Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter-based resources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photovoltaic inverter-based quantification of snow conditions and power loss

Snow is a significant challenge for photovoltaic (PV) systems at northern latitudes, where the pace of deployment is rapid but snow-related power losses can exceed 30% of annual production. Accurate snow-related power loss estimation methods for utility-scale sites can support snow mitigation strategies, inform resource planning and validate predictive snow-loss models. This study builds on our previous work on inverter-based detection of snow, and its implications for utility-scale power production, by validating the accuracy of our snow-loss method across different PV sites and system designs and highlighting its value in bringing greater visibility to PV plant operations in winter. Our estimation method is both novel and scalable, requiring only standard monitoring data to correlate snow-related losses with meteorological data. As demonstrated here, our validation method involved three main steps: 1) estimation of performance losses for multiple systems by comparing measured inverter data to modeled data; 2) application of a detection framework to identify which performance losses are snow-related; and 3) comparison of snow-related losses among three utility-scale sites differing in tilt angle. Results show that utility-scale systems at higher tilt angles consistently shed snow more quickly/completely than their lower-tilt counterparts. Further, monthly and seasonal snow losses are inversely and non-linearly correlated with tilt angle when normalized for cumulative snowfall. These results are consistent with the findings of previous studies and support the broad applicability of this method to fixed-tilt utility-scale PV systems around the world that routinely experience snow-related performance losses.

Cooper, Emma C. (ORCID:0000000190554098)↗

Frequency Support From Electric Vehicles for Advancing Renewable Energy Integration

The integration of renewable energy resources (RERs) in the modern power grid is increasing rapidly because of aggressive decarbonization goals, lower costs, and increased government investment. However, higher penetrations of inverter-based generation can lead to frequency stability issues because of reduced system inertia. This paper develops a framework for quantifying the contribution of electric vehicles (EVs) toward providing frequency support to the grid and thus increasing the penetration limit of renewable energy resources (RERs). EVs are considered to provide both inertial response and primary frequency response support to the grid. A stochastic approach incorporating the uncertainties associated with the behavior of EVs is developed to derive the discharge limit of EV aggregators. A multi-machine system frequency response (MM-SFR) model is developed, which incorporates the dynamic virtual inertia and droop coefficients of EV aggregators derived from the EV control modules. Frequency security constraints are developed from this MM-SFR model, which, along with the converter voltage security and low voltage ride-through constraints, are integrated within a nonlinear optimization framework to determine the RER integration limit. Here, the efficacy of the proposed approach is validated using the RTS-GMLC test system.

25 ENERGY STORAGE↗

Convolutional Neural Network-Based Protection-Zone Classification of Faults in Distribution Feeders with Photovoltaics.

Fault detection and isolation is critical for reliable operation of distribution systems. The ride-through requirements for the distributed energy resources (DER), mandated by the IEEE 1547-2018 standard, makes it challenging to use undervoltage (UV) conditions for fault detection. In addition, with low fault current contribution from these inverter-based DERs, the time-overcurrent relays are also less effective. Thus motivated, this paper presents a learning-based approach for fault detection and localization. A convolutional neural network (CNN)-based model is proposed which uses local voltage and current waveforms from DER locations and feeder substations, for training a zonal classifier. The classifier can be adopted into any relay-like device for discriminating between faults originating from different protection zones. The performance of the proposed approach was tested on publicly available test feeders with distributed photovoltaics (PVs).

