Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Nuclear thermal rocket nozzle testing and evaluation program

Performance characteristics of the Nuclear Thermal Rocket can be enhanced through the use of unconventional nozzles as part of the propulsion system. The Nuclear Thermal Rocket nozzle testing and evaluation program being conducted at the NASA Lewis is outlined and the advantages of a plug nozzle are described. A facility description, experimental designs and schematics are given. Results of pretest performance analyses show that high nozzle performance can be attained despite substantial nozzle length reduction through the use of plug nozzles as compared to a convergent-divergent nozzle. Pretest measurement uncertainty analyses indicate that specific impulse values are expected to be within + or - 1.17 pct.

Davidian, Kenneth O.↗

Comparing the results of an analytical model of the no-vent fill process with no-vent fill test results for a 4.96 cubic meters (175 cubic feet) tank

The NASA Lewis Research Center (NASA/LeRC) have been investigating a no-vent fill method for refilling cryogenic storage tanks in low gravity. Analytical modeling based on analyzing the heat transfer of a droplet has successfully represented the process in 0.034 m and 0.142 cubic m commercial dewars using liquid nitrogen and hydrogen. Recently a large tank (4.96 cubic m) was tested with hydrogen. This lightweight tank is representative of spacecraft construction. This paper presents efforts to model the large tank test data. The droplet heat transfer model is found to over predict the tank pressure level when compared to the large tank data. A new model based on equilibrium thermodynamics has been formulated. This new model is compared to the published large scale tank's test results as well as some additional test runs with the same equipment. The results are shown to match the test results within the measurement uncertainty of the test data except for the initial transient wall cooldown where it is conservative (i.e., overpredicts the initial pressure spike found in this time frame).

Taylor, William J.↗

Quasar X-ray spectra revisited

A sample of 45 quasars observed by the IPC on the Einstein satellite is used to reexamine the relationship of the soft X-ray energy index with radio properties and the optical Fe II emission. The tendency for radio-loud quasars to have systematically flatter X-ray energy indices than radio-quiet quasars is confirmed with the soft X-ray excess having negligible effect. There is a tendency for the flatness of the X-ray slope to correlate with radio core dominance for radio-loud quasars, suggesting that a component of the X-ray emission is relativistically beamed. For the radio-quiet quasars, the soft X-ray energy indices with a mean of about 1.0 are consistent with the indices found at higher energies, although steeper than those observed for Seyfert 1 galaxies where the reflection model gives a good fit to the data. The correlation of Fe II emission line strength with X-ray energy index is confirmed for radio-quiet quasars using a subset of 18 objects. The radio-loud quasars show no evidence for a correlation. This relation suggests a connection between the ionizing continuum and line emission from the broad emission-line region (BELR) of radio-quiet quasars, but in the opposite sense to that predicted by current photoionization models. The correlations of X-ray slope with radio core dominance and Fe II equivalent width within the radio-loud and radio-quiet subclasses, respectively, imply that the observed wide range of X-ray energy indices is real rather than due to the large measuring uncertainties for individual objects.

Shastri, P.↗

Lunar phase function effects on spectral ratios used for resource assessment

Groundbased telescopic CCD images of 36 selected locations on the moon were obtained in five 'standard' bandpasses at 12 phase angles ranging from -78 deg to +75 deg to measure phase function effects on the ratio values used to quantify the abundance of TiO2 and qualitatively indicate soil maturity. Consistent with previous studies, we find that the moon is 'bluer' at small phase angles, but that the effect on the ratio values for TiO2 abundance for the phase angles of our data is on the order of the measurement uncertainties throughout the range of abundances found in the mare. The effect is more significant as seen from orbiting spacecraft over a range of selenographic latitude. Spectral ratio images (400/560 and 400/730 nm) were used to map the abundance of TiO2 using the empirical relation found by Charlette et al from analysis of returned lunar soils. Additionally, the 950/560 and 950/730 nm image ratios were used to define the regions of mature mare soil in which the relation is valid. Although the phase function dependence on wavelength was investigated and quantified for small areas and the integrated disc, the effect specifically on TiO2 mapping was not rigorously determined. For consistency and convenience in observing the whole lunar front side, our mapping utilized images taken -15 deg less than alpha less than 15 deg when the moon was fully illuminated from earth; however, this includes the strong opposition peak.

