Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Impact loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Caldera_Grid

Caldera Grid is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. Caldera Grid is a co-simulation framework implemented using Hierarchical Engine for Large scale Infrastructure Co-Simulation (HELICS). The framework facilitates the co-simulation of EV charging and Smart Charge Management (SCM) strategies in Caldera Infrastructure Charge Model (ICM) with distribution level grid models in OpenDSS. Vehicle energy needs and charge session requirements generated using Caldera Charge Decision Module (CDM) are fed in as input to Caldera Grid. The EV charging models in Caldera ICM simulates both the uncontrolled charging loads as well as loads modified by the SCM strategies to develop distributed load profiles for each grid node hosting an Electric Vehicle Supply Equipment (EVSE) – also known as chargers. These loads were simulated in OpenDSS alongside existing distribution feeder loads. Each of these models are co-simulated in a HELICS federate. The HELICS co-simulation framework facilitates communication and synchronization between the federates. By co-simulating EV loads and distribution feeder loads, Caldera Grid can assess the potential grid impacts of EV charging on distribution feeders under various grid conditions. A control strategy federate is implemented with an interface where control strategies based on feedback from EV charging status and grid conditions can be developed and implemented. The platform can also support multiple control strategies in a single co-simulation.

Sundarrajan, ManojKumar Cebol↗

Optimized Renewable Energy Integration for EV High-Power Dynamic Wireless Charging Systems

Dynamic wireless charging for electric vehicles is an emerging technology to reduce on-board battery size and extend driving range. Due to its unique characteristic of vehicle-speed-related pulse-like load profile, the high-power dynamic wireless charging system (DWCS) introduces high stress to the utility grid. In this paper, an optimization model for renewable energy integration in the DWCS is proposed to mitigate the grid impact and minimize the operation costs of the whole system. As the load profile of DWCS is related to the traffic volume and various approaching vehicle speeds, the annual average daily traffic data and a stochastic model are used to develop 24-hour load profile of DWCS. To find a tradeoff between grid impact mitigation and operation costs minimization, relationships among power demand from power grid, photovoltaic (PV) capacity, wind energy (WE) capacity and energy storage (ES) capacity are analyzed, and the optimization objective and constraints are developed. Numerical simulation results demonstrate that energy storage integration can greatly mitigate the grid impact of DWCS, and optimal ratio of PV and WE can significantly reduce the operation cost of DWCS.

Zeng, Rong↗

Electrification Futures Study: Power Systems Operation with Newly Electrified and Flexible Loads

The Electrification Futures Study (EFS) is a multi-year study designed to analyze the impacts of widespread electrification in the U.S. energy system. In this webinar we present the detailed power systems operational analysis from the final report in the EFS series. For this analysis, we simulate multiple 2050 power systems for the conterminous United States to assess how variations in the magnitude and shape of electricity demand driven by electrification, and the extent of load participation to more-actively provide grid services, might impact the hourly operation, operational costs, and emissions of various power systems in 2050. The impacts of electrification and demand flexibility are overlayed across systems with significantly greater penetrations of variable renewable energy than today. Overall, we find that the high electrification scenarios envisioned in the EFS with significant VRE penetration (66% of annual national generation) can be operated to meet future increased levels of electrified demand. We also find that demand-side flexibility can enhance operational efficiency and reduce overall annual production costs by $5-$10 billion. The complementary relationship between flexible electric vehicle charging loads and solar generation is particularly pronounced, but in the absence of demand-side flexibility electrification can lead to increased wind and solar curtailment. By helping to reduce renewable curtailment, flexibility can also reduce power sector CO2 emissions. The analysis highlights the value of increased integration and coordination of demand- and supply-side resources in future electric system planning and operations—particularly under high electrification futures.

