Seal testing of large diameter rocket motors

This investigative program examines leakage testing of elastomeric O-ring seals for a solid rocket casing and provides direction towards an improved nondestructive postassembly test. It also details test equipment for the Space Shuttle systems solid rocket boosters (SRB). The results are useful to designers of hardware for pressure containment vessels which use O-ring seals. Using several subscale seal and groove configuration test fixtures equipped with either two or three O-ring seals in series, seal integrity is investigated with both a pressure decay and flowmeter methods. Both types of test equipment adequately detect the practical range of expected seal leak rates of 1 to 0.0001 sccs. The flowmeter leak test equipment appears to reduce testing time substantially. Limited seal leakage testing is performed on full-sized rocket motor segment seals, a pre-Challenger short stack, providing comparison of bore seals to test specimen bore and face seals. The conclusions are that seal reliability, verified via a performance pressure test, can be affected by temperature, quantity of grease, test pressure, and seal pressure load direction. Potential seal failure scenarios including contamination, seal damage, and sealing surface damage are discussed. Recommendations are made for an improved test procedure.

Moore, N. B.↗

Effect of PdO on TiO(sub2) Loading on Chemochromic Detection of Hydrogen

Safety is always a concern in all applications that utilize hydrogen (H(sub2)) in one form or the other. Hydrogen leaks are invisible and odorless. In addition, blending odorants or additives into hydrogen in a manner similar to natural gas is generally undesirable for certain applications including proton exchange membrane fuel cells. To facilitate detection of the location of hydrogen leaks, a special chemochromic H(sub2) sensing material that employs titania (Ti0(sub2)) supported palladium oxide (PdO) pigments encapsulated within a special silicone matrix has been developed at the Florida Solar Energy Center (FSEC). Several batches of PdO H(sub2) sensing pigments were synthesized using various Ti0(sub2) supports and their hydrogen detection activity determined. TEM and Particle size distribution analysis showed that smaller particles with hemispherical crystalline structure produced faster coloration kinetics when exposed to H(sub2) gas. However, uniformly distributed PdO particles on the Ti0(sub2) surface displayed greater color contrast, quantified by delta epsilon measurements. XRD analysis indicated that the crystalline phase of Ti0(sub2) had no effect on the chemochromic performance of the pigments in laboratory environment.

Mohajeri, Nahid↗

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION↗

Thermal-leak analyzer for vacuum-jacketed lines

Technique involves coating suspected area with water-soluble black paint that gives even, infrared emission. Painted area is warmed with heat gun; an infrared scanner is used to detect cooled spot on jacket exterior. Introduction of atmospheric pressure into jacket intensifies leak jet and improves test sensitivity.

Heisman, R. M.↗

Surface Wave Based Non-conductor-contact Reflectometry Method for Insulation and Jacket Damage Detection in Multi-Conductor Cables

This paper presents a non-conductor-contact surface wave reflectometry technique to locate insulation and jacket damage on multi-conductor cables at a distant location from the sensor. Simulation studies were conducted using Ansys high frequency structure simulator (HFSS). A GHz range surface wave launcher was employed such that maximum surface wave energies were confined in the insulation layer while minimizing attenuation. The wave launcher can potentially be mounted on the outer surface of live cables or cable conduits and requires no physical connection to the conductors. Multiple simulations involving a 4 GHz wave launcher and a three-conductor cable with an 8 mm outer diameter were carried out demonstrating the efficacy of the proposed method. Water leak and different types of insulation/jacket damage were simulated and detected.

reflectometry, multi-conductor cable, frequency do↗

A Quadrupole Ion Trap Mass Spectrometer for Quantitative Analysis of Nitrogen-Purged Compartments within the Space Shuttle

