High- and Mid-Fidelity Modeling Comparison for a Floating Marine Turbine System: Preprint

There is a lack of suitable numerical tools, particularly open-source tools, that can be used for designing and optimizing marine turbine systems. The National Renewable Energy Laboratory (NREL) has added features to their widely used mid-fidelity wind turbine modeling code, OpenFAST, to enable modeling of axial flow marine turbines. This necessitated the addition of several physical effects relevant to marine turbines that can be neglected for wind turbines. These include buoyant loads, added mass and inertia loads, wave-current superposition, and changes to the coordinate systems. This updated version of OpenFAST allows for the modeling of both fixed and floating marine turbine systems at a speed comparable to real time. While efficient for long simulations, large sets of load cases, and design studies, mid-fidelity codes cannot capture all of the potentially important physical phenomenon impacting marine turbine systems. High-fidelity computational fluid dynamics (CFD) simulations can capture more flow effects with fewer assumptions and provide detailed body pressure mapping and flow-field information. It is important to compare predictions between mid-fidelity and high-fidelity codes, both to verify the models and to understand the limitations. A floating marine turbine system designed by NREL was modeled both with OpenFAST and with the commercial CFD code, STARCCM+. The CFD model used a 3-D unsteady Reynolds-averaged Navier-Stokes solver for a volume-of-fluid numerical wave and current tank. The blade-resolved simulations used the sliding-interface technique for the spinning rotor and an overset grid to accommodate the rigid-body motion of the floating system. The mooring system was modelled with a custom coupling of the CFD solver with the open-source code, MoorDyn. This improves upon the existing quasi-static catenary solver in STARCCM+, which lacks seabed contact or line-to-line connections. Spatial and temporal convergence studies were conducted. The simulation results for a combined current and wave condition are compared between OpenFAST and CFD, highlighting the capabilities of the mid-fidelity code and identifying the areas where a high-fidelity approach is needed.

CFD↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs: Preprint

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, for small-scale radial microgrids, we demonstrate the ability of IBRs to tune the effective transfer functions of synchronous machines. This enables us to relax the uniform turbine time-constant assumptions and widen the scope of existing synchronization results for proportionally heterogeneous machines.

frequency-shaping control↗

Interoperable, Inverter-Based Distributed Energy Resources (DERs) Enable 100% Renewable and Resilient Utility Microgrids

Project overcomes frequency stability and system control issues when operating distribution microgrids in a low inertia, high PV penetration environment without fossil fuel generators. The team implemented a grid-forming inverter and advanced control features at SDG&E's Borrego Springs Microgrid to demonstrate islanding and blackstart using renewable resources. Simulation and emulation in advance of deployment de-risks field operations.

battery energy storage systems↗

High Penetration Microgrids Providing Grid Stability Using Frequency-Watt Control Presentation

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint.Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

13 HYDRO ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Resilient Distributed Frequency Regulation of Renewable Generators under Communication Interruptions

Modern power systems (MPSs) face significant challenges due to the high penetration of renewable energy sources (RESs) and new types of loads such as electric vehicles (EVs). Traditional load frequency control (LFC) methods struggle with the intermittent, stochastic nature of RESs, the near-zero inertia of power-electronics-based generators, and the mobility of controllable loads and battery systems. This paper introduces a novel resilient distributed frequency regulation method to address these issues. The proposed method employs a state space model to represent the dynamic behavior of participating power sources while accounting for stochastic switching processes to model structural and parameter variations caused by disruptions such as generator connection/disconnection, communication interruptions, and physical faults. By integrating these dynamic and stochastic components, the method treats power grids as a comprehensive stochastic hybrid system. Our method enhances conventional frequency control by incorporating local stability control, neighborhood control decoupling, and coordination feedback. Theoretical analyses establish the stability, convergence, and resilience of the proposed method, and its effectiveness is validated through case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Functional Data Analysis in Wearable Body Sensor Networks

Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.

60 - APPLIED LIFE SCIENCES↗

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗

Advancing Mass Timber Buildings: Novel Methods Improve Thermal Assessment and Material Use

For nearly a century, thermal demand calculations for buildings have relied on simplified models developed to match the technical constraints of their era. The first standards, introduced in Germany and Austria in 1929, established climate zones and material conductivity coefficients that, with only incremental updates, still underpin many current assessments. Yet, methods such as Hot box testing, originally designed for lightweight insulation, continue to be applied for mass timber buildings, overlooking thermodynamic characteristics confer real-world advantages. Recent research at Oak Ridge National Laboratory incorporates updated methodologies, aligned with ASHRAE Standard 55 (ASHRAE, 2023) accounting for factors such as thermal inertia, inner surface temperatures, emissivity, solar gains, and dynamic outdoor conditions. These factors better reflect observed heating and cooling loads and highlight opportunities for efficient use of materials in mass timber construction. This work provides a framework for designing comfortable, resilient, and resource-efficient buildings while aligning with performance expectations in energy codes.

