Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LABORATORIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Evolved Gas Analysis and X-Ray Diffraction of Carbonate Samples from the 2009 Arctic Mars Analog Svalbard Expedition: Implications for Mineralogical Inferences from the Mars Science Laboratory

The 2009 Arctic Mars Analog Svalbard Expedition (AMASE) investigated several geologic settings using methodologies and techniques being developed or considered for future Mars missions, such as the Mars Science Laboratory (MSL), ExoMars, and Mars Sample Return (MSR). AMASE-related research comprises both analyses conducted during the expedition and further analyses of collected samples using laboratory facilities at a variety of institutions. The Sample Analysis at Mars (SAM) instrument suite, which will be part of the Analytical Laboratory on MSL, consists of a quadrupole mass spectrometer (QMS), a gas chromatograph (GC), and a tunable laser spectrometer (TLS). An Evolved Gas Analysis Mass Spectrometer (EGA-MS) was used during AMASE to represent part of the capabilities of SAM. The other instrument included in the MSL Analytical Laboratory is CheMin, which uses X-Ray Diffraction (XRD) and X-Ray Fluorescence (XRF) to perform quantitative mineralogical characterization of samples. Field-portable versions of CheMin were used during the AMASE 2009. Here, we discuss the preliminary interpretation of EGA and XRD analyses of selected AMASE carbonate samples and implications for mineralogical interpretations from MSL. Though CheMin will be the primary mineralogical tool on MSL, SAM EGA could be used to support XRD identifications or indicate the presence of volatile-bearing minerals which may be near or below XRD detection limits. Data collected with instruments in the field and in comparable laboratory setups (e.g., the SAM breadboard) will be discussed.

McAdam, A. C.↗

Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory

Broerman, Craig↗

Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory.

Broerman, Craig↗

Module Architecture for in Situ Space Laboratories

The paper analyzes internal outfitting architectures for space exploration laboratory modules. ISS laboratory architecture is examined as a baseline for comparison; applicable insights are derived. Laboratory functional programs are defined for seven planet-surface knowledge domains. Necessary and value-added departures from the ISS architecture standard are defined, and three sectional interior architecture options are assessed for practicality and potential performance. Contemporary guidelines for terrestrial analytical laboratory design are found to be applicable to the in-space functional program. Densepacked racks of system equipment, and high module volume packing ratios, should not be assumed as the default solution for exploration laboratories whose primary activities include un-scriptable investigations and experimentation on the system equipment itself.

planetary↗

Recent Progress in Laboratory Astrophysics and Astrochemistry Achieved with the COSmIC Facility

We describe the characteristics and the capabilities of the laboratory facility, COSmIC, that was developed at NASA Ames to generate, process and analyze interstellar, circumstellar and planetary analogs in the laboratory. COSmIC stands for "Cosmic Simulation Chamber" and is dedicated to the study of neutral and ionized molecules and nanoparticles under the low temperature and high vacuum conditions that are required to simulate various space environments such as diffuse interstellar clouds, circumstellar outflows and planetary atmospheres. COSmIC integrates a variety of state-of-the-art instruments that allow recreating simulated space conditions to generate, process and monitor cosmic analogs in the laboratory. The COSmIC experimental setup is composed of a Pulsed Discharge Nozzle (PDN) expansion, that generates a plasma in the stream of a free supersonic jet expansion, coupled to high-sensitivity, complementary in situ diagnostics: cavity ring down spectroscopy (CRDS) and laser induced fluorescence (LIF) systems for photonic detection, and Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS) for mass detection. Recent results obtained using COSmIC will be highlighted. In particular, the progress that has been achieved in the domain of the diffuse interstellar bands (DIBs) and in monitoring, in the laboratory, the formation of circumstellar dust grains and planetary atmosphere aerosols from their gas-phase molecular precursors. Plans for future laboratory experiments on interstellar and planetary molecules and grains will also be addressed, as well as the implications of the studies underway for astronomical observations and past and future space mission data analysis.

