Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LANSCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Beam dynamics in independent phased cavities

Linear accelerators containing the sequence of independently phased cavities with constant geometrical velocity along each structure are widely used in practice. The chain of cavities with identical cell lengths is utilized within a certain beam velocity range, with subsequent transformation to the next chain with higher cavity velocity. Design and analysis of beam dynamics in this type of accelerator are usually performed using numerical simulations. A full theoretical description of particle acceleration in an array of independent phased cavities has not been developed. In the present paper, we provide an analytical treatment of beam dynamics in such linacs employing Hamiltonian formalism. We begin our analysis with an examination of beam dynamics in an equivalent traveling wave of a single cavity, propagating within accelerating section with constant phase velocity. We then consider beam dynamics in arrays of cavities, utilizing an effective traveling wave propagating along with the whole accelerator with the velocity of synchronous (reference) particle. The analysis concluded with the determination of the matched beam conditions. Finally, we present a beam dynamics study in 805 MHz Coupled Cavity Linac of the LANSCE accelerator facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

World's Finest Gold Specimen Probed With Los Alamos Neutrons

Using neutron characterization techniques a team of scientists have peered inside one of the most unique examples of wire gold, understanding for the first time the specimen's structure and possible formation process. The 263 gram, 12 centimeter tall specimen, known as the Ram's Horn, belongs to the collection of the Mineralogical and Geological Museum Harvard University (MGMH). "Almost nothing other than the existence of the specimen is known about wire gold," said Sven Vogel, a physicist at Los Alamos National Laboratory's neutron science center, LANSCE, a half-mile-long particle accelerator that provides high- and low-energy protons and neutrons for a wide variety of scientific research. Found in 1887 at the Ground Hog Mine in Red Cliff, Colorado, mysteriously shaped like a twisted bunch of wires instead of the more recognizable golden nugget, the Ram's Horn has baffled mineralogists since its discovery. The unknown: what is its fundamental structure and how did it form? "Some native metals, a metal or metal alloy found in nature can occur in what is called wire morphology," said John Rakovan, Professor of Mineralogy at Miami University in Ohio. "Much more common in silver, the wire morphology is rarely seen in gold samples and this specimen is without question the finest known example."

58 GEOSCIENCES↗

Achieving Transformational Materials Performance in a New Era of Science

The inability of current materials to meet performance requirements is a key stumbling block for addressing grand challenges in energy and national security. Fortunately, materials research is on the brink of a new era - a transition from observation and validation of materials properties to prediction and control of materials performance. In this talk, I describe the nature of the current challenge, the prospects for success, and a specific facility concept, MaRIE, that will provide the needed capabilities to meet these challenges, especially for materials in extreme environments. MaRIE, for Matter-Radiation Interactions in Extremes, is Los Alamos' concept to realize this vision of 21st century materials research. This vision will be realized through enhancements to the current LANSCE accelerator, development of a fourth-generation x-ray light source co-located with the proton accelerator, and a comprehensive synthesis and characterization facility focused on controlling complex materials and the defect/structure link to materials performance.

36 MATERIALS SCIENCE↗

MW Spallation Neutron Sources for Fusion Materials Testing

Dr. Donald Rej of Los Alamos National Laboratory presents an overview of issues, needs, and performance gaps related to materials testing and how they are being addressed at their facility. Current projects such as the Los Alamos Neutron Science Center (LANSCE) and Matter-Radiation Interactions in Extremes (MaRIE) are also discussed.

