Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Management Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Hierarchical Control of Megawatt-Scale Charging Stations for Electric Trucks with Distributed Energy Resources

Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Driving Next-Generation Workflows from the Data Plane

We observe the emergence of a new generation of scientific workflows that process data produced at a sustained rate by scientific instruments and large scale numerical simulations. This data is consumed by multiple analysis, visualization, or Machine Learning components not only to enable inference and justify the scientific program, but also to monitor and steer the evolution of these experiments. In such workflows, moving intermediate data efficiently is key to performance, more than efficiently scheduling computational tasks. However, most traditional workflow management systems focus on optimizing task scheduling and then deal with data management, assuming a “move little, compute for long” model, which makes them unfit to the efficient management of this new generation of workflows. Therefore, we advocate for a new way to manage scientific workflows. We propose to consider an efficiently and independently managed data plane that can store and stream data. Workflows compute components, in the application plane can then interact with the data plane, abstracted from complexities of data management. Then, the role of a workflow management system would become that of a control plane that allows users to connect services together to execute the workflow and manages connections between the application and data planes. In this position paper, we characterize several next-generation workflow motifs and describe how their interaction with the data plane is a challenge to traditional workflow management systems. Then, we express a set of requirements that a workflow management system should meet to efficiently manage next-generation workflows at different scales. Based on these requirements, we expose our vision of driving next-generation workflows from the data plane and list remaining open challenges.

Suter, Fred↗

Human-System Interface Design Review Guidelines

The U.S. Nuclear Regulatory Commission (NRC) staff reviews the human factors engineering (HFE) aspects of nuclear power plants in accordance with the Standard Review Plan (NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition). The Human Factors Engineering Program Review Model (NUREG-0711, Revision 3, issued November 2012) contains detailed design review procedures. As part of the review process, the interfaces between plant personnel and the plant's systems and components are evaluated for conformance with HFE guidelines. This document, Human-System Interface Design Review Guidelines (NUREG-0700, Revision 3), provides the guidelines necessary to perform this evaluation. The review guidelines address the physical and functional characteristics of human-system interfaces (HSIs). Because these guidelines only address the HFE aspects of design and not other related considerations, such as instrumentation and control and structural design, they are referred to as HFE guidelines. In addition to the review of actual HSIs, the NRC staff can use the NUREG-0700 guidelines to evaluate a design-specific HFE guidelines document or style guide. The HFE guidelines are organized into four basic parts, which are divided into sections. Part I contains guidelines for the basic HSI elements: information displays, user-interface interaction and management, and analog displays and controls. These elements are used as building blocks to develop HSI systems to serve specific functions. Part II contains the guidelines for reviewing the following HSI systems: alarm system, safety parameter display system, group-view display system, soft control system, computer-based procedure system, automation system, and communication system. Part III provides guidelines for the review of workstations and workplaces. Part IV provides guidelines for the review of HSI support (i.e., maintainability of digital systems and degraded HSI and instrumentation and control conditions).

42 ENGINEERING↗

Nontargeted vs. Targeted vs. Smart Load Shifting Using Heat Pump Water Heaters

Deployment of CTA-2045–enabled devices is increasing in the U.S. market. These devices allow utilities or third-party aggregators to control appliance energy use in homes, and could also be applied to end uses in small commercial buildings. This study focuses on a field study using CTA-2045–enabled water heaters to shift electric load off the peak and toward periods when renewable resources are more prevalent (e.g., near noon for solar resources and near midnight for wind resources). The following load shifting strategies were compared to understand effects on the aggregate load-shifting capabilities of Heat Pump Water Heaters (HPWHs) and on consumer hot water supply: non-targeted (traditional), targeted (grouped, with different shifting schedules) and “smart” (adaptive control commands). The results of this study show that targeted and smart control strategies yield significantly more load-shifting potential from a population of water heaters than the non-targeted approach without sacrificing hot water supply to occupants. However, as control commands become more aggressive, aggregators may face challenges in meeting consumer hot water demand. Furthermore, the findings and lessons learned can benefit electric utilities and inform updates to manufacturer controls and communications standards. The data collected may also be useful for developing and validating HPWH models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooperative fault management for resilient integration of renewable energy

