Simultaneous determination of electrical conductivity and thickness of nonmagnetic metallic foils using two-sided multifrequency eddy current techniques

Here, in this paper, we describe a simple method for performing multifrequency eddy current characterization of free-standing uniform-thickness metallic foils using a forked inductive coil arrangement. The method involves measuring the mutual inductance between two coils when a foil is present between the coils, and when it is not present; the ratio of these mutual inductances is compared with an analytical solution, and foil conductivity, thickness, and sheet resistance are simultaneously estimated using numerical inversion and least-squares fitting. This method was used to characterize 34 non-ferrous metallic samples with thicknesses between 50 and 640 μm and with conductivities between 0.8 × 10 7 and 5.8 × 10 7 S/m. The estimated thicknesses from eddy current characterization agreed well with those measured using confocal optical techniques; the two approaches agreed to within 1 μm for samples that were thinner than 200 μm, and to within 0.5% for samples that had a thickness of 200 μm or greater. The estimated conductivities from eddy current characterization were in close agreement with expected values, given knowledge of the materials used. A particular strength of this approach is that the instrumentation needed is broadly available in research and development laboratories and the associated fixturing is easy to manufacture and assemble. A calibration procedure is described that can be used to reduce errors from geometric uncertainties. This calibration requires a sample that has only a known conductivity or thickness; both do not need to be known. The method described herein is likely extensible to conductivities and thickness well outside the ranges measured as part of this work.

47 OTHER INSTRUMENTATION↗

Canister Centerline Cooling Experiments for DPF5-336 Reference Material Made with ERV3b Salt Simulant

This report provides experimental details and results on the elemental distributions (compositions), crystalline/amorphous phase distribution, and microstructures for DPF5-336 reference materials made with ERV3b salt that were subjected to the canister centerline cooling (CCC) heat treatment process. To fabricate these materials, ammonium dihydrogen phosphate was mixed with ERV3b salt simulant and a dechlorination procedure was run in the generation-2 dechlorinator at the Pacific Northwest National Laboratory up to 600°C in an alumina crucible. After the dechlorination process, the product was removed from the crucible, lightly crushed, loaded into a new alumina crucible, Fe 2 O 3 was added, and this was vitrified at 1100°C for 1 hour and quenched. The quenched material was mostly amorphous but showed some small diffraction peaks attributed to Li 3 Fe 2 (PO 4 ) 3 . This quenched material was ground to a fine particle size in a milling chamber, and this was subjected to the CCC cooling profile in duplicate within alumina and fused quartz crucibles. The CCC experiment is designed to simulate the slowest cooling profile (the vertical centerline) of a 0.61-m diameter canister where the slower cooling profile often results in the production of a variety of different crystalline phases upon formation of which result in a residual glass of unknown composition and properties. The information gleaned from these types of experiments will lead to improved composition-property predictions for materials with similar compositions. The results of the alumina and fused quartz experiments show different microstructures but similar diffraction patterns providing evidence of similar crystalline phases being present in each sample. Both samples had monazite [i.e., (Ce,Nd)PO 4 ] and mixtures of phases containing P, Fe, and alkali metal elements. This report completes the milestone M4FT-23PN030104042 with details provided in Appendix B.

36 MATERIALS SCIENCE↗

Relative toxicity of pyrolysis products of some foams and fabrics

A limited number of foams and fabrics was evaluated in the course of developing test procedures for determining the relative toxicity of materials. The principal variable studied, heating rate, did not affect the relative ranking of the materials tested. Two pyrolysis test procedures using the same basic approach but employing different sample weights, chamber volumes, laboratory animals, heating rates, and upper temperature limits, resulted in identical rankings of relative toxicity. The data obtained show that modification of conventional flexible polyurethane foams with flame retardants to comply with California upholstered furniture flammability regulations seems to consistently reduce toxicity under pyrolysis conditions.

Hilado, C. J.↗

Digital enhancement of X-rays for NDT

Report is "cookbook" for digital processing of industrial X-rays. Computer techniques, previously used primarily in laboratory and developmental research, have been outlined and codified into step by step procedures for enhancing X-ray images. Those involved in nondestructive testing should find report valuable asset, particularly is visual inspection is method currently used to process X-ray images.

