Mesoscale budgets of heat and moisture in a convective system over the central United States

Mesoscale heat and moisture budget calculations from the April 10-11 AVE-SESAME central U.S. region are calculated in order to diagnose the effect of midlatitude organized convection on its environment. When averaged over an area greater than the observational scale, the noise levels of 5 C/day for the heat budget and 2 g/kg per day for the moisture budget are considerably reduced. The credibility of such area-averaged budget results is indicated by the general agreement obtained between the observed rainfall rate and the vertically integrated heat sources and moisture sinks. The vertical convective heating that is diagnosed from this organized midlatitude convection differs significantly from tropical structures diagnosed on much larger temporal and spatial scales. A time lag of several hours between the moisture convergence and rainfall rate is noted.

Kuo, Y.-H.↗

Mesoscale observations of lightning from Space Shuttle

Motion pictures have been taken at night by astronauts on the space shuttle showing lightning discharge that spread horizontally at speeds of 100,000/msec for distances over 60 km. Tape recordings have been made of the accompanying optical pulses detected with a photocell optical system. The observations show that lightning is often a mesoscale phenomena that can convey large amounts of electric charge to earth from an extensive cloud system via a cloud to ground discharge.

Vonnegut, B.↗

An observational study of a mesoscale area of convection under weak synoptic-scale forcing

This is a case study of a mesoscale area of convection which began at night over western Kansas on September 2, 1982 and lasted until the afternoon of September 3. Evidence from analyses of surface, upper-air radar, and satellite observations suggests that the thunderstorms probably formed in response to the lifting of an elevated layer of conditional instability. The lifting can be attributed qualitatively to quasi-geostrophic ascending motion resulting from a shallow layer of warm advection near 60 kPa. Two possible sources of moisture were midlevel moisture which had been advected around an upstream ridge and a localized area of turbulent transport of water vapor from below. The convective event could not have been forecast with synoptic-scale, mandatory-level analyses alone; it was difficult to explain even with detailed analyses at other levels.

Bluestein, H. B.↗

The accuracy of mesoscale temperature and dewpoint fields retrieved from VAS satellite and conventional surface data

The Visible Infrared Spin-Scan Radiometer (VISSR) Atmospheric Sounder (VAS) is a twelve channel imaging radiometer on the Geostationary Operational Environmental Satellites (GOES). It is pointed out that the instrument is designed to monitor the evolution of tropospheric temperature and moisture fields at mesoscale resolution. Since the numerical qualities of VAS soundings affect their usefulness, a quantitative verification of the absolute and relative accuracy of VAS soundings appears highly desirable. The present investigation is concerned with an objective verification for two VAS case studies. Absolute accuray is measured by comparing the VAS retrievals to the radiosonde values at the network sites. Absolute temperature accuracy is found to be + or - 2 C below 500 mb, while absolute dewpoint accuracy is + or - 2 to + or - 3 C below 850 mb.

Chesters, D.↗

Mesoscale generation of available potential energy in the warm sector of an extratropical cyclone

The generation of available potential energy (APE) was evaluated in the warm sector of an extratropical cyclone containing intense convective activity. Mesoscale rawinsonde data from AVE-SESAME '79 was employed. Parametrization techniques were used for latent and sensible heating components, and variations for the Kuo scheme provided convective latent heat release. Radiative transfer models were used to obtain estimates of infrared and solar processes. The results indicated that solar heating was greater than IR cooling near midday. An extensive low-level cloud deck was the most radiatively active area. Negative generation of APE occurred during most of the period for the SESAME domain as a whole. The leading contributor was convective latent heating located primarily in regions of negative efficiency. Infrared cooling was the only component to consistently produce positive generation. Sensible heating provided an important sink of APE in the low levels during the afternoon.

Fuelberg, H. E.↗

Examples of mesoscale structures and short-term wind variations detected by VHF Doppler radar

The first of three wind profilers planned for operation in central and western Pennsylvania began full-time, high-quality operation during July 1985. It is located about 20 km south-southeast of University Park and operates at 50 MHz. Another 50-MHz radar and a 400-MHz radar are to be installed over the next few months, to complete a mesoscale triangle with sides of 120 to 160 km. During the period since early July, a number of weather systems have passed over the wind profiler. Those accompanied by thunderstorms caused data losses either because the Department computer system lost power or because power went out at the profiler site. A backup power supply and an automatic re-start program will be added to the profiler system to minimize such future losses. Data have normally been averaged over a one-hour period, although there have been some investigations of shorter-period averaging. In each case, preliminary examinations reveal that the profiler winds are indicative of meteorological phenomena. The only occasions of bad or missing data are obtained when airplane noise is occasionally experienced and when the returned power is nearly at the noise level, at the upper few gates, where a consensus wind cannot be determined. Jets streams, clouds, and diurnal variations of winds are discussed.

