Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MGI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Modeling radiation loads in the ILC main linac and a novel approach to treat dark current

Electromagnetic and hadron showers generated by electrons of dark current (DC) can represent a significant radiation threat to the ILC linac equipment and personnel. In this study, a commissioning scenario is analysed which is considered as the worst-case scenario for the main linac regarding the DC contribution to the radiation environment in the tunnel. A normal operation scenario is analysed as well. An emphasis is made on radiation load to sensitive electronic equipment—cryogenic thermometers inside the cryomodules. Prompt and residual dose rates in the ILC main linac tunnels were also calculated in these new high-statistics runs. A novel approach was developed—as a part of general purpose Monte Carlo code MARS15—to model generation, acceleration and transport of DC electrons in electromagnetic fields inside SRF cavities. Comparisons were made with a standard approach when a set of pre-calculated DC electron trajectories is used, with a proper normalization, as a source for Monte Carlo modelling. Results of MARS15 Monte Carlo calculations, performed for the current main linac tunnel design, reveal that the peak absorbed dose in the cryogenic thermometers in the main tunnel for 20 years of operation is about 0.8 MGy. The calculated contact residual dose on cryomodules and tunnel walls in the main tunnel for typical irradiation and cooling conditions is 0.1 and 0.01 mSv/hr, respectively.

43 PARTICLE ACCELERATORS↗

Elementary Particle Physics

The UT Dallas High Energy Physics group collaborates on the ATLAS experiment which observes the world’s high energy proton-proton collisions. The UTD group utilized ATLAS 8 TeV Run 1 data to search for evidence of a “dark photon”, a gauge boson outside the “Standard Model of Particle Physics” that theorist hypothesize could mediate a force felt only by the dark matter particles that dominate out universe. The observable signature is a pair of prompt lepton jets. The results of this search were published in 2013. More recently, we have improved the sensitivity of the analysis using machine learning techniques, and we are extending the search to higher and lower mass dark photons using the ATLAS 13 TeV data set. Detection of a new fifth force would represent an important advance beyond the 4 known forces that influence baryonic matter. The LHC Long Shutdown 1 from 2013-2014 was a period of intense work on refurbishment and upgrades for the ATLAS Pixel community and the UTD group. The service quarter panels of the original Pixel detector were replaced, and the Insertable B Layer (IBL) detector was integrated. During IBL integration, UTD participated on the Stave Task Force that solved corrosion problems with IBL wire bonds. We developed a relative humidity sensor that was used during integration and transport to the beamline when detector was unpowered. The sensors were repurposed to monitor relative humidity inside the ID endplates until the built-in sensors were recommissioned. The UTD group worked on the connection of the Pixel and IBL at Point 1 and we were in charge of electric service testing. The IBL wire bond corrosion was the instigation for developing a new conformal coating method using an atomizing spray and Cellpack polyurethane. It is being considered for use in the ITk tracker upgrade. We have demonstrated its tolerance both of a 9 MGy ionizing dose and thermal expansion. Two UTD students are completing authorship qualification projects. One is helping understand variations in impact parameter resolution across different running periods. The second is developing a data-driven method to monitor the fraction of fake tracks in dense jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Management, Efficiency and Treatment of Silica, Chlorides, and other Pollutants (METSiCloPs) of Cooling Tower Water [Slides]

Site-wide water balance suggests that CTs across eight LANL facilities use about 58% of the total potable water bought from LAC (271 MGY). It is vital to make a conscious and calculated effort to reduce the dependence on external water supplies, and potable water.We need to strive to increase CoCs at CTs and improve water efficiency to reduce water consumption.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

METSiCloPs in Cooling Tower Water, Final Presentation: Water Treatment at FSI [Slides]

