Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Quantitative high dynamic range beam profiling for fluorescence microscopy

Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid Phase Characterization of Tank 241-C-108 Residual Waste Solids Samples

This report presents the results for solid phase characterization (SPC) of solid samples removed from tank 241-C-108 (C-108) on August 12-13,2012, using the off-riser sampler. Samples were received at the 222-S Laboratory on August 13 and were described and photographed. The SPC analyses that were performed include scanning electron microscopy (SEM) using the ASPEX(R)l scanning electron microscope, X-ray diffraction (XRD) using the Rigaku(R) 2 MiniFlex X-ray diffractometer, and polarized light microscopy (PLM) using the Nikon(R) 3 Eclipse Pol optical microscope. The SEM is equipped with an energy dispersive X-ray spectrometer (EDS) to provide chemical information. Gary A. Cooke conducted the SEM analysis, John A. Pestovich performed the XRD analysis, and Dr. Heinz J. Huber performed the PLM examination. The results of these analyses are presented here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-voltage nanodomain writing in He-implanted lithium niobate crystals

A scanning force microscope tip is used to write ferroelectric domains in He-implanted single-crystal lithium niobate and subsequently probe them by piezoresponse force microscopy. Investigation of cross-sections of the samples showed that the buried implanted layer, approx1 mum below the surface, is nonferroelectric and can thus act as a barrier to domain growth. This barrier enabled stable surface domains of <1 mum size to be written in 500 mum thick crystal substrates with voltage pulses of only 10 V applied to the tip.

36 MATERIALS SCIENCE↗

Recent Advances in Analytical Electron Microscopy for Irradiated Materials

Analytical electron microscopy (AEM) in the scanning transmission electron microscope (STEM) has long been a staple of post-irradiation examination (PIE) and materials development campaigns. Recently, new advances in both STEM hardware and post-processing data-analysis software, along with ancillary advances such as in focused ion beam (FIB) sample preparation, has led to exciting advances in the quantity and quality of data that can be obtained. This talk will summarize recent experiments performed at Oak Ridge National Laboratory (ORNL), especially work on neutron-irradiated materials and fuels taking advantage of a newly-installed latest-generation AEM tool in the ORNL irradiated materials laboratories. ORNL installed a new FEI Talos F200X microscope, a 200 keV, high-brightness Schottky emission AEM system optimized for high-speed, high-efficiency X-ray mapping experiments. The F200X features the FEI 'SuperX' four-sector silicon drift detector (SDD) X-ray detector, which provides 0.9 sr solid angle of collection. By combining the high-brightness electron source, latest-generation electron optics, and fast computers and pulse processors, X-ray mapping speed is increased by a factor of 50-100 x compared to the previous-generation instruments. In addition to improvements in hardware, data mining via multivariate statistical analysis (MVSA) allows for maximum insight to the data obtained from the new hardware. MVSA data mining of the X-ray maps allows, for instance, unbiased computational identification of the phases present, and discovery of small phases or precipitates not expected by the human analyst. This talk will present examples of experiments performed using the most modern AEM tools and software. Silicon carbide is a major candidate for next-generation nuclear applications. Nano-infiltration by transient eutectic (NITE) SiC requires low sintering temperatures. X-ray mapping of the NITE structure find pockets of different oxides, such as Zr-Y-oxide, Y-Al-oxide, and yttria. MVSA data mining finds the regions where different oxides are present and indicates that Y additions preferentially wet grain boundaries, where Zr additions are preferentially concentrated at grain triple points. SiC coatings from AGR-I experiment TRISO particles were found to contain significant quantities of fission products (e.g., Pd) as well as actinides (U, Pu). MVSA data mining found complex precipitates and grain boundary films of the fission products and actinides deep (∼several microns) into the SiC layer. Advanced AEM methods, combined with MVSA data mining, makes possible both rapid and detailed PIE. Ferritic alloys, such as accident-tolerant FeCrAl grades, benefit greatly from advanced AEM examination. Neutron-irradiated FeCrAl precipitates the detrimental Cr-rich α' phase. Because the SuperX SDD system has four detectors, it is possible to obtain high X-ray count rates even on a highly tilted specimen, as might be needed to obtain STEM images of dislocation loops. Results on neutron-irradiated FeCrAl indicates that α' size and number density can be obtained by AEM, and MVSA results determine that minor elements (such as Si) has complex radiation-induced segregation behavior at grain boundaries. We have also developed and validated computer models of the AEM experiment, allowing different microstructures' X-ray map results to be simulated for different STEM instruments. This allows X-ray mapping to be more quantitative, such as by estimating what size nanoclusters in an oxide-dispersion strengthened steel would be visible or invisible in STEM. In summary, new advanced AEM technology provides a major leap forward in experiments possible in PIE of irradiated materials. (authors)