Fault localization, convolutional neural networks,↗

Customized open source renewable energy models validated through PHIL lab experiments

Energy models for power systems require ongoing updates to reflect advancements in equipment technology and the increasing complexity of power electronic devices. This study utilizes a Power Hardware-in-the-Loop (PHIL) experimental setup to validate custom photovoltaic (PV) inverter models, aiming to enhance and expedite the development of advanced renewable energy models. The research compares the performance of a physical inverter with generic Renewable Energy Source (RES) models recommended by the Western Electricity Coordinating Council (WECC). As inverter-based renewable energy sources become more prevalent in modern electrical grids, it is crucial that dynamic models accurately represent their real-world behavior. Accurate models improve our understanding of these energy resources and their interactions with the grid. The proposed model enhancements are designed to better reflect real inverter performance, based on insights from PHIL experiments. These models are developed using the open source Modelica language and the OpenIPSL Modelica Library, allowing integration across various simulation tools without re-implementation. The paper concludes with a thorough assessment, comparing the enhanced models with PHIL experiments on a real PV inverter in a controlled laboratory setting. As a result, the study provides the enhanced WECC RES models and validation data as open source resources, facilitating further research and development.

Modelica↗

Design and Operation of Energy Systems with Large Amounts of Variable Generation: IEA Wind TCP Task 25 (Final Summary Report)

This report summarizes findings on wind integration from the 17 countries or sponsors participating in the International Energy Agency Wind Technology Collaboration Program (IEA Wind TCP) Task 25 from 2006-2020. Both real experience and studies are reported. Many wind integration studies incorporate solar energy, and most of the results discussed here are valid for other variable renewables in addition to wind. The national case studies address several impacts of wind power on electric power systems. In this report, they are grouped under long-term planning issues and short-term operational impacts. Long-term planning issues include grid planning and capacity adequacy. Short-term operational impacts include reliability, stability, reserves, and maximizing the value of wind in operational timescales (balancing related issues). The first section presents the variability and uncertainty of power system-wide wind power, and the last section presents recent studies toward 100% shares of renewables. The appendix provides a summary of ongoing research in the national projects contributing to Task 25 for 2021-2024. The design and operation of power and energy systems is an evolving field. As ambitious targets toward net-zero carbon energy systems are announced globally, many scenarios are being made regarding how to reach these future decarbonized energy systems, most of them involving large amounts of variable renewables, mainly wind and solar energy. The secure operation of power systems is increasingly challenging, and the impacts of variable renewables, new electrification loads together with increased distribution system resources will lead to somewhat different challenges for different systems. Tools and methods to study future power and energy systems also need to evolve, and both short-term operational aspects (such as power system stability) and long-term aspects (such as resource adequacy) will probably see new paradigms of operation and design. The experience of operating and planning systems with large amounts of variable generation is accumulating, and research to tackle the challenges of inverter-based, nonsynchronous generation is on the way. Energy transition and digitalization also bring new flexibility opportunities, both short and long term.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission-distribution long-term volt-var planning considering reactive power support capability of distributed PV

High penetration of grid-edge, inverter-based photovoltaic (PV) can cause significant voltage fluctuations not only at the distribution but also at the sub-transmission levels due to PV output intermittency. Traditional reactive power planning approaches do not consider intermittency, nor the possibility of coordinating the control of existing and future volt-ampere reactive resources. This paper proposes a reactive power planning tool for sub-transmission systems to mitigate voltage violations and fluctuations caused by high PV penetration and intermittency with a minimum investment cost. The planning tool coordinates with an optimization-based volt-var operational tool for: a) modeling the coordination of all existing var assets in both sub-transmission and distribution systems to reduce the need of new equipment, and b)selecting a set of scenarios with voltage violations, derived from PV intermittency c) testing the final investment decision. The tool obtains an investment need for each intermittency scenario with a proposed optimal power-flow framework with efficient techniques to handle a high number of discrete variables. Two options are provided for final planning decision: i) a conservative direct combination of investment need solutions and ii) a machine learning-based selection of representative investment needs at most time steps. The final investment decision options are verified using a realistic large-scale sub-transmission system and 5-minute PV and load data. The results show a significant voltage performance improvement with a lower investment cost for additional var equipment compared to conventional approaches.