Salama, Farid↗

Laboratory Astrophysics Studies of the Evolution of Organic Matter with the COSmIC Facility.

Understanding the origin of organic matter in astrophysical environments ranging from circumstellar (CS) outflows to diffuse and dense interstellar (IS) clouds to protoplanetary disks and planetary bodies has become a central objective in astrophysics. Experimental facilities dedicated to the formation and characterization of laboratory analogs generated under conditions relevant to the targeted environments have been developed in the past recent years. Recent advances achieved in laboratory astrophysics using COSmIC’s laboratory data in synergy with observational data will be presented. These results include the use of laboratory spectra to search for IS organic molecules and ions in astronomical spectra, the formation of laboratory analogs of CS and IS dust grains and planetary atmospheres aerosols from molecular precursors.

Salama, Farid↗

The Chemical Evolution of Cosmic Dust: From Gas-Phase Precursors to Solid Grains - Laboratory Studies with the COSmIC Facility

Cosmic dust in in its gas phase and solid phase components plays an essential role in the chemical and physical evolution of the universe. Our understanding of cosmic dust properties relies on a combination of astronomical observations, astrophysical modeling and laboratory studies of realistic analogs of cosmic dust being gas-phase molecules and/or solid grains. The COSmIC facility was developed at NASA Ames to study the evolution of cosmic carbon from circumstellar outflows to interstellar clouds to planetary atmospheres in the laboratory. COSmIC stands for “Cosmic Simulation Chamber” and is dedicated to the study of neutral and ionized molecules and grain particles under the low temperature and density conditions that are required to simulate space environments. It integrates a variety of instruments that allow generating, processing, and monitoring simulated space conditions in the laboratory. It is composed of a Pulsed Discharge Nozzle (PDN) expansion that generates a plasma in a free supersonic jet expansion, coupled to high-sensitivity, complementary in situ diagnostic tools used for the detection and characterization of the species present in the expansion: Cavity Ring Down Spectroscopy (CRDS) and fluorescence spectroscopy systems for photonic detection and an orthogonal Reflectron Time-Of-Flight Mass Spectrometer (oReTOF-MS) for mass detection. Recent advances achieved using COSmIC’s laboratory data in synergy with observational data will be presented. These results include the formation of dust grains and aerosols from gas-phase molecular precursors in environments as varied as circumstellar outflows of late AGB stars and planetary atmospheres [4] and the evolution of our understanding of the diffuse interstellar bands (DIBs) with applications to the ESO Diffuse Interstellar Bands Large Exploration Survey (EDIBLES). Plans for future laboratory developments and techniques to study the evolution of cosmic carbon molecules and grains (including NIR-MIR CRDS, laser induced fluorescence (LIF) and incandescence (LII)) will also be addressed as well as their astronomical applications.

Farid Salama↗

The Influence of Self-Reported Distractions on the Psychomotor Vigilance Task (PVT) in Laboratory and Field Environments