Butterfield, R. L.↗

Calibration procedures for measurement of reflectance factor in remote sensing field research

A means by which measurements of the optical properties of crops and soils can be knowledgeably compared from site to site and instrument to instrument is presented in detail. The definition of bidirectional reflectance factor is reviewed and discussed. Procedures for field implementation are illustrated and discussed. Spectral and goniometric properties of laboratory and field reference surfaces and typical environmental subjects serve as a basis for analysis of uncertainties introduced by differing illumination conditions. Results of a comparison of the performance of three spectrometer systems are presented and discussed. It is concluded that intelligent use of the bidirectional reflectance factor technique is an accurate and practical means to obtain the spectral, optical properties of crops and soils needed for advancements in agricultural remote sensing.

Robinson, B. F.↗

Scanner for measuring fine sea-surface structures

An optical scanner using the principle of light reflection has been designed for determining directional slope distributions of the wind-disturbed water surface. The instrument has been tested successfully in the laboratory and could be used in the field. Some sample results along with procedures for data analysis are also presented.

Wu, J.↗

Calibration procedures for measurement of reflectance factor in remote sensing field research

A means by which measurements of the optical properties of crops and soils can be knowledgeably compared from site to site and instrument to instrument is presented in detail. The definition of bidirectional reflectance factor is reviewed and discussed. Procedures for field implementation are illustrated and discussed. Spectral and goniometric properties of laboratory and field reference surfaces are given. It is concluded that intelligent use of the bidirectional reflectance factor technique is an accurate and practical means to obtain the spectral, optical properties of crops and soils needed for advancements in agricultural remote sensing.

Robinson, B. F.↗

Plume spectrometry for liquid rocket engine health monitoring

An investigation of Space Shuttle Main Engine (SSME) testing failures identified optical events which appeared to be precursors of those failures. A program was therefore undertaken to detect plume trace phenomena characteristic of the engine and to design a monitoring system, responsive to excessive activity in the plume, capable of delivering a warning of an anomalous condition. By sensing the amount of extraneous material entrained in the plume and considering engine history, it may be possible to identify wearing of failing components in time for a safe shutdown and thus prevent a catastrophic event. To investigate the possibilities of safe shutdown and thus prevent a monitor to initiate the shutdown procedure, a large amount of plume data were taken from SSME firings using laboratory instrumentation. Those data were used to design a more specialized instrument dedicated to rocket plume diagnostics. The spectral wavelength range of the baseline data was about 220 nanometers (nm) to 15 micrometer with special attention given to visible and near UV. The data indicates that a satisfactory design will include a polychromator covering the range of 250 nM to 1000 nM, along with a continuous coverage spectrometer, each having a resolution of at least 5A degrees. The concurrent requirements for high resolution and broad coverage are normally at odds with one another in commercial instruments, therefore necessitating the development of special instrumentation. The design of a polychromator is reviewed herein, with a detailed discussion of the continuous coverage spectrometer delayed to a later forum. The program also requires the development of applications software providing detection, variable background discrimination, noise reduction, filtering, and decision making based on varying historical data.

Powers, William T.↗

Navigation accuracies for GPS demonstration on Topex/Poseidon

When Topex/Poseidon, is launched in June 1992, the joint United States/French oceanographic satellite mission will carry a developmental Global Positioning System (GPS) receiver on board to support the planned GPS demonstration experiment. The navigation operations aspect of the demonstration will develop software and operational procedures for the GPS Data Processing Facility (GDPF) at NASA's Jet Propulsion Laboratory. This paper presents simulations and covariance analysis of operational scenarios in support of the GDPF. Multi-orbit filter techniques using GPS carrier phase and P-code pseudo-range are studied both to tune the filter parameters and to determine feasible arc lengths for use in operations. In addition, a baseline operational scenario is presented with performance results given in terms of end-to-end processing times and computational loading based on a prototype version of the operational software.

Williams, B. G.↗

Standard Method For Radiation Tests Of Liquids

Simple procedure provides standard method for radiation tests of liquids. Assures identical handling and dosage so data from different test laboratories compared reliably. Pair of glass vials, joined by frangible neck and equipped with valves, used. Third vial also used. Filled with control specimen and not irradiated. Developed for measuring properties of liquids for use in radiation-resistant liquid-dielectric capacitors, procedure used for any of variety of liquids proposed for use in high-radiation environment - in x-ray and particle-accelerating machines and nuclear reactors, for example.

