Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Realization of a high luminosity muon beam at the Jefferson Lab

The proton is the major component of the visible matter of our universe, so being able to determine its fundamental properties, such as its charge radius, is of vital importance. In recent years, several experiments have been performed for the accurate measurement of the proton radius with different experimental techniques. The main and most common are based on two different techniques: ep scattering and Lamb shift spectroscopy of regular hydrogen atoms. The latter can also be performed on muonic hydrogen atoms with a significant improvement in accuracy. Recent measurements that use this method have highlighted a discrepancy between the results obtained with the diffusion of electrons and those obtained with the spectroscopic technique leading to the so-called ?proton radius puzzle?. The explanation of why this difference between the measured values exists is still a matter of discussion. The last attempt to address the puzzle was the PRad Experiment. It was performed with a unique experimental setup that gave the scientists an excellent control on the systematic errors that are usually present in electron-proton scattering experiments. This has significantly increased the precision of the measurement, bringing it in the same area as the spectroscopic ones done on muonic hydrogen atoms, which are considered the most precise. However, to solve the puzzle once and for all, even more precise electron scattering measurements are needed. Alternatively, new methods can be used, such as eg. muon-proton scattering at low transferred momenta in order to lower the systematic errors that comes with the measurement. This thesis tries to address this problem by studying the set up of an intense muon beam at the Jefferson Laboratory (JLab) that can be used to carry out a high-precision m ? p scattering experiment. Using Montecarlo simulations I studied the muon production resulting from the interaction of the primary electron beam with the beam-dump at JLab Hall-A. The simulations were performed using the FLUKA package via the FLAIR graphical interface. In this study, I modified an existing geometry (built for the ?Beam Dump eXperiment?) and performed several studies in order to optimize the muon beam parameters. In order to estimate the beam intensity, I studied the muon generation and transportation through the concrete bunker surrounding the Hall-A beam-dump. Detailed studies on muon attenuation and dispersion at different depth allowed me to track the beam profile in space and momentum as a function of the distance from the beam-dump. Last, but not least, I studied a possible tagging system for the muon beam. The tagging system will allow us to know with good precision (O(1=1000)) the energy of each muon of the beam. Based on the results obtained, I created an event generator that incorporates the detailed description of the muon beam (energy, position, emittance) useful to define and optimize the experimental setup for a future measurement of the proton radius at the JLab.

Fulci, Antonino↗

Measuring the weak charge of the proton at Jefferson Lab: A search for physics beyond the standard model

The JLab Q weak Collaboration is designing and constructing an experiment to measure the protonâ s weak charge, Q W p , by measuring the parity violating asymmetry in elastic electron-proton scattering at very low momentum transfer. The standard model predicts Q W p = 1 - 4 sin2 theta w from the running of the weak mixing angle sin2 theta w , corresponding to a 10sigma effect in the experiment. The experiment will determine Q W p with 4% combined statistical and systematic uncertainties, which leads to 0.3% uncertainty in sin2 theta w . Installation of the experiment will begin in September 2009.

43 PARTICLE ACCELERATORS↗

The Aerogel Cerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab

Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n =1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching 10 -2 proton and 10 -3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ~12 for n =1.030, ~8 for n =1.020, ~10 for n =1.015, and ~5.5 for n =1.011. Here the design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab

A new Large-Acceptance Forward Angle Spectrometer (Super BigBite) is under development at JLab/Hall A to optimally exploit the exciting opportunities o?ered by the 12 GeV upgrade of the electron beam. The tracker of this new apparatus is based on the Gas Electron Multiplier (GEM) technology, which has been chosen to optimize cost/performance, position resolution and to meet the high hit rate (>1 MHz/cm2). The first GEM detector modules, designed and built by the INFN Collaboration JLAB12, were tested at the DESY test beam facility in Hamburg, by using an electron beam with energy ranging from 2.0 to 6.0 GeV. In particular, two 40x50 cm2 and one 10x10 cm2 GEM chambers were equipped with a new implementation of the APV25 readout chip. Measurements were performed at di?erent impact points and angles between the electron beam and the plane of the GEM chambers, with one large chamber in a solenoid magnetic field up to 500 Gauss. In this report we present the technical characteristics of the detector and comment on the presently achieved performance.

Mammoliti, F.↗

The RICH detector for CLAS12 at Jefferson Lab

The CLAS12 spectrometer at JLab will offer unique possibilities to study the 3D nucleon structure in terms of TMDs and GPDs in the poorly explored valence region, and to perform high precision hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification capability in the momentum range 3-8 GeV/c. The detector, based on a novel hybrid imaging design, foresees an aerogel radiator and an array of multi-anode photomultipliers. The detector concept and preliminary results of test-beams on a prototype are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryostat design and analysis of the superconducting magnets for Jefferson Lab's 11-GEV/C super high momentum spectrometer

This paper describes the mechanical design and analysis of the cryostats for the two cos(2theta) quadrupoles and the cos(theta) dipole. All the magnets are currently being bid for commercial fabrication. The results of finite element analysis for the magnet cryostat helium vessels and outer vacuum chambers which investigate the mechanical integrity under maximum allowable internal working pressure, maximum allowable external working pressure, and cryogenic temperature are discussed. The allowable stress criterion is determined based on the allowable stress philosophy of the ASME codes. The computed cryogenic heat load of the magnets is compared with the allowable cryogenic consumption budget. The presented cool-down time of the magnets was studied under the conditions of a limited supply rate and a controlled temperature differential of 50 K in the magnets.