Introduction: The Psychomotor Vigilance Task (PVT) is a measure of vigilant attention that is commonly used in laboratory environments to assess the neurobehavioral impact of sleep loss and circadian misalignment. The PVT has been increasing in popularity for use in field environments; however, the potential for distraction is higher in the field compared to the lab. It is unclear how distractions experienced by individuals taking the PVT in the real world may influence reaction time metrics. We investigated the influence of self-reported distraction on PVT outcomes across laboratory and field environments. Methods: We examined PVT data from five studies including short (n=36 participants, 3799 PVTs) and long-haul (n=75 participants, 3283 PVTs) airline personnel, control center personnel (n=5 participants, 96 PVTs), and healthy individuals who participated in a study involving at-home and laboratory assessments (n=12 participants, 486 and 310 PVTs). Individuals in all of the studies were asked to complete the five-minute NASA PVT at least three times daily. Participants were asked to indicate the number of distractions they experienced immediately after each PVT. Mean PVT reaction time (RT) and number of distractions were computed for each study and overall. Results: Participants reported more distractions in field environments compared to the lab (short-haul=1.29 +/- 1.48, long-haul=0.66 +/- 1.07, control-center=1.20 +/- 1.37, at-home=0.86 +/- 1.36, laboratory=0.46 +/- 1.07) Across all studies, we found that PVT RT slowed as self-reported distractions increased (all studies combined: 0 distractions=PVT RT 274.4ms; 1=284.6ms; 2=302.9ms; 3=321.2ms; >4=409.3ms). These findings were similar for healthy participants completing PVTs at home (0 distractions=287.1ms; 1=309.9ms; 2=328.3ms; 3=369.8ms; >4=385.1ms) but were less consistent during in-lab assessments (0 distractions=278.7ms; 1=316.2ms; 2=396.2ms; 3=370.4ms; >4=354.4ms). These findings were similar for other PVT outcomes. Conclusion: Participants reported more distractions in field environments compared to the laboratory. Our findings suggest that the number of distractions that individuals report experiencing while taking a PVT increases the reaction time registered by the device. Researchers should collect information about distractions during the PVT and should be aware that distractions may influence the recorded PVT reaction time.

behavior↗

Analysis of Darkened Fragments Resulting from Laboratory Hypervelocity Experiments

NASA’s Orbital Debris Program Office (ODPO) relies on measurements from optical, radar, and in situ measurements to facilitate the development of data-driven orbital debris environmental engineering models such as the NASA Orbital Debris Engineering Model (ORDEM). For optical measurements, the ODPO relies on ground-based optical telescopes to statistically assess objects in geosynchronous orbit and, in the future, low Earth orbit (LEO). The data collected include the detected object’s orbital parameters, time of observation, and optical magnitude. The latter parameter can be converted to a size using NASA’s optical Size Estimation Model (oSEM). It is well known that the observed magnitude of orbital debris can vary based on an object's material constituents, observational geometry, and the effects of space weathering. To assess these magnitude variations, the ODPO uses the Optical Measurement Center (OMC) at NASA Johnson Space Center to characterize a variety of materials and fragments from laboratory impact tests representative of fragments that constitute the orbital debris population. One experiment was DebriSat: a 56 kg spacecraft was built to incorporate structural elements of a modern LEO spacecraft and was subjected to a hypervelocity impact test at the U.S. Air Force’s Arnold Engineering Development Complex using test parameters that may be encountered in LEO. The DebriSat project has provided an abundance of information for assessing fragmentation debris in terms of material, color, shape, size, density, mass, and other derived parameters. Prior to the impact test, the ODPO collected spectral measurements on a subset of the materials used to construct DebriSat for a “ground-truth” of their optical properties. After the successful hypervelocity impact test, the DebriSat team observed a fine, dark dust coating all the fragments. Prior research has suggested that this came from ablated material deposited on the fragments during the impact test, causing a change in the reflective properties [1]. Given that this lower reflectivity on the DebriSat fragments will influence the laboratory-acquired magnitudes used to calculate size and inform potential updates to the oSEM, it is critical to assess if this darkening effect on the DebriSat fragments is a laboratory bias or something that could occur in on-orbit breakup events. This paper will provide a brief overview of the OMC and DebriSat experiment, focused on the optical characterization of a subset of materials using broadband photometric measurements and spectroscopic measurements. In addition, elemental analysis of various DebriSat fragments and the soft-catch foam used in the hypervelocity experiment compared with pristine foam will be examined to further evaluate the source of the dark material coating all fragments. Finally, the authors will present a twofold plan 1) for assessing potential biases in laboratory impact experiments that could affect laboratory optical characterization and 2) for mitigating biases when compared with ground-based optical telescopic measurements of the orbital debris environment.