Cooperative fault management (CFM) is designed herein to control different types of renewable energy resources cooperatively during electrical faults. This paper studies systems with a high penetration of photovoltaic (PV) energy and wind energy. First, CFM leverages power converters of PV farms to boost the ride-through capability of nearby doubly-fed induction generators (DFIGs). By controlling PV farms’ output voltages to change smoothly during both fault initiation and fault clearance, the widely used crowbar in DFIGs is less likely to be activated. Crowbar activation adversely makes DFIGs lose controllability and absorb reactive power. The second contribution is the development of a software-defined CFM controller and a controller in-the-loop demonstration of the real-time performance of this optimization-based CFM. CFM capitalizes on distributed optimization formulation to enable flexibility, plug-and-play, and privacy-preserving. Computation time, however, is a major concern for optimization-based dynamics control. Here, real-time controller-in-the-loop simulation results show optimization-based CFM can output reference values around 60 ms and is quick enough for dynamic control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Autonomous Strategies for Improved Performance and Reliability of Li‐Ion Batteries

Abstract The battery community has devoted significant effort to improve the performance and reliability of Li‐ion batteries through the development of new materials. The integration of autonomous function provides an alternative strategy to further extend performance. Autonomous material systems mimic the ability of biological systems to self‐protect, sense, regulate, and heal in response to damage and other environmental changes. When incorporated in batteries, these materials enable autonomic restoration of battery performance upon degradation, as well as autonomic shutdown or extinguishment in response to thermal runaway. Successful strategies for improving Li‐ion battery performance include controlled release of microencapsulated functional additives and the integration of self‐healing or adaptive interlayers and binders. These methods have been effective for stabilizing the solid electrolyte interface, preventing battery fires, restoring electrode conductivity, and suppressing Li dendrite growth. Challenges and opportunities exist in the further application of autonomous strategies in the battery environment. A greater variety of encapsulated additives with precise triggered‐release are needed to address specific battery degradation mechanisms. Incorporation of self‐healing polymers in solid‐state batteries facilitates improvement in interfacial and mechanical stability. The integration of autonomous strategies with battery management systems potentially enables enhanced control over multiple battery cycling parameters.

Zhao, Lihong↗

Hot, Cold, or Just Right? Using a Wide-View Infrared Biometric Sensor to Improve Occupant Comfort and Reduce Overcooling in Buildings via Closed-loop Control (CRADA Final Report)

This research adds to the understanding of building energy management by fundamentally challenging the long-standing paradigm of controlling an environmental parameter—air temperature—and assuming occupant comfort will follow. The project developed and demonstrated a novel approach that directly senses physiological indicators of human comfort to enable closedloop, human-centric control of heating, ventilation, and air conditioning (HVAC) systems. This work shifts the focus from open-loop environmental control to a closed-loop system that prioritizes the occupants' actual thermal state. The primary benefit to the public is the potential for a simultaneous improvement in the quality of indoor environments, where people spend most of their time, and a significant reduction in national energy consumption. Overcooling, or the overuse of cooling energy in a way that discomforts occupants, wastes approximately 0.5 Quads of primary energy annually in U.S. commercial buildings and creates unproductive indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charge-Based Droop Control Addressing Control Saturation for Low-Inertia Converters

With bulky dc-link capacitors/inductors, traditional voltage-source converters (VSCs) and current-source converters (CSCs) feature a large inertia to facilitate the converter control under large transients. To achieve high power density with reduced cost, low-inertia converters (LICs) featuring significantly reduced dc-link capacitors/inductors have attracted growing attention. However, without bulky dc-link energy buffer, LICs are prone to control saturation under large transients, resulting in undesired oscillation and instability. This issue cannot be managed by traditional proportional-integral based control due to the low inertia. And it will deteriorate when several LICs are connected in series. To address this challenge in LICs, a model-predictive control (MPC) with a computation-inexpensive feed-forward compensation method has been proposed to provide fast dynamic responses. But it would suffer control saturation under larger transients that degrades the control performance. In this article, a charge-based droop control (CDC) is proposed to address this remaining challenge. This paper firstly analyzes the control saturation challenge in LICs by using a tri-port soft-switching solid-state transformer as an example. Next, the operating principle of the proposed CDC are introduced. Two different implementation approaches are discussed in detail. Lastly, the proposed scheme is validated in simulation with a high-fidelity model of hardware prototype. As a result, the proposed CDC eliminated the 2 kHz oscillation and reduced the dc-link ripple and overshoot due to control saturation by 75% and 50%, respectively.

