Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Development and testing of a continuous maritime monitor for radionuclide aerosols

Monitoring airborne concentrations of radionuclide activity may provide a timely warning to sea-based assets to avoid contamination from a radioactive plume. The development and testing of an automated aerosol monitoring system that can capture and detect radioactive particulate from marine air is presented. A custom electrostatic precipitator (ESP) was designed to capture particulate onto a reusable collection media. The collection efficiency of the ESP system for radon progeny was determined to be ~23%. A conservative calculation of the minimum detectable concentration of 214 Bi was estimated as 0.3-8 Bq/m 3 . The system was demonstrated in continuous operation, without consumables and limited maintenance, in a marine environment at the PNNL campus in Sequim, Washington. In conclusion, a successful 2-month deployment indicates the feasibility of the approach for continuous maritime monitoring for radionuclide aerosols.

Moore, Michael E. [Pacific Northwest National Labo↗

Multi phenomena melt pool sensor data fusion for enhanced process monitoring of laser powder bed fusion additive manufacturing

Finding actionable trends in laser-based metal additive manufacturing process monitoring data is challenging owing to the diversity and complexity of the underlying physical interactions. A single monitoring solution that captures a particular process phenomenon, such as a photodiode that tracks melt pool intensity, is not alone capable of evaluating process stability or detecting flaw formation with sufficient precision for routine application in industry. In this work, to improve flaw detection performance, we adopted a data fusion approach that captures multiple process phenomena. To demonstrate this, we acquired data from laser powder bed fusion (LPBF) builds of cylindrical specimens produced with different laser spot sizes, emulating defocusing due to process faults such as thermal lensing. The resulting specimens had porosity of varying types and severity, quantified by post-build non-destructive X-ray computed tomography, Archimedes density measurements, and destructive metallographic characterization. During the build, the melt pool state was monitored with two coaxial high-speed video cameras and a temperature field imaging system. Physically intuitive low-level melt pool signatures, such as melt pool temperature, shape and size, and spatter intensity were extracted from this high-dimensional, image-based sensor data. These process signatures were subsequently used as input features in relatively simple machine learning models, such as a support vector machine, which were trained to detect laser defocusing, and in addition, predict porosity type and severity. The results show that the data fusion approach significantly enhanced system performance by reducing the overall false positive rate from ~ 0.1 to ~ 0.001 without sacrificing the true positive rate (~0.90). These results were at par with a black-box, deep machine learning approach (convolutional neural network).

36 MATERIALS SCIENCE↗

Calibration and field deployment of low-cost sensor network to monitor underground pipeline leakage

Recent technological advances in methane detection have improved leak detection and repair. However, current methods to reliably measure methane concentrations rely on expensive instruments or demand significant labor input. There is interest in using affordable methane sensors that are responsive to ppmv level changes in methane concentrations in both urban and rural environments for monitoring underground natural gas pipeline leaks. This is especially relevant for situations where potentially significant leaks cannot be repaired immediately or smaller leaks that require long-term monitoring and further evaluation. In this work, a low-cost sensor unit, equipped with a metal oxide sensor, was designed, built, and calibrated over a wide range of methane concentrations and environmental conditions in preparation for field application. A network of these sensors was then installed at the test site and used to measure methane concentrations at ground level above known sub-surface natural gas emissions which emulated underground gas pipeline leaks. This low-cost sensor network measured over 4 days total for the two different known leakage rates. Results demonstrate that the sensors can continuously measure relative methane variability for extended periods but require calibration for a wide range of temperature and humidity conditions to properly determine absolute gas (i.e., methane) concentrations. Furthermore, when a regression analysis was conducted to evaluate the effects of meteorological parameters on methane concentration, air temperature and wind speed have strong impacts on the concentration. Overall, the network approach allows improved identification of leak location and monitoring of underground natural gas leaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ ATR-IR monitoring of hydrothermal carbonation of wollastonite