43 PARTICLE ACCELERATORS↗

Nitrate loading projection is sensitive to freeze-thaw cycle representation

Climate change can have substantial impacts on nitrogen runoff, which is a major cause of eutrophication, harmful algal blooms, and hypoxia in freshwaters and coastal regions. We examined responses of nitrate loading to climate change in the Upper Mississippi River Basin (UMRB) with an enhanced Soil and Water Assessment Tool with physically based Freeze-Thaw cycle representation (SWAT-FT), as compared with the original SWAT model that employs an empirical equation. Driven by future climate projections from five General Circulation Models (GCMs) from 1960 to 2099 under the Representative Concentrations Pathways (RCP) 8.5 scenario, we analyzed changes in riverine nitrate loadings, as well as terrestrial surface and subsurface contributions of the UMRB in the 21st century relative to the baseline period of 1960–1999. By the end of the 21st century, the original SWAT model predicted about a 50% increase in riverine nitrate loadings which is nearly twice as much as that estimated by SWAT-FT (ca. 25%). Such a large difference in projected nitrate changes can potentially mislead mitigation strategies that aim to reduce nitrogen runoff from the UMRB. Further analysis shows that the difference between the original SWAT model and SWAT-FT led to substantial discrepancies in the spatial distribution of surface and subsurface nitrate loadings in the UMRB. In general, SWAT-FT predicted more nitrate leaching for northwestern parts of the UMRB which are more sensitive to freeze-thaw cycle, mainly because SWAT-FT simulated less frequent frozen soils. This study highlights the importance of using physically based freeze-thaw cycle representation in water quality modeling. Design of future nitrogen runoff reduction strategies should include careful assessment of effects that land management has on the freeze-thaw cycles to provide reliable projection of water quality under climate change.

Wang, Qianfeng↗

Microgrid Resilience: A Holistic and Context-Aware Resilience Metric

Microgrids present an effective solution for the coordinated deployment of various distributed energy resources and furthermore provide myriad additional benefits such as resilience, decreased carbon footprint, and reliability to energy consumers and the energy system as a whole. Boosting the resilience of distribution systems is another major benefit of microgrids. This is because they can also serve as a backup power source when the utility grid's operations are interrupted due to either high-probability low-impact events like a component failure or low-probability high-impact events - be it a natural disaster or a planned cyberattack. However, the degree to which any particular system can defend, adapt, and restore normal operation depends on various factors including the type and severity of events to which a microgrid is subjected. These factors, in turn, are dependent on the geographical location of the deployed microgrid as well as the cyber risk profile of the site where the microgrid is operating. Therefore, in this work, we attempt to capture this multi-dimensional interplay of various factors in quantifying the ability of the microgrid to be resilient in these varying aspects. This paper, thus, proposes a customized site-specific quantification of the resilience strength for the individual microgrid's capability to absorb, restore, and adapt to the changing circumstances for sustaining the critical load when a low-probability high-impact event occurs - termed as - context-aware resilience metric. We also present a case study to illustrate the key elements of our integrated analytical approach.

microgrid↗

Impacts of wind field characteristics and non-steady deterministic wind events on time-varying main-bearing loads

Abstract. This work considers the characteristics and drivers of the loads experienced by wind turbine main bearings. Simplified load response models of two different hub and main-bearing configurations are presented, representative of both inverting direct-drive and four-point-mounted geared drivetrains. The influences of deterministic wind field characteristics, such as wind speed, shear, yaw offset, and veer, on the bearing load patterns are then investigated for similarity scaled 5, 7.5, and 10 MW reference wind turbine models. Main-bearing load response in cases of deterministic gusts and extreme changes in wind direction are also considered for the 5 MW model. Perhaps surprisingly, veer is identified as an important driver of main-bearing load fluctuations. Upscaling results indicate that similar behaviour holds as turbines become larger, but with mean loads and load fluctuation levels increasing at least cubically with the turbine rotor radius. Strong links between turbine control and main-bearing load response are also observed.

