Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Integrated Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Integral reactor system and method for fuel cells

A reactor system is integrated internally within an anode-side cavity of a fuel cell. The reactor system is configured to convert hydrocarbons to smaller species while mitigating the lower production of solid carbon. The reactor system may incorporate one or more of a pre-reforming section, an anode exhaust gas recirculation device, and a reforming section.

25 ENERGY STORAGE↗

Integral reactor system and method for fuel cells

A reactor system is integrated internally within an anode-side cavity of a fuel cell. The reactor system is configured to convert higher hydrocarbons to smaller species while mitigating the lower production of solid carbon. The reactor system may incorporate one or more of a pre-reforming section, an anode exhaust gas recirculation device, and a reforming section.

30 DIRECT ENERGY CONVERSION↗

An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings

Integrated performance simulation of buildings and heating, ventilation and air-conditioning (HVAC) systems can help reducing energy consumption and increasing level of occupant comfort. However, no singe building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to accommodate the ever-increasing complexity and rapid innovations in building and system technologies. One way to alleviate this problem is to use co-simulation. The co-simulation approach represents a particular case of simulation scenario where at least two simulators solve coupled differential-algebraic systems of equations and exchange data that couples these equations during the time integration. This paper elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in a co-simulation prototype. The prototype is verified and validated against the results obtained from the traditional simulation approach. It is further used in a case study for the proof-of-concept, to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling frequency. The paper concludes by defining requirements and recommendations for generic cosimulation implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beyond Price Taker: Optimizing Integrated Energy Systems Considering Market/Grid Interactions

Integrated Energy Systems (IES) combine two or more processes to increase the efficiency, flexibility of operation, and the overall reliability. However, analyzing IESs in volatile electricity markets is challenging, since the volatility in electricity prices makes the conventional levelized cost-type analysis less realistic. This work presents two approaches to address the challenge: price-taker and a surrogates-based approach for incorporating market interactions. The price-taker approach formulates a multiperiod optimization problem that takes the time-varying electricity prices into account, and solves the optimization problem to determine the optimal operational schedule that maximizes the chosen economic metric. This approach is successfully applied to investigate the performance of flexible power and hydrogen co-production systems. The market surrogates approach trains a machine learning model to predict the market behavior as a function of the characteristics of the IES. The trained surrogate model is used to optimize the design and operation of the given IES in an electricity market. This approach is demonstrated on a case study involving a nuclear power plant retrofitted with a low-temperature electrolysis unit to co-produce power and hydrogen.

beyond price taker↗

Improving the Productivity and Performance of Large-Scale Integrated Algal Systems for Wastewater Treatment and Biofuel Production

The goal of this project was to develop and demonstrate an integrated system for algal biofuel production system and wastewater treatment that can produce low-cost drop-in biofuels. Experimental data and techno-economic analysis showed the ability to produce drop-in biofuels from wastewater derived algal biomass at a cost of $3.32 and identified methods to further reduce costs. In particular, when accounting for wastewater treatment cost savings relative to conventional processes, the proposed integrated system can support a negative minimum fuel selling price. This means the normal costs of wastewater treatment are sufficient to cover all the costs of biofuel production with the integrated system.

09 BIOMASS FUELS↗

Unified probabilistic energy flow analysis for electricity–gas coupled systems with integrated demand response

Under a multi-energy environment, the conventional demand response programmes in smart-grid will be evolving to the concept of integrated demand response (IDR). In order to examine such an effect, this study presents a new methodological framework to conduct the probabilistic energy flow (PEF) analysis of integrated energy systems, while considering the potential effects of IDR. For this aim, a new price-elasticity-based IDR model is developed. As distinct from existing works, this study explicitly focuses on the stochastic characteristics of IDR programme and a novel Z-number-based technique is introduced to handle the relevant uncertainties that involved. The proposed Z-number model can not only capture the inherent randomness in demand-side performance but also account for the potential impact of information availability/reliability on the representation of IDR. Since the presence of Z-numbers makes the authors model include different types of uncertain representations, the fuzzy expectation technique and centroid method are jointly used to make them manageable under the same framework. A comprehensive algorithm based on the cumulant method and an optimisation scheme is employed to solve this PEF problem with consideration of IDR. The proposed framework is illustrated through numerical studies and simulation results confirm its effectiveness in actual implementations.