36 MATERIALS SCIENCE↗

Understanding polaronic transport in complex oxides by combining precise synthesis and first-principles many-body theory

In complex oxides, charge carriers often couple strongly with lattice vibrations to form polarons–entangled electron–phonon quasiparticles whose transport properties remain difficult to characterize. Experimental access to intrinsic polaronic transport requires ultraclean samples, while theoretical description demands methods beyond low-order perturbation theory. Here, we show a predictive theory–experiment workflow to study polaron transport in complex oxides. Focusing on a prototypical polaronic oxide, anatase TiO 2 , we combine growth of high-quality oxygen-vacancy-doped films using hybrid molecular beam epitaxy with a first-principles electron–phonon diagrammatic Monte-Carlo (FEP-DMC) framework recently developed for accurate polaron predictions. Our films exhibit record-high electron mobility for anatase TiO 2 , in excellent agreement with FEP-DMC calculations conducted prior to experiment, which predict a room-temperature mobility of 45 ± 15 cm −2 V −1 s −1 and a mobility-temperature scaling of μ ∝ T −1.9 ± 0.077 . Microscopic analysis using scanning transmission electron microscopy and x-ray photoelectron spectroscopy reveals the role of oxygen vacancies in modulating transport at lower temperatures. FEP-DMC further provides quantitative insight into polaron formation energy, phonon cloud distribution, lattice distortion around the polaron, and the polaronic contribution to mobility. Together, these results provide a deeper microscopic understanding of large-polaron transport in a complex oxide and provide the blueprint to characterize other polaronic materials.

anatase TiO2↗

Image formation, resolution, and height measurement in scanning ion conductance microscopy

Scanning ion conductance microscopy (SICM) is an emerging tool for the noncontact investigation of biological samples such as live cells. It uses an ion current through the opening of a tapered nanopipette filled with an electrolyte for topography measurements. Despite its successful application to numerous systems no systematic investigation of the image formation process has yet been performed. Here, we use finite element modeling to investigate how the scanning ion conductance microscope images small particles on a planar surface, providing a fundamental characterization of the imaging process. We find that a small particle appears with a height that is only a fraction of its actual height. This has significant consequences for the quantitative interpretation of SICM images. Furthermore, small and low particles are imaged as rings in certain cases. This can cause small, closely spaced particles to appear with a lateral orientation that is rotated by 90 deg. Considering both real space and spatial frequency space we find that a reasonable and useful definition of lateral resolution of SICM is the smallest distance at which two small particles can clearly be resolved from each other in an image. We find that this resolution is approximately equal to three times the inner radius of the pipette tip opening.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone and Microgravity

A silicon crystal growth experiment has been accomplished using the floating-zone technique under microgravity on a sounding rocket (TEXUS 36). Measurements of temperature fluctuations in the silicon melt zone due to time dependent thermocapillary convection (Marangoni convection) and an observation of the microscopic growth rate were simultaneously performed during the experiment. Temperature fluctuations of about 0.5 - 0.7 C with a frequency range < 0.5Hz were detectable. The microscopic growth rate fluctuates considerably around the average growth rate of 1 mm/min: Growth rates up to 3 to 4mm/min, close to zero mm/min, as well as negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. They were characterized by Spreading Resistance measurements and Differential Interference Contrast microscopy. The frequencies of temperature fluctuations, microscopic growth rates, and the dopant inhomogeneities correspond quite well, with main frequencies between 0.1 and 0.3 Hz. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, and the characteristic temperature amplitudes and frequencies. At a position 3.4mm above the interface and 1.4mm inside the melt, equivalent to the sensor tip position in the experiment, temperature fluctuations up to 1.8 C and frequencies ? 0.25Hz were found in the simulations.

