Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Telescope for x ray and gamma ray studies in astrophysics

Imaging of x-rays has been achieved by various methods in astrophysics, nuclear physics, medicine, and material science. A new method for imaging x-ray and gamma-ray sources avoids the limitations of previously used imaging devices. Images are formed in optical wavelengths by using mirrors or lenses to reflect and refract the incoming photons. High energy x-ray and gamma-ray photons cannot be reflected except at grazing angles and pass through lenses without being refracted. Therefore, different methods must be used to image x-ray and gamma-ray sources. Techniques using total absorption, or shadow casting, can provide images in x-rays and gamma-rays. This new method uses a coder made of a pair of Fresnel zone plates and a detector consisting of a matrix of CsI scintillators and photodiodes. The Fresnel zone plates produce Moire patterns when illuminated by an off-axis source. These Moire patterns are deconvolved using a stepped sine wave fitting or an inverse Fourier transform. This type of coder provides the capability of an instantaneous image with sub-arcminute resolution while using a detector with only a coarse position-sensitivity. A matrix of the CsI/photodiode detector elements provides the necessary coarse position-sensitivity. The CsI/photodiode detector also allows good energy resolution. This imaging system provides advantages over previously used imaging devices in both performance and efficiency.

Weaver, W. D.↗

Retrieving Tarnished Daguerreotype Content Using X-ray Fluorescence Imaging—Recent Observations on the Effect of Chemical and Electrochemical Cleaning Methods

We report a study on the effect of chemical and electrochemical cleaning of tarnished daguerreotypes observed using X-ray fluorescence (XRF) microscopy with a micro-focussed X-ray beam from a synchrotron source. It has been found that, while both techniques result in some success depending on the condition of the plate and the experimental parameters (chemical concentration, voltage, current, etc.) the effect varies, and cleaning is often incomplete. The XRF images using Hg Lα,β at an excitation energy just above the L3 edge threshold produce fine images, regardless of the treatment. This finding confirms previous observations that if the bulk of the image particles remains intact, the surface tarnish has little effect on the quality of the original daguerreotype image retrievable from XRF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design study of the accessible focal plane telescope for shuttle

The design and cost analysis of an accessible focal plane telescope for Spacelab is presented in blueprints, tables, and graphs. Topics covered include the telescope tube, the telescope mounting, the airlock plus Spacelab module aft plate, the instrument adapter, and the instrument package. The system allows access to the image plane with instrumentation that can be operated by a scientist in a shirt sleeve environment inside a Spacelab module.

Source record↗

Bathymetric imaging

Digital topography has, for some years, been formatted and processed into shaded relief images for specific studies involving land use and thermal properties. Application to bathymetry is a new and seemingly fruitful extension of these techniques. Digital terrain models of the earth - combining subaerial topography with an extensive collection of bathymetric soundings - have been processed to yield shaded relief images. These images provide new and exciting insights into submarine geomorphology and portray many aspects of plate tectonic physiography in a manner not previously possible.

Paluzzi, P. R.↗

A mechanism for tectonic deformation on Venus

In the absence of identifiable physiographic features directly associated with plate tectonics, alternate mechanisms are sought for the intense tectonic deformation observed in radar images of Venus. One possible mechanism is direct coupling into an elastic lithosphere of the stresses associated with convective flow in the interior. Spectral Green's function solutions have been obtained for stresses in an elastic lithosphere overlying a Newtonian interior with an exponential depth dependence of viscosity, and a specified surface-density distribution driving the flow. At long wavelengths and for a rigid elastic/fluid boundary condition, horizontal normal stresses in the elastic lid are controlled by the vertical shear stress gradient and are directly proportional to the depth of the density disturbance in the underlying fluid. The depth and strength of density anomalies in the Venusian interior inferred by analyses of long wavelength gravity data suggest that stresses in excess of 100 MPa would be generated in a 10 km thick elastic lid unless a low viscosity channel occurring beneath the lid or a positive viscosity gradient uncouples the flow stresses. The great apparent depth of compensation of topographic features argues against this, however, thus supporting the importance of the coupling mechanism. If there is no elastic lid, stresses will also be very high near the surface, providing also that the viscosity gradient is negative.

Phillips, Roger J.↗

Photon counting detectors for Fabry-Perot interferometers

Sealed channel plate photomultipliers with multiple discrete anodes for use as photon counting detectors in the image plane of Fabry-Perot interferometers are described. The influence of design and construction on performance of completed devices is discussed. Effects on spatial resolution, lifetime, and counting efficiency are described. It is shown that devices can be optimized for particular applications. The results should be generally applicable to resistive anode and wedge and strip anode types of sealed detectors.