17 WIND ENERGY↗

A Comparative Study of Compressive Effects on the Morphology and Performance of Carbon Paper and Cloth Electrodes in Redox Flow Batteries

Compressing porous carbon electrodes is a common approach to improve flow battery performance, but the resulting impact on electrode structure, fluid dynamics, and cell performance is not well understood. Herein, microtomographic imaging, load cell testing, and flow cell diagnostics are employed to characterize how compression‐induced changes impact pressure drop, polarization, and mass‐transfer scaling. Five different compressions are tested, spanning ranges typically used in literature, for AvCarb 1071 cloth (0%, 9%, 20%, 25%, 32%) and Freudenberg H23 paper (0%, 8%, 12%, 17%, 22%). It is found that the two electrode structures have distinct responses to compression, resulting in differing optimal conditions identified for each material; specifically, the Freudenberg H23 exhibits lower combined ohmic, charge‐transfer, and mass‐transport values at 8% compression, resulting in improved electrochemical performance across all compressive values, as compared to the optimal AvCarb 1071 compression (20%). Overall, Freudenberg H23 exhibits a greater sensitivity to compression with peak electrochemical activity correlating with increased permeability, whereas AvCarb 1071 is insensitive to compressive loads but produces lower electrochemical performance. Herein, the trade‐offs of mechanical robustness on fluid‐dynamic and electrochemical performance between the two electrodes are demonstrated by the aforementioned findings, suggesting each could be used for specific operating environments.

25 ENERGY STORAGE↗

Modelling of edge plasma dynamics with active wall boundary conditions

A self-consistent 2D model is presented for transport in boundary plasma and plasma-facing material walls. Plasma dynamics in the domain is represented by a 2D collisional plasma fluid model in the edge-plasma code UEDGE, and transport of hydrogen and heat in the wall is represented by a system of reaction–diffusion equations in the 1D wall code FACE. To account for variation of parameters along the wall, in the coupled model multiple instances of the FACE code run in parallel. Here, the coupled model provides a tool for investigating a range of dynamic plasma–material interactions phenomena in 2D. For demonstration of its capability, one application of particular interest is the role of active wall in tokamak strike point sweeping proposed for mitigation of divertor heat loads. In the present study, the coupled calculations are applied to investigation of the impact of heat and hydrogen transport in the material wall on the divertor plasma and target heat load during sweeping of the target strike point for parameters of a high-power tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Dynamic Pricing Method to Manage the Impact of EV Charging on the Grid Using RL

This work addresses the challenge of managing electrical vehicle (EV) charging loads on distribution feeders with the increase in deployment of fast charging stations. To mitigate the adverse impacts on feeder health, a novel dynamic grid-informed pricing approach is proposed. This approach leverages reinforcement learning (RL) to determine hourly charging prices based on real-time grid conditions. A synthetic environment was developed to train the reinforcement learning agent. A model of an IEEE 34-bus distribution feeder with EV charging stations has been developed in OpenDSS utilizing Caldera for realistic EV charging profiles. Test cases demonstrate that the dynamic pricing strategy achieves higher energy delivery to the EV end user at a lower cost compared to constant pricing methods, while lowering voltage deviations and congestion. This approach offers more granular price adjustments, responding dynamically to feeder conditions and potentially improving grid stability and efficiency. The communication architecture to implement this dynamic pricing method is described. This research contributes to the development of smart grid-informed charging solutions that can reduce the cost of charging to the end user while also helping the grid.

EV charging, dynamic pricing, grid-informed chargi↗

A dynamic pricing method to manage the impact of EV charging on the grid using RL