Heather Cowardin↗

Analysis of Darkened Fragments Resulting from Laboratory Hypervelocity Experiments

NASA’s Orbital Debris Program Office (ODPO) relies on measurements from optical, radar, and in situ measurements to facilitate the development of data-driven orbital debris environmental engineering models such as the NASA Orbital Debris Engineering Model (ORDEM). For optical measurements, the ODPO relies on ground-based optical telescopes to statistically assess objects in geosynchronous orbit and, in the future, low Earth orbit (LEO). The data collected include the detected object’s orbital parameters, time of observation, and optical magnitude. The latter parameter can be converted to a size using NASA’s optical Size Estimation Model (oSEM). It is well known that the observed magnitude of orbital debris can vary based on an object's material constituents, observational geometry, and the effects of space weathering. To assess these magnitude variations, the ODPO uses the Optical Measurement Center (OMC) at NASA Johnson Space Center to characterize a variety of materials and fragments from laboratory impact tests representative of fragments that constitute the orbital debris population. One experiment was DebriSat: a 56 kg spacecraft was built to incorporate structural elements of a modern LEO spacecraft and was subjected to a hypervelocity impact test at the U.S. Air Force’s Arnold Engineering Development Complex using test parameters that may be encountered in LEO. The DebriSat project has provided an abundance of information for assessing fragmentation debris in terms of material, color, shape, size, density, mass, and other derived parameters. Prior to the impact test, the ODPO collected spectral measurements on a subset of the materials used to construct DebriSat for a “ground-truth” of their optical properties. After the successful hypervelocity impact test, the DebriSat team observed a fine, dark dust coating all the fragments. Prior research has suggested that this came from ablated material deposited on the fragments during the impact test, causing a change in the reflective properties [1]. Given that this lower reflectivity on the DebriSat fragments will influence the laboratory-acquired magnitudes used to calculate size and inform potential updates to the oSEM, it is critical to assess if this darkening effect on the DebriSat fragments is a laboratory bias or something that could occur in on-orbit breakup events. This presentation will provide a brief overview of the OMC and DebriSat experiment, focused on the optical characterization of a subset of materials using broadband photometric measurements and spectroscopic measurements. In addition, elemental analysis of various DebriSat fragments and the soft-catch foam used in the hypervelocity experiment compared with pristine foam will be examined to further evaluate the source of the dark material coating all fragments. Finally, the authors will present a twofold plan 1) for assessing potential biases in laboratory impact experiments that could affect laboratory optical characterization and 2) for mitigating biases when compared with ground-based optical telescopic measurements of the orbital debris environment.

Heather Cowardin↗

Iodine Standard Materials: Preparation and Inter-Laboratory Comparisons

The Idaho National Laboratory is preparing to enter the community of AMS practioners who analyze for 129Iodine. We expect to take delivery of a 0.5 MV compact accelerator mass spectrometry system, built by NEC, in the early summer of 2014. The primary mission for this instrument is iodine; it is designed to analyze iodine in the +3 charge state. As part of the acceptance testing for this instrument, both at NEC and on-site in our laboratory, some sort of standard or reference material is needed to verify performance. Appropriate standard materials are not readily available in the commercial marketplace. Small quantities can sometimes be acquired from other laboratories already engaged in iodine analyses. In the longer-term, meaningful quantities of standard materials are needed for routine use in analyses, and for quality control functions1. We have prepared some standard materials, starting with elemental Woodward iodine and NIST SRM 3231 [Iodine-129 Isotopic Standard (high level)] 10-6 solution. The goal was to make mixtures at the 5x10-10, 5x10-11, 5x10-12 ratio levels, along with some unmodified Woodward, in the chemical form of silver iodide. Approximately twenty grams of each of these mixtures were prepared. The elemental Woodward iodine was dissolved in chloroform, then reduced to iodide using sodium bisulfite in water. At this point the NIST spike material was added, in the form of sodium iodide. The mixed iodides were oxidized back to iodine in chloroform using hydrogen peroxide. This oxidation step was essential for isotopic equilibration of the 127 and 129 atoms. The iodine was reduced to iodide using sodium bisulfite as before. Excess sulfites and sulfates were precipitated with barium nitrate. After decanting, silver nitrate was used to precipitate the desired silver iodide. Once the silver iodide was produced, the material was kept in darkness as much as possible to minimize photo-oxidation. The various mixtures were synthesized independently of each other; there were no serial dilutions involved. Aliquots of these four materials have been submitted to five established AMS laboratories where iodine analyses are routinely performed: ETH (Zurich), CNA (Seville), PRIME (Purdue), LLNL (California), and Isotrace (Toronto.) Results from four of these laboratories have been received; in general they indicate that the desired 129/127 ratios have been achieved. We will discuss the results of this informal round-robin exercise. If the installation of the instrument in Idaho goes well, we may have some very preliminary results from the new system. An integral part of data reporting is the approach to data reduction. Accordingly, there will also be some discussion of various philosophies of data handling in regard to the use of standards to adjust data, and background subtraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Saving Water at Los Alamos National Laboratory