Motivation: According to current projections, FSI could require anywhere from 83-288 MGY of water. Reducing excessive dependence on external water supply by making operations as water-lean as possible in the face of water availability fluctuations seasonally. The amount of Silica occurring naturally in New Mexico is several multiples higher than most of the country, with average values of 90 ppm, but reaching as high as 113 ppm. Since its saturation concentration at ambient temperatures is about 150 ppm, this corresponds to cycles of concentration as low as 1-2 for untreated water in cooling towers (i.e., the water is circulated through the towers only once or twice before they are dumped into the outfall), thereby making operations highly water intensive. There is, therefore, there is a strong need and internal motivation to remove Silica from the water that is circulated in the cooling towers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Milestone 1.2.11: H 2 Production from Surrogate Non-Native Corrosion Plumes on Aluminum 6061-T6 Fuel Cladding Surrogates

Thick, localized, “non-native” corrosion plumes have been identified on Advanced Test Reactor fuel elements, raising concern on their impact on the radiolytic formation of molecular hydrogen gas (H 2 ) from aluminum-clad spent nuclear fuel (ASNF) under proposed extended (> 50 years) dry storage conditions. Here, we report our findings on H 2 generation from the gamma irradiation (up to 52 MGy) of surrogate “non-native” corrosion plume coupons: ambient-temperature-corroded (~350 days in water) aluminum alloy 6061 (AA6061) coupons in helium gas environments with ~0% added relative humidity. Additionally, we provide a comparison of proposed ASNF drying techniques— vacuum drying only, vacuum drying + 100 °C for 4 hr, and vacuum drying + 220 °C for 4 hr—on the yield of H 2 from these surrogate systems. The presented data indicates that similar amounts of H 2 (~2 × 10–3 µmol J–1) are formed from gamma irradiated AA6061 coupons corroded under different temperature regimes, i.e., ambient/350 days vs. 90 C/30 days. These findings validate current, complimentary modelling predictions based on high-temperature-corrosion irradiation data only. Further, the application of a heat treatment procedure (100 and 220 °C), in conjunction with vacuum drying, accelerated the rate at which a steady-state H 2 yield was attained, in comparison to vacuum only, due to the removal of H 2 precursors in the form of adsorbed waters. Interestingly, within the confidence limits of our measurements, negligible difference in total H 2 yield was found between the two investigated heat treatment procedures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

EM-Enhanced HyPOR Loop for Fast Fusion Cycles

Vacuum pumps are the heart of a fusion energy facility – fusion power cannot be generated without them. Nevertheless, the vacuum technology needed to operate a viable fuel cycle for a compact fusion power plant does not exist. Commercial vacuum technology offers the best solution to this challenge, but a pump oil recycling and detritiation system is necessary. Conventional oil detritiation processes have only been developed to deal with legacy waste and are too slow and destructive to the oil. Further, post hoc detritiation strategies are intrinsically inefficient. Our approach is to rethink the challenge holistically by designing the pumping fluid and tritium extraction system in an integrated manner to achieve an innovative solution. By selecting an oil for the specific task of pumping tritium and then designing our catalytic system to selectively target the tritium-bearing functional groups, an effective detritiation system (hydrocarbon pump oil recycling, HyPOR, loop) for fusion power plants can be obtained. The project demonstrated a HyPOR loop process that can selectively remove heavier hydrogen isotopes from pump oil, reaching the target of 99.5 % removal, with an uptake of less than 0.01% of tritium throughput, while also purifying the oil of radiation-induced damage. The recycled oil retained its pumping characteristics over 7 recycles and gamma irradiation over 30 MGy. By meeting these targets, the project enable a reduction in pump operational costs from $\$$14.5M/year to $\$$103k/year (>140× reduction), reducing pump electric power consumption from 2.8 MW to 0.25 MW (>10× reduction), and reducing in-process tritium inventory from 2.03 kg to 0.48 kg (>4× reduction).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of HZ-PAN Sorbent Irradiation on Kr Adsorption