Bouquet, Frank L.↗

Site 200 #1400 Block Area New Trailers Project, Soil Sampling and Analysis Plan/Quality Assurance Plan

Lawrence Livermore National Laboratory's (LLNL) Project Management Office (PMO) is proposing to install a series of modular trailers and install associated underground utilities in the 1400 Block at the Livermore Site. This Sampling and Analysis Plan (SAP) outlines the processes and procedures to collect environmental and geotechnical soil samples from the project area and to send the samples to the appropriate laboratory or laboratories for analysis or testing. The resulting environmental laboratory data will determine whether excavated soils can be reused on the project, or which type of landfill or landfills the soils may be sent for disposal. This SAP has been prepared and is organized to be consistent with LLNL's Soils Screening and Management Plan (SSMP) (LLNL, 2019), as well as the U.S. Environmental Protection Agency's (EPA) Data Quality Objectives programs (EPA, 2006).

54 ENVIRONMENTAL SCIENCES↗

Some comparison of ECMWF 3b and GFDL 3b analyses in the tropics

Owing to the problems that data assimilation procedures have in analyzing data in the tropics and to the apparent differences in the descriptions of the European Center for Medium Range Weather Forecasts (ECMWF) and Geophysical Fluid Dynamics Laboratory (GFDL) assimilation suites, a brief comparison was done of the resulting analyses in the tropics. Three cases each were selected for Standard Operating Procedures 1 and 2 at the 200 and 850 mb levels, the wind fields for 25 deg N 25 deg S were partitioned into a rotational and divergent component, and various statistics of each were calculated.

Julian, P. R.↗

Demonstration of Algorithm for Sensor Placement Optimization using Simulation Data

This deliverable reports FY26 progress in advancing a neural-network-based Green’s-function framework for reconstructing neutron-flux distributions from ex-core measurements and for translating reconstruction requirements into a practical detector-layout strategy. Building on the FY25 formulation, the present work had two main objectives: (1) refine and re-evaluate the reconstruction methodology on an updated Purdue University Reactor Number One (PUR-1) model, and (2) develop a systematic, Green’s-function-guided procedure for boundary detector placement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing of Composite Fan Vanes With Erosion-Resistant Coating Accelerated

The high-cycle fatigue of composite stator vanes provided an accelerated life-state prior to insertion in a test stand engine. The accelerated testing was performed in the Structural Dynamics Laboratory at the NASA Glenn Research Center under the guidance of Structural Mechanics and Dynamics Branch personnel. Previous research on fixturing and test procedures developed at Glenn determined that engine vibratory conditions could be simulated for polymer matrix composite vanes by using the excitation of a combined slip table and electrodynamic shaker in Glenn's Structural Dynamics Laboratory. Bench-top testing gave researchers the confidence to test the coated vanes in a full-scale engine test.

Bowman, Cheryl L.↗

Description of 103 Cases of Hypobaric Sickness from NASA-sponsored Research

One hundred and three cases of hypobaric decompression sickness (DCS) are documented, with 6 classified as Type II DCS. The presence and grade of venous gas emboli (VGE) are part of the case descriptions. Cases were diagnosed from 731 exposures in 5 different altitude chambers from 4 different laboratories between the years 1982 and 1999. Research was funded by NASA to develop operational prebreathe (PB) procedures that would permit safe extravehicular activity from the Space Shuttle and International Space Station using an extravehicular mobility unit (spacesuit) operated at 4.3 psia. Both vehicles operate at 14.7 psia with an "air" atmosphere, so a PB procedure is required to reduce nitrogen partial pressure in the tissues to an acceptable level prior to depressurization to 4.3 psia. Thirty-two additional descriptions of symptoms that were not diagnosed as DCS together with VGE information are also included. The information for each case resides in logbooks from 32 different tests. Additional information is stored in the NASA Decompression Sickness Database and the Prebreathe Reduction Protocol Database, both maintained by the Environmental Physiology Laboratory at the Johnson Space Center. Both sources were reviewed to provide the narratives that follow.