Los Alamos National Laboratory decreased its water usage by 26 percent in 2014, with about one-third of the reduction attributable to using reclaimed water to cool a supercomputing center. The Laboratory's goal during 2014 was to use only re-purposed water to support the mission at the Strategic Computing Complex. Using reclaimed water from the Sanitary Effluent Reclamation Facility, or SERF, substantially decreased water usage and supported the overall mission. SERF collects industrial wastewater and treats it for reuse. The reclamation facility contributed more than 27 million gallons of re-purposed water to the Laboratory's computing center, a secured supercomputing facility that supports the Laboratory’s national security mission and is one of the institution’s larger water users. In addition to the strategic water reuse program at SERF, the Laboratory reduced water use in 2014 by focusing conservation efforts on areas that use the most water, upgrading to water-conserving fixtures, and repairing leaks identified in a biennial survey.

54 ENVIRONMENTAL SCIENCES↗

INTER-LABORATORY RESULTS AND ANALYSES OF MINI-C(T) SPECIMEN TESTING OF AN IRRADIATED LINDE 80 WELD METAL

An irradiated low-upper-shelf Linde 80 weld metal has been tested by four laboratories as part of an inter-laboratory assessment of use of the miniature compact tension [mini-C(T)] test specimen for Master Curve fracture toughness evaluation following ASTM E1921. The preliminary results from each of the laboratories have been compiled and evaluated together to assess the validity and use of the mini-C(T) specimen for an irradiated reactor pressure vessel material which can exhibit ductile crack growth at low temperatures relative to cleavage initiation fracture toughness. The preliminary results from this mini-C(T) testing can also be compared to extensive specimen test results from larger C(T) specimens of the same irradiated material. Comparisons of the results from each of the laboratories and some inter-laboratory differences in the fracture testing are assessed. The evaluations indicate reasonable agreement between the mini-C(T) and larger specimen results, but the selection of test temperature and the number of test specimens needed to obtain reliable results are more difficult when testing a low-upper-shelf toughness material.

Server, W. L.↗

Case Study - Intentional Inclusion: How embedding inclusion into the fabric of Idaho National Laboratory positioned the organization for a sustainable future

Idaho National Laboratory, a Department of Energy national laboratory headquartered in Idaho Falls, Idaho, set out to embed inclusion into every aspect of its organization. The goal was to ensure the laboratory is a place where everyone feels they are valued, belong and can bring their best selves to work each day. The laboratory viewed inclusion as a journey in which a consistent, collective commitment to intentional decision-making and incremental progress ultimately achieves amazing results. INL’s intentional inclusion strategy has allowed the organization to: • Retain and build a next-generation workforce to transform the world’s energy future and secure the nation’s most critical infrastructure. • Lead inclusively through individual, team-based, and labwide actions that elevate organizational effectiveness. • Grow laboratory cultural acumen by establishing a clear connection between inclusion and mission success. This case study shares how INL brought employees along on the inclusion journey and inspired everyone to keep moving forward together.

