Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC MIRROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Magnetic pulsations from 0.1 to 4.0 Hz and associated plasma properties in the earth's subsolar magnetosheath and plasma depletion layer

AMPTE CCE magnetic field data acquired during periods of magnetospheric compressions when the spacecraft sampled the magnetosheath are analyzed on the basis of a dynamic spectral analysis covering frequencies 0.1 to 4.0 Hz. Ion and electron data are used to identify regions, to monitor the upstream shock geometry, and to evaluate moments of the proton distribution. Fourteen encounters representing 46 hr of observations are analyzed. A compilation of the temporal sequence of spectral structures shows that electromagnetic ion cyclotron (EMIC) waves occur next to the magnetopause, while mirror waves occur outside the region of EMIC waves. It is concluded that there is a close relationship between EMIC waves in the sheath and the plasma depletion layer. For quasi-parallel upstream conditions, the magnetic field power spectra often exhibit no band limited structures but only broadband noise.

Anderson, B. J.↗

Wave-particle interactions for relativistic electrons in a recirculation acceleration model

Evidence is presented for the presence of a multistep process, leading to relativistic electron populations, in the magnetospheres of earth and Jupiter. After an initial injection of a spectrally soft electron component in the outer magnetosphere, inward radial diffusion acts to accelerate the electrons perpendicular to the local magnetic field; strong wave-particle interactions deep in the magnetosphere is of primary significance in the pitch-angle scattering of electrons, thereby lowering their mirror points. An additional model element of critical significance, again involving wave-particle interactions, is energy-preserving outward transport near the mirror points where the field strength is large and trans-L distances are small.

Baker, D. N.↗

Polarimetry of the HI Lyman-alpha for coronal magnetic field diagnostics

We discuss and analyze the possible sources of observational and instrumental uncertainty that can be encountered in measuring magnetic fields of the solar corona through polarimetric observations of the Hanle effect of the coronal Ly-alpha line. The Hanle effect is the modification of the linear polarization of a resonantly scattered line, due to the presence of a magnetic field. Simulated observations are used to examine how polarimetric measurements of this effect are affected by the line-of-sight integration, the electron collisions, and the Ly-alpha geocorona. We plan to implement the coronal magnetic field diagnostics via the Ly-alpha Hanle effect using an all-reflecting Ly-alpha coronagraph/polarimeter (Ly-alphaCoPo) which employs reflecting multilayer mirrors, polarizers, and filters. We discuss here the requirements for such an instrument, and analyze the sources of instrumental uncertainty for polarimetric observations of the coronal Ly-alpha Hanle effect. We conclude that the anticipated polarization signal from the corona and the expected performance of the Ly-alphaCoPo instrument are such that the Ly-alpha Hanle effect method for coronal field diagnostics is feasible.

Fineschi, Silvano↗

Optical Characteristics of the Marshall Space Flight Center Solar Ultraviolet Magnetograph

This paper will describe the scientific objectives of the Marshall Space Flight Center (MSFC) Solar Ultraviolet Magnetograph Investigation (SUMI) and the optical components that have been developed to meet those objectives. In order to test the scientific feasibility of measuring magnetic fields in the UV, a sounding rocket payload is being developed. This paper will discuss: (1) the scientific measurements that will be made by the SUMI sounding rocket program, (2) how the optics have been optimized for simultaneous measurements of two magnetic lines CIV (1550 Angstroms) and MgII (2800 Angstroms), and (3) the optical, reflectance, transmission and polarization measurements that have been made on the SUMI telescope mirror and polarimeter.

West, E. A.↗

The Marshall Space Flight Center Solar Utraviolet Magnetograph

This paper will describe the objectives of the Marshall Space Flight Center (MSFC) Solar Ultraviolet Magnetograph Investigation (SUMI) and the optical components that have been developed to meet those objectives. In order to test the scientific feasibility of measuring magnetic fields in the W, a sounding rocket payload is being developed. This paper will discuss: (1) the scientific measurements that will be made by the SUMI sounding rocket program, (2) how the optics have been optimized for simultaneous measurements of two magnetic lines CIV (1550 Angstroms) and MgII (2800 Angstroms), and (3) the optical, reflectance, transmission and polarization measurements that have been made on the SUMI telescope mirrors and polarimeter.