To enter orbit, the Space Shuttle burns 1.8 million liters of liquid hydrogen combined with 0.8 million liters of liquid oxygen through three rocket engines mounted in the aft. NASA monitors the nitrogen-purged aft compartment for increased levels of hydrogen or oxygen in order to detect and determine the severity of a cryogenic fuel leak. Current monitoring is accomplished with a group of mass spectrometer systems located as much as 400 feet away from the Shuttle. It can take up to 45 seconds for gas to reach the mass spectrometer, which precludes monitoring for leaks in the final moments before liftoff (the orbiter engines are started at T-00:06 seconds). To remedy the situation, NASA is developing a small rugged mass spectrometer to be used as point-sensors around the Space Shuttle. As part of this project, numerous mass analyzer technologies are being investigated. Presented here are the preliminary results for one such technology, quadrupole ion trap mass spectrometry (QITMS). A compact QITMS system has been developed in-house at the University of Florida for monitoring trace levels of four primary gases, hydrogen, helium, oxygen, and argon, all in a nitrogen background. Since commercially available QITMS systems are incapable of mass analysis at m/z(exp 2), the home-built system is preferred for the evaluation of QITMS technology.

Ottens, Andrew K.↗

A Quadrupole Ion Trap Mass Spectrometer for Quantitative Analysis of Nitrogen-Purged Compartments within the Space Shuttle

To enter orbit the Space Shuttle burns 1.8 million liters of liquid hydrogen combined with 0.8 million liters of liquid oxygen through three rocket engines mounted in the aft. NASA monitors the nitrogen-purged aft compartment for increased levels of hydrogen or oxygen in order to detect and determine the severity of a cryogenic fuel leak. Current monitoring is accomplished with a group of mass spectrometer systems located as much as 400 feet away from the shuttle. It can take up to 45 seconds for gas to reach the mass spectrometer, which precludes monitoring for leaks in the final moments before liftoff (the orbiter engines are started at T-00:06 seconds). To remedy the situation, NASA is developing a small rugged mass spectrometer to be used as point-sources around the Space Shuttle.

Ottens, Andrew K.↗

Feasibility of using distributed chemical sensing for CO2 leakage monitoring

The feasibility study focused on the development of new fiber for distributed chemical sensing (DCS) that will allow direct detection of CO 2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CCS), to provide early warning for an incoming well failure and potential CO 2 leaking through it. We proposed using optical spectroscopy in optical fiber for direct detection of CO 2 . The main approach is based on Raman interrogation within gas-filled Holey Fibers (HoFs), so that the location and concentration of the gases would be provided simultaneously via backscattering. Additionally, Infrared (IR) Absorption Spectroscopy could also be used, and the architecture would be more discrete since interleaving with standard solid core fibers and Fiber Bragg Grating (FBG) sections is required to enable reflection to the I/O controls. The possible Raman length or the IR numbers of sections would be defined based on signal to noise ratio. The optical spectroscopy methodology would overcome current roadblocks to CCS, as fiber optics will allow for CO 2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure as the baseline of environment background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nano Sensors for Gas Detection in Space and Ground Support Applications

Personnel living in a space environment as well as technicians and engineers preparing spacecraft for launch can potentially be exposed to small amounts of hazardous gases. It is therefore important to be able to detect, identify and quantify the presence of a gas especially when its presence could lead to a fatal situation. The use of small and sensitive sensors can allow for the placement of these devices over a large area, thus allowing for a more precise and timely determination of a gas leak. ASRC Aerospace and its research partners are developing nano sensors for detection of various gases, including but not limited to: H2, NH3, N2O4, hydrazine and others. Initial laboratory testing has demonstrated the capability to detect the gases in concentrations lower than parts per million. Testing and development is continuing to improve the response and recovery times, to increase the sensitivity of the devices. Different coatings and electrodes are currently being evaluated to determine the optimum configuration of a variety of gases. The small footprint of the Nano sensors allows for several devices, each responsive in a different way to different gases, to be placed into a single substrate. Multiple devices embedded into a single substrate results in increased reliability and in a decrease for periodic calibrations. The use of different coatings will result in a small electronic nose capable of distinguishing between different gases. A multi-channel signal conditioner amplifier built on a small multi chip module is used to process the output of the sensors and to deliver a signal that can be remotely monitored. All the data is digitized and transmitted over the same cable pair used to power the amplifier. Multiple outputs can be connected to a single cable pair in order to minimize the added weight and expense associated with cabling in a spacecraft. The sensors will be run through a qualification process to evaluate their suitability for space applications we are expecting to have fully functional sensors available for initial field deployment and testing by the end of the year 2006.