Schweizer, Markus↗

Note: Artificial neural networks for the automated analysis of force map data in atomic force microscopy

Force curves recorded with the atomic force microscope on structured samples often show an irregular force versus indentation behavior. An analysis of such curves using standard contact models (e.g., the Sneddon model) would generate inaccurate Young's moduli. A critical inspection of the force curve shape is therefore necessary for estimating the reliability of the generated Young's modulus. We used a trained artificial neural network to automatically recognize curves of “good” and of “bad” quality. This is especially useful for improving the analysis of force maps that consist of a large number of force curves.

42 ENGINEERING↗

Quantitative Phase Imaging with a Scanning Transmission X-Ray Microscope

We obtain quantitative phase reconstructions from differential phase contrast images obtained with a scanning transmission x-ray microscope and 2.5 keV x rays. The theoretical basis of the technique is presented along with measurements and their interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive quantum measurement for low-dose electron microscopy

The resolution of current cryoelectron microscopy of radiation-sensitive specimens is ultimately limited by statistical noise because of the necessarily small number of electrons. To bypass this resolution barrier, we propose an extended in-focus phase-contrast microscopy scheme. The scheme incorporates a pixelwise deformable electrostatic mirror at a plane conjugate to the back focal plane of the objective lens. This setup would extract structural information more efficiently than otherwise and naturally enable generation of phase contrast. We present key concepts regarding microscope operations and estimate the degree of electron dose reduction that should in turn enable a resolution improvement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study on aggregation and electric properties in the micro-region of functionalized dithieno[2, 3-b: 3′, 2′-d]thiophene (DTT) oligomers

Three kinds of 2,5,-diphenyl-dithienol[2, 3-b: 3′, 2′-d]thiophene (DP-DTT), 2,5,-distyryl-dithienol[2, 3-b: 3′, 2′-d]thiophene (DEP-DTT) and 2,5,-thienyl-dithienol[2, 3-b: 3′, 2′-d]thiophene (DET-DTT) micro-region structure and electronic properties were studied. Thin films of these functionalized DTT oligomers were prepared in a one-step drop-casting deposition onto highly oriented pyrolytic graphite substrates. The surface structure of these films was characterized by atomic force microscopy (AFM). Conducting probe atomic force microscope (C-AFM) and Kelvin probe force microscope (KFM) were both used to characterize the electronic transport behavior and surface potential distribution. The substituents of DTT oligomers can greatly affect their aggregation and the hopping conductance mechanism was used to explain the Au-DTTs-HOPG junctions. KFM investigation revealed that these oligomers with different substituents have different highest occupied molecular orbital energy levels. The corresponding theoretical analysis reveals similar result to KFM characterization. The I-V results indicated that the aggregates of molecules were the dominating factor to their micro-region electrical transport.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Permittivity transition from highly positive to negative: Polyimide/carbon nanotube composite's dielectric behavior around percolation threshold

In this report, a series of composite films consisting of polyimide as the matrix and multi-wall carbon nanotubes as the filler (PI/MWCNTs) were prepared in a water-based method with the use of triethylamine. Their dielectric properties were tested under frequency of between 100 Hz and 10 MHz, and it was revealed that the permittivity value behaved interestingly around the percolation threshold (8.01% in volume). The water-based method ensured that fillers had high dispersibility in the matrix before percolation, which led to a relatively high dielectric constant (284.28). However, the overlapping caused by excess MWCNTs created pathways for electrons inside the matrix, turning the permittivity to negative. The former phenomenon was highly congruent with the percolation power law, while the latter could be explained by the Drude Model. AC conductivity was measured for more supportive information. Additionally, scanning electron microscopy and transmission electron microscopy were employed to record MWCNTs' microscopic distribution and morphology at the percolation threshold.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AtomAI framework for deep learning analysis of image and spectroscopy data in electron and scanning probe microscopy

