Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Quantifying Dynamic Water Storage in Unsaturated Bedrock with Borehole Nuclear Magnetic Resonance

Quantifying the volume of water that is stored in the subsurface is critical to studies of water availability to ecosystems, slope stability, and water-rock interactions. In a variety of settings, water is stored in fractured and weathered bedrock as rock moisture. However, few techniques are available to measure rock moisture in unsaturated rock, making direct estimates of water storage dynamics difficult to obtain. Here, we use borehole nuclear magnetic resonance (NMR) at two sites in seasonally dry California to quantify dynamic rock moisture storage. Additionally, we show strong agreement between NMR estimates of dynamic storage and estimates derived from neutron logging and mass balance techniques. The depths of dynamic storage are up to 9 m and likely reflect the depth extent of root water uptake. To our knowledge, these data are the first to quantify the volume and depths of dynamic water storage in the bedrock vadose zone via NMR.

58 GEOSCIENCES↗

Nuclear magnetic resonance dark-matter searches are sensitive to dark photons and the axion-photon coupling

We demonstrate that nuclear magnetic resonance based searches for dark matter (DM) have intrinsic and powerful sensitivity to dark photons and the axion-photon coupling. The reason is conceptually straightforward. An instrument such as CASPEr-Gradient begins with a large sample of nuclear spins polarized in a background magnetic field. In the presence of axion DM coupled to nucleons, the spin ensemble feels an effective magnetic field 𝐁 ∝ ∇𝑎 that tilts the spins, generating a potentially observable precession. If the magnetic field is real rather than effective, the system responds identically. A real field can be generated by a kinetically mixed dark photon within the shielded region the sample is placed or an axion coupled to photons through its interaction with the background magnetic field. We show that all three signals are detectable and distinguishable. If CASPEr-Gradient were to reach the QCD axion prediction of the axion-nucleon coupling, it would simultaneously be sensitive to kinetic mixings of 𝜀 ≃ 3 × 10 −16 and axion-photon couplings of 𝑔 𝑎⁢𝛾⁢𝛾 ≃ 2 × 10 −16 GeV −1 for 𝑚 ≃ 1 𝜇⁢eV. Our analysis demonstrates that CASPEr-Gradient has the tantalizing possibility of simultaneously measuring two separate couplings of axion dark matter, thereby providing a unique window into the axion’s UV completion.

Beadle, Carl [University of Geneva (Switzerland)] ↗

Quantitative prediction of radio frequency induced local heating derived from measured magnetic field maps in magnetic resonance imaging: A phantom validation at 7 T

Electrical Properties Tomography (EPT) technique utilizes measurable radio frequency (RF) coil induced magnetic fields (B1 fields) in a Magnetic Resonance Imaging (MRI) system to quantitatively reconstruct the local electrical properties (EP) of biological tissues. Information derived from the same data set, e.g., complex numbers of B1 distribution towards electric field calculation, can be used to estimate, on a subject-specific basis, local Specific Absorption Rate (SAR). SAR plays a significant role in RF pulse design for high-field MRI applications, where maximum local tissue heating remains one of the most constraining limits. The purpose of the present work is to investigate the feasibility of such B1-based local SAR estimation, expanding on previously proposed EPT approaches. To this end, B1 calibration was obtained in a gelatin phantom at 7 T with a multi-channel transmit coil, under a particular multi-channel B1-shim setting (B1-shim I). Using this unique set of B1 calibration, local SAR distribution was subsequently predicted for B1-shim I, as well as for another B1-shim setting (B1-shim II), considering a specific set of parameter for a heating MRI protocol consisting of RF pulses plaid at 1% duty cycle. Local SAR results, which could not be directly measured with MRI, were subsequently converted into temperature change which in turn were validated against temperature changes measured by MRI Thermometry based on the proton chemical shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solid-State Nuclear Magnetic Resonance as a Tool to Probe the Impact of Mechanical Preprocessing on the Structure and Arrangement of Plant Cell Wall Polymers

Efficient separation of the plant cell wall polymers during lignocellulose processing has been historically challenging due to insolubility of the polymers and their propensity for recalcitrant reassembly. Methods, such as “lignin first” extraction techniques, have advanced efficient biomass use, but the molecular mechanisms for recalcitrance remain enigmatic. Here, we discuss how solid-state Nuclear Magnetic Resonance (NMR) approaches report on the 3D organization of cellulose, xylan, and lignin in the plant cell wall. Recent results illustrate that the organization of these polymers varies across biomass sources and sample preparation methods, with even minimal physical processing causing significant effects. These structural differences contribute to variable extraction efficiencies for bioproducts after downstream processing. We propose that solid-state NMR methods can be applied to follow biomass processing, providing an understanding of the polymer rearrangements that can lead to poor yields for the desired bioproducts. The utility of the technique is illustrated for mechanical processing using lab-scale vibratory ball milling of Sorghum bicolor .