99 GENERAL AND MISCELLANEOUS↗

The NREL Sensor Laboratory: Status and Future Directions for Hydrogen Detection

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for the national and international hydrogen community to ensure the availability and proper use of hydrogen sensors. Since then, the Sensor Laboratory has provided unbiased verification of hydrogen sensor performance for sensor developers, end-users, and regulatory agencies and has also provided active support for numerous code and standards development organizations. Although sensor performance assessment remains a core capability, the mission of the NREL Sensor Laboratory has expanded toward a more holistic approach regarding the role of hydrogen detection and its implementation strategy for both assurance of facility safety as well as for process control applications. Active monitoring for detection of unintended releases has been identified by the NFPA 2 Storage Task Group as a viable approach for improving facility safety and lowering setbacks. The current research program for the Sensor Laboratory addresses both conventional and advanced developing detection strategies in response to the emerging large-scale markets, such as those envisioned by H2@Scale. These emerging hydrogen applications may require alternative detection strategies that supplement and may ultimately supplant the use of traditional sensors for monitoring hydrogen releases. Research focus areas for the NREL Sensor Laboratory now encompasses the characterization of released hydrogen behavior to optimize detection strategies for both indoor and outdoor applications, advanced methods of hydrogen leak detection such as hydrogen wide area monitoring approaches for large scale and distributed applications, the incorporation of active monitoring as a risk reduction strategy to improve safety at hydrogen facilities, and continuing support of hydrogen safety codes and standards. In addition to assurance of safety, detection will be critical for process control applications, such as hydrogen fuel quality verification for fuel cell vehicle applications and for monitoring and controlling of hydrogen-natural gas blend composition.

codes and standards↗

Decommissioning of Active Ventilation Systems in a Nuclear R and D Facility to Prepare for Building Demolition (Whiteshell Laboratories Decommissioning Project, Canada) - 13073

Whiteshell Laboratories (WL) is a nuclear research establishment owned by the Canadian government and operated by Atomic Energy of Canada Limited (AECL) since the early 1960's. WL is currently under a decommissioning license and the mandate is to remediate the nuclear legacy liabilities in a safe and cost effective manner. The WL Project is the first major nuclear decommissioning project in Canada. A major initiative underway is to decommission and demolish the main R and D Laboratory complex. The Building 300 R and D complex was constructed to accommodate laboratories and offices which were mainly used for research and development associated with organic-cooled reactors, nuclear fuel waste management, reactor safety, advanced fuel cycles and other applications of nuclear energy. Building 300 is a three storey structure of approximately 16,000 m{sup 2}. In order to proceed with building demolition, the contaminated systems inside the building have to be characterized, removed, and the waste managed. There is a significant focus on volume reduction of radioactive waste for the WL project. The active ventilation system is one of the significant contaminated systems in Building 300 that requires decommissioning and removal. The active ventilation system was designed to manage hazardous fumes and radioactivity from ventilation devices (e.g., fume hoods, snorkels and glove boxes) and to prevent the escape of airborne hazardous material outside of the laboratory boundary in the event of an upset condition. The system includes over 200 ventilation devices and 32 active exhaust fan units and high efficiency particulate air (HEPA) filters. The strategy to remove the ventilation system was to work from the laboratory end back to the fan/filter system. Each ventilation duct was radiologically characterized. Fogging was used to minimize loose contamination. Sections of the duct were removed by various cutting methods and bagged for temporary storage prior to disposition. Maintenance of building heating, ventilation and air conditioning (HVAC) balancing was critical to ensure proper airflow and worker safety. Approximately 103 m{sup 3} of equipment and materials were recovered or generated by the project. Low level waste accounted for approximately 37.4 m{sup 3}. Where possible, ducting was free released for metal recycling. Contaminated ducts were compacted into B-1000 containers and stored in a Shielded Modular Above-Ground Storage Facility (SMAGS) on the WL site awaiting final disposition. The project is divided into three significant phases, with Phases 1 and 2 completed. Lessons learned during the execution of Phases 1 and 2 have been incorporated into the current ventilation removal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Setting an optimal procedure for transferring intermediate radioactive effluents: contribution of laboratory experiments - 15234