Over the past several decades, electron and scanning probe microscopes have become critical components of condensed matter physics, materials science and chemistry research. At the same time, the infrastructure for establishing a connection between microscopy observations and materials behaviour over a broader parameter space is lacking. In this work, we introduce AtomAI, an open-source software package bridging instrument-specific Python libraries, deep learning and simulation tools into a single ecosystem. AtomAI allows direct applications of deep neural networks for atomic and mesoscopic image segmentation converting image and spectroscopy data into class-based local descriptors for downstream tasks such as statistical and graph analysis. For atomically resolved imaging data, the output is types and positions of atomic species, with an option for subsequent refinement. AtomAI further allows the implementation of a broad range of image and spectrum analysis functions, including invariant variational autoencoders for disentangling structural factors of variation and im2spec type of encoder–decoder models for mapping structure–property relationships. Finally, our framework allows seamless connection to the first principles modelling with a Python interface on the inferred atomic positions.

36 MATERIALS SCIENCE↗

Imaging Single Atoms Using Secondary Electrons with an Aberration-Corrected Electron Microscope

Aberration correction has embarked on a new frontier in electron microscopy by overcoming the limitations of conventional round lenses, providing sub-angstrom-sized probes. However, improvement of spatial resolution using aberration correction so far has been limited to the use of transmitted electrons both in scanning and stationary mode, with an improvement of 20-40%. In contrast, advances in the spatial resolution of scanning electron microscopes (SEMs), which are by far the most widely used instrument for surface imaging at the micrometre-nanometre scale, have been stagnant, despite several recent efforts. Here, we report a new SEM, with aberration correction, able to image single atoms by detecting electrons emerging from its surface as a result of interaction with the small probe. The spatial resolution achieved represents a fourfold improvement over the best-reported resolution in any SEM. Furthermore, we can simultaneously probe the sample through its entire thickness with transmitted electrons. This ability is significant because it permits the selective visualization of bulk atoms and surface ones, beyond a traditional two-dimensional projection in transmission electron microscopy. It has the potential to revolutionize the field of microscopy and imaging, thereby opening the door to a wide range of applications, especially when combined with simultaneous nanoprobe spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thick beryllium coatings by magnetron sputtering

Thick (>150 {micro}m) beryllium coatings are studied as an ablator material of interest for fusion fuel capsules for the National Ignition Facility (NIF). As an added complication, the coatings are deposited on mm-scale spherical substrates, as opposed to flats. DC magnetron sputtering is used because of the relative controllability of the processing temperature and energy of the deposits. We used ultra small angle x-ray spectroscopy (USAXS) to characterize the void fraction and distribution along the spherical surface. We investigated the void structure using a combination focused ion beam (FIB) and scanning electron microscope (SEM), along with transmission electron microscopy (TEM). Our results show a few volume percent of voids and a typical void diameter of less than two hundred nanometers. Understanding how the stresses in the deposited material develop with thickness is important so that we can minimize film cracking and delamination. To that end, an in-situ multiple optical beam stress sensor (MOSS) was used to measure the stress behavior of thick Beryllium coatings on flat substrates as the material was being deposited. We will show how the film stress saturates with thickness and changes with pressure.

42 ENGINEERING↗

Multi-pass transmission electron microscopy

Feynman once asked physicists to build better electron microscopes to be able to watch biology at work. While electron microscopes can now provide atomic resolution, electron beam induced specimen damage precludes high resolution imaging of sensitive materials, such as single proteins or polymers. Here, we use simulations to show that an electron microscope based on a multi-pass measurement protocol enables imaging of single proteins, without averaging structures over multiple images. While we demonstrate the method for particular imaging targets, the approach is broadly applicable and is expected to improve resolution and sensitivity for a range of electron microscopy imaging modalities, including, for example, scanning and spectroscopic techniques. The approach implements a quantum mechanically optimal strategy which under idealized conditions can be considered interaction-free.

47 OTHER INSTRUMENTATION↗

Gas mixing system for imaging of nanomaterials under dynamic environments by environmental transmission electron microscopy

A gas mixing manifold system that is capable of delivering a stable pressure stream of a desired composition of gases into an environmental transmission electron microscope has been developed. The system is designed to provide a stable imaging environment upon changes of either the composition of the gas mixture or upon switching from one gas to another. The design of the system is described and the response of the pressure inside the microscope, the sample temperature, and sample drift in response to flow and composition changes of the system are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