West, E. A.↗

Nighttime ionization by energetic particles at Wallops Island in the altitude region 120 to 200 km

Five Nike Apache rockets, each including an energetic particle spectrometer and an electron density-electron temperature experiment, have been launched from Wallops Island (L = 2.6) near midnight under varying geomagnetic conditions. On the most recent of these (5 January 1978) an additional spectrometer with a broom magnet, and a 391.4 nm photometer were flown. The data from this flight indicate that the energetic particle flux consists predominantly of protons, neutral hydrogen and possibly other energetic nuclei. The energy spectrum becomes much softer and the flux more intense with increasing Kp for 10-100 keV. The pitch angle distribution at 180 km is asymmetrical with a peak at 90 deg indicating that the majority of particles are near their mirroring altitude. Ionization rates are calculated based on the measured energy spectrum and mirror height distribution. The resulting ionization rate profile is found to be nearly constant with altitude in the region 120 to 200 km. The measured energetic particle flux and calculated ionization rate from the five flights are found to vary with magnetic activity (based on the Kp and Dst indexes) in the same way as the independently derived ionization rates deduced from the electron density profile.

Voss, H. D.↗

Observation of a linked-loop quantum state in a topological magnet

Quantum phases can be classified by topological invariants, which take on discrete values capturing global information about the quantum state. Over the past decades, these invariants have come to play a central role in describing matter, providing the foundation for understanding superfluids, magnets, the quantum Hall effect, topological insulators, Weyl semimetals and other phenomena. Here we report an unusual linking-number (knot theory) invariant associated with loops of electronic band crossings in a mirror-symmetric ferromagnet. Using state-of-the-art spectroscopic methods, we directly observe three intertwined degeneracy loops in the material's three-torus, T 3 , bulk Brillouin zone. We find that each loop links each other loop twice. Through systematic spectroscopic investigation of this linked-loop quantum state, we explicitly draw its link diagram and conclude, in analogy with knot theory, that it exhibits the linking number (2, 2, 2), providing a direct determination of the invariant structure from the experimental data. Here we further predict and observe, on the surface of our samples, Seifert boundary states protected by the bulk linked loops, suggestive of a remarkable Seifert bulk-boundary correspondence. Our observation of a quantum loop link motivates the application of knot theory to the exploration of magnetic and superconducting quantum matter.

36 MATERIALS SCIENCE↗

Measuring Segmented Primary Mirror WFE in the Presence of Vibration and Thermal Drift on the Light-Weighted JWST

The light-weighted design of the Optical Telescope Element (OTE) of the James Webb Telescope (JWST) leads to additional sensitivity to vibration from the ground - an important consideration to the measurement uncertainty of the wavefront error (WFE) in the primary mirror. Furthermore, segmentation of the primary mirror leads to rigid-body movements of segment areas in the WFE. The ground vibrations are minimized with modifications to the test facility, and by the architecture of the equipment supporting the load. Additional special test equipment (including strategically placed isolators, tunable mass dampers, and cryogenic magnetic dampers) mitigates the vibration and the response sensitivity before reaching the telescope. A multi-wavelength interferometer is designed and operated to accommodate the predicted residual vibration. Thermal drift also adds to the measurement variation. Test results of test equipment components, measurement theory, and finite element analysis combine to predict the test uncertainty in the future measurement of the primary mirror. The vibration input to the finite element model comes from accelerometer measurements of the facility with the environmental control pumps operating. One of the isolators have been built and tested to validate the dynamic performance. A preliminary model of the load support equipment and the OTE with the Integrated Science Instrument Module (ISIM) is complete. The performance of the add-on dampers have been established in previous applications. And operation of the multi-wavelength interferometer was demonstrated on a scaled hardware version of the JWST in an environment with vibration and thermal drift.

Whitman, Tony L.↗

Observations of plasma depletion in the magnetosheath at the dayside magnetopause

In a set of 17 low- to mid-latitude crossings of the dayside and near-dayside magnetopause, Imp 6 plasma measurements show 11 cases of decreases in magnetosheath density just outside the boundary which are consistent with plasma depletion owing to magnetic flux tube compression as the field becomes draped against the magnetopause. Pressure anisotropies in the sense pressure perpendicular to the field direction greater than pressure parallel to it are a predicted result of the plasma depletion and field compression, and such anisotropies are observed. Application of the mirror instability criterion, which predicts growth of slow mode magnetoacoustic waves for values of the ratio between the cited pressures greater than a critical value, suggests that dayside magnetosheath plasma is usually unstable. One of the seventeen cases shows long-period waveforms in the 100-s density data that are 180 deg out of phase with simultaneous waveforms in the magnetic field strength. These data are interpreted as the signature of slow mode magnetoacoustic waves.