Zeng, Bo↗

Transient Data Library of Solar Grid Integrated Distributed System

This submission contains an open-source library of transient events in distributed system with high solar PV. The library includes the collected data, related documents and scripts for loading the data. The data library is built for transient event detection and machine learning based analysis algorithm development. The data was collected via both field test and software simulation. The units for the data are included in the data file headers for each data series. A text editor or spreadsheet software, such as Excel, and Matlab is required to view the data.

algorithms↗

Expanding NREL's Advanced Research on Integrated Energy Systems (ARIES) Capabilities

NREL's Integrated Energy Pathways vision represents a transformed, future integrated energy system that is more affordable, clean, secure, and resilient than today. Key to this vision is the unique Advanced Research on Integrated Energy Systems (ARIES) research platform. With a focus on advancing modern grid infrastructure, making investments in energy efficiency building technology research, and innovating battery storage and much more, the unique ARIES research platform can be used to accelerate the integration of new technologies into a modern grid.

advanced research↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated control system and method

An integrated control system for use with an engine connected to a generator providing electrical power to a switchgear is disclosed. The engine receives gas produced by a gasifier. The control system includes an electronic controller associated with the gasifier, engine, generator, and switchgear. A gas flow sensor monitors a gas flow from the gasifier to the engine through an engine gas control valve and provides a gas flow signal to the electronic controller. A gas oversupply sensor monitors a gas oversupply from the gasifier and provides an oversupply signal indicative of gas not provided to the engine. A power output sensor monitors a power output of the switchgear and provide a power output signal. The electronic controller changes gas production of the gasifier and the power output rating of the switchgear based on the gas flow signal, the oversupply signal, and the power output signal.

42 ENGINEERING↗

Productivity and cost of energy chipping with non-integrated harvesting systems in the Coastal Plain of the US south

Research from the 1980s–2010s suggested that integrated harvesting systems that harvest conventional products (e.g., sawtimber, pulpwood) and energy chips simultaneously were the most effective solution to produce energy chips in the US South. Alternatives, such as biomass-only systems, have important advantages in forest stands with low volumes of merchantable timber. The goal of this study was to estimate the productivity and cost of producing energy chips using non-integrated systems. Innovative chipping contractors using non-integrated systems were identified through contacts with procurement foresters responsible for purchasing energy chips. Elemental time-and-motion studies were conducted to estimate harvesting productivity on five operations, including one clearcut harvest and four first thinnings in overstocked stands. The hourly cost of equipment was estimated using the machine rate method. Cost per tonne was estimated by combining hourly productivity and hourly costs in a modified version of the Auburn Harvesting Analyzer. System productivity averaged 37 tonnes per scheduled machine hour (smh) and cut-and-haul costs averaged $33.86 t −1 (USD), which was comparable to previous estimates from integrated systems. In conclusion, this study suggests there are viable alternatives to integrated harvesting systems to produce energy chips, especially in stands with low volumes of merchantable timber.

09 BIOMASS FUELS↗

Guest Editorial: Planning and operation of resilient distribution system for integrated multi-energy

Resilience is the ability of power systems to prepare for and adapt to low-probability, high-impact incidents and withstand and recover rapidly from disruptions. With the ageing of electricity distribution infrastructure and increasing threats of weather-related incidents and natural disasters, the need to effectively enhance the resilience of the electricity distribution system has become urgent and has attracted worldwide attention. Although there are an increasing number of publications related to enhancing resilience strategies, resilience is an emerging concept in power systems. Existing practices are mostly focused on deploying distributed energy resources (DERs) and microgrids, hardening the existing infrastructures and building redundant capacities. However, from a broader perspective, resilience enhancement of power distribution system is a systematic engineering, involving long-term system planning and upgrading (e.g., deployment of smart grid technologies and intelligent switches), short-term proactive scheduling, real-time robust and resilient control of DERs, and post-event restoration and recovery strategies. Based on this point, this Special Issue in IET Energy System Integration focuses on soliciting the most recent and original technologies, scheduling and control strategies for improving the resilience of power distribution system. Eight papers are presented in this Special Issue, covering various aspects related to resilience enhancement of power distribution system, including fault-tolerant frequency measurement, robust scheduling of integrated electricity and district heating systems, robust control of DERs, efficient methods for safety verification as well as novel graph theory-based approach to restore the distribution systems after multiple simultaneous faults. A brief introduction of these 8 papers is provided below.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demographic Microsimulator for Integrated Urban Systems: Adapting Panel Survey of Income Dynamics to Capture the Continuum of Life

Agent-based models (ABMs) in transportation modeling simulate activity and travel decisions at the disaggregate level of households and individuals. To do this, ABMs require detailed and realistic information on agents’ socioeconomic and demographic characteristics. Various synthetic population generators have been proposed to address this need. However, most of those currently in practice are cross-sectional in nature and do not account for the dynamics within households and individuals as they progress through life events over time. This is a major shortcoming, as literature has shown that transportation decisions are affected by the transition between and co-occurrence of life cycle events. While some demographic evolution simulators have been proposed to address this issue, they are developed using cross-sectional data and capture only a small set of life cycle events and their interdependence. Addressing these drawbacks, we propose a demographic microsimulator (DEMOS) that captures the “continuum of life” by considering a range of household- and individual-level life cycle events. DEMOS is developed using the Panel Survey of Income Dynamics, one of the world’s longest-running longitudinal surveys. The DEMOS submodels consider key life cycle events that are influenced by agents’ demographic variables. DEMOS is applied to evolve the population of the San Francisco Bay Area over a 9-year horizon. Results demonstrate how DEMOS generates life trajectories and how DEMOS outputs match the observed demographic trends. DEMOS is expected to enable longitudinal analysis in the context of ABMs and expand ABMs analyses relating to dynamic processes such as household-level vehicle transactions.