Larson, S. M.↗

Calibration of a helium-cooled infrared spatial radiometer and grating spectrometer

Methods used by the Space Dynamics Laboratory of Utah State University (SDL/USU) to calibrate infrared sensors are described, using the Infrared Background Signature Survey (IBSS) spatial radiometer and grating spectrometer as examples. A calibration equation and a radiometric model are given for each sensor to describe their responsivity in terms of individual radiometric parameters. The calibration equation terms include dark offset, linearity, absolute responsivity, and measurement uncertainty, and the radiometric model domains include spatial, spectral, and temporal domains. A portable calibration facility, designed and fabricated by SDL/USU, provided collimated, extended, diffuse scatter, and Jones sources in a single cryogenic dewar. This multi-function calibrator allowed calibration personnel to complete a full calibration of the IBSS infrared radiometer and spectrometer in two 15-day periods. A calibration data system was developed to control and monitor the calibration facility, and to record and analyze sensor data.

Jacobsen, Larry↗

The latitudinal distribution of ozone to 35 km altitude from ECC ozonesonde observations, 1982-1990

Electrochemical concentration cell (ECC) ozone-sonde observations, made in recent years at ten stations whose locations range from the Arctic to Antarctica, have yielded a self-consistent ozone data base from which mean seasonal and annual latitudinal ozone vertical distributions to 35 km have been derived. Ozone measurement uncertainties are estimated, and results are presented in the Bass-Paur (1985) ozone absorption coefficient scale adopted for use with Dobson ozone spectrophotometers January 1, 1992. The data should be useful for comparison with model calculations of the global distribution of atmospheric ozone, for serving as apriori statistical information in deriving ozone vertical distributions from satellite and Umkehr observations, and for improving the satellite and Umkehr ozone inversion algorithms. Attention is drawn to similar results based on a less comprehensive data set published in Ozone in the Atmosphere, Proceedings of the 1988 Quadrennial Ozone Symposium where errors in data tabulations occurred for three of the stations due to inadvertent transposition of ozone partial pressure and air temperature values.

Komhyr, W. D.↗

Low aspect ratio wing experiment

This test was initiated to provide validation data on low aspect ratio wings at transonic speeds. The test was conducted so that the data obtained would be useful in the validation of codes, and all boundary condition data required would be measured as part of the test. During the conduct of the test, the measured quantities were checked for repeatability, and when the data would not repeat, the cause was tracked down and either eliminated or included in the measurement uncertainty. The accuracy of the data was in the end limited by wall imperfections of the wind tunnel in which the test was run.

Olsen, Mike↗

Metrology: Calibration and measurement processes guidelines

The guide is intended as a resource to aid engineers and systems contracts in the design, implementation, and operation of metrology, calibration, and measurement systems, and to assist NASA personnel in the uniform evaluation of such systems supplied or operated by contractors. Methodologies and techniques acceptable in fulfilling metrology quality requirements for NASA programs are outlined. The measurement process is covered from a high level through more detailed discussions of key elements within the process, Emphasis is given to the flowdown of project requirements to measurement system requirements, then through the activities that will provide measurements with defined quality. In addition, innovations and techniques for error analysis, development of statistical measurement process control, optimization of calibration recall systems, and evaluation of measurement uncertainty are presented.

Castrup, Howard T.↗

Theoretical expectations for bulk flows in large-scale surveys

We calculate the theoretical expectation for the bulk motion of a large-scale survey of the type recently carried out by Lauer and Postman. Included are the effects of survey geometry, errors in the distance measurements, clustering properties of the sample, and different assumed power spectra. We considered the power spectrum calculated from the Infrared Astronomy Satellite (IRAS)-QDOT survey, as well as spectra from hot + cold and standard cold dark matter models. We find that measurement uncertainty, sparse sampling, and clustering can lead to a much larger expectation for the bulk motion of a cluster sample than for the volume as a whole. However, our results suggest that the expected bulk motion is still inconsistent with that reported by Lauer and Postman at the 95%-97% confidence level.

Feldman, Hume A.↗

Summertime partitioning and budget of NO(y) compounds in the troposphere over Alaska and Canada: ABLE 3B

As part of NASA's Arctic Boundary Layer Expedition 3A and 3B field measurement programs, measurements of NO(x), HNO3, PAN, PPN, and NO(y) were made in the middle to lower troposphere over Alaska and Canada during the summers of 1988 and 1990. These measurements are used to assess the degree of closure within the reactive odd nitrogen (N(x)O(y)) budget through the comparison of the values of NO(y) measured with a catalytic convertor to the sum of individually measured NO(y) (i) compounds (i.e., sigmaNO(y)(i) = NO(x) + HNO3 + PAN + PPN). Significant differences were observed between the various study regions. In the lower 6 km of the troposphere over Alaska and the Hudson Bay lowlands of Canada a significant fraction of the NO(y) budget (30 to 60%) could not be accounted for by the measured sigmaNO(y)i. This deficit in the NO(y) budget is about 100 to 200 parts per trillion by volume (pptv) in the lower troposphere (0.15 to 3 km) and about 200 to 400 pptv in the middle free troposphere (3 to 6.2 km). Conversely, the NO(y) budget in the northern Labrador and Quebec regions of Canada is almost totally accounted for within the combined measurement uncertainties of NO(y) and the various NO(y)(i) compounds. A substantial portion of the NO(y) budget's 'missing compounds' appears to be coupled to the photochemical and/or dynamical parameters influencing the tropospheric oxidative potential over these regions. A combination of factors are suggested as the causes for the variability observed in the NO(y) budget. In addition, the apparent stability of compounds represented by the NO(y) budget deficit in the lower-altitude range questions the ability of these compounds to participate as reversible reservoirs for 'active' odd nitrogen and suggest that some portion of the NO(y) budget may consist of relatively unreactive nitrogen-containing compounds.