The INB35 nuclear facility at the CEA Saclay center is in charge of collecting and treating radioactive effluents generated from site's research activities. The first step of the process consists of an evaporation. The concentrate is an IL radioactive suspension with high salt concentration and suspended matter content. Until the 1990's, the resulting effluents were bitumen coated and since 2012 they have been cemented. During the 1990's, concentrates were stored in 7 tanks, named MA50X with X from 1 to 7. With today's changes to safety regulations, the effluents must now be transferred before tank dismantling. According to the site records, the compositions of the liquid wastes MA501, MA502, MA503, MA504, MA506 and MA507 are similar. From 2013 to 2014, effluents contained in MA502, MA503, MA504 tanks have been transferred. Several difficulties have been encountered: - The tanks were historically different, especially manhole tank access - Since the 1990's, effluent composition has changed due to water evaporation. The salt concentration has increased and insoluble elements have formed a deposit in the bottom of the tanks resulting in high composition heterogeneity - In some tanks, a wall breeze-blade exists dividing the tank into two zones, which complicates the interventions. Major challenges have been met and will be described in the presentation. - To obtain an effluent which is as homogeneous as possible, the duration of mixing has been optimized. - To pump the liquid, it has been necessary to treat the effluent with nitric acid. This step has been optimized thanks to experiments in laboratory and hydrodynamic modelling. - A mobile workshop has been designed in order to perform the effluent transfer. It is set up directly above the tanks and can be moved from one tank to another on rails. Laboratory experiments have been carried out to characterize the suspension and sludge in order to understand its chemical behavior. - The treatment of the effluent has been studied in the laboratory and is now mastered. - The analytical strategy has been optimized. The close collaboration between the analytical laboratory and the dismantling project was a real advantage. Thanks to this, the duration of the last transfer on MA 504 was reduced by half, compared to the first operations. Transfer operations will be described and the differences and similarities between laboratory and in-situ observations will be pointed out. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Closing the Accuracy Gap in Tandem Photovoltaic Testing: An Accessible and Efficient Spectral Tuning Method Using LED-Based Simulators for Research Laboratories and Industry

Accurate performance calibration of multijunction (MJ) solar cells is critical for advancing this technology toward large-scale terrestrial application, yet existing testing methods developed by photovoltaics calibration laboratories remain prohibitively complex and resource intensive for most research laboratories. Current approaches rely on expensive multisource simulators and/or intricate spectral tuning algorithms, limiting accessibility and hindering standardized comparisons of emerging MJ technologies such as perovskite-based tandems. This paper introduces a streamlined spectral irradiance adjustment method for light-emitting diode (LED)-based solar simulators, which are increasingly adopted in the photovoltaics community due to their versatility and cost-effectiveness. The method we present bins LED channels into groups based on the number of junctions of the MJ photovoltaic device under test (DUT) and their corresponding band gaps and incorporates an automated tuning algorithm that eliminates the need to adjust each channel’s irradiance individually. This tuning algorithm requires the relative spectral responsivities of both the DUT and a broadband reference cell, as well as a calibrated spectroradiometer. Measurement validation across various MJ devices, including III-V and perovskite/silicon tandems, demonstrates excellent agreement within 1% with well-established xenon-tungsten multisource simulators and associated tuning algorithms. By enabling precise spectral tuning with readily available equipment and a simple tuning algorithm, our approach bridges the measurement accuracy gap between research laboratories and accredited testing facilities, fostering more reliable device comparisons and accelerating the translation of MJ technologies into real-world energy systems.

14 SOLAR ENERGY↗