This work addresses the challenge of managing electrical vehicle (EV) charging loads on distribution feeders with the increase in deployment of fast charging stations. To mitigate the adverse impacts on feeder health, a novel dynamic grid-informed pricing approach is proposed. This approach leverages reinforcement learning (RL) to determine hourly charging prices based on real-time grid conditions. A synthetic environment was developed to train the reinforcement learning agent. A model of an IEEE 34-bus distribution feeder with EV charging stations has been developed in OpenDSS utilizing Caldera for realistic EV charging profiles. Test cases demonstrate that the dynamic pricing strategy achieves higher energy delivery to the EV end user at a lower cost compared to constant pricing methods, while lowering voltage deviations and congestion. This approach offers more granular price adjustments, responding dynamically to feeder conditions and potentially improving grid stability and efficiency. The communication architecture to implement this dynamic pricing method is described. This research contributes to the development of smart grid-informed charging solutions that can reduce the cost of charging to the end user while also helping the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the life-cycle environmental impacts of the wood pallet sector in the United States

Wood pallets play a critical role in the movement and storage of goods worldwide. They are an important component in the complex global supply chain and used by almost every industry. It is therefore important to assess the environmental implications of the wood pallet supply chain and identify optimization strategies that can be implemented. In this paper, primary 2018 annual production data collected from U.S. pallet manufacturers were used to develop the first industry-average life-cycle inventory (LCI). A new functional unit was proposed to perform a more refined and accurate environmental life-cycle assessment of the wood pallet supply chain. Using the LCI data developed, a cradle-to-grave industry-average life-cycle impact assessment was performed. This novel approach quantifies environmental impacts of a generic multi-use pallet, including repair and remanufacturing. The total global warming impact was 10.4 kg CO 2 e per 45.4 t of pallet loads of product delivered using wood pallets. The manufacturing stage contributed the most, about 35%, followed by the raw material supply stage. About 41% of total primary energy consumption was from renewable sources, with most sourced from biomass. Fossil fuels comprised about 52% of the total (225 MJ per functional unit) primary energy consumption. Total environmental impact was significantly affected by two main parameters: reference service life and load-bearing capacity. Pallet repair was also found to be an important component of the wood pallet supply chain, which has a low environmental footprint compared with the overall impact of a pallet and enables mitigation of overall impact by extending the reference service life. Finally, at end-of-life, common industry practices demonstrated substantial potential environmental benefits that can minimize overall environmental impact.

54 ENVIRONMENTAL SCIENCES↗

An overview of 3D field optimization for control of transport and edge instabilities on KSTAR

An international team from several laboratories and universities has made key advances over the last few years in the control of plasma transport and edge instabilities with applied 3D fields in the KSTAR tokamak to optimize long pulse operation scenarios. This overview begins with the optimization of both core and edge resonant magnetic perturbations (RMP) to improve fast ion confinement to avoid excessive limiter heat loads due to fast ion losses and successful modeling of the experimental results. Integrated and advanced plasma control techniques with machine learning (ML) and adaptive control were then used to optimize the 3D field spectrum in real-time to control edge localized modes (ELMs) while avoiding core locked modes that could disrupt the plasma. Accelerating the offline model of 3D fields with a surrogate ML model can optimize ELM suppression in the edge while limiting the impact of the applied RMP fields deeper in the plasma core in real-time. In addition, the impact of the 3D fields on the divertor heat load has been modeled and compared with experimental measurements. An analysis of a multi-machine database including KSTAR has been performed to better understand the metrics for the observed RMP thresholds for ELM suppression and the resulting plasma performance. Predictive modeling of the operational space for ELM suppression and density pumpout due to RMP has shown the importance of magnetic islands in the plasma edge and their impact on plasma turbulence. This research has culminated in the development of successful long pulse operational scenarios on KSTAR while attempting to overcome challenges of the new tungsten divertor.