30 DIRECT ENERGY CONVERSION↗

Cyber-Physical Smart Light Control System Integration with Smart Grid using Zigbee

This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Safety and Management Framework to Enable Automated Mobility Districts in Urban Areas

Automated mobility technology is beginning to emerge as a viable means to create sustainable and effective public mobility systems within denser urban environments. Automated mobility districts (AMDs) describe major urban districts or activity centers in which deployments of multiple automated vehicle (AV) transit and ride-hailing fleets are supported to meet public mobility needs. The authors put forward a framework to enable AMDs and their governing and management jurisdictional authorities to manage safety of AV operations based on lessons learned from the last century of automated guideway transit and roadway intersection traffic control systems. The essential concept is that of operational management and safety-critical control of multiple AV fleets using a “system-of-systems” approach to system safety analysis. The safety analysis would focus on safe passage of the AV fleet vehicles through complex roadway intersections and junctions, especially in the presence of other non-automated modes such as pedestrians and manually operated vehicles.

47 OTHER INSTRUMENTATION↗

Thermal management of a high temperature sodium sulphur battery stack

The sodium sulfur battery is an advanced secondary battery with high potential for grid-level storage due to their high energy density, low cost of the reactants, and high open-circuit voltage. However, as the operating temperature of the battery is high (about 300 °C), effective thermal management is required to prevent thermal runaway under high current density operation. Here, to develop efficient thermal management strategies, a detailed, thermo-electrochemical, non-isothermal, distributed dynamic model of a sodium-sulfur battery stack is developed. Models of three thermal management strategies are developed and analyzed in this work: active cooling, passive cooling, and hybrid cooling. The active cooling strategy uses air as the cooling medium whereas, the passive cooling strategy uses a phase change material. In the hybrid cooling strategy, both active and passive cooling strategies are used. Due to the high operating temperature of the sodium sulfur batteries, the rejected heat can be utilized effectively and consequently a high variability in the heat rejection rate may not be acceptable. Performance of these strategies is analyzed under high current density operation by evaluating the variability in the cell temperature during charge/discharge cycles, temperature difference between the cells based on their locations, and variability in the heat rejection rate. The phase change-based hybrid thermal management strategy with an embedded controller maintained the temperature variation within ±/- 2.8 °C. Considering the tradeoff between the capital cost for PCM, fan power requirement, and variability in the heat rejection rate, the optimal quantity of the PCM and the maximum air velocity for the maximum current density of 260 mA/cm 2 (0.55 C-rate) were found be 0.74 g/Wh and 3 m/s, respectively.

25 ENERGY STORAGE↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Discovery, Sharing, and Use of Water Data: Initial Findings and Suggested Future Work

Collaborative management of water resources requires a broad suite of “water data” that extends beyond basic information about water quantity and quality to other related topics such as water infrastructure, aquatic ecosystem health, socioeconomic factors, and power generation. Water data are disparate in nature because they are collected and provided by many entities, and in some cases, remain challenging to access and use. The U.S. Department of Energy’s Water Power Technologies Office initiated a project to characterize relevant categories of water data; describe the current state of accessing, using, and visualizing water data; and outline investigatory pathways for future efforts aimed at improving the discovery, sharing, and use of water data. Input on these topics was solicited from a small but diverse cross section of members of the water resources community. Fourteen broad categories of water data were identified: dams; ecology; flood control; hydroclimatology; hydrography; hydrology; hydropower; management landscape; migratory barriers; recreation and aesthetic importance; socioeconomic; water quality; water availability and use; and weather. Stakeholder perspectives on the accessibility and usability of water data indicate these aspects are affected by a complex set of technical and social factors. However, stakeholders generally agreed that better access to water data can provide a range of benefits to water management, and they stressed the need to generate broad support from water data users and producers. Two investigatory pathways were outlined that, taken together, provide a logical progression toward the goals of the project. The first pathway emphasizes further investigation to better define target audiences and data needs, identify opportunities for collaboration between related efforts, and conduct value demonstration activities to generate further support for improving discovery and access of water data. The second pathway focuses on creating a comprehensive vision for potential solutions that improve the discovery of water data. Several activities that align with the first pathway are suggested for the next phase of the project.

