coherence-time cavity electro-optic system

We propose a 3D quantum transduction architecture based on a long-coherence-time superconducting cavity coupled to an electro-optic resonator. The 3D hybrid system enables high-efficiency conversion between microwave and optical quantum signals, with potential applications in optical readout of qubits, high-fidelity entanglement generation and high-precision sensing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Microwave Quantum Sensing Capability

The geopolitical world is at the beginning of a quantum renaissance. Technology has reached a level of sophistication that allows the probing of a new world that operates using a different set of rules marked by quantum entanglement, superposition, and the no-cloning theorem. If we can explore this new world and its counterintuitive rules, we may be able to leverage them to build powerful tools for a wide range of applications, including enhanced encryption, computation, and sensing. Some entities have invested early and heavily in exploring this frontier: China has demonstrated quantum teleportation between a ground station and an orbiting satellite; Google recently met a computational milestone known as quantum supremacy, in which a quantum computer solves a problem that would take a classical computer an infeasible amount of time to solve. While great strides have been made, the early progress has caught many entities off guard. The scope of this project leverages an existing investment in a dilution refrigerator strategically chosen to position Pacific Northwest National Laboratory (PNNL) for a future in low-temperature microwave quantum sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave Radiometer — 3-Channel (MWR3C) Instrument Handbook

The microwave radiometer – 3-channel (MWR3C, RPG-LWP-U90) deployed by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility provides time-series measurements of brightness temperatures from three channels centered at 23.834, 30, and 89 GHz. These three channels are sensitive to the presence of liquid water and precipitable water vapor.

47 OTHER INSTRUMENTATION↗

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Frequency-Selectable Laser Source (FLS) for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M.↗

ARM Site E36 - CLAMPS 2 Microwave Radiometer / Processed Data

This dataset contains processed data from the CLAMPS 2 Humidity And Temperature PROfiler (HATPRO) Microwave Radiometer and its associated meteorology tower. CLAMPS 2 deployed during fall-winter 2022 (10/3/22-12/27/23) and summer-fall 2023 (6/16/23-10/1/23).

17 WIND ENERGY↗

NANT Site - Microwave Radiometer Thermodynamic Retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous brightness temperature measurements at 35 channels observed with a microwave radiometer MP3000A operated by NOAA Physical Sciences Laboratory on Nantucket Island for WFIP3. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the MWR housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

NOAA PSL Microwave Radiometer Block Island / Thermodynamic retrievals TROPoe

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous brightness temperature measurements at 35 channels observed with a microwave radiometer MP3000A operated by NOAA Physical Sciences Laboratory on the Block Island for WFIP3. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the MWR housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