3D fields↗

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Electrolysis on a Chip with Tunable Thin Film Nanostructured PGM Electrocatalysts Generated from Self-Assembled Block Copolymer Templates

Self-assembled block copolymers are promising templates for fabricating thin film materials with tuned periodic feature sizes and geometry at the nanoscale. Here, a series of nanostructured platinum and iridium oxide electrocatalysts templated from poly(styrene)-block-poly(vinyl pyridine) (PSbPVP) block copolymers via an incipient wetness impregnation (IWI) pathway is reported. Both nanowire and nanocylinder electrocatalysts of varying feature sizes are assessed and higher catalyst loadings are achieved by the alkylation of the pyridine moieties in the PVP block prior to IWI. Electrocatalyst evaluations featuring hydrogen pump and water electrolysis demonstrations are carried out on interdigitated electrode (IDE) chips flexible with liquid supporting electrolytes and thin film polymer electrolytes. Notably, the mass activities of the nanostructured electrocatalysts from alkylated block copolymer templates are 35%–94% higher than electrocatalysts from non-alkylated block copolymer templates. Standing cylinder nanostructures lead to higher mass activities than lamellar variants despite their not having the largest surface area per unit catalyst loading demonstrating that mesostructure architectures have a profound impact on reactivity. Overall, IDE chips with model thin film electrocatalysts prepared from self-assembled block copolymers offer a high-throughput experimental method for correlating electrocatalyst nanostructure and composition to electrochemical reactivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Idealized Offshore Low‐Level Jets for Turbine Structural Impact Considerations

Low-level jets (LLJs) describe conditions in which the wind speed reaches a local maximum with respect to altitude near the surface; they have been observed intermittently in the US mid-Atlantic offshore environment. LLJs pose unique operating conditions for future wind turbines operating in the region, such as negative shear and locally strong veer, but they are not typically considered in existing turbine standards. This work builds upon recent research that explains the formation and evolution of the US mid-Atlantic LLJs through a simple analytical governing equation. We generate several LLJ inflow conditions with varying jet characteristics based on this analytical model and create monotonically sheared (MS) analogues with matched veer to assess the impacts of the LLJ on turbine performance and loading. Using aeroelastic simulations with these inflow conditions on the International Energy Agency 15-MW reference turbine, we find that the LLJ leads to a greater range of tower-top pitching and yawing moments, which could contribute to larger accumulated structural fatigue in components compared to MS inflow. These preliminary results demonstrate a path toward a unified set of test cases for low-level wind maxima that can inform the International Electrotechnical Commission standards related to offshore wind turbine design.

17 WIND ENERGY↗

Consumer safety-oriented scheduling of rotating power outages during heat waves

Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.

Building thermal simulation↗

Correlation between Generator Trips and Locational Marginal Prices (LMPs)

Generally, disturbances in an interconnected network have an influence the stability and the economy of the power grid. Some phenomenon such as load shedding have proven to have a huge impact on real time electricity prices. Generation trip is considered one of the most common events in a power grid that may change the wholesale electricity market. In this paper, a locational marginal price (LMP) measure is used to notice how the electricity prices change with generator trip events at different locations of U.S. power grid. The study results help to find whether there is a clear correlation between generator trips and the changes in the electricity real-time market.

Alharbi, Abdulelah↗

Mitigating Cascading Outages in Severe Weather Using Simulation-Based Optimization

Severe weather events can trigger cascading power outages and lead to significant losses. In this work, we investigate cascading outage mitigation under severe weather conditions. Given day-ahead weather forecasts and component failure models, we aim to identify a set of power lines that can be hardened to minimize the expected impact of potential cascading outages. Since the expected load shedding cannot be expressed as an explicit function of line hardening decisions and system states, we developed a cascading outage simulator to estimate the expected value of load shedding under various initial weather-related disruption scenarios generated using a weather forecast. To avoid massive enumeration of all possible combinations of line hardening decisions and reduce the simulation efforts, we employed an efficient simulation-based optimization approach that quickly identifies the (near) optimal line hardening decisions in the presence of both large simulation noises due to the highly variable initial disturbances and system states, and significant randomness in the subsequent cascades. Furthermore, the algorithm is also able to utilize parallel computing to dramatically reduce computation time to support decision making in preparation for severe weather conditions. We performed a case study on the Northeast Power Coordinating Council (NPCC) 140-bus system model to demonstrate that our approach can significantly improve power grid resilience to adverse weather events.

24 POWER TRANSMISSION AND DISTRIBUTION↗