In-situ reaction monitoring allows for the development of reaction models for hydrothermal carbonation reactions, which have recently gained attention due to their importance in CO 2 sequestration and utilization. Here, we measured the carbonation kinetics of wollastonite (β- CaSiO 3 ) powder compacts under hydrothermal conditions (90°C and 2.4atm) with the help of optical fiber-based attenuated total reflectance infrared spectroscopy (ATR-IR). Further, the fiber probe was positioned at the target area to study the reaction chemistry at the desired region of the powder compact. Absorbances of solid reactants and products were monitored throughout the entire reaction in the 1000–1600cm -1 spectral range. ATR-IR enabled the detection of amorphous silica, which allowed all solid reactants (β-CaSiO 3 ) and products (CaCO 3 and SiO 2 ) to be monitored independently and simultaneously. A linear proportionality constant between absorbance and CaCO 3 phase concentration was determined and used to construct a reaction kinetics profile for carbonate formation, which revealed a rapid reaction onset, followed by two distinct slower decaying regimes.

42 ENGINEERING↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman Spectroscopic In Situ Monitoring of Highly Turbid Media

The ability to run chemical processing more efficiently and cost effectively is a need that spans critical materials recovery and legacy nuclear waste cleanup. Sensors integrated to provide online monitoring are essential to addressing this need by providing near-real time feedback on process conditions, which can improve efficiency, aid in decision making, and reduce the need for grab sample measurements. Optical spectroscopy is well-suited for providing online chemical composition information and has been widely applied in varied chemical systems. However, applications in turbid matrices continue to represent substantial challenges to sensor performance, where absorption or scattering of excitation light can cause significant signal interference. Here, in this study, close-focus Raman probes are investigated for use in turbid media as a way to overcome the signal loss from the scattering of the Raman excitation source. This, paired with advanced data science techniques, allowed for the development of chemometric models for the accurate quantification of several analytes of interest (NO 3 – , NO 2 – , and PO 4 3– ) in highly turbid solutions with solids loadings of up to 20 wt %. This work focuses on offline sample measurement and characterization as an initial step toward the development of online monitoring capabilities. Chemical systems of interest were focused on nuclear waste at the Hanford Site, which represents highly complex matrices that could realize significant processing benefits through the integration of online monitoring.

Felmy, Heather M. [Pacific Northwest National Labo↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Economic Analysis of Condition-Monitoring-Based Predictive Maintenance in Power Plants under Market Elasticity

Condition-monitoring-based predictive maintenance can increase the power plant availability by preventing forced outages. However, the actual on-stream time depends on market elasticity and dynamics, which are affected by cost and penetration of other power generation technologies. This paper develops a systematic approach for the economic analysis of investment in condition monitoring technologies with due consideration of market elasticity. Focus is on corrosion monitoring in coal-fired power plants (CFFPs) since corrosion in high-temperature coal-fired boilers is a leading cause of equipment failure. Investment in sensor networks for measuring corrosion and operating conditions like metal temperature and concentrations of O 2 and SO 2 is investigated. The unscented Kalman filter is used to estimate corrosion in the waterwall section of the boiler under multiple sensor networks. Electricity produced by CFPPs in the future in the U.S. due to changes in availability under market elasticity is studied. Sensitivity of the incremental net present value to factors like the number, type, and cost of sensors is analyzed.

Electrochemistry↗

Spectroscopic Online Monitoring: Using a Multi-Track Visible Spectrometer to Facilitate a Mass Balance Study in a Simulated TALSPEAK Process

Nuclear energy is a promising low-carbon energy candidate to meet the increased demand for green energy, where the integration of fuel recycling can have significant benefits for material usage and waste reduction. Utilizing in situ monitoring tools can provide ample opportunities to better control and safeguard nuclear material recycle processes while also offering knowledge and insight into real-time solution properties. The simultaneous measurement of analytical targets in multiple process locations can enable real-time mass balance and material accountancy calculations. This is demonstrated here with a mass balance study of Nd 3+ on countercurrent aqueous/organic metal extraction within a single centrifugal contactor. The Nd 3+ concentration was simultaneously monitored at the inlets and outlets of both aqueous and organic phases using a visible absorbance detector that allowed for the simultaneous measurement of up to six locations. The Nd 3+ concentration was calculated by using chemical data science algorithms, where model training sets were collected on a single track of the detector. The discussion includes addressing the challenges of using a model collected on a single track and applying it as a model across the other tracks on the detector. Each track of the detector corresponds to one measurement location on the contactor. The difference in the integrated moles of Nd 3+ between the inlet and outlet at the end of the experiment was near zero, indicating that the mass balance of this experiment was maintained. Overall, the online spectroscopic monitoring was able to follow changing solution conditions and accurately measure the concentration of Nd 3+ in different locations within the contactor system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)–Solid-State Ion-Selective Electrodes (S-ISEs)

