Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

The ion mass spectrometer on Giotto

The design of the Giotto ion mass spectrometer (IMS) system, its calibration, and the initial flight performance are discussed. The IMS system consists of two sensors: one optimized for the outer coma, the other for the inner coma, with each sensor obtaining complementary information in the region for which it was not optimized. Both sensors feature mass-imaging characteristics, permitting simultaneous measurements of several ion species by means of multi-detector arrays, with resultant mass per charge resolution of not less than 20. In addition to mass per charge, the energy per charge and the elevation and azimuth of the incident ions were measured during the Giotto flight.

Balsiger, H.↗

Resolving Severe Elemental Isobaric Interferences with a Combined Atomic and Molecular Ionization Source - Orbitrap Mass Spectrometry Approach: The 87Sr and 87Rb Geochronology Pair

Many fields of basic and applied sciences, including geochronology, astronomy, metabolism, nutrition and forensics rely on the ability of mass spectrometry to make isotope ratio measurements with a high degree of certainty. The inability to resolve difficult isobaric interferences still plagues certain measurements of this type. A combined atomic and molecular (CAM) ionization source has been interfaced to a high-field Orbitrap mass spectrometer in an effort to alleviate severe atomic, isobaric interferences. Specifically, this work examines the geochronological-significant 87Sr and 87Rb isotope pair. The mass difference between 87Sr and 87Rb is ~0.3 mDa, requiring a minimum resolving power (R = m/?m) of ~290,000, a value ~30X higher than available with conventional (sector-field) elemental mass spectrometers. Under ultra-high resolution conditions, Sr isotope ratio accuracy and precision were evaluated using NIST Sr SRM 987, yielding precision values of <0.1% relative standard deviation (RSD) for the major isotopes and a calculated LOD of 2 pg mL-1, equivalent to 120 fg Sr for a 60 µL injection. In addition to manipulating the signal transient length, which controls the Orbitrap resolving power, the total number of ions in the electrostatic trap and the relative ion populations (i.e. the 87Sr/87Rb concentration ratio), were found to be influential towards resolving the isobaric species. Ultimately, the 87Sr and 87Rb isotopes were baseline resolved with a calculated mass resolution of >1.7 M. At equal 87Sr and 87Rb intensities, the 87Sr/86Sr was measured as 0.71294 (an error of 0.37%) with a precision of 0.097 %RSD, clearly reflecting the alleviation of the isobaric interference.

Hoegg, Edward D.↗

A Possible Observation of Sigma-nn Continuum Structures and A Bound Sigma-NN State Using the (e, e 'K+) Reaction

The E12-17-003 (e, e'K+) experiment was carried out in the experimental Hall A facility of Jefferson Lab in November 2018. The experiment aimed at providing the experimental data for the unknown Lambda-n interaction by measuring the bound state or the resonance state as indicated by the HypHI experiment. The so obtained Lambda-n interaction was assumed to solve the existing charge symmetry breaking problem in the case of Lambda-N interaction. The experiment used Hall A high resolution spectrometers (both left and right spectrometers) positioned symmetrically at constant angle 13.2 deg. each. A 25 cm long aluminum cylinder filled with H-3 gas was used as a production target. The major calibration data were taken with the H target contained in an identical aluminum cylinder. The electroproduction of Lambda and Sigma^0 via p(e, e'K+)Lambda, Sigma^0 reactions was used to calibrate the absolute energy scale with the known masses of the Lambda and Sigma^0. Then by using the (e, e'K+) Sigma-reaction, two possible Lambda-nn resonance states and one NN bound state were observed. The observed states have the energy resolution about 1.6 MeV (FWHM), however, great r statistics are required to solidly confirm the observed states. The A = 3 and 4 Sigma bound states have been predicted long ago but only the A = 4 Sigma hypernucleus, that is He-4/Sigma, was found in the (K-, pi-) reaction. A careful Monte Carlo study was conducted to study the A (nuclear mass number) dependence on the missing mass resolution by using the identical experimental conditions. The simulated and experimentally obtained Lambda and Sigma^0 channels agreed within 100 keV in sigma, where sigma is the standard deviation. The intrinsic missing mass resolution of A = 3 (3/Lambda-n) resonance was predicted about sigma = 0.67 MeV with a natural width of about 0.6 MeV. However, due to the low statistics the precision does not permit sufficient constrain on the determination of the Lambda-n interaction. The reason of having such low statistics is due to the use of unoptimized Hall A system which was definitely feasible but not ideal for this experiment. In addition, the cross section was found to be much smaller than expected.