36 MATERIALS SCIENCE↗

Preparation of a one-curie 171Tm target for the Detector for Advanced Neutron Capture Experiments (DANCE)

Roughly one curie of 171Tm (t1/2=1.92a) has been produced and purified for the purpose of making a nuclear target for the first measurements of its neutron capture cross section. Target preparation consisted of three key steps: (1) material production; (2) separation and purification; and (3) electrodeposition onto a suitable backing material. Approximately 1.5 mg of the target material (at the time of separation) was produced by irradiating roughly 250 mg of its stable enriched 170Er lanthanide neighbor with neutrons at the ILL reactor in France. This production method resulted in a “difficult-to-separate” 1:167 mixture of near-neighboring lanthanides, Tm and Er. Separation and purification was accomplished using high-performance liquid chromatorgraphy (HPLC), with a proprietary cation exchange column (Dionex, CS-3) and alpha-hydroxyisobutyric acid (a-HIB) eluent. This technique yielded a final product of ~95% purity with respect to Tm. A portion (20 ug) of the Tm was electrodeposited on thin Be foil and delivered to the Los Alamos Neutron Science CEnter (LANSCE) for preliminary analysis of its neutron capture cross section using the Detector for Advanced Neutron Capture Experiments (DANCE). This paper discusses the major hurdles associated with the separation and purification step including, scale-up issues related to the use of HPLC for material separation and purification of the target material from a-HIB and 4-(2-pyridylazo)resorcinol (PAR) colorant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preparation of thin arsenic and radioarsenic targets for neutron capture studies

A simple method for the electrodeposition of elemental arsenic (As) on a metal backing from aqueous solutions has been developed. The method was successfully applied to stable As (As-75). Thin (2.5 mg {center_dot} cm{sup -2}) coherent, smooth layers of the metalloid on Ti foils (2.5 {micro}m thickness) were obtained. Electrodeposits served as targets for {sup 75}As(n,{gamma}) {sup 76}As neutron capture experiments at Los Alamos Neutron Science Center (LANSCE). Respective {sup 73}As(n,{gamma}) {sup 74}As experiments are planned for the near future, and {sup 73}As targets will be prepared in a similar fashion utilizing the introduced electrodeposition method. The preparation of an {sup 73}As (half-life 80.3 d) plating bath solution from proton irradiated germanium has been demonstrated. Germanium target irradiation was performed at the Los Alamos Isotope Production Facility (IPF).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Planar Biaxial Experiment Platform for In Situ High-Energy Diffraction Studies

In this work, an experimental platform for multiscale studies of materials subjected to plane stress loads is presented. Specifically, a planar biaxial mechanical load frame with four independent hydraulic actuators capable of applying arbitrary loading paths and ratios of tension and compression was designed and built for in situ diffraction experimentation. The load frame is integrated for use at the Argonne National Laboratory Advanced Photon Source (APS) synchrotron, Sector 1, 1-ID-E endstation and the Los Alamos Neutron Science Center (LANSCE) spallation neutron source, Spectrometer for Materials Research at Temperature and Stress (SMARTS) instrument. Cruciform specimen geometries were designed to experience loading ratios in the gauges commensurate with those applied at the grips, and to minimize interference with diffracted X-rays and neutrons. The finite element models used to design the cruciform specimen geometries were experimentally validated using stereo digital image correlation measurements. This complete planar biaxial in situ diffraction platform provides a new capability for studying multiaxial micromechanics of crystalline materials (e.g., elastic, slip, twinning, phase transformation) and their dependencies on grain size, location, texture, and neighborhood characteristics. The coupling with far-field high energy diffraction microscopy (ff-HEDM) for grain-by-grain measurements provides an additional benefit; provided crystal elastic constants of a material are known, it enables the direct measurement of local and average stress tensors in the gauge sections of cruciform specimens, resolving a long outstanding challenge of planar biaxial mechanical testing.

36 MATERIALS SCIENCE↗

Dose dependence of mechanical properties in tantalum and tantalum alloys after low temperature irradiation