Medelius, Pedro J.↗

Leak Location and Classification in the Space Shuttle Main Engine Nozzle by Infrared Testing

The Space Shuttle Main Engine (SSME) is composed of cooling tubes brazed to the inside of a conical structural jacket. Because of the geometry there are regions that can't be inspected for leaks using the bubble solution and low-pressure method. The temperature change due escaping gas is detectable on the surface of the nozzle under the correct conditions. The methods and results presented in this summary address the thermographic identification of leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera is used to record the minute temperature change associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner "hot wall" surface as the nozzle is pressurized. These images are enhanced by digitally subtracting a thermal reference image taken before pressurization, greatly diminishing background noise. The method provides a nonintrusive way of localizing the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation.

Russell, Samuel S.↗

Creating a Simulation Platform for Research and Development of Advanced Control Methods

Advanced nuclear reactors are essential to meet the changing energy requirements throughout both the United States and the rest of world. In addition to other features, they are designed to enable deployment in remote locations and operate in a fully (or near-fully) autonomous manner, which will require a new control paradigm. To realize autonomously operating reactors, the U.S. Department of Energy’s Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program conducts research and development into the enabling technologies and methods needed, including digital twins, machine learning, and risk modeling, in addition to various types of control methods. These technologies and methods are the key foundations needed to achieve fully autonomous systems. To develop and evaluate the technologies and methods necessary for achieving autonomous operations, it is critical to identify a software tool capable of integrating all the required elements. In surveying the available solutions, no software platforms were identified that could accomplish what was needed without introducing drawbacks. This challenge was the motivation for the current effort: to develop a software platform that can seamlessly integrate autonomouscontrol-enabling technologies and methods, allowing for accelerated research and development and transfer of ideas. The resulting platform, known as the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND), is Python-based, and leverages open-source tools to provide flexibility and facilitate building upon prior research. It is designed to enable advanced reactor developers to deploy and test advanced control technologies and methods coupled with their own models, solutions, and hardware. Given the substantial undertaking of developing such a platform, the current effort focused on laying down scalable, flexible software foundations and infrastructure, then demonstrating the platform via a use case. These foundations included developing generic modules, which contain the base variable and system blocks (the information and functional building blocks, respectively, that can be used to design a simulation) and the data handling and storage blocks needed to exchange information between the various blocks; as well as enablingtechnology-specific modules. This platform was evaluated via a use case, which was to simulate and control a process for the Microreactor Automated Control System (MACS) test bed. While MACS is not currently directly coupled to any specific microreactor physics, it was initially developed in concert with the Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor, and so the MARVEL physics are used here. As part of this use case, several enabling-technology-specific blocks within COMMAND were integrated, including a proportional integral derivative (PID) control block, a Reactor Excursion and Leak Analysis Program (RELAP5-3D) block, and an anomaly detection block. The COMMAND software platform was successfully demonstrated to achieve the scalability and flexibility objectives of this effort and will be leveraged by the program’s research efforts to advance state of the art control methodologies towards autonomous operations of advanced reactors. As new use cases are created and implemented, it is anticipated that COMMAND will continue to grow and evolve to meet new requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kryptonate Hydrogen Detection System (Final Report)

A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternatives to Silicon Rubber Thermal Barrier in RSRM Nozzle Joints

Thiokol Propulsion encountered a situation where gas path can form in the Filler material in joints between the phenolic in the Space Shuttle Reusable Solid Rocket Motor nozzle. An investigation determined that the method for injecting the filler material into the joint created a pressurized pocket of air that forced its way to the surface while the filler was curing. The path that the air took remained open some situations leaving a path for hot gas to get deep into the joint. The condition that created the gas path has been corrected by modifications to the manufacturing process, but a design solution that would reduce processing time is being pursued. A strip of open cell installed deep into the joint, can serve as a barrier to the Filler material. Testing indicates that the foam eliminates the pressure pocket, and does not prevent detection of leakage of the o-ring seals during leak test. Open cell foam does not have thermal resistance capability and mechanical structure, which would be required in the event of a gas path. A replacement to open cell foam is now being considered. Braided carbon fiber rope has the permeability characteristics of foam and it has thermal resistance characteristics as well. Braided carbon fiber rope (BCFR) has been tested in simulated joints in subscale rocket motor. Results of the testing indicate that braided carbon fiber rope can significantly reduce gas temperature by as much es 3000 F in a nozzle joint configuration. BCFR can be installed as a barrier to stop the joint filler material or it can used as the thermal barrier alone.

