Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Supporting Crew Medical Decisions on Deep Space Missions: A Real-Time Performance Monitoring

Crewed missions into deep space will require astronauts to respond autonomously to safety- and time-critical anomalies. These and other potential issues will require the continuous monitoring and recognition of potentially subtle, but complex, anomalous data patterns. NASA continues to investigate real-time metrics for Extravehicular Operations1 and for providing feedback to improve performance2. Since it is unknown how long-term exposure to deep space will affect crew health, continuous monitoring of clinical and subclinical status is warranted. NASA is characterizing crew medical decision-support needs and identifying the recommended requirements of a Clinical Decision Support System (CDSS) within the Exploration Medical Capability Element (ExMC) of the Human Research Program3. Early detection, and continuous monitoring, of performance may provide an effective prognostic capability for assessing crew health state, and the identified requirements could be provided for an in-vehicle CDSS that acts as an assistant for delivering optimal health and performance and medical care during exploration missions. There is evidence to suggest that automatic, unobtrusive collection of keystroke features, such as alphanumeric key latencies, backspaces or typing rhythm, could be a valuable performance screening tool. Keystroke features show significant differences between control subjects and patients with overt clinical illness, such as multiple sclerosis4 and Parkinson’s disease5, as well as behavioral health and performance issues, such as mild cognitive impairment6 and depression7. This work is exploring a capability for the assessment of early task performance decline in crew as they perform daily activities. Timestamped keyboard entries are continuously collected and stored. Nominal keystroke interactions are compared to those obtained after exposure to spaceflight stressors, e.g., fatigue, to determine the methods sensitivity. This work will pave the way toward an objective detection tool that may be deployed in a spaceflight setting.

clinical↗

UASs Optimization - An evaluation of multiple mode vehicles in monitoring and communication

This presentation will describe the author's experience as Co-I in the NASA/USFS Project: "Strategic Tac Radio and Tac Overwatch (STRATO): Last Mile Communications and Realtime Observation Stratospheric Platforms for wildland fire". This project utilizes an uncrewed Stratospheric (> 70Kft) lighter than air Uninhabited Aerial System (UAS), carries 50 Kg of sensor and communications equipment, and remains on station over a wildfire for up to 30 days. The air vehicle is capable of in excess of 180 days on station, but while the full duration capabilities were not utilized in this project, they could, and would, be used in monitoring a feature like a volcano. In addition to duration, the ability of these Stratospheric Platforms to persistently monitor an area, while carrying "smart" sensors - generating information products, rather than just data - is game changing. Utilizing technologies such as LoRa, the platform can now be the nexus of an ad-hoc sensor web, receiving LoRa based data from low power in-situ sensors in the area being monitored, combining it with high fidelity information gained from on-board sensors, and sending the information product to a remote research facility, using Satellite communication, in real time. The author will relate the evolution of information collection, derivation and delivery mechanisms in the entire range of NASA's UAS fleet, to today's world, where information products conventionally derived in desk top computational environments, and made available to the Science Community in weeks or months, are now being generated and delivered in near real time.

UASs↗

Contractors Road Heavy Equipment Area (SWMU 055) 2022 Annual Groundwater Monitoring Report

This document presents a summary of activities completed at the Contractors Road Heavy Equipment (CRHE) Area, located at Kennedy Space Center (KSC), Florida, from June through December 2022. The activities conducted at the CRHE Area include: - Annual groundwater sampling activities associated with sitewide plume monitoring and Underground Injection Control (UIC) monitoring in the former bioremediation Interim Measures (IM) Hot Spot 1 (HS1) area; - Direct push technology (DPT) groundwater investigation; - Semiannual vapor intrusion (VI) evaluation activities. This facility is designated Solid Waste Management Unit (SWMU) Number 055 (SWMU 055) under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action program. HydroGeoLogic, Inc. (HGL) prepared this report for the National Aeronautics and Space NASA) under contract number 80KSC019F0096/80KSC019D0012, Technical Directive-03. An Advance Data Package (ADP) presentation of the elements of this report received Team (KSCRT) agreement at the April 5, 2023, KSCRT meeting. The chlorinated volatile organic compound plume appears to be stable vertically and horizontally. Additional DPT groundwater sampling will be completed to support a remedial alternatives evaluation for potential means to expedite groundwater cleanup. There are per- and polyfluorinated alkyl substances in site groundwater, and assessment is planned in the future. Sub-slab soil gas monitoring results do not indicate any concerns with indoor vapor intrusion. Based on the 2022 annual groundwater sampling results, it is recommended that annual sampling continue to alternate with the wet and dry season, with the next sampling event planned for December 2023.

groundwater↗

Developmental Hardware Testing Results and Forward Plans for the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H 2 CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H 2 CO at low concentrations with data downlinked. Potential sources of H 2 CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H 2 CO in air is 100 ppb for exposures of 7 days or longer. ISS concentrations of H 2 CO are running only 10 - 30 ppb in the recent several years but have spiked as high as 60 ppb. Gateway real time monitoring requirements for H 2 CO call for a range of 8 - 138 ppb. For this project, a concentration range of 5 - 500 ppb H 2 CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology used for this project was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on TDLS have been demonstrated on ISS, trialed on a nuclear submarine and are being certified as portable Anomaly Gas Analyzers (AGA) for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these devices. The H 2 CO target concentration, however, is low ppb, and a longer wavelength is required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde in air monitor and briefly discuss next steps.