Darlington, E. H.↗

The Micromechanics of the Moving Contact Line

A transient moving contact line is investigated experimentally. The dynamic interface shape between 20 and 800 microns from the contact line is compared with theory. A novel experiment is devised, in which the contact line is set into motion by electrically altering the solid-liquid surface tension gamma(sub SL). The contact line motion simulates that of spontaneous wetting along a vertical plate with a maximum capillary number Ca approx. = 4 x 10(exp -2). The images of the dynamic meniscus are analyzed as a funtion of Ca. For comparison, the steady-state hydrodynamic equation based on the creeping flow model in a wedge geometry and the three-region uniform perturbation expansion of Cox (1986) is adopted. The interface shape is well depicted by the uniform solutions for Ca <= 10(exp -3). However, for Ca > 10(exp -3), the uniform solution over-predicts the viscous bending. This over-prediction can be accounted for by modifying the slip coefficient within the intermediate solution. With this correction, the measured interface shape is seen to match the theoretical prediction for all capillary numbers. The amount of slip needed to fit the measurements does not scale with the capillary number.

Lichter, Seth↗

Mechanisms of Stationary Crossflow Instability Growth and Breakdown Induced by Forward-Facing Steps

An experimental study is performed to determine the mechanisms by which a forward-facing step impacts the growth and breakdown to turbulence of the stationary cross-flow instability. Particle image velocimetry measurements are obtained in the boundary layer of a 30◦swept flat plate with a pressure body. Step heights range from 53 % to 71 % of the boundary-layer thickness. The critical step height is approximately 60 % of the boundary-layer thickness for the current study, although it is also shown that the critical step height depends on the initial amplitude of the stationary cross-flow vortices. For the critical cases, the stationary cross-flow amplitude grows sharply downstream of the step, decays for a short region and then grows again. The initial growth region is linear, and can be explained primarily through the impact of the step on the mean flow. Namely, the step causes abrupt changes to the mean flow, resulting in large values of wall-normal shear, as well as highly inflectional profiles, due to either cross-flow reversal, separation or both. These inflectional profiles are highly unstable for the stationary cross-flow. Additionally,the reversed flow regions are significantly modulated by the stationary cross-flow vortices. The second region of growth occurs due to the stationary-cross-flow-induced modulation of the shear layer, which leads to multiple smaller wavelength stream wise vortices. High-frequency fluctuations indicate that the unsteady transition mechanism for the critical cases relates to the shedding of vortices downstream of reattachment of the modulated separated regions.

boundary layer stability↗

Hard X-ray and gamma-ray imaging spectroscopy for the next solar maximum

The objectives and principles are described of a single spectroscopic imaging package that can provide effective imaging in the hard X- and gamma-ray ranges. Called the High-Energy Solar Physics (HESP) mission instrument for solar investigation, the device is based on rotating modulation collimators with germanium semiconductor spectrometers. The instrument is planned to incorporate thick modulation plates, and the range of coverage is discussed. The optics permit the coverage of high-contrast hard X-ray images from small- and medium-sized flares with large signal-to-noise ratios. The detectors allow angular resolution of less than 1 arcsec, time resolution of less than 1 arcsec, and spectral resolution of about 1 keV. The HESP package is considered an effective and important instrument for investigating the high-energy solar events of the near-term future efficiently.

Hudson, H. S.↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

MCP-PMT development at Argonne for particle identification

The proposed high-energy high-luminosity polarized Electron-Ion Collider (EIC) demands excellent particle identification over a wide range of particles momenta to achieve the best separation between signal and background particles. Various Cherenkov imaging detector sub-systems are being considered in EIC detector concepts for hadron identification for particles momenta up to 50 GeV/c. One important challenge in this case is to provide a reliable highly pixelated photosensor working in the high radiation and high magnetic field environment. The recently commercialized Large Area Picosecond Photo-Detector (LAPPD) provides a promising low-cost photosensor solution for the various EIC Cherenkov imaging sub-systems. Optimization of the phtosensor design for high magnetic field tolerance, precision timing resolution, and pixelated readout was performed at Argonne National Laboratory with 6 x 6 cm(2) microchannel plate photomultipliers. The techniques and optimized design parameters would be transferrable to industrial partners for low-cost LAPPD production to achieve the demonstrated performance.

