Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Pyrolysis-high resolution gas chromatography and pyrolysis gas chromatography-mass spectrometry of kerogens and kerogen precursors

A series of kerogens and kerogen precursors isolated from DSDP samples, oil shales and recent algal mats have been examined by Curie point pyrolysis-high resolution gas chromatography and gas chromatography-mass spectrometry. This study has shown that the three main types of kerogens (marine, terrestrial and mixtures of both) can be characterized using these techniques. The marine (algal) kerogens yield principally aliphatic products and the terrestrial kerogens yield more aromatic and phenolic products with some n-alkanes and n-alkenes. The yields of n-alkanes and n-alkenes increase and phenols decrease with increasing geologic age, however, pyrolysis-GC cannot be used to characterize the influence of short term diagenesis on the kerogen structure.

Van De Meent, D.↗

Understanding Time Dependence on Zinc Metal-Organic Framework Growth Using In Situ Liquid Secondary Ion Mass Spectrometry

The abundance of novel metal-organic framework (MOF) materials continues to increase as more applications are discovered for these highly porous, well-ordered crystalline adsorbents. The simplicity of its constituents allows for the design of new MOFs with virtue of functionality and pore topology towards target adsorbates. However, the fundamental understanding of how these frameworks age during nucleation and growth is mostly limited to speculation from simulation studies. In this effort, we utilize the microfluidic interface of liquid and vacuum in a unique SALVI device to analyze the formation and aging of the benchmark MOF-74 framework using time-of-flight secondary ion mass spectrometry (ToF-SIMS). Principal component analysis (PCA) of the SIMS mass spectra together with ex situ microscopy and porosimetry, provide new insights into the growth and aging process.

Sabale, Sandip R.↗

The gas exchange of hydrogen-adapted algae as followed by mass spectrometry.

The combination of a mass spectrometer inlet and an oxygen electrode in the same vessel permitted continuous recording of the gas exchange of hydrogenase-containing anaerobically adapted algae. In contrast to conventional manometry, the present method made it possible to discern the simultaneous course of reactions involving O2, CO2, and H2. The experiments strongly support the idea of a balance between the photoproduction and photoutilization of H2.

Stuart, T. S.↗

An expert system/ion trap mass spectrometry approach for life support systems monitoring

Efforts to develop sensor and control system technology to monitor air quality for life support have resulted in the development and preliminary testing of a concept based on expert systems and ion trap mass spectrometry (ITMS). An ITMS instrument provides the capability to identify and quantitate a large number of suspected contaminants at trace levels through the use of a variety of multidimensional experiments. An expert system provides specialized knowledge for control, analysis, and decision making. The system is intended for real-time, on-line, autonomous monitoring of air quality. The key characteristics of the system, performance data and analytical capabilities of the ITMS instrument, the design and operation of the expert system, and results from preliminary testing of the system for trace contaminant monitoring are described.

Palmer, Peter T.↗

Molecular Characterization of Organosulfate-Dominated Aerosols over Agricultural Fields from the Southern Great Plains by High-Resolution Mass Spectrometry

The molecular composition of organic aerosols, especially for day/nighttime variations of organosulfates above agricultural fields, is not well understood despite profound impacts on regional climate, crop production, air quality, and human health. Here, nanospray desorption electrospray ionization with high-resolution mass spectrometry (nano-DESI-HRMS) is used to interrogate the molecular composition of organic aerosols collected at the Southern Great Plains, located in an agricultural region of Oklahoma. Identified molecular formulae featured carbon, hydrogen, oxygen (CHO), nitrogen (CHNO), and/or sulfur (CHOS, CHNOS), with higher organosulfate proportions during daytime (41%) compared to nighttime (30%). In this work, nighttime aerosols featured increases in CHO, CHNO, and extremely low volatility organic carbon (ELVOC) species. However, due to high relative humidity, the nighttime aerosols phase state was found to be more liquid-like than daytime aerosols using parametrized glass transition temperatures. Aerosol molecular composition from an anthropogenically influenced plume (southerly winds) showed significant increases in CHOS and ELVOC species. By comparison with chamber studies, CHOS species are suspected to be of mixed biogenic and anthropogenic origin, whereas CHNOS species (not identified in the southerly winds) are suggested to predominately be of biogenic origin. Overall, this study provides key insight into organosulfates above agricultural fields, demonstrating dependence upon day/night cycles and episodic anthropogenic emissions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Transport from Dielectrics to poly-Si/SiOx Passivating Contacts Measured by Mass Spectrometry and Vibrational Spectroscopy