Forbes, G. S.↗

Wind profiler data in a mesoscale experiment from a meteorological perspective

During May and June of 1985, the Oklahoma-Kansas Preliminary Regional Experiment of STORM-Central (OK PRE-STORM) was carried out, with the major objectives of learning more about mesoscale convective systems (MCSs) and gaining experience in the use of new sensing systems and measurement strategies that will improve the design of STORM-Central. Three 50-MHz wind profilers were employed in a triangular array with sides about 275 km. It is far too soon to report any results of this effort, for it has barely begun. The purpose here is to show some examples of the data, some of the surrounding conventional data, and to discuss some of the issues important to meteorologists in evaluating the contribution of the profiler data. The case of 10 to 11 June 1985, featuring a major squall line system which crossed the dense observing network from northwest to southeast, passing the Liberal site about 2230 GMT/10 June, the McPherson site about 0100 GMT/11 June, and Wichita about 0300 GMT/11 June is discussed. Radar and satellite data show that the system was growing rapidly when it passed Liberal, and was large and mature when it passed through McPherson and Wichita. The radar depiction of the system during this stage is given, with the McPherson site in the intense convective echoes near the leading edge at 01 GMT and in the stratiform precipitation at 03 GMT. The profiler wind data for a 9-hour period encompassing the squall line passage at each site are given.

Zipser, E. J.↗

Response of the mesoscale atmosphere to diabatic heating

A study was initiated to determine the influence of convective latent heat release/diabatic heating on the production of kinetic energy during AVE/SESAME I. The primary focus has been on the relative importance of thermally forced modification of the wind field through thickness and height gradient changes versus inertial-advective effects via the diabatic component of vertical motion. Preliminary results have shown that because of the strong vertical shear over the convective region, ageostrophic response is primarily caused by the latter process. The diagnostic parameterization of convective heating has been extended for use in conjunction with satellite precipitation estimates in data-poor oceanic regions. An initial application was made to a mesoscale convective system embedded in the South Pacific convergence zone. Comparison to the heating field diagnosed as a residual in the thermodynamic equation using the ECMWF III-b analyses showed that the methodology will be useful in explaining the observed heating fields and determining the relative contribution of moist processes to the total diabatic heating. Research activities are now concentrated in the following areas: (1) Determining the sensitivity of vertical heating profiles to partitioning of gridscale versus convective precipitation; (2) assessing the possible effects of incorrect analyzed gridscale vertical motions on residuals in the heat budgets computed with the ECMWF III-b data sets.

Robertson, F. R.↗

Automated mesoscale winds derived from GOES multispectral imagery

An automated technique for extracting mesoscale winds from sequences of GOES visible infrared spin scan radiatiometer (VISSR) image pairs has been developed, tested extensively, and configured for quasi-real time research applications on the Atmospheric Sciences Division's research computing sytem. The entire system of computer codes was successfully vectorized for execution on an array processor resulting in job turnaround in less than 1 hour. An objective quality control system provides much greater than 99 percent accuracy in eliminating questionable wind estimates. Dynamical analysis of cloud wind divergence has revealed temporally consistent convergence centers on the meso-beta scale that are highly correlated with ongoing and future developing convective storms.

Wilson, G. S.↗

Utilization of satellite data in mesoscale modeling of severe weather

The Visible Infrared Spin Scan Radiometer Atmospheric Sounder (VAS) data were used to model the 36 hour cyclogenesis period over the Pacific Ocean. Various combinations of VAS data, conventional radiosonde data, and gridded data from the National Weather Service global analysis were used in successive-correction and variational objective-analysis procedures. The Penn State/NCAR mesoscale model was used to test the impact of the VAS data on a 12 hour forecast of convective precipitation in the midweastern U.S.

Warner, Thomas T.↗

Mesoscale waves as a probe of Jupiter's deep atmosphere

Images from the Voyager north/south mapping sequences were searched for waves. A remarkable class of mesoscale waves was identified, with the following features: (1) the wavetrains are usually aligned zonally, i.e., wavecrests are north-south; (2) the average wavelength is 300 km with a standard deviation of only 20%; (3) the wavetrains are long; (4) the waves occur within 25 degrees of the equator, the bulk being at the equator itself; (5) the waves are centered at the extrema (in latitude) of the zonal flow; and (6) the meridional extent of the waves is typically 1 degree of latitude. These observations are interpreted as evidence of gravity waves propagating vertically within a leaky duct. A three-level model is assumed composed of a stable duct which extends up to the base of the NH3 cloud deck near 600 mb. Above this is a thin wave-trapping region characterized by a Richardson number Ri less than 1/4 and containing a critical level, where the local value of the zonal flow velocity equals the phase speed of the wave. This in turn is overlain by a stable region, representing the tropopause region and stratosphere.