Demographic evolution↗

Complementarities of supply and demand sides in integrated energy systems

New small-scale demand-side technologies, such as micro combined heat and power technologies (uCHPs) and heat pumps (HPs), offer opportunities to increase system-wide efficiency. Furthermore, the technical and economic characteristics of demand-side technologies could also complement the supply side by providing system services, such as adequacy and flexibility, which are increasingly required due to high variable renewable energy penetration. A capacity expansion methodology that captures the interactions between the supply and demand sides is developed to find cost-optimal and adequate investment portfolios. For the case study presented, the integrated energy system leverages the technical and economic complementarities of different supply and demand-side technologies. As a result, system integration using demand-side technologies improves the value proposition for decentralization given that the technologies can provide heat demand, while also meeting electricity demand and providing adequacy and flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and Implementation: Integrating Unmanned Aircraft Systems into Physical Protection Systems at Fixed Sites and During Transportation

Physical protection systems, and response forces in particular, are designed to prevent an adversary from successfully completing a malevolent act against a facility or transport operations. Timely detection and assessment of any potential adversary action against a target is an essential element of materials security. The timely detection and assessment must then be followed-up by a capable and timely response that might be enhanced with the additional situational awareness provided by unmanned aircraft systems (UAS). The United States Department of Energy’s National Nuclear Security Administration Office of International Nuclear Security has been exploring capabilities provided by UAS to support response force operations within the physical protection system. UAS have the potential to provide response force commanders and operators with situational awareness in assessing adversary locations and actions as well as the locations of responders. UAS may be utilized for area searches ahead of responder pathways to identify potential threats and to provide situational awareness of areas not normally covered by cameras (such as areas outside the fence line outside at fixed facilities). In addition, UAS can provide real-time information to transportation convoy teams that pass through constantly changing public access environments. This paper will provide operational recommendations to be addressed when integrating UAS into existing physical protection systems at fixed sites and during transport. Recommendations will include aspects of the following: needs analysis; tactics and techniques to support detection and assessment as well as response force deployment; remote pilot selection, qualifications, training, and currency; UAS selection criteria; UAS laws and regulations; possible cost sharing with other facility operations; and on-scene emergency management.

Stockwell, Brandon↗

ARIES: Advanced Research on Integrated Energy Systems Research Plan

The Advanced Research on Integrated Energy Systems (ARIES) platform is one of the most powerful research environments anywhere for addressing the speed and scale of change on power systems. This research plan details ARIES capabilities, current and upcoming, and how they relate to objectives for advanced energy systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Energy Systems: 2020 Roadmap

This roadmap defines potential industrial scale integrated energy systems (IES) and identifies key technology gaps to achieving commercial deployment of such systems. IES under consideration could include multiple energy generation resources and energy use paths, with a focus on low-emission technologies, such as nuclear and renewable generators. Together these technologies provide affordable, reliable, and resilient energy while simultaneously reducing environmental emission of CO 2 and greenhouse gases (GHGs). System design and optimization would consider both technical performance and economic viability within various deployment markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Engineering-Scale Integrated Energy System Data Projection Demonstration via the Dynamic Energy Transport and Integration Laboratory

The objective of this study is to demonstrate and validate the Dynamic Energy Transport and Integration Laboratory (DETAIL) preliminary scaling analysis using Modelica language system-code Dymola. The DETAIL preliminary scaling analysis includes a multisystem integral scaling package between thermal-storage and hydrogen-electrolysis systems. To construct the system of scaled equations, dynamical system scaling (DSS) was applied to all governing laws and closure relations associated with the selected integral system. The existing Dymola thermal-energy distribution system (TEDS) facility and high-temperature steam electrolysis (HTSE) facility models in the Idaho National Laboratory HYBRID repository were used to simulate a test case and a corresponding scaled case for integrated system HYBRID demonstration and validation. The DSS projected data based on the test-case simulations and determined scaling ratios were generated and compared with scaled case simulations. The preliminary scaling analysis performance was evaluated, and scaling distortions were investigated based on data magnitude, sequence, and similarity. The results indicated a necessity to change the normalization method for thermal storage generating optimal operating conditions of 261 kW power and mass flow rate of 6.42 kg/s and the possibility of reselecting governing laws for hydrogen electrolysis to improve scaling predictive properties. To enhance system-scaling similarity for TEDS and HTSE, the requirement for scaling validation via physical-facility demonstration was identified.

08 HYDROGEN↗