13 HYDRO ENERGY↗

Estimation of General Area Dose Rates During Closure Weld Operations on the DOE Standard Canister Pacific Basin Nuclear Conference 2024

The Department of Energy (DOE) Spent Nuclear Fuel (SNF) Road Ready Demonstration Project is an effort to package DOE-managed SNF for road-ready dry storage. A key operation in this demonstration is performing the closure weld on the DOE Standard Canister after it has been loaded with the SNF. Planning the closure weld operations is ongoing and must consider what parts of the operations (if any) can be done manually and what parts must be done remotely. A key parameter to inform the evolving planning of these operations is the dose rate in the vicinity of the canister and the dose hazard posed to the closure weld operators and collocated workers. This study developed a Monte Carlo N-Particle (MCNP) model of the closure weld operation, which was used to estimate general area dose rates as well as dose rates to the welding location, weld operators, and collocated workers. These estimates provide some insight into the potential radiation exposure hazard for workers during the operations and are a factor to be considered in the ongoing development of designs, technology, processes, and administrative controls for packaging DOE-managed SNF for road-ready dry storage.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Role-Based Access Control Policy for Smart Grid Applications: An Offline Deep Reinforcement Learning Approach

Role-based access control (RBAC) is adopted in the information and communication technology domain for authentication purposes. However, due to a very large number of entities within organizational access control (AC) systems, static RBAC management can be inefficient, costly, and can lead to cybersecurity threats. In this paper, a novel hybrid RBAC model is proposed, based on the principles of offline deep reinforcement learning (RL) and Bayesian belief networks. The considered framework utilizes a fully offline RL agent, which models the behavioral history of users as a Bayesian belief-based trust indicator. Thus, the initial static RBAC policy is improved in a dynamic manner through off-policy learning while guaranteeing compliance of the internal users with the security rules of the system. By deploying our implementation within the smart grid domain and specifically within a Distributed Energy Resources (DER) ecosystem, we provide an end-to-end proof of concept of our model. Finally, detailed analysis and evaluation regarding the offline training phase of the RL agent are provided, while the online deployment of the hybrid RL-based RBAC model into the DER ecosystem highlights its key operation features and salient benefits over traditional RBAC models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Site Controllers for Electrification of Commercial Fleet Vehicles

Electrification of transportation fleets presents a significant challenge for commercial customers. These challenges can be specific to region, weather, operating schedule, charging infrastructure, and other factors. This paper presents the value of integrating a site controller to monitor the health of assets and co-optimize the operation of commercial sites with multiple distributed energy resource technologies and electric vehicle fleets. The tests demonstrate smart-charging and vehicle-to-building uses compared to business-as-usual cases. The secondary objectives of power management for the customer vehicle are optimized by a planning tool (REopt) and integrated using the site controller. Any deviations from the planned dispatch are addressed by the real-time controllers offering tertiary controls, such as energy management, and limiting the reverse power flow (back into the grid). The results indicate that site controllers offer an efficient solution to manage the health of the connected assets and a scalable means to optimize the operations of a commercial customer with electrified transportation fleets.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Demonstration of Intelligent HVAC Load Management With Deep Reinforcement Learning: Real-World Experience of Machine Learning in Demand Control

We report that buildings account for 40% of total primary energy consumption and 30% of all CO 2 emissions worldwide. A large portion of building energy consumption is due to heating, ventilation, and air-conditioning (HVAC) systems. In the summer, for example, more than 50% of a building’s electricity consumption is used for cooling. With proper energy management, buildings can provide load shifting, peak shaving, frequency regulation, and many other demand response services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