Long-term accurate and continuous monitoring of nitrate (NO 3 – ) concentration in wastewater and groundwater is critical for determining treatment efficiency and tracking contaminant transport. Current nitrate monitoring technologies, including colorimetric, chromatographic, biometric, and electrochemical sensors, are not feasible for continuous monitoring. In this work, we addressed this challenge by modifying NO 3 – solid-state ion-selective electrodes (S-ISEs) with poly(tetrafluoroethylene) (PTFE, (C 2 F 4 ) n ). The PTFE-loaded S-ISE membrane polymer matrix reduces water layer formation between the membrane and electrode/solid contact, while paradoxically, the even more hydrophobic PTFE-loaded S-ISE membrane prevents bacterial attachment despite the opposite approach of hydrophilic modifications in other antifouling sensor designs. Specifically, an optimal ratio of 5% PTFE in the S-ISE polymer matrix was determined by a series of characterization tests in real wastewater. Five percent of PTFE alleviated biofouling to the sensor surface by enhancing the negative charge (–4.5 to –45.8 mV) and lowering surface roughness (Ra: 0.56 ± 0.02 nm). It simultaneously mitigated water layer formation between the membrane and electrode by increasing hydrophobicity (contact angle: 104°) and membrane adhesion and thus minimized the reading (mV) drift in the baseline sensitivity (“data drifting”). Long-term accuracy and durability of 5% PTFE-loaded NO 3 – S-ISEs were well demonstrated in real wastewater over 20 days, an improvement over commercial sensor longevity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global Prompt Proton Sensor Network: Monitoring Solar Energetic Protons Based on GPS Satellite Constellation

Energetic particle instruments on board Global Positioning System (GPS) satellites form a powerful global prompt proton sensor network (GPPSn) that provides an unprecedented opportunity to monitor and characterize solar energetic protons targeting the Earth. The medium-Earth orbits of the GPS constellation have the unique advantage of allowing solar energetic protons to be simultaneously measured from multiple points in both open- and closed-field line regions. Examining two example intervals of solar proton events, we showcase in this study how GPS proton data are prepared, calibrated, and utilized to reveal important features of solar protons, including their source, acceleration/scattering by interplanetary shocks, the relative position of Earth when impinged by these shocks, the shape of solar particle fronts, the access of solar protons inside the dynamic geomagnetic field, and temporally varying proton distributions in both energy and space. By comparing to Van Allen Probes data, GPS proton observations are further demonstrated not only to be useful for qualitatively monitoring the dynamics of solar protons but also for quantitative scientific research including determining cutoff L-shells. Finally, our results establish that this GPPSn can join forces with other existing solar proton monitors and contribute to observing, warning, understanding, and ultimately forecasting the incoming solar energetic proton events.

47 OTHER INSTRUMENTATION↗

Inversion of Time-Lapse Seismic Reservoir Monitoring Data Using CycleGAN: A Deep Learning-Based Approach for Estimating Dynamic Reservoir Property Changes

Carbon capture and storage is being pursued globally as a geoengineering measure for reducing the emission of anthropogenic CO 2 the atmosphere. Comprehensive monitoring, verification, and accounting programs must be established for demonstrating the safe storage of injected CO 2 . One of the most commonly deployed monitoring techniques is time-lapse seismic reservoir monitoring (also known as 4-D seismic), which involves comparing 3-D seismic survey data taken at the same study site but over different times. Analyses of 4-D seismic data volumes can help improve the quality of storage reservoir characterization, track the movement of injected CO 2 plume, and identify potential CO 2 spillover/leakage from the storage reservoirblue. However, the derivation of high-resolution CO 2 saturation maps from 4-D seismic data is a highly nonlinear and ill-posed inverse problem, often requiring significant computational effort. In this research, we apply a physics-based deep learning method to facilitate the solution of both the forward and inverse problems in seismic inversion while honoring physical constraints. A cycle generative adversarial neural network (CycleGAN) model is trained to learn the bidirectional functional mappings between the reservoir dynamic property changes and seismic attribute changes, such that both forward and inverse solutions can be obtained efficiently from the trained model. We show that our CycleGAN-based approach not only improves the reliability of 4-D seismic inversion but also expedites the quantitative interpretation. Our deep learning-based workflow is generic and can be readily used for reservoir characterization and reservoir model updates involving the use of 4-D seismic data.