Sandholm, S.↗

Rayleigh scattering measurements in supersonic facilities

Using a narrow-band, pulsed, ArF excimer laser and a single-intensified CCD camera, planar laser Rayleigh scattering measurements were performed to obtain quantitative density measurements both in the free stream and in a model flow field. These measurements were conducted in the 15-inch, Mach 6 high temperature facility at NASA Langley Research Center. This facility is capable of achieving stagnation temperatures up to 700 K (800 F) over a range of stagnation pressures from 0.35 to 2.07 MPa (50 to 300 psia). The high temperature capability of this facility eliminates the clustering effect observed in earlier Mach 6 studies, and allows quantitative density measurements in the free stream over a range of stagnation pressures from 0.35 to 1.75 MPa (50 to 250 psia). Model flow field measurements were obtained on 38.1 mm diameter cylinder. Measurement locations include the free stream, the region behind the bow shock in front of the model, and the region behind the model including the wake. The densities deduced from the Rayleigh scattering measurements in the model flow field are compared with CFD computations. Measurement uncertainties and the detection limit are discussed.

Shirinzadeh, B.↗

Observations of Radar Backscatter at Ku and C Bands in the Presence of Large Waves during the Surface Wave Dynamics Experiment

Ocean radar backscatter in the presence of large waves is investigated using data acquired with the Jet Propulsion Laboratory NUSCAT radar at Ku band for horizontal and vertical polarizations and the University of Massachusetts CSCAT radar at C band for vertical polarization during the Surface Wave Dynamics Experiment. Off-nadir backscatter data of ocean surfaces were obtained in the presence of large waves with significant wave height up to 5.6 m. In moderate-wind cases, effects of large waves are not detectable within the measurement uncertainty and no noticeable correlation between backscatter coefficients and wave height is found. Under high-wave light-wind conditions, backscatter is enhanced significantly at large incidence angles with a weaker effect at small incidence angles. Backscatter coefficients in the wind speed range under consideration are compared with SASS-2 (Ku band), CMOD3-H1 (C band), and Plant's model results which confirm the experimental observations. Variations of the friction velocity, which can give rise to the observed backscatter behaviors in the presence of large waves, are presented.

Nghiem, S. V.↗

Simultaneous Luminescence Pressure and Temperature Measurement System for Hypersonic Wind Tunnels

Surface pressures and temperatures are determined from visible emission brightness and green-to-red color ratioing of induced luminescence from a ceramic surface with an organic dye coating. A ceramic-dye matrix of porous silica ceramic with an adsorbed dye is developed for high-temperature pressure sensitivity and stability (up to 150 C). Induced luminescence may be excited using a broad range of incident radiation from visible blue light (488-nm wavelength) to the near ultraviolet (365 nm). Ceramic research models and test samples are fabricated using net-form slip-casting and sintering techniques. Methods of preparation and effects of adsorption film thickness on measurement sensitivity are discussed. With the present 8-bit imaging system a 10% pressure measurement uncertainty from 50 to 760 torr is estimated, with an improvement to 5% from 3 to 1500 torr with a 12-bit imaging system.

Buck, Gregory M.↗

Modeling the Performance of Direct-Detection Doppler Lidar Systems in Real Atmospheres

Previous modeling of the performance of spaceborne direct-detection Doppler lidar systems has assumed extremely idealized atmospheric models. Here we develop a technique for modeling the performance of these systems in a more realistic atmosphere, based on actual airborne lidar observations. The resulting atmospheric model contains cloud and aerosol variability that is absent in other simulations of spaceborne Doppler lidar instruments. To produce a realistic simulation of daytime performance, we include solar radiance values that are based on actual measurements and are allowed to vary as the viewing scene changes. Simulations are performed for two types of direct-detection Doppler lidar systems: the double-edge and the multi-channel techniques. Both systems were optimized to measure winds from Rayleigh backscatter at 355 nm. Simulations show that the measurement uncertainty during daytime is degraded by only about 10-20% compared to nighttime performance, provided a proper solar filter is included in the instrument design.