The dose dependence of mechanical properties was investigated for tantalum and tantalum alloys after low temperature irradiation. Miniature tensile specimens of three pure tantalum metals, ISIS Ta, Aesar Ta1, Aesar Ta2, and one tantalum alloy, Ta-1W, were irradiated by neutrons in the High Flux Isotope Reactor (HFIR) at ORNL to doses ranging from 0.00004 to 0.14 displacements per atom (dpa) in the temperature range 60 C 100 oC. Also, two tantalum-tungsten alloys, Ta-1W and Ta-10W, were irradiated by protons and spallation neutrons in the LANSCE facility at LANL to doses ranging from 0.7 to 7.5 dpa and from 0.7 to 25.2 dpa, respectively, in the temperature range 50 C 160 oC. Tensile tests were performed at room temperature and at 250oC at nominal strain rates of about 10-3 s-1. All neutron-irradiated materials underwent progressive irradiation hardening and loss of ductility with increasing dose. The ISIS Ta experienced embrittlement at 0.14 dpa, while the other metals retained significant necking ductility. Such a premature embrittlement in ISIS Ta is believed to be because of high initial oxygen concentrations picked up during a pre-irradiation anneal. The Ta-1W and Ta-10W specimens irradiated in spallation condition experienced prompt necking at yield since irradiation doses for those specimens were high ( 0.7 dpa). At the highest dose, 25.2 dpa, the Ta-10W alloy specimen broke with little necking strain. Among the test materials, the Ta-1W alloy displayed the best combination of strength and ductility. The plastic instability stress and true fracture stress were nearly independent of dose. Increasing test temperature decreased strength and delayed the onset of necking at yield.

36 MATERIALS SCIENCE↗

Cavitation damage prediction for spallation target vessels by assessment of acoustic vibration

Liquid-mercury target systems for MW-class spallation neutron sources are being developed around the world. Proton beams are used to induce the spallation reaction. At the moment the proton beam hits the target, pressure waves are generated in the mercury because of the abrupt heat deposition. The pressure waves interact with the target vessel leading to negative pressure that may cause cavitation along the vessel wall. In order to estimate the cavitation erosion, i.e. the pitting damage formed by the collapse of cavitation bubbles, off-beam tests were performed by using an electric magnetic impact testing machine (MIMTM), which can impose equivalent pressure pulses in mercury. The damage potential was defined based on the relationship between the pitting damage and the time-integrated acoustic vibration induced by impact due to the bubble collapses. Additionally, the damage potential was measured in on-beam tests carried out by using the proton beam at WNR (Weapons Neutron Research) facility in Los Alamos Neutron Science Center (LANSCE). In this paper, the concept of the damage potential, the relationship between the pitting damage formation and the damage potential both in off-beam and on-beam tests is shown.

acoustic↗

Numerical study on pressure wave propagation in a mercury loop

On-beam tests were carried out at the Los Alamos Neutron Science Center Weapons Neutron Research (LANSCE WNR) facility in June 2005 to investigate pressure wave mitigation in mercury targets for the MW-class spallation neutron sources under international collaboration between US Spallation Neutron Source (SNS) and Japanese Spallation Neutron Source (JSNS). A mercury loop was used for the target, a so-called In-Beam Bubbling Test Loop (IBBTL). The loop consists of the rectangular pipe of 25 mm x 50 mm^2 in cross section, 1.5 mm in wall thickness and 2 m in total length approximately. The SNS team set 8 strain sensors on the pipe wall to measure the strain propagation caused by the pressure wave. The maximum strain appeared at 350 mm apart from the proton-bombarded point at 5.5 ms after the proton bombardment. It is known that the propagation velocity of the pressure wave in mercury is ca. 1500 m/s and that of the stress wave in stainless steel is ca. 5000 m/s. However, the apparent wave propagation velocity in the IBBTL was lower than those velocities and was observed to be 65 m/s. Numerical analysis was carried out to understand the strain propagation in the pipe wall of the IBBTL. Numerical results showed that the maximum strain at 350 mm apart from the beam spot appeared at 5.5 ms after proton bombardment in good agreement with experimental results.