Idaho National Laboratory (INL) has developed and studied an engineered form hydrogen mordenite in polyacrylonitrile matrix (HZ-PAN) for krypton (Kr) adsorption. Adsorption studies to date have successfully separated and captured Kr from carrier gas streams, but those studies have used non-radioactive gases for testing. However, if utilized in a used nuclear fuel (UNF) reprocessing facility, this sorbent will be exposed to the potential deleterious effects of radiation. This report explores Kr adsorption behavior on HZ PAN after the sorbent was exposed to gamma radiation. A batch of HZ-PAN was divided into five segments, a control segment that was not exposed to radiation, and the other four segments that were exposed to progressively increased levels of radiation dose, up to 5 MGy. Samples were then analyzed to determine total surface area as well as their capacity to capture Kr. This study reveals HZ PAN retains its initial surface area and Kr-capture capacity after radiation exposure, indicating viability for service in radioactive gases.

42 - ENGINEERING↗

Evaluation of Conservation Voltage Reduction (CVR) on a National Level

Conservation Voltage Reduction (CVR) is a reduction of energy consumption resulting from a reduction of feeder voltage. While there have been numerous CVR systems deployed in North America there has been little substantive analytic analysis of the effect; the majority of the published results are based on empirical field measurements. Since these results are based on empirical measurements it is difficult to extrapolate how this technology will behave on the various types of distribution feeders found throughout the nation. This report has utilized the Taxonomy of Prototypical feeder developed under the Modern Grid Initiative (MGI), now the Modern Grid Strategy (MGS), in order to estimate the benefits of CVR on multiple distribution feeder types. This information will then be used to determine an estimate of the national benefits of a wide scale deployment of CVR.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of Low Gain Avalanche Detector Prototypes’ Response to Gamma Radiation

Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiolytic Gas Production from Aluminum Coupons (Alloy 1100 and 6061) in Helium Environments—Assessing the Extended Storage of Aluminum Clad Spent Nuclear Fuel

Corrosion of aluminium alloy clad nuclear fuel, during reactor operation and under subsequent wet storage conditions, promotes the formation of aluminium hydroxide and oxyhydroxide layers. These hydrated mineral phases and the chemisorbed and physisorbed waters on their surfaces are susceptible to radiation-induced processes that yield molecular hydrogen gas (H 2 ), which has the potential to complicate the long-term storage and disposal of aluminium clad nuclear fuel through flammable and explosive gas mixture formation, alloy embrittlement, and pressurization. Here, we present a systematic study of the radiolytic formation of H 2 from aluminium alloy 1100 (AA1100) and 6061 (AA6061) coupons in “dry” (~0% relative humidity) and “wet” (50% relative humidity) helium environments. Cobalt-60 gamma irradiation of both aluminium alloy types promoted the formation of H 2 , which increased linearly up to ~2 MGy, and afforded G-values of 1.1 ± 0.1 and 2.9 ± 0.1 for “dry” and “wet” AA1100, and 2.7 ± 0.1 and 1.7 ± 0.1 for “dry” and “wet” AA6061. The negative correlation of H 2 production with relative humidity for AA6061 is in stark contrast to AA1100 and is attributed to differences in the extent of corrosion and varying amounts of adsorbed water in the two alloys, as characterized using optical profilometry, scanning electron microscopy, Raman spectroscopy, and X-ray diffraction techniques.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimation of dose delivered to accelerator devices from stripping of 18.5 MeV/n 238 U ions using the FLUKA code