59 BASIC BIOLOGICAL SCIENCES↗

Microscopic subsurface characterization of layered magnetic materials using magnetic resonance force microscopy

This project resulted in the following accomplishments: 1) The invention of scanned probe ferromagnetic resonance microscopy. Upon implementation and refinement this approach was used to measure static and dynamic magnetic resonance properties of ferromagnets with an unprecedented combination of spectral and spatial resolution. 2) Demonstration and study of spin pumping in a pristine ferromagnet across a boundary defined entirely by a magnetic field gradient, and so free of materials discontinuities. 3) First demonstrated highly efficient dynamic spin injection from Y 3 Fe 5 O 12 (YIG) into NiO, an antiferromagnetic (AF) insulator and robust spin propagation in AF NiO over distances up to 100-nm thickness; both spin injection and spin transport are mediated by the AF spin correlations. 4) Demonstration of exceptionally high efficiency conversion of spin current to charge current achieved in spin pumping from the dynamic magnetization of a ferromagnetic insulator into a variety of adjacent metal films. 5) Seminal study of the nature of spin-orbit coupling in d-electron metals that revealed the dominant sensitivity of the d-orbital moment to the d-electron count and revealing the important roles of both d-electron configuration and atomic number in the physics of the spin Hall effect. 6) Demonstration of observation of FMR by means of optically-detected NV diamond relaxometry that provided a highly sensitive, spatially resolved FMR detection method and revealed spin pumping across 100-nm length scales by means of dipolar coupling. 7) Using magnetic field localization, developed for FMR imaging, demonstrated a novel approach to discretizing spin wave modes to improve the characteristics of auto-oscillators driven by pure spin currents produced by the spin Hall effect. 8) We demonstrated large spin pumping signals from propagating high wavevector spinwaves in thin film YIG find that the spin pumping efficiency was insensitive to wavevector thus emphasizing the promise of thin YIG films for spinwave-based spintronics by allowing for predictable down-scaling of device dimensions and enabling a broad range of operational frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Porous silicon nanoparticles as biocompatible contrast agents for magnetic resonance imaging

We propose porous silicon nanoparticles (PSi NPs) with natural oxide coating as biocompatible and bioresorbable contrast agents for magnetic resonant imaging (MRI). A strong shortening of the transversal proton relaxation time (T{sub 2}) was observed for aqueous suspensions of PSi NPs, whereas the longitudinal relaxation time (T{sub 1}) changed moderately. The longitudinal and transversal relaxivities are estimated to be 0.03 and 0.4 l/(g·s), respectively, which are promising for biomedical studies. The proton relaxation is suggested to undergo via the magnetic dipole-dipole interaction with Si dangling bonds on surfaces of PSi NPs. MRI experiments with phantoms have revealed the remarkable contrasting properties of PSi NPs for medical diagnostics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging and Spectroscopy to Assess Leg Muscle Macrostructure and Microstructure in Healthy Older Women: A Feasibility Assessment

Advanced magnetic resonance (MR) scanning techniques, such as diffusion tensor imaging (DTI) and proton MR spectroscopy ({sup 1}H-MRS) permit microstructural evaluation of water diffusivity and intramyocellular lipid content, respectively. We aimed to determine the feasibility of performing advanced MR scanning (proton density [PD] weighted imaging, DTI, and {sup 1}H-MRS) to evaluate properties of leg muscles in older women with respect to: (1) participant recruitment using three community-based strategies; (2) participant tolerance to the MRI scan acquisition protocol; and (3) scan acquisition and analyses protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of resonant magnetic perturbations on nonlinearly driven modes in drift-wave turbulence