14 SOLAR ENERGY↗

Assessment of Envelope- and Machine Learning-Based Electrical Fault Type Detection Algorithms for Electrical Distribution Grids

This study introduces envelope- and machine learning (ML)-based electrical fault type detection algorithms for electrical distribution grids, advancing beyond traditional logic-based methods. The proposed detection model involves three stages: anomaly area detection, ML-based fault presence detection, and ML-based fault type detection. Initially, an envelope-based detector identifying the anomaly region was improved to handle noisier power grid signals from meters. The second stage acts as a switch, detecting the presence of a fault among four classes: normal, motor, switching, and fault. Finally, if a fault is detected, the third stage identifies specific fault types. This study explored various feature extraction methods and evaluated different ML algorithms to maximize prediction accuracy. The performance of the proposed algorithms is tested in an emulated software–hardware electrical grid testbed using different sample rate meters/relays, such as SEL735, SEL421, SEL734, SEL700GT, and SEL351S near and far from an inverter-based photovoltaic array farm. The performance outcomes demonstrate the proposed model’s robustness and accuracy under realistic conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Forming PV Inverter: Technology Development and Microgrid Applications

Presently, excluding residential backup power applications, grid-forming (GFM) inverters are commercially available for battery energy storage system (BESS) and some PV plus battery systems but not yet for stand-alone PV. This tech update investigates the control design for GFM PV inverter, especially the control required to provide active power reserve and to stabilize the dc link voltage. Subsequently, the use cases of GFM PV plants in utility-level microgrids are discussed considering fully inverter-based microgrids (i.e., with PV and BESS) as well as mixed-source microgrids (i.e., with PV and diesel generator). Scenarios where active power up-reserve from GFM PV plants is beneficial are illustrated. Moreover, requirements and specifications for GFM PV plant, especially for its active power reserve function are developed. In addition, stability of an example utility-level microgrid with two GFM PV plants and a diesel generator is analyzed to shed light on the potential unstable interaction between multiple GFM resources and the countermeasures. This research aims to advance GFM PV technology to offer more flexibility in microgrid design. With GFM PV available, depending on the level of reliability required, cost-benefit analysis, etc., the GFM BESS or diesel generator may be sized smaller while leveraging the full potential of PV generation inside the microgrid.

14 SOLAR ENERGY↗

Visual Tool for Assessing Stability of DER Configurations on Three-Phase Radial Networks

Here, we present a method and tool for evaluating the placement of Distributed Energy Resources (DER) on distribution circuits in order to control voltages and power flows. Our previous work described Phasor-Based Control (PBC), a novel control framework where DERs inject real and reactive power to track voltage magnitude and phase angle targets. Here, we employ linearized power flow equations and integral controllers to develop a linear state space model for PBC acting on a three-phase unbalanced network. We use this model to evaluate whether a given inverter-based DER configuration admits a stable set of controller gains, which cannot be done by analyzing controllability nor by using the Lyapunov equation. Instead, we sample over a parameter space to identify a stable set of controller gains. Our stability analysis requires only a line impedance model and does not entail simulating the system or solving an optimization problem. We incorporate this assessment into a publicly available visualization tool and demonstrate three processes for evaluating many control configurations on the IEEE 123-node test feeder (123NF).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Supportive Loads - A New Approach to Increasing Renewable Energy in Power Systems

This paper demonstrates the potential of inverter-based loads to support grid reliability during power system transients thereby enabling reliable integration of renewable energy in power systems. Such loads are referred to in this paper as grid-supportive loads (GSLs). A new GSL model is developed that simulates the transient response capabilities that can be programmed in electronic loads. The model’s design enables it to be easily integrated in widely used commercial power system transient analysis software. Theoretical expressions are derived that explain the workings of the GSL model. The performance, numerical stability, and impact of the GSL model is validated on 9-bus and 2000-bus synthetic power system models using generator tripping and bus fault disturbances. Results on the 2000 bus system show that in the absence of frequency support from wind/solar generation resources, just 20% of loads with grid-supportive capabilities can improve frequency response by up to 2000 MW/0.1 Hz and reduce deviation in frequency at nadir by up to 60% compared to the situation when GSLs are absent. Power system reliability also improves under fault events. Here, it is further shown that GSLs can aid in integrating more renewable generation without degrading the overall transient response of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighbouring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchains↗