In Korea, a heavy ion accelerator facility (RAON) has been designed for production of rare isotopes. The 90° bending section of this accelerator includes a 1.3-μm-carbon stripper followed by two dipole magnets and other devices. An incident beam is 18.5 MeV/n 238 U 33+,34+ ions passing through the carbon stripper at the beginning of the section. The two dipoles are tuned to transport 238 U ions with specific charge states of 77+, 78+, 79+, 80+ and 81+. Then other ions will be deflected at the bends and cause beam losses. These beam losses are a concern to the devices of transport/beam line. The absorbed dose in devices and prompt dose in the tunnel were calculated using the FLUKA code in order to estimate radiation damage of such devices located at the 90° bending section and for the radiation protection. A novel method to transport multi-charged 238 U ions beam was applied in the FLUKA code by using charge distribution of 238 U ions after the stripper obtained from LISE++ code. The calculated results showed that the absorbed dose in the devices is influenced by the geometrical arrangement. The maximum dose was observed at the coils of first, second, fourth and fifth quadruples placed after first dipole magnet. The integrated doses for 30 years of operation with 9.5 pμA 238 U ions were about 2 MGy for those quadrupoles. In conclusion, the protection of devices particularly, quadruples would be necessary to reduce the damage to devices. Furthermore, results showed that the prompt radiation penetrated within the first 60 - 120 cm of concrete.

43 PARTICLE ACCELERATORS↗

Performance Improvement of LTS Undulators for Synchrotron Light Sources

The joint expertise of ANL and FNAL has led to the production of $\text{Nb}_{3}\text{Sn}$ undulator magnets in operation in the ANL Advanced Photon Source (APS). These magnets showed performance reproducibility close to the short sample limit, and a design field increase of 20% at 820 A. However, the long training did not allow obtaining the expected 50% increase of the on-axis magnetic field with respect to the ∼1 T produced at 450 A current in the ANL NbTi undulator. To address this, 10-pole long undulator prototypes were fabricated, and CTD-101K was replaced as impregnation material with TELENE, an organic olefin-based thermosetting dicyclopentadiene resin produced by RIMTEC Corporation, Japan. Training and magnet retraining after a thermal cycle were nearly eliminated, with only a couple of quenches needed before reaching short sample limit at over 1,100 A. TELENE will enable operation of $\text{Nb}_{3}\text{Sn}$ undulators much closer to their short sample limit, expanding the energy range and brightness intensity of light sources. TELENE is Co-60 gamma radiation resistant up to 7–8 MGy, and therefore already applicable to impregnate planar, helical and universal devices operating in lower radiation environments than high energy colliders.

43 PARTICLE ACCELERATORS↗

Shattered pellet penetration in low and high energy plasmas on DIII-D

Shattered pellet injection (SPI) has been adopted as the baseline disruption mitigation system for ITER, as the radiative payload penetration into DIII-D plasmas from SPI is superior to those using the massive gas injection (MGI) method. Because of the substantial differences in the energy content of ITER plasma and those in present experiments, reliable 3D MHD modeling, benchmarked against present experiments is needed to project to ITER plasmas. In support of these needs, the depth of SPI fragment penetration in DIII-D plasmas was investigated by injecting SPI into two discharges with vastly different energy content and pedestal height. 400 Torr-L pure Ne fragmented pellets at a velocity of about 200 m s−1 were injected into a 0.2 MJ L-mode discharge and a 2 MJ super H-mode discharge. Results show deep penetration of SPI fragments into low-energy plasmas in DIII-D. SPI fragment penetration is reduced as the plasma energy content increases, with some discharges exhibiting penetration that is confined to the outer regions of the plasma. The injected SPI fragments are also spread out over a distance of about 20 cm, which results in some fragments arriving near the end of or after the thermal quench is over.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric results on EURECA

Detector packages were exposed on the European Retrievable Carrier (EURECA) as part of the Biostack experiment inside the Exobiology and Radiation Assembly (ERA) and at several locations around EURECA. The packages consist of different plastic nuclear track detectors, nuclear emulsions and thermoluminescence dosimeters (TLD's). Evaluation of these detectors yields data on absorbed dose and particle and LET spectra. Preliminary results of absorbed dose measurements in the EURECA dosimeter packages are reported and compared to results of the LDEF experiments. The highest dose rate measured on EURECA is 63.3 plus or minus 0.4 mGy d(exp -1) behind a shielding thickness of 0.09 g cm(exp -2) in front of the detector package.

Reitz, G.↗

First Detection of a Foreground Damped Ly-Alpha Absorber Along a GRB Line of Sight?