In this work, we study the effects of resonant magnetic perturbations (RMPs) on turbulence, flows, and confinement in the framework of resistive drift wave turbulence. We extend the Hasegawa-Wakatani model to include RMP fields. The effect of the RMPs is to induce a linear coupling between the zonal electric field and the zonal density gradient, which drives the system to a state of electron radial force balance for large ({delta}B{sub r}/B{sub 0}). Both the vorticity flux (Reynolds stress) and particle flux are modulated. We derive an extended predator prey model which couples zonal potential and density dynamics to the evolution of turbulence intensity. This model has both turbulence drive and RMP amplitude as control parameters and predicts a novel type of transport bifurcation in the presence of RMPs. We find states that are similar to the ZF-dominated state of the standard predator-prey model, but for which the power threshold is now a function of the RMP strength. For small RMP amplitude, the energy of zonal flows decreases and the turbulence energy increases with ({delta}B{sub r}/B{sub 0}), corresponding to a damping of zonal flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of resonant magnetic perturbations on zonal flows and microturbulence

Results from a joint experimental and computational effort studying the effect of resonant magnetic perturbations (RMPs) on microturbulence levels and their connection to zonal flows in the DIII-D tokamak L-mode are presented. Beam emission spectroscopy measurements show a direct increase in density fluctuations at microturbulent scales with increasing RMP amplitude, suggesting that magnetic activity introduced by the RMP affects the regulation of microturbulence on DIII-D. This is analogous to how MHD-scale magnetic fluctuations arising from tearing modes have been observed in simulations to increase microturbulence levels in the reversed-field pinch (RFP). In the RFP, this is attributed to magnetic fluctuations eroding turbulence-limiting zonal flows; this work examines if a similar mechanism is present for DIII-D microturbulence. Gyrokinetic simulations find that the application of an RMP corresponds directly to a decrease in zonal flow levels, producing a similar increase of turbulent fluctuation levels over a range of RMP amplitudes as observed in the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigations of plasma response associated with resonant magnetic perturbation fields using perturbation method in KSTAR H-mode plasmas

Abstract The plasma response associated with the resonant magnetic perturbation (RMP) field was investigated using the small edge perturbations induced by a modulated supersonic molecular beam injection (SMBI) in KSTAR. The modulated SMBI provides a time-varying perturbation of the plasma density source in the region just inside the last closed flux surface and a modulated flow damping rate. Radial propagation of the toroidal rotation perturbation induced by SMBI from the q = 3 surface to the q = 2 surface was observed. Theoretical analysis using the general perturbed equilibrium code of the RMP intensity profiles of the RMP field is consistent with the phase profile of the toroidal rotation perturbation.

Physics↗

SU-E-J-157: Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation

Purpose: To develop an imaging technique that enables us to acquire T2- weighted 4D Magnetic Resonance Imaging (4DMRI) with sufficient spatial coverage, temporal resolution and spatial resolution for clinical evaluation. Methods: T2-weighed 4DMRI images were acquired from a healthy volunteer using a respiratory amplitude triggered T2-weighted Turbo Spin Echo sequence. 10 respiratory states were used to equally sample the respiratory range based on amplitude (0%, 20%i, 40%i, 60%i, 80%i, 100%, 80%e, 60%e, 40%e and 20%e). To avoid frequent scanning halts, a methodology was devised that split 10 respiratory states into two packages in an interleaved manner and packages were acquired separately. Sixty 3mm sagittal slices at 1.5mm in-plane spatial resolution were acquired to offer good spatial coverage and reasonable spatial resolution. The in-plane field of view was 375mm × 260mm with nominal scan time of 3 minutes 42 seconds. Acquired 2D images at the same respiratory state were combined to form the 3D image set corresponding to that respiratory state and reconstructed in the coronal view to evaluate whether all slices were at the same respiratory state. 3D image sets of 10 respiratory states represented a complete 4D MRI image set. Results: T2-weighted 4DMRI image were acquired in 10 minutes which was within clinical acceptable range. Qualitatively, the acquired MRI images had good image quality for delineation purposes. There were no abrupt position changes in reconstructed coronal images which confirmed that all sagittal slices were in the same respiratory state. Conclusion: We demonstrated it was feasible to acquire T2-weighted 4DMRI image set within a practical amount of time (10 minutes) that had good temporal resolution (10 respiratory states), spatial resolution (1.5mm × 1.5mm × 3.0mm) and spatial coverage (60 slices) for future clinical evaluation.