We demonstrate the relationship between Si solar cell passivation and hydrogen content of various passivating films, including hydrogenated amorphous silicon (a-Si:H), aluminum oxide (Al2O3), silicon nitride (SiNx) and combinations thereof. Through isotopic studies using quadrupole mass spectrometry (QMS), Fourier transform infrared spectroscopy (FTIR), and Raman spectroscopy, we determine how hydrogen content and stability within each type of film relates to final passivation quality of solar cell test structures. Si solar cells using polycrystalline silicon on silicon oxide (poly-Si/SiOx) passivating contacts are at the forefront of Si solar cell research and emerging as top performers within industrial production. Performance of passivating contact Si solar cells is largely determined by a parameter known as the open-circuit voltage Voc, which directly relates to material quality within the bulk of the device and at surfaces. High Voc is achieved when defects within the bulk crystalline silicon (c-Si) and at interfaces are passivated, preventing them from acting as charge carrier recombination centers. One of the most important means of passivating defects within Si solar cells is via hydrogenation, injecting the cells with large amounts of H to satisfy dangling bonds in the bulk and at interfaces. Hydrogen is especially important in deactivating a prevalent defect in industrial p-type devices which leads to decreased device performance over long-term exposure to light, called light-induced degradation (LID). Some of the most common materials used to supply H to devices are a-Si:H, Al2O3, and SiNx, which can contain very large amounts of H. Upon annealing at elevated temperatures, the hydrogen becomes mobile enough to find and disable defect sites. However, too much hydrogen can also be problematic, sometimes leading to an effect called light and elevated temperature induced degradation (LeTID). It has been shown that these films passivate the interfaces of poly-Si passivating contacts differently, leading to differing performance. Though Al2O3 is a well-defined dielectric material, SiNx can have many different values of x depending on precursor gases and deposition conditions. We observe different FTIR and Raman spectra from different SiNx over a range of x values films to determine the bonding environments within them and further correlate the relative concentrations of Si, N, and H to the stability of H within SiNx and the passivation performance of each film. Because deuterium is chemically identical to hydrogen within these systems, but gives different signals in FTIR and Raman spectroscopy as well as in QMS, isotopic substitution can be used as an excellent tool to probe the H within films. In addition to measuring the H and D bonding within films using FTIR and Raman spectroscopy, we will use such isotopic experiments to observe H and D movement out of these hydrogenating films at elevated temperatures using QMS to determine the stability of H bonding within such systems. With these films characterized based on elemental composition, we will relate such measurements to passivation quality of these films and combinations thereof on poly-Si/SiOx contact structures using quasi-steady state photoconductance decay measurements to obtain implied open-circuit voltage (iVoc) and saturation current density J0 values. Such investigations into the performance of different passivating films and film stacks will lead to greater understanding of dielectrics in semiconductor devices, further improvements in passivated contact design, and eventually, greater proliferation of renewable solar energy worldwide.

Al2O3↗

Advances in secondary ion mass spectrometry for N-doped niobium

Accurate secondary ion mass spectroscopy measurement of nitrogen in niobium relies on the use of closely equivalent standards, made by ion implantation, to convert nitrogen signal intensity to nitrogen content by determination of relative sensitivity factors (RSFs). Accurate RSF values for ppm-range nitrogen contents are increasingly critical, as more precision is sought in processes for next-generation superconducting radiofrequency (SRF) accelerator cavities. Furthermore, factors influencing RSF value measurements were investigated with the aim of reliably attaining better than 10% accuracy in nitrogen concentrations at various depths into the bulk. This has been accomplished for materials typical of SRF cavities at the cost of increased attention to all aspects.

47 OTHER INSTRUMENTATION↗

Quantitation of amiodarone and N-desethylamiodarone in single HepG2 cells by single-cell printing-liquid vortex capture-mass spectrometry