We present a VLT spectrum of the optical afterglow of GRB 991216, taken 1.5 days after the burst, and HST (Hubble Space Telescope) imaging of the host galaxy, obtained four months later. The spectrum contains three metal absorption-line systems with redshifts z = 1.024, z = 0.803, and z = 0.771, where the highest redshift most likely reflects the distance to the host galaxy. For the z = 1.024 and z = 0.803 systems we tentatively detect MgI which suggests a dense environment at these redshifts. This and the strength of the z = 0.803 Fe lines indicate that this system very likely is a damped Ly-alpha absorber (DLA), which would be the first foreground DLA to be detected along a GRB afterglow sight line. The HST images are consistent with these findings: they show two blobs of light, one underneath the projected OT position, the presumed host galaxy, and the other 0.6" away, which is probably responsible for the absorption lines at z = 0.803. The lowest redshift system can be explained by either one of the two galaxies that are located roughly 2" away from the transient. Including these newly found systems, the total number of DLAS and Lyman limit systems along GRB afterglow sight lines is consistent with the number expected from QSO (quasi-stellar object) absorption line studies. We expect early spectroscopy of GRB afterglows to significantly increase the number of detected foreground absorption systems, and we discuss some advantages over QSO lines of sight.

Vreeswijk, P. M.↗

Effective dose equivalent on the ninth Shuttle--Mir mission (STS-91)

Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).

NASA Center JSC↗

The effects of delta rays on the number of particle-track traversals per cell in laboratory and space exposures

It is a common practice to estimate the number of particle-track traversals per cell or cell nucleus as the product of the ion's linear energy transfer (LET) and cell area. This practice ignores the effects of track width due to the lateral extension of delta rays. We make estimates of the number of particle-track traversals per cell, which includes the effects of delta rays using radial cutoffs in the ionization density about an ion's track of 1 mGy and 1 cGy. Calculations for laboratory and space radiation exposures are discussed, and show that the LET approximation provides a large underestimate of the actual number of particle-track traversals per cell from high-charge and energy (HZE) ions. In light of the current interest in the mechanisms of radiation action, including signal transduction and cytoplasmic damage, these results should be of interest for radiobiology studies with HZE ions.

NASA Discipline Radiation Health↗

The response of thermally and optically stimulated luminescence from Al2O3:C to high-energy heavy charged particles

The thermoluminescence (TL) and optically stimulated luminescence (OSL) response of Al2O3 dosimeters to high-energy heavy charged particles (HCP) has been studied using the heavy ion medical accelerator at Chiba, Japan. The samples were Al2O3 single-crystal chips, of the type usually known as TLD-500, and Luxel(TM) dosimeters (Al2O3:C powder in plastic) from Landauer Inc. The samples were exposed to 4He (150 MeV/u), 12C (400 MeV/u), 28Si (490 MeV/us) and 56Fe (500 MeV/u) ions, with linear energy transfer values covering the range from 2.26 to 189 keV/micrometers in water and doses from 1 to 100 mGy (to water). A 90Sr/90Y beta source, calibrated against a 60Co secondary standard, was used for calibration purposes. For OSL, we used both continuous-wave OSL measurements (CW-OSL, using green light stimulation at 525 nm) and pulsed OSL measurements (POSL, using 532 nm stimulation from a Nd:YAG Q-switched laser). The efficiencies (eta HCP, gamma) of the different HCPs at producing OSL or TL were observed to depend not only upon the linear energy transfer (LET) of the HCP, but also upon the sample type (single crystal chip or Luxel(TM)) and the luminescence method used to define the signal--i.e. TL, CW-OSL initial intensity, CW-OSL total area, or POSL. Observed changes in shape of the decay curve lead to potential methods for extracting LET information of unknown radiation fields. A discussion of the results is given, including the potential use of OSL from Al2O3 in the areas of space radiation dosimetry and radiation oncology. c2004 Elsevier Ltd. All rights reserved.

Heavy Ions↗