Pandey, Bishnu↗

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE↗

An Improved Top-Down Mass Spectrometry Characterization of Chlamydomonas reinhardtii Histones and Their Post-translational Modifications

We present an updated analysis of the linker and core histone proteins and their proteoforms in the green microalga Chlamydomonas reinhardtii by top-down mass spectrometry (TDMS). The combination of high-resolution liquid chromatographic separation, robust fragmentation high, mass spectral resolution, the application of a custom search algorithm, and extensive manual analysis enabled the characterization of 86 proteoforms across all four core histones H2A, H2B, H3 and H4, and the linker histone H1. All canonical H2A paralogs, which vary in their C-termini, were identified, along with an unreported non-canonical variant that had both high levels of acetylation and C-terminal truncations. Similarly, a majority of the canonical H2B paralogs were identified, along with a smaller non-canonical variant, H2B.v, that was highly acetylated. Histone H4 exhibited a novel acetylation profile that differs significantly from that found in other organisms. A majority of H3 was monomethylated at K4, while a small fraction of H3 was trimethylated at K4 and also highly acetylated.

59 BASIC BIOLOGICAL SCIENCES↗

Pyrolysis-high resolution gas chromatography and pyrolysis gas chromatography-mass spectrometry of kerogens and kerogen precursors

A series of kerogens and kerogen precursors isolated from DSDP samples, oil shales and recent algal mats have been examined by Curie point pyrolysis-high resolution gas chromatography and gas chromatography-mass spectrometry. This study has shown that the three main types of kerogens (marine, terrestrial and mixtures of both) can be characterized using these techniques. The marine (algal) kerogens yield principally aliphatic products and the terrestrial kerogens yield more aromatic and phenolic products with some n-alkanes and n-alkenes. The yields of n-alkanes and n-alkenes increase and phenols decrease with increasing geologic age, however, pyrolysis-GC cannot be used to characterize the influence of short term diagenesis on the kerogen structure.

Van De Meent, D.↗

Testing dark matter halo properties using self-similarity

ABSTRACT We use self-similarity in N-body simulations of scale-free models to test for resolution dependence in the mass function and two-point correlation functions of dark matter haloes. We use 10243 particle simulations performed with abacus , and compare results obtained with two halo finders: friends-of-friends (fof ), and rockstar . The fof mass functions show a systematic deviation from self-similarity which is explained by resolution dependence of the fof mass assignment previously reported in the literature. Weak evidence for convergence is observed only starting from haloes of several thousand particles, and mass functions are overestimated by at least as much as $20-25{{\ \rm per\ cent}}$ for haloes of 50 particles. The mass function of the default rockstar halo catalogue (with bound virial spherical overdensity mass), on the other hand, shows good convergence of the order of 50 to 100 particles per halo, with no detectable evidence at the few percent level of any systematic dependence for larger particle number. Tests show that the mass unbinding procedure in rockstar is the key factor in obtaining this much improved resolution. Applying the same analysis to the halo–halo two point correlation function, we find again strong evidence for convergence only for rockstar haloes, at separations sufficiently large so that haloes do not overlap. At these separations, we can exclude dependence on resolution at the $5-10{{\ \rm per\ cent}}$ level once haloes have of the order of 50 to 100 particles. At smaller separations results are not converged even at significantly larger particle number, and bigger simulations would be required to establish the resolution required for convergence.