Totman, Peter D.↗

Detection of Intergranular Corrosion in Cold Plate Face Sheets

Cold plates are critical for cooling electronic systems in the shuttle. As a result of the environmental conditions in which they operate, water can condense between them and a support shelf. In some cases, this water results in intergranular corrosion in the face sheet. If the intergranular corrosion sufficiently penetrates the face sheet, a coolant leak could occur and jeopardize cold plate operation. This paper examines techniques for detecting and characterizing the intergranular corrosion, to enable recertification of cold plates that have been in operation for 15 plus years. Intergranular corrosion was artificially induced in the face sheets of a series of cold plate specimens using an electrochemical process. Some of the cold plate specimens were separated for destructive characterization of the extent of corrosion produced by the electrochemical process and to insure the induced corrosion was intergranular. The rest of the specimens were characterized nondestructively using several techniques. X-ray tomography and ultrasonic techniques provided the best indication of corrosion in these specimens and will be the focus of this paper. An x-ray tomography technique was shown to be the most effective technique for characterizing depth of the intergranular corrosion. From these measurements, corrosion profile maps were developed that were consistent with subsequent destructive evaluations of the specimens. This enabled the assessment of NDE (ondestructive evaluation) standards to evaluate the viability of other NDE techniques. Due to system constraints, a different technique must be used to inspect an entire cold plate. An ultrasonic technique was shown to be very reliable for detection of corrosion in the unbacked regions of the face sheet. The ultrasonic technique was performed in an alcohol bath to avoid additional corrosion during the NDE evaluation. A pulse echo technique that focuses on the RMS value of the signal is shown to be very sensitive to the presence of intergranular corrosion.

Winfree, William P.↗

Detection of X-Ray Pulsations from the Be/X-Ray Transient A 0535+26 During a Disc Loss Phase of the Primary

Using the RossiXTE experiment, we detect weak X-ray emission from the recurrent Be/X-ray transient A 0535+26 at a time when the optical counterpart V725 Tau displayed H.alpha in absorption, indicating the absence of a circumstellar disc. The X-ray radiation is strongly modulated at the 103.5-s pulse period of the neutron star, confirming that it originates from A 0535+26. The source is weaker than in previous quiescence detections by two orders of magnitude and should be in the centrifugal inhibition regime. We show that the X-ray luminosity cannot be due to accretion on to the magnetosphere of the neutron star. Therefore this detection represents a new state of the accreting pulsar. We speculate that the X-ray emission can be due to some matter leaking through the magnetospheric barrier or thermal radiation from the neutron star surface due to crustal heating. The detection of the X-ray source in the inhibition regime implies a reduced density in the outflow from the Be companion during its disc-less phase.