Pickett, Robert [International Mass Timber Allianc↗

An efficient method to integrate polynomials over polytopes and curved solids

Here in this paper, we present an efficient approach to compute the integral of monomials and polynomials over polyhedra and regions defined by parametric curved boundary surfaces. We use Euler's theorem for homogeneous functions in combination with Stokes's theorem to reduce the integration of a monomial over a three-dimensional solid to its boundary. If the solid is a polytope, through a recursive application of these theorems, the integral is further reduced to just the evaluation of the monomial and its derivatives at the vertices of the polytope. The present approach is simpler than existing techniques that rely on repeated use of the divergence theorem, which require the antiderivative of the monomials and the projection of these functions onto hyperplanes. For convex and nonconvex polytopes, our approach does not introduce any approximation for the integration of monomials. For curved solid regions bounded by surfaces that admit a parameterization, the same approach yields simplified formulas to compute the integral of any homogeneous function, including monomials. For surfaces parameterized by polynomial surfaces (such as Bezier surface triangles and B-spline patches), the method yields machine-precision accuracy for the volumetric integration of monomials with an appropriate quadrature rule. Numerical examples over regions bounded by polynomial surfaces and rational surfaces are presented to establish the accuracy and efficiency of the method.

97 MATHEMATICS AND COMPUTING↗

Stabilizing Inverter-Based Transmission Systems: Power Hardware-in-the-Loop Experiments with a Megawatt-Scale Grid-Forming Inverter

This article presents what the authors believe to be the first experimental verification of the ability of grid-forming (GFM) inverters to stabilize a transmission electric power system that is otherwise unstable. The experiments described here were performed using power hardware-in-the-loop (PHIL) simulation to connect a megawatt-scale battery inverter to a real-time electromagnetic transient (EMT) simulation of the near-future Maui power system. This allows the dynamic interactions between the inverter and the power system to be observed without putting the real power system at risk. The ability to use the actual inverter hardware removes the need to rely on a computer model approximation of the inverter's behavior.

electromagnetic transient simulations↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Roles of Dynamic State Estimation in Power System Modeling, Monitoring and Operation

—Power system dynamic state estimation (DSE) remains an active research area. This is driven by the absence of accurate models, the increasing availability of fast-sampled, time synchronized measurements, and the advances in the capability, scalability, and affordability of computing and communications. This paper discusses the advantages of DSE as compared to static state estimation, and the implementation differences between the two, including the measurement configuration, modeling framework and support software features. The important roles of DSE are discussed from modeling, monitoring and operation aspects for today’s synchronous machine dominated systems and the future power electronics-interfaced generation systems. Several examples are presented to demonstrate the benefits of DSE on enhancing the operational robustness and resilience of 21st century power system through time critical applications. Future research directions are identified and discussed, paving the way for developing the next generation of energy management systems.

Zhao, Junbo↗

Analytical Models of Frequency and Voltage in Large-Scale All-Inverter Power Systems

Low-order frequency response models for power systems have a decades-long history in optimization and control problems such as unit commitment, economic dispatch, and wide-area control. With a few exceptions, these models are built upon the Newtonian mechanics of synchronous generators, assuming that the frequency dynamics across a system are approximately homogeneous, and assume the dynamics of nodal voltages for most operating conditions are negligible, and thus are not directly computed at all buses. As a result, the use of system frequency models results in the systematic underestimation of frequency minimum nadir and maximum RoCoF, and provides no insight into the reactive power-voltage dynamics. This paper proposes a low-order model of both frequency and voltage response in grid-forming inverter-dominated power systems. The proposed model accounts for spatial-temporal variations in frequency and voltage behavior across a system and as a result, demonstrates the heterogeneity of frequency response in future renewable power systems. Electromagnetic transient (EMT) simulations are used to validate the utility, accuracy, and computational efficiency of these models, setting the basis for them to serve as fast, scalable alternatives to EMT simulation, especially when dealing with very large-scale systems, for both planning and operational studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast Grid Frequency Support from Distributed Energy Resources

This report describes research related to electric power system frequency support from inverter-coupled distributed energy resources (DERs). This research was initiated under the U.S. Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) and also contains work funded through a Cooperative Research and Development Agreement with Hawaiian Electric. The purpose of this report is to summarize the findings of simulations, hardware testing, power hardware-in-the-loop (PHIL) simulation, and analysis examining the effects of DER frequency support on the Oahu power system. This report also includes recommendations for consideration in the use of DER grid frequency support functionality, and related topics. Note that a previous GMLC Technical Report from this project also provided specific recommendations for the activation of one specific grid frequency support function, frequency-watt control, for overfrequency events in Hawaii. Those recommendations included recommended frequency-watt control settings, which have since been approved by the Hawaii Public Utilities Commission on October 20, 2017, for system-wide activation. This report builds on the previous report by considering not only overfrequency events but also underfrequency events, and by considering distributed energy storage systems in addition to photovoltaic (PV) systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