60 APPLIED LIFE SCIENCES↗

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effect of aspect ratio on plasma response to resonant magnetic perturbations in tokamak devices

A systematic numerical study is carried out, computing and comparing the plasma response to the resonant magnetic perturbation (RMP) field, applied for controlling edge localized modes (ELMs), in a series of tokamak plasmas with varying aspect ratio and utilizing the MARS-F code. The aspect ratio is scanned either by varying the plasma major radius at a fixed minor radius or by varying the latter while fixing the former. Both approaches yield similar results when compared in terms of quantities with proper normalizations. In general, a non-monotonic dependence of the resonant response field (normalized by the vacuum counterpart) near the plasma edge is found with varying aspect ratio, indicating that a given ELM control coil current configuration strongly favors plasmas with a certain aspect ratio. This optimal aspect ratio, on the other hand, depends on the toroidal as well as poloidal (i.e., coil phasing) spectra of the applied RMP field. The equilibrium (edge) safety factor, the plasma shape, and the plasma toroidal flow are all fixed to ensure that the effects identified here are predominantly due to the plasma aspect ratio.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Revealing Molecular Mechanisms in Hierarchical Nanoporous Carbon via Nuclear Magnetic Resonance

Hierarchical nanoporous carbons (HNC) have been proven to be an effective adsorbent for the adsorption of volatile organic compounds (VOCs) and CO 2 . However, questions remain regarding the hierarchical structure regulation, the adsorption mechanisms of adsorbate uptake, and interactions within the HNC. Here, we synthesize HNC from wood, using a microwave-induced heating method incorporating K 2 CO 3 activation. Our HNC exhibit Murray's law multiscale structures, prompting a molecular-scale study of adsorbate adsorption via nuclear magnetic resonance (NMR). NMR chemical shifts are consistent with ring-current effects from the adsorbent. Our NMR technique provides a convenient way to quantitate adsorption of adsorbate in HNC. VOC vapor adsorption results show NMR chemical-shift changes with time, suggesting initial adsorption into mesopores, followed by diffusion into micropores. Schroeder's paradox is demonstrated by differences in observed shifts for adsorbed liquid vis-à-vis vapor phase in these HNC. These HNC show high CO 2 adsorption capacity, portending applications to carbon capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Readout of Oriented Triplet Excitons in Linear Acenes via Room-Temperature Electrically Detected Magnetic Resonance

In this study, optically generated molecular spin centers offer an attractive platform for room-temperature spintronic and quantum applications. The linear acene family of molecules are especially good candidates due to their efficient generation of highly polarized triplet excitons via singlet fission. However, the direct detection and manipulation of these spin centers in thin films via the electrical means desirable for ultimate microelectronic devices has proven challenging. In particular, highly oriented triplet features have previously been detected in crystalline anthracene but longer acenes reveal only doublet features in Electrically-Detected Magnetic Resonance (EDMR). In this work we present EDMR spectra of highly oriented triplet excitons in pentacene for the first time, using a host-guest style device made of tetracene and pentacene. The guest acts as an energetic trap site, permitting the isolation and detection of molecular triplets at room temperature. Modeling of these results shows that the observed resonance features correspond to triplet sublevel transitions on isolated pentacene guest molecules. Rotation of the applied field confirms the tendency of the linear acenes to self-orient with the longest molecular axis perpendicular to the device substrate. Lastly, we find the disappearance of resonant triplet features in the neat acenes is not primarily due to the effects of exciton delocalization, but a broader mechanism of spin relaxation primarily influenced by exciton diffusivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring the internal swelling in cementitious mortars with single-sided 1H nuclear magnetic resonance

Moisture transport into concrete and mortar surfaces strongly influences the durability of structures. Transport processes are foremost controlled by the material's porosity. Cementitious materials, such as concrete and mortars, exhibit distinct changes in pore structure while drying and subsequent rewetting due to the internal shrinkage and swelling of the layered calcium-silicate hydrates. Mortars with different w/c-ratios and binders were dried and rewetted and the subsequent time dependent changes in water filled pore structure were monitored with single-sided {sup 1}H nuclear magnetic resonance. This technique combines a localized depiction of all pore water with a good time resolution. The NMR signal is split into the four pore species C-S-H interlayer water, gel pore water, interhydrate water, and capillary water by multi-exponential analysis. Two consecutive running processes in the swelling of cementitious mortars were identified and discussed based on recent models of the cement microstructure as well as its implications on the sorptivity.

36 MATERIALS SCIENCE↗