Crooker, N. U.↗

Electron density profile and associated fluctuation measurements using a microwave reflectometry diagnostic on Helically Symmetric eXperiment (HSX)

Abstract A dual-band frequency-modulated reflectometry is employed on the Helically Symmetric eXperiment (HSX) stellarator. This system equips a fast PIN switch to alternate the frequency source between two voltage-controlled oscillators, providing an operational frequency range from 14.5 GHz to 25.5 GHz. A monostatic antenna geometry and an ellipsoidal mirror are implemented in the vessel of HSX, where the polarization of the transmitted microwave can be switched between O- and X-mode to accommodate the magnetic field and plasma density. Although the original system was designed for density fluctuation measurement, significant efforts have been undertaken to improve the system performance and to realize the density profile inversion. Recent improvements of the system reported here include calibration of the dispersion in the transmission line, optimization of the waveform, and implementation of the Choi-Williams time–frequency distribution for spectral analysis. In this paper, we present the optimization of the reflectometry system along with first experimental measurements of the density profile and observations of fluctuations during gas puffing experiments.

Han, X. (ORCID:0000000184986433)↗

Defect-engineered room-temperature ferromagnetism in quasi-two-dimensional nitrided CoTa 2 O 6

Thermal ammonolysis of quasi-two-dimensional (quasi-2D) CoTa 2 O 6 yields the O 2– /N 3– and anionic vacancy-ordered Co 2+ $Ta^{5+}_{2}$O 6–x N 2x/3 $\square$ x/3 (x $\leqslant$ 0.15), which exhibits a transition from antiferromagnetism to defect-engineered above-room-temperature ferromagnetism. First-principles calculations reveal that the origin of ferromagnetism is a particular CoO 5 N configuration with N located at Wyckoff position 8j, which breaks mirror symmetry about the ab plane. A pressure-induced electronic phase transition is also predicted at ~24.5 GPa, accompanied by insulator-to-metal transition and magnetic moment vanishing.

36 MATERIALS SCIENCE↗

Twinac: A Universal Framework for Virtual Accelerator Controls

We propose a universal framework for a system of virtual accelerator controls (Twinac), a standard toolkit for research institutions to design, maintain, and use a real-time, end-to-end "digital twin" of their particle accelerator facility. This virtual counterpart will mirror any physical accelerator to provide (1) predictive maintenance; (2) surveillance of hidden environmental factors, such as seasonal temperature variations, which could impact performance of power supplies, magnets, and other instruments; and (3) a capability to model novel ways to operate the accelerator without risking equipment damage. Twinac is envisioned as accelerator facility agnostic, allowing institutions to share and reuse myriad simulation approaches (analytics-based, A.I.-driven, or combinations of the like) across facilities. The Twinac system lays the groundwork for a collaborative network of institutions to maintain and update this shared virtual accelerator technology.

Miceli, Tia M. [Fermilab] (ORCID:0000000265577789)↗

Kitt Peak 60-cm vacuum telescope

A major new solar-research telescope conceived and built during a time of budget restraint is described. The observation of magnetic and velocity (circulation) field structure on a synoptic basis and with diffraction-limited resolution is the aim. New optical features include the use of oversize mirrors and windows to avoid thermal edge effects and the placement of the coelostat feed outside the vacuum, mainly for economy. The site selected has prevailing winds that clear thermals from these mirrors. Test data in the form of the system MTF and optical transmission, together with examples of full disk magnetograms and photoheliograms, show present performance capability. Measured MTF indicates a response of 0.2 at 1 sec of arc (whereas diffraction-limited response would be about 0.8). System transmission, including the accompanying spectrograph, is only 2-3% (wavelength 0.44-1.1 microns). Thus, both the optical quality and efficiency are subject to improvement.