Negueruela, Ignacio↗

Autonomous Cryogenic Leak Detector for Improving Launch Site Operations

NASA, military, and commercial satellite users need launch services that are highly reliable, less complex, easier to test, and cost effective. This project has developed a tapered optical fiber sensor for detecting hydrogen. The invention involves incorporating chemical indicators on the tapered end of an optical fiber using organically modified silicate nanomaterials. The Hazardous Gas Detection Lab (HGDL) at Kennedy Space Center is involved in the design and development of instrumentation that can detect and qualify various mission-critical chemicals. Historically, hydrogen, helium, nitrogen, oxygen, and argon are the first five gases of HGDL focus. The use of these cryogenic fluids in the area of propulsion offers challenges. Due to their extreme low temperatures, these fluids induce contraction of the materials they contact, a potential cause of leakage. Among them, hydrogen is of particular concern. Small sensors are needed in multiple locations without adding to the structural weight. The most vulnerable parts of the engine are the connection flanges on the transfer lines, which have to support cycles of large thermal amplitude. The thermal protection of the engine provides a closed area, increasing the likelihood of an explosive atmosphere. Thus, even a small leak represents an unacceptable hazardous condition during loading operations, in flight, or after an aborted launch. Tapered fibers were first fabricated from 1/1.3-mm core/cladding (silica/ plastic) optical fibers. Typically a 1-ft (approx. 30- cm) section of the 1-mm fiber is cut from the bundle and marked with a pen into five 2-.-in. (.5.7-cm) sections. A propane torch is applied at every alternate mark to burn the jacket and soften the glass core. While the core is softening, the two ends of the fiber are pulled apart slowly to create fine tapers of .- to .-in. (.6- to 12-mm) long on the 1-mm optical fiber. Following this, the non-tapered ends of the fibers are polished to a 0.3-micron finish. Then these fibers were coated with indicators sensitive to hydrogen. The tapered hydrogen detection system with its unique flexibility is the only system that can be placed in many locations inside the vehicles and detect the exact location of leaks, saving millions of dollars for launch vehicle industries.

Goswami, Kisholoy↗

Detecting Airborne Mercury by Use of Polymer/Carbon Films

Films made of certain polymer/carbon composites have been found to be potentially useful as sensing films for detecting airborne elemental mercury at concentrations on the order of tens of parts per billion or more. That is to say, when the polymer/carbon composite films are exposed to air containing mercury vapor, their electrical resistances decrease by measurable amounts. Because airborne mercury is a health hazard, it is desirable to detect it with great sensitivity, especially in enclosed environments in which there is a risk of a mercury leak from lamps or other equipment. The present effort to develop polymerbased mercury-vapor sensors complements the work reported in NASA Tech Briefs Detecting Airborne Mercury by Use of Palladium Chloride (NPO- 44955), Vol. 33, No. 7 (July 2009), page 48 and De tecting Airborne Mer cury by Use of Gold Nanowires (NPO-44787), Vol. 33, No. 7 (July 2009), page 49. Like those previously reported efforts, the present effort is motivated partly by a need to enable operation and/or regeneration of sensors under relatively mild conditions more specifically, at temperatures closer to room temperature than to the elevated temperatures (greater than 100 C ) needed for regeneration of sensors based on noble-metal films. The present polymer/carbon films are made from two polymers, denoted EYN1 and EYN2 (see Figure 1), both of which are derivatives of poly-4-vinyl pyridine with amine functional groups. Composites of these polymers with 10 to 15 weight percent of carbon were prepared and solution-deposited onto the JPL ElectronicNose sensor substrates for testing. Preliminary test results showed that the resulting sensor films gave measurable indications of airborne mercury at concentrations on the order of tens of parts per billion (ppb) or more. The operating temperature range for the sensing films was 28 to 40 C and that the sensor films regenerated spontaneously, without heating above operating temperature (see Figure 2).

Shevade, Abhijit↗

An Engineered Minimal-Set Stimulus for Periodic Information Leakage Fault Detection on a RISC-V Microprocessor

Recent evaluations of counter-based periodic testing strategies for fault detection in Microprocessor (μP) have shown that only a small set of counters is needed to provide complete coverage of severe faults. Severe faults are defined as faults that leak sensitive information, e.g., an encryption key on the output of a serial port. Alternatively, fault detection can be accomplished by executing instructions that periodically test the control and functional units of the μP. In this paper, we propose a fault detection method that utilizes an ’engineered’ executable program combined with a small set of strategically placed counters in pursuit of a hardware Periodic Built-In-Self-Test (PBIST). We analyze two distinct methods for generating such a binary; the first uses an Automatic Test Generation Pattern (ATPG)-based methodology, and the second uses a process whereby existing counter-based node-monitoring infrastructure is utilized. We show that complete fault coverage of all leakage faults is possible using relatively small binaries with low latency to fault detection and by utilizing only a few strategically placed counters in the μP.

42 ENGINEERING↗