McGill, Matthew J.↗

Multiple Point Dynamic Gas Density Measurements Using Molecular Rayleigh Scattering

A nonintrusive technique for measuring dynamic gas density properties is described. Molecular Rayleigh scattering is used to measure the time-history of gas density simultaneously at eight spatial locations at a 50 kHz sampling rate. The data are analyzed using the Welch method of modified periodograms to reduce measurement uncertainty. Cross-correlations, power spectral density functions, cross-spectral density functions, and coherence functions may be obtained from the data. The technique is demonstrated using low speed co-flowing jets with a heated inner jet.

Seasholtz, Richard↗

SERTS-95 Measurements of Wavelength Shifts in Coronal Emission Lines Across a Solar Active Region

We used slit spectra from the 1995 flight of Goddard Space Flight Center's Solar EUV Rocket Telescope and Spectrograph (SERTS-95) to measure wavelength shifts of coronal emission lines in the core of NOAA active region 7870 relative to its immediate surroundings (its "edge"). This method circumvents the unavailability of reliable laboratory rest wavelengths for the observed lines by using wavelengths from the edge spectrum as references. We derived the, SERTS-95 wavelength calibration from measurements of a post-flight laboratory spectrum containing 28 He II and Ne II EUV standard wavelengths known to high accuracy. Wavelength measurements for lines of He I, Ne III, and additional lines of Ne II in the laboratory calibration spectrum provide more accurate values than were previously available, enabling these lines also to serve as future calibration standards. Six solar lines were chosen for this study, namely, He II at 303.78 A, Fe XII at 193.51 A, Fe XIII at 202.05 A, Fe XIV at 211.33 A, Fe XV at 284.15 A, and Fe XVI at 335.41 A. Because these lines are free from known blends in the SERTS-95 spectra and are either intrinsically strong or near the SERTS-95 peak sensitivity, they are our most reliable lines for measuring relative wavelength shifts in the spatially resolved active region core spectra. The iron ions are the hottest ions ever used for this type of analysis. All six lines reveal statistically significant spatial variations in their measured relative wavelength shifts in the active region core, including mixtures of blueshifts and redshifts (each with maximum values corresponding to relative Doppler velocities approximately 15 km/s), indicating a dynamic, turbulent corona. For each of these lines we calculated weighted-average relative Doppler velocities from the wavelength shifts in the spatially resolved core spectra by weighting the shifts in the individual spatial pixels with their respective measurement uncertainties.

Brosius, Jeffery W.↗

Solar-Cycle Changes in GONG P-Mode Widths and Amplitudes 1995-1998

We search for a solar cycle variation in mode widths and amplitudes derived from 3-month GONG time series. The variation of mode width and amplitude observed in GONG data are the combined effects of fill factor, temporal variation, and measurement uncertainties. The largest variation is caused by the fill factor resulting in modes with increased width and reduced amplitude when fill is lower. We assume that the solar cycle variation is the only other systematic variation beside the temporal window function effect. We correct all currently available data sets for the fill factor and simultaneously derive the solar cycle variation. We find an increase of about 3% on average in mode width from the previous minimum to Oct. 1998 and a decrease of about 7% and 6% in mode amplitude and mode area (width x amplitude). We find no l dependence of the solar-cycle changes. As a function of frequency, these changes show a maximum between 2.7 and 3.3 mHz with about 47% higher than average values for mode width and about 29% and 36% higher ones for mode amplitude and area. We estimate the significance of these rather small changes by a pre-whitening method and find that the results are significant at or above the 99.9% level with mode area showing the highest level of significance and mode width the lowest. The variation in background amplitude is most likely not significant and is consistent with a zero change.

Komm R. W.↗

Two Fiber Optical Fiber Thermometry

An optical fiber thermometer consists of an optical fiber whose sensing tip is given a metallic coating. The sensing tip of the fiber is essentially an isothermal cavity, so the emission from this cavity will be approximately equal to the emission from a blackbody. Temperature readings are obtained by measuring the spectral radiative heat flux at the end of the fiber at two wavelengths. The ratio of these measurements and Planck's Law are used to infer the temperature at the sensing tip. Optical fiber thermometers have high accuracy, excellent long-term stability and are immune to electromagnetic interference. In addition, they can be operated for extended periods without requiring re-calibration. For these reasons. it is desirable to use optical fiber thermometers in environments such as the International Space Station. However, it has recently been shown that temperature readings are corrupted by emission from the fiber when extended portions of the probe are exposed to elevated temperatures. This paper will describe several ways in which the reading from a second fiber can be used to correct the corrupted temperature measurements. The accuracy and sensitivity to measurement uncertainty will be presented for each method.

Jones, Mathew R.↗