Photoacoustic Formaldehyde Monitor↗

Developmental Hardware Testing Results and Forward Plans for Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Advanced Signal Processing for High Temperatures Health Monitoring of Condensed Water Height in Steam Pipes

An advanced signal processing methodology is being developed to monitor the height of condensed water thru the wall of a steel pipe while operating at temperatures as high as 250deg. Using existing techniques, previous study indicated that, when the water height is low or there is disturbance in the environment, the predicted water height may not be accurate. In recent years, the use of the autocorrelation and envelope techniques in the signal processing has been demonstrated to be a very useful tool for practical applications. In this paper, various signal processing techniques including the auto correlation, Hilbert transform, and the Shannon Energy Envelope methods were studied and implemented to determine the water height in the steam pipe. The results have shown that the developed method provides a good capability for monitoring the height in the regular conditions. An alternative solution for shallow water or no water conditions based on a developed hybrid method based on Hilbert transform (HT) with a high pass filter and using the optimized windowing technique is suggested. Further development of the reported methods would provide a powerful tool for the identification of the disturbances of water height inside the pipe.

health monitoring↗

Monitor assures availability and quality of communication channels

System monitors a communication channel for proper circuit parameters and energizes an alarm if these parameters do not fall within allowable limits. It comprises a monitor-signal transmitter at the transmitting end of the channel and a monitor-signal receiver at the receiving end.

Smith, G. P.↗

Some applications of remote sensing in atmospheric monitoring programs

The applications of remote sensing in atmospheric monitoring programs are described. The organization, operations, and functions of an air quality monitoring network at New Castle County, Delaware is discussed. The data obtained by the air quality monitoring network ground stations and the equipment used to obtain atmospheric data are explained. It is concluded that correlation of the information obtained by the network will make it possible to anticipate air pollution problems in the Chesapeake Bay area before a crisis develops.

Heller, A. N.↗

NASA's contributions to patient monitoring, appendix

Health care problems, and markets for patient monitoring equipment are discussed along with contributions to all phases of patient monitoring, and technology transfer to nonaerospace problems. Health care medical requirements, and NASA achievements in patient monitoring are described, and a summary of the technology transfer is included.

Murray, D. M.↗

Automated monitoring of recovered water quality

Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.

Misselhorn, J. E.↗

Monitoring the vernal advancement and retrogradation (green wave effect) of natural vegetation

The author has identified the following significant results. From the data that have been analyzed thus far, it is apparent that certain parameters of the vegetation (green biomass and vegetation moisture content) are well correlated with ERTS data at some sites, yet the relationship is poor at other locations. The analyses indicate that the green wave development (spring) can be readily detected in the Great Plains Corridor. Consequently, ERTS-1 data provide a new tool for monitoring range readiness on a regional basis. The onset of summer drought and its duration can also be monitored. Data from ten G.P.C. sites suggest that the satellite coverage has been adequate to monitor the status of rangeland vegetation for regional management purposes.

Rouse, J. W., Jr.↗

Life support subsystem monitoring instrumentation

The recognition of the need for instrumentation in manned spacecraft life-support subsystems has increased significantly over the past several years. Of the required control and monitoring instrumentation, this paper will focus on the monitoring instrumentation as applied to life-support subsystems. The initial approach used independent sensors, independent sensor signal conditioning circuitry, and independent logic circuitry to provide shutdown protection only. This monitoring system was replaced with a coordinated series of printed circuit cards, each of which contains all the electronics to service one sensor and provide performance trend information, fault detection and isolation information, and shutdown protection. Finally, a review of sensor and instrumentation problems is presented, and the requirement for sensors with built-in signal conditioning and provisions for in situ calibration is discussed.

Powell, J. D.↗

Performance monitor system functional simulator, environmental data, orbiter 101(HFT)

Information concerning the environment component of the space shuttle performance monitor system simulator (PMSS) and those subsystems operational on the shuttle orbiter 101 used for horizontal flight test (HFT) is provided, along with detailed data for the shuttle performance monitor system (PMS) whose software requirements evolve from three basic PMS functions: (1) fault detection and annunciation; (2) subsystem measurement management; and (3) subsystem configuration management. Information relative to the design and operation of Orbiter systems for HFT is also presented, and the functional paths are identified to the lowest level at which the crew can control the system functions. Measurement requirements are given which are necessary to adequately monitor the health status of the system. PMS process requirements, relative to the measurements which are necessary for fault detection and annunciation of a failed functional path, consist of measurement characteristics, tolerance limits, precondition tests, and correlation measurements.

Parker, F. W.↗

A study of payload specialist station monitor size constraints

Constraints on the CRT display size for the shuttle orbiter cabin are studied. The viewing requirements placed on these monitors were assumed to involve display of imaged scenes providing visual feedback during payload operations and display of alphanumeric characters. Data on target recognition/resolution, target recognition, and range rate detection by human observers were utilized to determine viewing requirements for imaged scenes. Field-of-view and acuity requirements for a variety of payload operations were obtained along with the necessary detection capability in terms of range-to-target size ratios. The monitor size necessary to meet the acuity requirements was established. An empirical test was conducted to determine required recognition sizes for displayed alphanumeric characters. The results of the test were used to determine the number of characters which could be simultaneously displayed based on the recognition size requirements using the proposed monitor size. A CRT display of 20 x 20 cm is recommended. A portion of the display area is used for displaying imaged scenes and the remaining display area is used for alphanumeric characters pertaining to the displayed scene. The entire display is used for the character alone mode.

Kirkpatrick, M., III↗

Battery peak charge voltage monitor for dual air density satellite

A battery peak charge voltage monitor was developed for use on the dual air density satellite (DADS). This device retains a reading of the maximum voltage reached by the spacecraft battery during periods of charging, and makes it available during periods of data transmission. The monitor is connected across the battery and operates solely from the battery; it is powered continuously with quiescent input current of only 3 milliamperes. Standard integrated circuits and a thin-film resistor network are utilized. The monitor occupies approximately 40 square centimeters of a printed-circuit board within a larger electronic package.

Shull, T. A.↗