mercury↗

Proton irradiation damage of an annealed Alloy 718 beam window

Mechanical testing and microstructural analysis was performed on an Alloy 718 window that was in use at the Los Alamos Neutron Science Center (LANSCE) Isotope Production Facility (IPF) for approximately 5 years. It was replaced as part of the IPF preventive maintenance program. The window was transported to the Wing 9 hot cells at the Chemical and Metallurgical Research (CMR) LANL facility, visually inspected and 3-mm diameter samples were trepanned from the window for mechanical testing and microstructural analysis. Shear punch testing and optical metallography was performed at the CMR hot cells. The 1-mm diameter shear punch disks were cut into smaller samples to further reduce radiation exposure dose rate using Focus Ion Beam (FIB) and microstructure changes were analyzed using a Transmission Electron Microscopy (TEM). Irradiation doses were determined to be ~0.2–0.7 dpa (edge) to 11.3 dpa (peak of beam intensity) using autoradiography and MCNPX calculations. The corresponding irradiation temperatures were calculated to be ~34–120 °C with short excursion to be ~47–220 °C using ANSYS. Mechanical properties and microstructure analysis results with respect to calculated dpa and temperatures show that significant work hardening occurs but useful ductility still remains. The hardening in the lowest dose region (~0.2–0.7 dpa) was the highest and attributed to the formation of γ" precipitates and irradiation defect clusters/bubbles whereas the hardening in the highest dose region (~11.3 dpa) was lower and attributed mainly to irradiation defect clusters and some thermal annealing.

36 MATERIALS SCIENCE↗

High temperature neutron diffraction investigation of U 3 Si 2

The U-Si system is actively undergoing studies due to its promise as a component of an accident tolerant nuclear fuel. In this work, the crystal structure of the U 3 Si 2 compound in the U-Si system was investigated as a function of temperature from room temperature to 1298 K for a sample of approximately 42.02 at.% Si composition and 1373 K for a sample with approximately 42.10 at.% Si using high temperature time-of-flight neutron diffraction on the High-Pressure Preferred Orientation (HIPPO) diffractometer at Los Alamos Neutron Science Center (LANSCE). The simultaneous Rietveld refinement of five histograms from the five HIPPO detector backs (40°, 60°, 90°, 120°, and 145°) provided datasets for the lattice parameters, anisotropic atomic displacement parameters, and atomic positions as a function of temperature. To explore the possibility of a homogeneity range, two sample compositions were analyzed, a 40.02 at.% Si (near stoichiometric) and a potentially hyperstoichiometric (40.10 at.% Si) sample. While minor differences in the anisotropic atomic displacement parameters between the two samples were observed, over the entire investigated temperature range no additional phases were found indicative of a single phase sample and the ability of the U 3 Si 2 compound to accommodate nonstoichiometry, suggesting that the U 3 Si 2 compound is not a line compound confirming previous determinations. However, the differences observed in the average coefficient of linear thermal expansion identified between the two compositions warrant future investigation.

36 MATERIALS SCIENCE↗

Yttrium ENDF/B-VII Data from Theory and LANSCE/GEANIE Measurements and Covariances Estimated using Bayesian and Monte-Carlo Methods

Yttrium plays an important role as a radiochemical dosimetry detector for determining high energy 14 MeV neutron fluences, through measurement of (n,2n) activation products. The total (n,2n) cross section is known rather well from extensive activation measurements on the stable {sup 89}Y isotope, and from a previous activation measurement on the unstable {sup 88}Y ground state. However, until now the branching ratios to the ground state and excited isomers in {sup 88}Y via the {sup 89}Y (n,2n) reaction were not well known, and furthermore, uncertainty estimates were not available for these cross sections and branching ratios. This paper describes how gamma-ray transitions between states in (n,2n) and (n,n') reactions measured using the GEANIE detector at Los Alamos' LANSCE facility, together with theory predictions using the GNASH code, enable us to determine these quantities for the ENDF/B-VII evaluation. A previous measurement by Dietrich, at Livermore, provided important complementary information to the GEANIE analysis. We describe an uncertainty quantification analysis that uses the GNASH-KALMAN approach to evaluate cross sections for the {sup 89}Y (n,2n) population of the {sup 88}Y ground state and two meta-stable isomers (m1 and m2), along with their uncertainties. Our new results agree with Arthur's historic Los Alamos evaluated cross sections within a few percent below 15 MeV (with larger differences above 15 MeV). The (n,2n) cross sections to the {sup 88}Y ground state and m1, m2 isomers impact the average {sup 88}Y(n,2n){sup 87}Y cross section at leading-order; we determine this 14.1 MeV average cross section {sup 88}Y(n,2n){sup 87}Y = 1107 mb ({+-} 4%), which agrees with the value obtained from Arthur's evaluation to 0.7%. An alternative method to predict cross sections, uncertainties, and covariance data, is described that uses the European TALYS reaction modeling code and a Backward-Forward Monte-Carlo uncertainty quantification technique. This approach uses a microscopic optical model, together with Hauser-Feshbach and preequilibrium reaction mechanisms, and the underlying model parameters and their uncertainties and correlations are determined through a Monte-Carlo filtering method based on comparisons with measured cross section data. We compare the results obtained using this approach with the GNASH-KALMAN method. The evaluated cross sections are rather similar in the two approaches. We show how the uncertainty information, as embodied in the resulting covariance matrices, is also qualitatively similar in both approaches.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluated Iridium, Yttrium, and Thulium Cross Sections and Integral Validation Against Critical Assembly and Bethe Sphere Measurements