Conkin, Johnny↗

Analytical control test plan and microbiological methods for the water recovery test

Qualitative and quantitative laboratory results are important to the decision-making process. In some cases, they may represent the only basis for deciding between two or more given options or processes. Therefore, it is essential that handling of laboratory samples and analytical operations employed are performed at a deliberate level of conscientious effort. Reporting erroneous results can lead to faulty interpretations and result in misinformed decisions. This document provides analytical control specifications which will govern future test procedures related to all Water Recovery Test (WRT) Phase 3 activities to be conducted at the National Aeronautics and Space Administration/Marshall Space Flight Center (NASA/MSFC). This document addresses the process which will be used to verify analytical data generated throughout the test period, and to identify responsibilities of key personnel and participating laboratories, the chains of communication to be followed, and ensure that approved methodology and procedures are used during WRT activities. This document does not outline specifics, but provides a minimum guideline by which sampling protocols, analysis methodologies, test site operations, and laboratory operations should be developed.

Traweek, M. S.↗

An interlaboratory comparison of mid-infrared spectra acquisition: Instruments and procedures matter

Diffuse reflectance spectroscopy has been extensively employed to deliver timely and cost-effective predictions of a number of soil properties. However, although several soil spectral laboratories have been established worldwide, the distinct characteristics of instruments and operations still hamper further integration and interoperability across mid-infrared (MIR) soil spectral libraries. In this study, we conducted a large-scale ring trial experiment to understand the lab-to-lab variability of multiple MIR instruments. By developing a systematic evaluation of different mathematical treatments with modeling algorithms, including regular preprocessing and spectral standardization, we quantified and evaluated instruments' dissimilarity and how this impacts internal and shared model performance. We found that all instruments delivered good predictions when calibrated internally using the same instruments' characteristics and standard operating procedures by solely relying on regular spectral preprocessing that accounts for light scattering and multiplicative/additive effects, e.g., using standard normal variate (SNV). When performing model transfer from a large public library (the USDA NSSCKSSL MIR library) to secondary instruments, good performance was also achieved by regular preprocessing (e. g., SNV) if both instruments shared the same manufacturer. However, significant differences between the KSSL MIR library and contrasting ring trial instruments responses were evident and confirmed by a semi-unsupervised spectral clustering. For heavily contrasting setups, spectral standardization was necessary before transferring prediction models. Non-linear model types like Cubist and memory-based learning delivered more precise estimates because they seemed to be less sensitive to spectral variations than global partial least square regression. In summary, the results from this study can assist new laboratories in building spectroscopy capacity utilizing existing MIR spectral libraries and support the recent global efforts to make soil spectroscopy universally accessible with centralized or shared operating procedures.

58 GEOSCIENCES↗

Optimizing the use of pressurized bladders for the assembly of HL-LHC MQXFB magnets

The use of pressurized bladders for stress control of superconducting magnets was firstly proposed at Lawrence Berkeley National Laboratory in the early 2000s. Since then, the so-called ‘bladders and keys’ procedure has become one of the reference techniques for the assembly of high-field accelerator magnets and demonstrators. Exploiting the advantages of this method is today of critical importance for Nb$_{3}$Sn-based accelerator magnets, whose production requires the preservation of tight stress targets in the superconducting coils to limit the effects of the strain sensitivity and brittleness of the conductor. The present manuscript reports on the results of an experimental campaign focused on the optimization of the ‘bladders and keys’ assembly process in the MQXFB quadrupoles. These 7.2 m long magnets shall be among the first Nb$_{3}$Sn cryomagnets to be installed in a particle accelerator as a part of the High Luminosity upgrade of the LHC. One of the main practical implications of the bladders technique, especially important when applied to long magnets like MQXFB, is that to insert the loading keys, the opening of a certain clearance in the support structure is required. The procedure used so far for MQXF magnets involved an overstress in the coils during bladder inflation. The work presented here shows that such an overshoot can be eliminated thanks to additional bladders properly positioned in the structure. This optimized method was validated in a short model magnet and in a full-length mechanical model, becoming the new baseline for the series production at CERN. Furthermore, the results are supported by numerical predictions using finite element models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