43 PARTICLE ACCELERATORS↗

Design and analysis of the warm-to-cold suspension links for Jefferson Lab's 11-GEV/C super high momentum spectrometer

This paper describes design and analysis performed for the warm-to-cold suspension links of the warm iron yoke superconducting quadrupole magnets, and superconducting dipole magnet. The results of investigation of titanium Ti-6Al-4V and Nitronic 50 stainless steel for the suspension links to support the cold mass, preloads, forces due to cryogenic temperature, and imbalanced magnetic forces from misalignments are presented. Allowable stresses at normal-case scenarios and worst-case scenarios, space constraints, and heat leak considerations are discussed. Principles of the ASME Pressure Vessel Code were used to determine allowable stresses. Optimal angles of the suspension links were obtained by calculation and finite element methods. The stress levels of suspension links at multiple scenarios are presented, discussed, and compared with the allowable stresses.

36 MATERIALS SCIENCE↗

Final results of the GEp(III) experiment at Jefferson Lab

The set of proton elastic form factor ratio data was extended to Q{sup 2} = 8.5 GeV{sup 2} with a recent experiment at JLab, GEp(III); the nucleon form factor data base is discussed and several conclusions presented. These data are the result of measurements of the polarization of the recoil proton; they have been known to differ significantly from Rosenbluth separation of cross section data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nb 3 Sn multicell cavity coating system at Jefferson Lab

Superconducting radio frequency niobium cavities are the building blocks of modern accelerators for scientific applications. Lower surface resistance, higher fields, and high operating temperatures advance the reach of the future accelerators for scientific discovery as well as potentially enabling cost-effective industrial solutions. We describe the design and performance of an Nb 3 Sn coating system that converts the inner surface of niobium cavities to an Nb 3 Sn film. The niobium surface, heated by radiation from the niobium retort, is exposed to Sn and SnCl 2 vapor during the heat cycle, which results in about 2 μm Nb 3 Sn film on the niobium surface. Film composition and structure as well as radio frequency properties with 1-cell R&D cavities and 5-cell practical accelerator cavities are presented.

47 OTHER INSTRUMENTATION↗

The N* physics program at Jefferson Lab

Abstract Recent measurements of nucleon resonance transition form factors with CLAS at Je erson Lab are dis- cussed. The new data con rm the assertion of the symmetric constituent quark model of the Roper as the rst radial excitation of the nucleon. The data on high Q2 n{pi+} production better constrain the branching ratios {Beta}N_{pi} and {Beta} N_{eta}. For the first time, the longitudinal transition amplitude to the S11(1535) was extracted from the n{pi+} data. Also, new results on the transition amplitudes for the D13(1520) resonance are presented showing a rapid transition from helicity 3/2 dominance seen at the real photon point to helicty 1/2 dominance at higher Q2. I also discuss the status of the search for new excited nucleon states.

Burkert, Volker↗

Quasi elastic cross sections for the Bi-209(e, e-prime p) Pb-208 reaction: Jefferson Lab experiment E06007

Quasi elastic cross sections were measured for the first time for both negative and positive missing momenta for the {sup 209}Bi(e,e'p){sup 208}Pb reaction leading to the ground state and hole states of (208)Pb. Experimental cross sections obtained between -0.3 GeV/c to 0.3 GeV/c agree with theoretical calculations using RDWIA techniques both in shape and magnitude for the ground state. The data for the ground state production of {sup 208}Pb are consistent with a theoretical model assuming a single proton(1.06 +- 0.10) in the 1h9/2 orbit in {sup 209}Bi.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studies of GPDs at Jefferson Lab: results and future experiments

Here, the Generalized Parton Distributions (GPDs) have emerged as a universal tool to describe hadrons in terms of their elementary constituents, the quarks and the gluons. Deeply Virtual Compton Scattering (DVCS) on a proton or neutron (N), eN → e'N'γ, is one of the simplest processes that can be described in terms of GPDs. The amplitudes of DVCS and Bethe-Heitler, process where a photon is emitted by the incident or scattered electron, can be accessed via cross section measurements or exploiting their interference which give rise to spin asymmetries. Spin asymmetries, cross sections and cross-section differences can be connected to different combinations of the four leading order GPDs (H, E, $\tilde{H} $, $\tilde{E} $) for the two quark flavors depending on the observable and the type of target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