79 ASTRONOMY AND ASTROPHYSICS↗

Cometary particulate analyzer design definition study

A concept for remotely determining the relative abundance of elements contained in cometary particulates collected by a spacecraft was conducted with very encouraging results. The technique utilizes a short high intensity burst of laser radiation to vaporize and ionize collected particulate material. Ions extracted from this laser-produced plasma are analyzed in a time of flight mass spectrometer to yield an atomic mass spectrum representative of the relative abundance of elements in the particulates. A prototype analyzer system was designed, constructed, and tested. Results show that: (1) energy-time focus performs as predicted in improving resolution; (2) power densities sufficient to produce usable ionization efficiencies can be obtained; (3) complex alloys such as stainless steel can be analyzed; and (4) a tiny, simple and reliable laser used in the demonstration easily meets spacecraft power and mass limitations. A mass resolution of 150 was experimentally demonstrated at mass 108, and an analytical extrapolation predicts a resolution sufficient to separate masses 250 and 251.

Utterback, N. G.↗

FREDA: A Web Application for the Processing, Analysis, and Visualization of Fourier‐Transform Mass Spectrometry Data

The high-resolution measurement capability of Fourier-transform mass spectrometry (FT-MS) has made it a necessity for exploring the molecular composition of complex organic mixtures, like soil, plant, aquatic, and petroleum samples. This demand has driven a need for informatics tools to explore and analyze FT-MS data in a robust and reproducible manner. FREDA is an interactive web application developed to enable spectrometrists to format, process, and explore their FT-MS data without the need for statistical programming expertise. FREDA was built to explore outputs from a molecular identification tool, like CoreMS, and provide a suite of methods to filter data, compute chemical properties of peaks, statistically compare samples and groups of samples, conduct exploratory data analysis, and download the results with a report detailing all steps conducted. To demonstrate the utility of FREDA, an example analysis was conducted using FT-MS data from a soil microbiology study of samples collected in two different soil depths at the Sphagnum bog forest north of Grand Rapids, Minnesota. Differences between the two depths are observed using Kendrick, Gibbs free energy, and van Krevelen plots. G-tests are used to quantify a significant difference between the groups. All analyses and plotting are conducted using only the FREDA application. FREDA is an open-source and readily available web application that allows users to explore and make statistically valid conclusions about their FT-MS data. The application is available online (https://map.emsl.pnnl.gov/app/freda) with a tutorial web series (https://youtu.be/k5HLE2kNSBY?si=yB6sGoyvzxrFf5MP) and freely accessible code on Github (https://github.com/EMSL-Computing/FREDA).

47 OTHER INSTRUMENTATION↗

Separation of isobaric Amino Acids and Small Molecule Metabolites Using Multipass Ion Mobility Analysis

Amino acids along with small molecule metabolites are important biomarkers for the study and detection of diseases that are initially analyzed in untargeted omics fashion. Amino acids and many metabolites are isomeric, and their specific form can have a significant impact on biological function. Chromatographic separation of isomers is challenging, and they cannot be resolved by mass spectrometry alone. Ion mobility is a technique that allows the separation of ions based on their size, shape, and charge. Here we present the results of the separation of isobaric amino acids and small molecule metabolites using a system that allows for multi-pass ion mobility separation which, in turn, enhances the ion mobility resolution of the separation. Amino acid standards and small molecule metabolites commercially available were infused directly into a SELECT SERIES™ Cyclic™ IMS system. Solutions of individual and mixture of the isobaric species were used and the mobility conditions were optimized for multiple passes for each corresponding set of isobaric species. Both ionization polarities and various solvent adducts were tested to provide the best signal intensity and separation. Amino acids such as leucine and isoleucine have previously been separated with ion mobility in a system with lower ion mobility resolution (SYNAPT™ G2 mass spectrometer) rendering about 90% of valley and mobility resolution of around 40 Ω/ΔΩ. With the enhanced ion mobility resolution using the cyclic IMS technique we have obtained almost complete separation of those amino acids rendering a valley of about 10% after 15 passes. For this case, the mobility resolution is around 250 Ω/ΔΩ. Another example is the separation of glucose-6-phosphate from glucose-1-phosphate, and fructose-6phosphate which were separated after 10 passes. For this case, the mobility resolution is around 205 Ω/ΔΩ.