We describe new dosimetry (radiochemical) ENDF evaluations for yttrium, iridium, and thulium. These LANL2006 evaluations were based upon measured data and on nuclear model cross section calculations. In the case of iridium and yttrium, new measurements using the GEANIE gamma-ray detector at LANSCE were used to infer (n,xn) cross sections, the measurements being augmented by nuclear model calculations using the GNASH code. The thulium isotope evaluations were based on GNASH calculations and older measurements. The evaluated cross section data are tested through comparisons of simulations with measurements of reaction rates in critical assemblies and in Bethe sphere (sometimes called Wyman sphere) integral experiments. Two types of Bethe sphere experiments were studied - a LiD experiment that had a significant component of 14 MeV neutrons, and a LiD-U experiment that additionally had varying amounts of fission neutrons depending upon the location. These simulations were performed with the MCNP code using continuous energy Monte Carlo, and because the neutron fluences can be modeled fairly accurately by MCNP at different locations in these assemblies, the comparisons provide a valuable validation test of the accuracy of the evaluated cross sections and their energy dependencies. The MCNP integral reaction rate validation testing for the three detectors yttrium, iridium, and thulium, in the LANL2006 database is summarized as follows: (1) (n,2n)near 14 MeV: In 14 MeV-dominated locations (the LiD Bethe spheres and the outer regions of the LiD-U Bethe spheres), the (n,2n) products are modeled very well for all three detectors, suggesting that the evaluated {sup 89}Y(n,2n), {sup 191}Ir(n,2n), and {sup 169}Tm(n,2n) cross sections are accurate to better than about 5% near 14 MeV; (2) (n,2n)near threshold: In locations that have a significant number of fission spectrum neutrons or downscattered neutrons from 14 MeV inelastic scattering (the central regions of the LiD-U spheres and the fast critical assemblies), the (n,2n) products are overpredicted by 5-30 % for the three detectors, suggesting either the threshold region (n,2n) cross sections are too high, or that the MCNP-simulated neutron flux is too large for neutron energies above about 8 MeV; (3) Capture: The capture products for yttrium are modeled accurately for the LiD Bethe spheres, but are underpredicted by about 20% for the LiD-U Bethe spheres and the critical assemblies; for iridium-191 they are predicted accurately in the critical assemblies; and for thulium they are generally overpredicted by 10-30 %; (4) Inelastic scattering in iridium: The evaluated {sup 193}Ir(n,n{sup '}){sup 193m}Ir cross section performs well over a very wide range of neutron spectra (where the 193m/190 spectrum hardness index varies by over three orders of magnitude), the differences between simulation and experiment typically being better than 10-15%; (5) Iridium 193m/190 spectrum hardness index: Our simulations reproduce the measured 193m/190 data typically to better than 10-20% over three orders of magnitude in the 193m/190 ratio. The aforementioned indications from data testing involving assemblies containing actinides - that the (n,2n) products are overpredicted by 5-30% - could be used to motivate a decrease in the evaluated (n,2n) cross sections in the approximately 8-12 MeV range. However, at this stage we have not modified these cross sections since: (a) They are consistent with the cross section laboratory measurements; and (b) It is possible that the cross sections are correct and instead the simulated integral assembly neutron spectrum is too high for neutron energies above 8 MeV. The latter possibility is particularly intriguing given all three detector materials showed a bias in the same direction, and that the evaluated actinide prompt fission spectra and inelastic scattering data are probably uncertain to at least 20% above 8 MeV. We also discuss refinements needed in the transport methods to faithfully represent the evaluated data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Ethernet-based Data Acquisition System for the NIFFTE Time Projection Chamber