Quantitative measure of a drug and its associated metabolite(s) with single-cell resolution is often limited by sampling throughput or other compromises that limit broad use. Here, we demonstrate the use of single-cell printing-liquid vortex capture-mass spectrometry (SCP-LVC-MS) to quantitatively measure the intracellular concentrations of amiodarone (AMIO) and its metabolite, N-desethylamiodarone (NDEA), from thousands of single cells across several AMIO incubation concentrations ranging from 0 to 10 μM. Concentrations obtained by SCP-LVC-MS were validated through comparison with average assays and traditional measurement of cells in bulk. Average of SCP-LVC-MS measurements and aggregate vial collection assay the concentrations differed by < 5%. Both AMIO and NDEA had clear log-normal distributions with similar standard deviation of concentrations in the cell population. The mean of both AMIO and NDEA intracellular concentrations were positively correlated with AMIO incubation concentration, increasing from 0.026 to 0.520 and 0.0055 to 0.048 mM for AMIO and NDEA, respectively. The standard deviation of AMIO and NDEA log-normal distribution fits were relatively similar in value across incubation concentrations, 0.15–0.19 log 10 (mM), and exhibited a linear trend with respect to each other. The single cell-resolved conversion ratio of AMIO to NDEA increased with decreasing incubation concentration, 7 ± 2%, 18 ± 3%, and 20 ± 7% for 10.0, 1.0, and 0.1 μM AMIO incubation concentrations, respectively. Finally, association with simultaneously measured lipids had several ions with statistically significant difference in intensity but no clear correlations with AMIO intracellular content was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing Heterogeneous Mixtures of Assembled States of the Tobacco Mosaic Virus Using Charge Detection Mass Spectrometry

The tobacco mosaic viral capsid protein (TMV) is a frequent target for derivatization for myriad applications, including drug delivery, biosensing, and light harvesting. However, solutions of the stacked disk assembly state of TMV are difficult to characterize quantitatively due to their large size and multiple assembled states. Charge detection mass spectrometry (CDMS) addresses the need to characterize heterogeneous populations of large protein complexes in solution quickly and accurately. Using CDMS, previously unobserved assembly states of TMV, including 16-monomer disks and odd-numbered disk stacks, have been characterized. We additionally employed a peptide-protein conjugation reaction in conjunction with CDMS to demonstrate that modified TMV proteins do not redistribute between disks. Finally, this technique was used to discriminate between protein complexes of near-identical mass but different configurations. In conclusion, we have gained a greater understanding of the behavior of TMV, a protein used across a broad variety of fields and applications, in the solution state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volatility Basis Set Distributions and Viscosity of Organic Aerosol Mixtures: Insights from Chemical Characterization Using Temperature-Programmed Desorption–Direct Analysis in Real-Time High-Resolution Mass Spectrometry

Quantitative assessment of gas-particle partitioning of individual components within complex atmospheric organic aerosols (OA) mixtures is critical for predicting and comprehending the formation and evolution of OA particles in the atmosphere. This investigation leverages previously documented data obtained through a temperature programmed desorption - direct analysis in real time – high resolution mass spectrometry (TPD-DART-HRMS) platform. This methodology facilitates the bottom-up construction of volatility basis set (VBS) distributions for constituents found in three biogenic secondary organic aerosol (SOA) mixtures produced through the ozonolysis of a-pinene, limonene, and ocimene. The apparent enthalpies (ΔH*, kJ mol -1 ) and saturated vapor mass concentrations (C T *, µg∙m -3 ) of individual SOA components, determined as a function of temperature (T, K), facilitated an assessment of changes in VBS distributions and gas-particle partitioning with respect to T and atmospheric total organic mass loadings (tOM, µg∙m -3 ). Further, the VBS distributions reveal distinct differences in volatilities among monomers, dimers, and trimers, enabling their categorization into separate volatility bins. At the ambient temperature of T = 298 K, only monomers efficiently partition between gas and particle phases across a broad range of atmospherically relevant total organic mass loadings (tOM) values of 1–100 µg∙m -3 . Partitioning of dimers and trimers becomes notable only at T > 360 K and T > 420 K, respectively. The viscosity of SOA mixtures is assessed using a bottom-up calculation approach, incorporating the input of elemental formulas, ΔH*, C T *, and particle-phase mass fractions of the SOA components. Through this approach, we are able to accurately estimate the variations in SOA viscosity that result from the evaporation of its components. These variations are, in turn, influenced by atmospherically relevant changes in tOM and T. Comparison of the calculated SOA viscosity and diffusivity values with literature reported experimental results shows close agreement, thereby validating the employed calculation approach. These findings underscore the significant potential for TPD-DART-HRMS measurements in enabling the untargeted analysis of organic molecules within OA mixtures. This approach facilitates quantitative assessment of their gas-particle partitioning and allows for the estimation of their viscosity and condensed-phase diffusion, thereby contributing valuable insights to atmospheric models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reactions of atomic thorium and uranium cations with CF 4 studied by guided ion beam tandem mass spectrometry