Impact of system parameters and geospatial variables on the reliability of residential systems with PV and energy storage

A reliable power supply is the foundation of modern society, enabling technologies used to function within a society. Residential systems are places where the end users directly consume power, enabling technologies to sustain life. With the emergence of behind-the-meter resources, the end-users have some control over power supply reliability. The intermittency and variability of these resources impact residential system reliability. In this work, we study the reliability performance of a grid-supplemented residential system with behind-the-meter Distributed Energy Resources(DER) subject to various system parameters and geospatial variables. We propose a multistate reliability model for the behind-the-meter microinverter-based Photo Voltaic (PV) system and integrated inverter-based energy storage (ES) system. A sequential Monte Carlo method is then presented to evaluate the reliability indices for the residential system with behind-the-meter DERs as the main supply and the grid as the backup. The sequential Monte Carlo method is used to analyze the reliability performance of the residential model at the top 100 populous counties of the United States, where actual load and solar irradiance data at the counties is used. In the analysis, the sensitivity of indices to system parameters such as DER size and the sensitivity of the indices to climate zone and gross horizontal irradiation (GHI), which affects the load conditions and the PV output of the residential system, is performed. The analysis results show that the system parameters and the geospatial variables significantly impact the residential system’s reliability. The insights from this analysis will be of immense value to the distribution system planners to provide zone-specific guidelines for DER system sizing and toward the evolution of utility business models. Finally, the methodology developed can be used to extend the analysis to other locations.

14 SOLAR ENERGY↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

Unifying Energy-Management Problems for Inverter-Based Power Networks

This paper outlines a suite of energy-management problems for inverter-based power networks from the vantage point of optimal control and (non)linear optimization. The problems are categorized based on timescales dictated by the network dynamics, and organized methodologically based on the problem complexity. A growing body of literature has addressed problems in this domain, albeit, with poorly motivated assumptions and behavioral models that obscure precise device behavior. With a combination of circuit- and control-theoretic lenses, we establish appropriate dynamic models for the networked resources, illustrate how common engineering assumptions arise, uncover how problems are linked, and postulate open challenges.

(non)linear optimization↗

Adding power of artificial intelligence to situational awareness of large interconnections dominated by inverter‐based resources

Abstract Large‐scale power systems exhibit more complex dynamics due to the increasing integration of inverter‐based resources (IBRs). Therefore, there is an urgent need to enhance the situational awareness capability for better monitoring and control of power grids dominated by IBRs. As a pioneering Wide‐Area Measurement System, FNET/GridEye has developed and implemented various advanced applications based on the collected synchrophasor measurements to enhance the situational awareness capability of large‐scale power grids. This study provides an overview of the latest progress of FNET/GridEye. The sensors, communication, and data servers are upgraded to handle ultra‐high density synchrophasor and point‐on‐wave data to monitor system dynamics with more details. More importantly, several artificial intelligence (AI)‐based advanced applications are introduced, including AI‐based inertia estimation, AI‐based disturbance size and location estimation, AI‐based system stability assessment, and AI‐based data authentication.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GMLC Survey of Distributed Energy Resource Interconnection and Interoperability Standards

This document reports on the Grid Modernization Laboratory Consortium effort to identify gaps in standards for the interconnection and interoperability of distributed energy resources (DERs). The project extended a 3-year period from 2017 to 2019. Under the work plan, the team identified standards and test procedures related to interconnection and interoperability, grouped under the broad headings of their primary applicable technology domain: automotive, responsive loads, photovoltaic inverters, inverter-based energy storage, machine-based DERs, and microgrids. The team then conducted a gap analysis by comparing the current standards to the expected future requirements needed for specific grid services. Overall, gaps could be any activity needed to harmonize requirements among standards development organizations, minimize conflicting requirements among technology domains, or streamline conformance test procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm: Preprint

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighboring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchain↗