The goal of the NIFFTE Collaboration is to make neutron-induced fission cross section measurements to better than 1% total uncertainty, improving on the current ENDF values particularly for neutron energies belows 14 MeV. To that end, they are developing a time projection chamber (TPC) to directly measure the fission products from targets placed in a neutron beam at LANSCE.

Wood, L.↗

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, an aluminum cryostat, an aluminum target vessel shielded with {sup 6}Li-rich plastic, a hydrogen fill/vent line with a passive recirculation loop to establish and maintain the equilibrium ortho-para ratio, a hydrogen relief system coupled to a vent stack, a gas handling system, and an alarm and interlock system. Low Z, nonmagnetic materials were used for the target vessel and cryostat. Pressure and temperature sensors monitored the thermodynamic state of the target. Relative neutron transmission measurements were used to monitor the parahydrogen fraction of the target. The target was thoroughly tested and successfully operated during the first phase of the NPDGamma experiment conducted at the FP12 beam line at Los Alamos Neutron Science Center (LANSCE). An upgraded version of the target system will be used in the next stage of the experiment, which will be performed at the Fundamental Neutron Physics Beam (FnPB) line of the Spallation Neutron Source at Oak Ridge National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting image blur in proton radiography: comparisons between measurements and Monte Carlo simulations

Given the cost and lead-times involved in high-energy proton radiography, it is prudent to model proposed radiographic experiments to see if the images predicted would return useful information. We recently modified our raytracing transmission radiography modeling code HADES to perform simplified Monte Carlo simulations of the transport of protons in a proton radiography beamline. Beamline objects include the initial diffuser, vacuum magnetic fields, windows, angle-selecting collimators, and objects described as distorted 2D (planar or cylindrical) meshes or as distorted 3D hexahedral meshes. We present an overview of the algorithms used for the modeling and code timings for simulations through typical 2D and 3D meshes. We next calculate expected changes in image blur as scattering materials are placed upstream and downstream of a resolution test object (a 3 mm thick sheet of tantalum, into which 0.4 mm wide slits have been cut), and as the current supplied to the focusing magnets is varied. We compare and contrast the resulting simulations with the results of measurements obtained at the 800 MeV Los Alamos LANSCE Line-C proton radiography facility.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-high speed burst-mode imager for multi-frame radiography

A 720 x 720 pixel hybrid-CMOS imager was fabricated by Rockwell Scientific (now Teledyne Imaging Sensors). Several cameras have been in operation for 5 years, in a variety of static and dynamic experiments, at the 800MeV proton radiography (pRAD) facility at the LANSCE accelerator. The cameras can operate with a per-pulse adjustable inter-frame time of 250ns to 2s, and with an exposure/integration-time as short as 150 ns. Given the 800 ms total readout time, the imager can be externally synchronized to 0.1-to-5Hz, 50-ns wide proton beam pulses, and record 1000-frame radiographic movies of 5-to-30 minute duration. The effectiveness and dependence of the global electronic shutter on the pixelated Si photo-sensor bias voltage is discussed. The spatial resolution dependence of the full imaging system on various monolithic and structured scintillators is presented. We also present features of a new-generation 10-frame, 1024 x 1024 pixel, 50-ns exposure, 12-bit dynamic range imager, which is now in the design phase.

47 OTHER INSTRUMENTATION↗