Livingston, W. C.↗

Magnetotail instability

The stability of the geomagnetic tail is investigated on the basis of three dimensional resistive magnetohydrodynamic simulations, using different dynamic constraints and different initial equilibria. Different forms of the energy equation for isotropic pressure are found to have no significant effect on the dynamic growth of a resistive tearing instability, which is responsible for near Earth reconnection, plasmoid formation and ejection, and the generation of fast plasma flows. The constraints of a modified double adiabatic approach, however, can quench the tearing instability through the development of large, mirror type, anisotropies in the boundary regions of the plasma sheet, unless isotropization occurs on fast, nearly Alfvenic, time scales. The presence of a net cross tail magnetic field component B(sub yN) can reduce the growth of the instability without complete stabilization. An increase of B(sub z) from midnight toward the tail flanks, however, by more than a factor of about 3, apparently completely stabilizes the tearing mode. Stabilization and destabilization thus may depend on properties and constraints (and their release) in regions other than the neutral sheet where reconnection is initiated.

Birn, Joachim↗

Optical Characteristics of the Marshall Space Flight Center Solar Ultraviolet Magnetograph

This paper will describe the scientific objectives of the MSFC SUMI project and the optical components that have been developed to meet those objectives. In order to test the scientific feasibility of measuring magnetic fields in the UV, a sounding rocket payload is being developed, This paper will describe the optical measurements that have been made on the SUMI telescope mirrors and polarization optics.

West, Edward↗

Cryogenic Scan Mechanism for Fourier Transform Spectrometer

A compact and lightweight mechanism has been developed to accurately move a Fourier transform spectrometer (FTS) scan mirror (a cube corner) in a near-linear fashion with near constant speed at cryogenic temperatures. This innovation includes a slide mechanism to restrict motion to one dimension, an actuator to drive the motion, and a linear velocity transducer (LVT) to measure the speed. The cube corner mirror is double-passed in one arm of the FTS; double-passing is required to compensate for optical beam shear resulting from tilting of the moving cube corner. The slide, actuator, and LVT are off-the-shelf components that are capable of cryogenic vacuum operation. The actuator drives the slide for the required travel of 2.5 cm. The LVT measures translation speed. A proportional feedback loop compares the LVT voltage with the set voltage (speed) to derive an error signal to drive the actuator and achieve near constant speed. When the end of the scan is reached, a personal computer reverses the set voltage. The actuator and LVT have no moving parts in contact, and have magnetic properties consistent with cryogenic operation. The unlubricated slide restricts motion to linear travel, using crossed roller bearings consistent with 100-million- stroke operation. The mechanism tilts several arc seconds during transport of the FTS mirror, which would compromise optical fringe efficiency when using a flat mirror. Consequently, a cube corner mirror is used, which converts a tilt into a shear. The sheared beam strikes (at normal incidence) a flat mirror at the end of the FTS arm with the moving mechanism, thereby returning upon itself and compensating for the shear

Brasunas, John C.↗

VERDI: VERsatile DIffractometer with wide-angle polarization analysis for magnetic structure studies in powders and single crystals

The VERsatile DIffractometer will set a new standard for a world-class magnetic diffractometer with versatility for both powder and single crystal samples and capability for wide-angle polarization analysis. The instrument will utilize a large single-frame bandwidth and will offer high-resolution at low momentum transfers and excellent signal-to-noise ratio. A horizontal elliptical mirror concept with interchangeable guide pieces will provide high flexibility in beam divergence to allow for a high-resolution powder mode, a high-intensity single crystal mode, and a polarized beam option. A major science focus will be quantum materials that exhibit emergent properties arising from collective effects in condensed matter. The unique use of polarized neutrons to isolate the magnetic signature will provide optimal experimental input to state-of-the-art modeling approaches to access detailed insight into local magnetic ordering.

36 MATERIALS SCIENCE↗

Montel mirror based collimating analyzer system for high-pressure resonant inelastic X-ray scattering experiments

Resonant inelastic X-ray scattering (RIXS) is increasingly playing a significant role in studying highly correlated systems, especially since it was proven capable of measuring low-energy magnetic excitations. However, despite high expectations for experimental evidence of novel magnetic phases at high pressure, unequivocal low-energy spectral signatures remain obscured by extrinsic scattering from material surrounding the sample in a diamond anvil cell (DAC): pressure media, Be gasket and the diamond anvils themselves. A scattered X-ray collimation based medium-energy resolution (~100 meV) analyzer system for a RIXS spectrometer at the Ir L 3 -absorption edge has been designed and built to remediate these difficulties. Due to the confocal nature of the analyzer system, the majority of extrinsic scattering is rejected, yielding a clean low-energy excitation spectrum of an iridate Sr 2 IrO 4 sample in a DAC cell. Finally, the energy resolution of different configurations of the collimating and analyzing optics are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