Flaser, F. M.↗

Convective cell development and propagation in a mesoscale convective complex

A case study was made of the mesoscale convective complex (MCC) which occurred over southern Oklahoma and northern Texas on 27 May 1981. This storm moved in an eastsoutheasterly direction and during much of its lifetime was observable by radars at Oklahoma City, Ok. and Stephenville, Tx. It was found that the direction of cell (VIP level 3 or more reflectivity) propagation was somewhat erratic but approximately the same as the system (VIP level 1 reflectivity) movement and the ambient wind. New cells developed along and behind the gust front make it appear that once the MCC is initiated, a synergistic relationship exists between the gust front and the MCC. The relationship between rainfall patterns and amounts and the infrared (IR) temperature field in the satellite imagery were examined. The 210 K isotherm of GOES IR imagery was found to encompass the rain area of the storm. The heaviest rainfall was in the vicinity of the VIP level 3 cells and mostly contained within the 205 K isotherm of GOES IR imagery.

Ahn, Yoo-Shin↗

The impact of data density and data error on the evolution of mesoscale forecast error

The effects of data density and data errors on the accuracy of mesoscale weather forecasts were assessed by simulations of a period in February 1979 when a snowstorm occurred along the U.S. eastern seaboard. The simulations were initiated every 12 hr and the growth of the rms error was tracked as a function of time and varying data densities. A uniform grid of instrumentation separation and perfect boundary conditions were assumed for all the simulations. A bias error representation was defined to account for systematic measurement errors. A brief summary of features of the somewhat complex storm is provided, together with the parameters of the 11 different simulations with high, medium and low data densities. The accuracy of the forecasts were proportional to the data density, although the error decreased for all the simulations over a 24 hr period. The density of the vertical data had a significant impact on the accuracy of the forecast, whereas the horizontal data density did not. Finally, pathways by which errors were transferred among variables were identified.

Warner, T. T.↗

Dynamic and static initialization of a mesoscale model using VAS satellite data

Various mesoscale weather forecast model initialization procedures were tested in seven simulation forecasts for a 12 hr period in July 1981. Attention was given to the impacts of using as input radiosonde data, VISSR Atmospheric Sounder (VAS) data and a combination of VAS and data from a smoothed global analysis. The data were assimilated with successive correction objective analysis procedures. The model had a 60 km horizontal grid-length resolution, 14 layers in the vertical, and accounted for short- and long-wave energy in the surface energy budget but not in the atmosphere. Conventional data were used for the mass and moisture fields. The trials showed that VAS data enhanced the predictions of the temperature and mass variables, while winds were least accurately predicted when VAS data were entered in the initializations. Finally, statically initialized precipitation forecasts from radiosonde and/or VAS data exhibited equal skill.

Beauchamp, J. G.↗

A surface temperature and moisture parameterization for use in mesoscale numerical models

A modified multi-level soil moisture and surface temperature model is presented for use as in defining lower boundary conditions in mesoscale weather models. Account is taken of the hydraulic and thermal diffusion properties of the soil, their variations with soil type, and the mixing ratio at the surface. Techniques are defined for integrating the surface input into the multi-level scheme. Sample simulation runs were performed with the modified model and the original model defined by Pielke, et al. (1977, 1981). The models were applied to regional weather forecasting over soils composed of sand and clay loam. The new form of the model avoided iterations necessary in the earlier version of the model and achieved convergence at reasonable profiles for surface temperature and moisture in regions where the earlier version of the model failed.

Tremback, C. J.↗

Evaluation of cloud shading effects on the generation and modification of mesoscale circulations

This study presents scale analysis and numerical model evaluations of the impact of cloud shading on (1) the development of sea breeze and thermally induced upslope flows and (2) the generation of mesoscale circulations between cloudy areas adjacent to clear areas. Based on the assumption of modifications of solar and longwave radiation which are typical for some overcast conditions, it was found that the reduction in the first type of circulation is significant and most noticeable in the vertical velocities. In the second case, thermally induced circulations in favorable conditions appear to approach the typical intensity of the sea breeze.

Segal, M.↗

Mesoscale ocean eddy measurements by multibeam altimetry

A multibeam microwave radar altimeter concept is numerically simulated to evaluate its capability to remotely sense mesoscale oceanographic features and eddies in particular. The study tests the sensitivity of the sensor to variations of systematic and environmental parameters, including sensor attitude angle, sensor position, and system errors. A novel concept of computing eddy vorticity from the multibeam data is explored. Application of this concept to the detection of simulated ocean eddies in the presence of tracker noise data gives excellent results; the technique is shown to be simple and accurate. The minimum size of the eddy detectable by the multibeam altimeter is presented for a given performance characteristic of the radar.

Lee, H. S.↗

Vertical normal modes of a mesoscale model using a scaled height coordinate

Vertical modes were derived for a version of the Colorado State Regional Atmospheric Mesoscale Modeling System. The impacts of three options for dealing with the upper boundary of the model were studied. The standard model formulation holds pressure constant at a fixed altitude near the model top, and produces a fastest mode with a speed of about 90 m/sec. An alternative formulation, which allows for an external mode, could require recomputation of vertical modes for every surface elevation on the horizontal grid unless the modes are derived in a particular way. These results have bearing on the feasibility of applying vertical mode initialization to models with scaled height coordinates.