58 GEOSCIENCES↗

Challenges and Capabilities in Estimating Snow Mass Intercepted in Conifer Canopies With Tree Sway Monitoring

Snowpack accumulation in forested watersheds depends on the amount of snow intercepted in the canopy and its partitioning into sublimation, unloading, and melt. A lack of canopy snow measurements limits our ability to evaluate models that simulate canopy processes and predict snowpack. We tested whether monitoring changes in wind-induced tree sway is a viable technique for detecting snow interception and quantifying canopy snow water equivalent (SWE). Over a 6 year period in Colorado, we monitored hourly sway of two conifers, each instrumented with an accelerometer sampling at 12 Hz. We developed an approach to distinguish changes in sway frequency due to thermal effects on tree rigidity versus intercepted snow mass. Over 60% of days with canopy snow had a sway signal that could not be distinguished from thermal effects. However, larger changes in tree sway could not generally be attributed to thermal effects, and canopy snow was present 93%–95% of the time, as confirmed with classified PhenoCam imagery. Using sway tests, we converted changes in sway to canopy SWE, which were correlated with total snowstorm amounts from a nearby SNOTEL site (Spearman r = 0.72 to 0.80, p < 0.001). Greater canopy SWE was associated with storm temperatures between -7°C and 0°C and wind speeds less than 4 m s -1 . Lower canopy SWE prevailed in storms with lower temperatures and higher wind speeds. Monitoring tree sway is a viable approach for quantifying canopy SWE, but challenges remain in converting changes in sway to mass and distinguishing thermal and snow mass effects on tree sway.

54 ENVIRONMENTAL SCIENCES↗

Emergent Trends Complicate the Interpretation of the United States Drought Monitor (USDM)

Abstract Effective drought management must be informed by an understanding of whether and how current drought monitoring and assessment practices represent underlying nonstationary climate conditions, either naturally occurring or forced by climate change. Here we investigate the emerging climatology and associated trends in drought classes defined by the United States Drought Monitor (USDM), a weekly product that, since 2000, has been used to inform drought management in the United States. The USDM classifies drought intensity based in part on threshold percentiles in key hydroclimate quantities. Here we assess how those USDM‐defined drought threshold percentiles have changed over the last 23 years, examining precipitation, runoff, soil moisture (SM), terrestrial water storage (TWS), vapor pressure deficit (VPD), and near‐surface air temperature. We also assess underlying trends in the frequency of drought classifications across the U.S. Our analysis suggests that the frequency of drought class occurrence is exceeding the threshold percentiles defined by the USDM in a number of regions in the United States, particularly in the American West, where the last 23 years have emerged as a prolonged dry period. These trends are also reflected in percentile‐based thresholds in precipitation, runoff, SM, TWS, VPD, and temperature. Our results emphasize that while the USDM appears to be accurately reflecting observed nonstationarity in the physical climate, such trends raise critical questions about whether and how drought diagnosis, classification, and monitoring should address long‐term intervals of wet and dry periods or trends.