Hernando J Olivos↗

ToF-SIMS spectral data analysis of Paenibacillus sp. 300A biofilms and planktonic cells

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution and high mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Paenibacillus sp. 300A (300A) isolated from the Hanford site in Richland, WA. The strain is known to have metal and sulfur reducing properties and can be used for bioremediation, wastewater treatment, bioengineering and technology development. There is a current need to identify small molecules and fragments produced from bacterial biofilms. Static ToF-SIMS spectra of 300A were obtained using an IONTOF TOF-SIMS V instrument equipped with a 25 keV Bi 3 + metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids and fatty acids to flavonoids, quinolones, and other naturally occurring organic compounds. It is anticipated that the spectral identification of key peaks will assist detection of metabolites, extracellular polymeric substance molecules like polysaccharides, and biologically relevant small molecules using ToF-SIMS in future surface and interface research of bacterial biofilms.

Biofilms↗

Research in particles and fields

The astrophysical aspects of cosmic rays and gamma rays and the radiation and electromagnetic field environment of the Earth and other planets are investigated. These investigations are carried out by means of energetic particle and photon detector systems flown on spacecraft and balloons. Particle astrophysics is directed toward the investigation of galactic, solar, interplanetary, and planetary energetic particles and plasmas. The emphasis is on precision measurements with high resolution in charge, mass, and energy. Gamma ray research is directed toward the investigation of galactic, extragalactic, and solar gamma rays with spectrometers of high angular resolution and moderate energy resolution carried on spacecraft and balloons.

Stone, E. C.↗

Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method’s LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method’s main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of An Improved Miniature Ion Neutral Mass Spectrometer for NASA Applications

The ion optics of NASA's Ion Neutral Mass Spectrometer (INMS) sensor was simulated with three dimensional models of the open source, the quadrupole deflector, the exit lens system and the quadrupole mass analyzer to design more compact models with lower weight. Comparison of calculated transmission with experimental results shows good agreement. Transmission analyses with varying geometrical parameters and voltages throw light on possible ways of reducing the size of the sensor. Trajectories of ions of mass 1-99 amu were simulated to analyze and optimize transmission. Analysis of open source transmission with varying angle of attack shows that the angular acceptance can be considerably increased by programming the voltages on the ion trap/ collimator. Analysis of transmission sensitivity to voltages and misalignments of the quadrupole deflector rods indicate that increased transmission is possible with a geometrically asymmetrical deflector and a deflector can be designed with much lower sensitivities of transmission. Bringing the disks closer together can decrease the size of the quadrupole deflector and also increase transmission. The exit lens system can be redesigned to be smaller by eliminating at least one electrode entirely without loss of transmission. Ceramic materials were investigated to find suitable candidates for use in the construction of lighter weight mass spectrometer. A high-sensitivity, high-resolution portable gas chromatograph mass spectrometer with a mass range of 2-700 amu has been built and will be commercialized in Phase 3.

Swaminathan, Viji K.↗

Redshift evolution of the H2/H i mass ratio in galaxies

ABSTRACT In this paper, we present an attempt to estimate the redshift evolution of the molecular to neutral gas mass ratio within galaxies (at fixed stellar mass). For a sample of five nearby grand design spirals located on the main-sequence (MS) of star-forming galaxies, we exploit maps at 500 pc resolution of stellar mass and star formation rate (M⋆ and SFR). For the same cells, we also have estimates of the neutral (MH i) and molecular ($M_{\rm H_2}$) gas masses. To compute the redshift evolution, we exploit two relations: (i) one between the molecular-to-neutral mass ratio and the total gas mass (Mgas), whose scatter shows a strong dependence with the distance from the spatially resolved MS, and (ii) the one between $\log (M_{\rm {H_2}}/M_{\star })$ and log (MH i/M⋆). For both methods, we and that $M_{\rm H_2}$/MH i within the optical radius slightly decreases with redshift, contrary to common expectations of galaxies becoming progressively more dominated by molecular hydrogen at high redshifts. We discuss possible implications of this trend on our understanding of the internal working of high-redshift galaxies.

Morselli, Laura (ORCID:0000000307532571)↗