The fundamental chemistry of the actinides continues to be an area of interest because of their use in nuclear fuel cycles. Here, the kinetic energy dependences of the reactions of thorium and uranium cations with CF 4 were studied using guided ion beam tandem mass spectrometry. The products observed include AnF x + (An = Th or U, x = 1-3) and CF y + (y = 1-3). Although most reactions are exothermic according to literature thermochemistry, all cross sections display strong endothermic features indicating a restriction in the reactivity at low energies. For both actinides, only the AnF + + CF 3 product channel is observed at low energies; however, its formation proceeds very inefficiently. Furthermore, these results indicate that the reactions of Th + and U + with CF 4 are not thermodynamically driven and suggest that the low-energy reactivity results from precise alignment of the reactants.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Top-down mass spectrometry and assigning internal fragments for determining disulfide bond positions in proteins

Disulfide bonds in proteins have a substantial impact on protein structure, stability, and biological activity. Localizing disulfide bonds is critical for understanding protein folding and higher-order structure. Conventional top-down mass spectrometry (TD-MS), where only terminal fragments are assigned for disulfide-intact proteins, can access disulfide information, but suffers from low fragmentation efficiency, thereby limiting sequence coverage. Here, we show that assigning internal fragments generated from TD-MS enhances the sequence coverage of disulfide-intact proteins by 20–60% by returning information from the interior of the protein sequence, which cannot be obtained by terminal fragments alone. Further, the inclusion of internal fragments can extend the sequence information of disulfide-intact proteins to near complete sequence coverage. Importantly, the enhanced sequence information that arise from the assignment of internal fragments can be used to determine the relative position of disulfide bonds and the exact disulfide connectivity between cysteines. The data presented here demonstrates the benefits of incorporating internal fragment analysis into the TD-MS workflow for analyzing disulfide-intact proteins, which would be valuable for characterizing biotherapeutic proteins such as monoclonal antibodies and antibody–drug conjugates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic insight into AnO 2 + bonding from ThH + /UH + reactions studied by inductively coupled plasma tandem mass spectrometry

The bonding mechanisms of actinides have been a focus of fundamental research over the past few decades. In the present study, reactions of the simplest actinide-containing species, ThH + and UH + , with O 2 and CO 2 are investigated by inductively coupled plasma tandem mass spectrometry. The reactions of ThH + and UH + with O 2 are efficient, and the reactions of ThH + and UH + with CO 2 display reduced reaction efficiencies. For both reactions involving CO 2 , ThO 2 + and UO 2 + are observed; however, there is a clear barrier to ThO 2 + formation whereas UO 2 + forms through an exothermic, barrierless process. The experimental observations and available thermodynamic information are used to predict the outcomes of reactions involving the later AnH + . The anticipated reaction enthalpies for Pa–Am display a clear correlation with the promotion energy of An + to a 6d 2 electronic configuration, E p (6d 2 ), although a shift in the slope of the correlation of reaction enthalpies and E p (6d 2 ) suggests that there is likely a change in bonding mechanism that starts with Np + . Similar shifts have also been noted in previous studies. Beginning with Np + , the 6d orbitals become less accessible than they are for the earlier An + as measured by E p (6d 2 ), and this accessibility of the 6d orbitals may drive actinide bonding.

5f orbitals↗

APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY IN THE ANALYSIS OF PLUTONIUM CONTENT OF FAST CRITICAL ASSEMBLY FUEL DISPOSITION

Outline • Fast Critical Assembly (FCA) Plutonium Fuel Disposition • Brief campaign overview • Savannah River National Laboratory • Analytical capabilities and instrumentation • Typical FCA sample analysis process • Plutonium analysis by quadrupole-inductively coupled plasma-mass spectrometry (Q-ICP-MS) • Method description/development • Instrumentation • Data/control charts

Bonilla, Henry J. [Savannah River National Laborat↗

Secondary ion mass spectrometry study of ex situ annealing of epitaxial GaAs grown on Si substrates

Samples of epitaxial GaAs grown on (100) Si substrates using molecular beam epitaxy were annealed at four different temperatures, from 800 to 950 C. Following annealing, the samples were analyzed using secondary ion mass spectrometry. Depth profiles of Ga, As, and Si reveal optimum conditions for annealing, and place a lower limit on a damage threshold for GaAs/Si substrates.

Radhakrishnan, G.↗