Geology↗

Monitoring Fracture Hydromechanical Evolution in the Lab and Field Using Unsupervised Metric Learning

Fractures evolve in time through thermal‐hydraulic‐mechanical‐chemical (THMC) processes that alter their long‐range hydraulic transport properties and modify subsurface behavior and activities. The location of subsurface fractures makes it necessary to use remote sensing techniques such as passive or active seismic monitoring for fracture characterization. In this paper, we develop a machine learning approach to monitor the evolution of fracture properties using passive seismic sources in a laboratory setting and using active seismic monitoring from the Sanford Underground Research Facility in Lead, South Dakota, at a depth of 1.25 km in amphibolite rock during stimulation of natural fractures as well as during induced fracturing. The unsupervised metric learning technique applies tandem neural networks (twin (Siamese) or triplet) with contrastive loss and adaptive margins to track slowly varying systems for which class or similarity labels are not available. The approach adopts locality‐sensitive hashing to divide time‐ordered contiguous data into an arbitrary number of pseudo‐classes. Contrastive‐loss training with many hash bins generates an evolving latent‐space trajectory. This approach enables unsupervised metric learning for seismic data stacks under the condition of contiguous state sampling and slowly varying fracture properties. The displacement discontinuity theory provides a mechanistic foundation for the fracture‐dependent trajectories that are related to relaxation of fractures with time‐dependent specific stiffness responding to changes in stress or fluid saturation.

02 PETROLEUM↗

In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic

Abstract This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters ranging from 0.79 to 3.18 mm. It is then demonstrated in a custom drop-on-demand liquid metal jetting system where effective droplet diameters ranging from 0.8 to 1.6 mm are detected. Experimental results demonstrate that this approach can provide information about droplet size, timing, and motion by monitoring a single parameter, the reflection coefficient amplitude at the input port. These results show the promise of the impedance diagnostic as a reliable in-situ characterization method for metal droplets in an advanced manufacturing system.

42 ENGINEERING↗

CO 2 rock physics modeling for reliable monitoring of geologic carbon storage

Monitoring, verification, and accounting (MVA) are crucial to ensure safe and long-term geologic carbon storage. Seismic monitoring is a key MVA technique that utilizes seismic data to infer elastic properties of CO 2 -saturated rocks. Reliable accounting of CO 2 in subsurface storage reservoirs and potential leakage zones requires an accurate rock physics model. However, the widely used CO 2 rock physics model based on the conventional Biot-Gassmann equation can substantially underestimate the influence of CO 2 saturation on seismic waves, leading to inaccurate accounting. We develop an accurate CO 2 rock physics model by accounting for both effects of the stress dependence of seismic velocities in porous rocks and CO 2 weakening on the rock framework. We validate our CO 2 rock physics model using the Kimberlina-1.2 model (a previously proposed geologic carbon storage site in California) and create time-lapse elastic property models with our new rock physics method. We compare the results with those obtained using the conventional Biot-Gassmann equation. Our innovative approach produces larger changes in elastic properties than the Biot-Gassmann results. Using our CO 2 rock physics model can replicate shear-wave speed reductions observed in the laboratory. Our rock physics model enhances the accuracy of time-lapse elastic-wave modeling and enables reliable CO 2 accounting using seismic monitoring.

58 GEOSCIENCES↗

Condition monitoring of permanent magnet AC machines for all-electric transportation systems: State of the art

The current state of the art on emerging and efficient techniques for condition monitoring of permanent magnet (PM) alternating-current (AC) machines deployed in electric vehicle (EV) applications is presented. The discussion includes the most common and specific types of faults in PM motors, such as rotor demagnetisation and stator inter-turn faults, respectively. Fault indicators, such as voltage (v s ) and current (i s ) signals and machine signatures based on motor back electromotive force (EMF) (E B ) and magnetic flux (φ), are taken into account as a measuring quantity in diagnosing motor faults. Other signatures, including thermal analysis, acoustic noise, and vibrations, are also illustrated as some of the emerging techniques in estimating the performance of EV motors while under operations. In addition, various fault modelling methods, condition monitoring techniques, and comprehensive approaches applied in diagnosing the effect of machine faults during its incipient stages are illustrated. Since most of the fault diagnostic techniques discussed here include only machine-based quantities as fault indices/indicators, the provided solutions are therefore found to be more reliable and accurate for diagnosing the motor faults. This comprehensive review study is inclusive of the existing fault diagnostic techniques, which are currently employed in industrial and commercial practices, in addition to the new methodologies proposed by the authors. All the given condition monitoring schemes therefore seem significantly vital in estimating the state of health of PM AC machines while under operation in all-electric transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