atomic layer deposition↗

Advances in photographic X-ray imaging for solar astronomy

The technique of obtaining quantitative data from high resolution soft X-ray photographic images produced by grazing incidence optics was successfully developed to a high degree during the Solar Research Sounding Rocket Program and the S-054 X-Ray Spectrographic Telescope Experiment Program on Skylab. Continued use of soft X-ray photographic imaging in sounding rocket flights of the High Resolution Solar Soft X-Ray Imaging Payload has provided opportunities to further develop these techniques. The developments discussed include: (1) The calibration and use of an inexpensive, commercially available microprocessor controlled drum type film processor for photometric film development; (2) The use of Kodak Technical Pan 2415 film and Kodak SO-253 High Speed Holographic film for improved resolution; and (3) The application of a technique described by Cook, Ewing, and Sutton for determining the film characteristics curves from density histograms of the flight film. Although the superior sensitivity, noise level, and linearity of microchannel plate and CCD detectors attracts the development efforts of many groups working in soft X-ray imaging, the high spatial resolution and dynamic range as well as the reliability and ease of application of photographic media assures the continued use of these techniques in solar X-ray astronomy observations.

Moses, J. Daniel↗

Advances in photographic X-ray imaging for solar astronomy

The technique of obtaining quantitative data from high resolution soft X-ray photographic images produced by grazing incidence optics was successfully developed to a high degree during the AS&E Solar Research Sounding Rocket Program and the S-054 X-Ray Spectrographic Telescope Experiment Program on Skylab. Continued use of soft X-Ray photographic imaging in sounding rocket flights of the AS&E High Resolution Solar Soft X-Ray Imaging Payload has provided opportunities to further develop these techniques. The developments discussed include: (1) the calibration and use of an inexpensive, commercially available microprocessor controlled drum type film processor for photometric film development, (2) the use of Kodak Technical Pan 2415 film and Kodak SO-253 High Speed Holographic film for improved resolution, and (3) the application of a technique described by Cook, Ewing, and Sutton (1988) for determining the film characteristics curves from density histograms of the flight film. Although the superior sensitivity, noise level, and linearity of microchannel plate and CCD detectors attracts the development efforts of many groups working in soft X-ray imaging, the high spatial resolution and dynamic range as well as the reliability and ease of application of photographic media assures the continued use of these techniques in solar X-ray astronomy observations.

Moses, D.↗

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.↗

Optical infrared sky survey instrumentation

An unusual, highly modified, Baker reflector-corrector class telescope has been adapted for wide field survey photography in the near infrared. This optical system uses a full field corrector plate and a field flattening lens to provide a flat field subtending about 4.5 deg on the sky. The small aperture telescope (20 inch primary) has been modified for use in the Newtonian focus configuration while preserving the optical elements of the Prime focus configuration. The telescope has been further modified to accept a very large format (146mm diameter photocathode) image intensifier camera to serve as a detector. The camera output is recorded photographically on film rather than glass plates. This unique instrument system is used in a program of sky survey photography in the optical infrared (8000-9000A bandpass) supplemented by visual bandpass photography. The photographs obtained with this system are of value not only for the extreme redness of the band but also because of their high resolution and their freedom from hydrogen emission.

Craine, E. R.↗

Low-speed flowfield characterization by infrared measurements of surface temperatures

An experimental program was aimed at identifying areas in low speed aerodynamic research where infrared imaging systems can make significant contributions. Implementing a new technique, a long electrically heated wire was placed across a laminar jet. By measuring the temperature distribution along the wire with the IR imaging camera, the flow behavior was identified. Furthermore, using Nusselt number correlations, the velocity distribution could be deduced. The same approach was used to survey wakes behind cylinders in a wind-tunnel. This method is suited to investigate flows with position dependent velocities, e.g., boundary layers, confined flows, jets, wakes, and shear layers. It was found that the IR imaging camera cannot accurately track high gradient temperature fields. A correlation procedure was devised to account for this limitation. Other wind-tunnel experiments included tracking the development of the laminar boundary layer over a warmed flat plate by measuring the chordwise temperature distribution. This technique was applied also to the flow downstream from a rearward facing step. Finally, the IR imaging system was used to study boundary layer behavior over an airfoil at angles of attack from zero up to separation. The results were confirmed with tufts observable both visually and with the IR imaging camera.

Gartenberg, E.↗

Single-frame far-field diffractive imaging with randomized illumination

Contains two transmission ptychography datasets, one collected from a Siemens star, and the second from an Fe/Gd multilayer. Both samples are under illumination from the same randomized zone plate. Each dataset has a single diffraction pattern removed, and these patterns are reported in a separate cxi file. Either ptychography dataset can be used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.

BESSY II↗

Deformation and fracture characteristics of zirconium plate produced via ultrasonic additive manufacturing

Abstract The microstructural evolution, deformation modes, and fracture mechanisms of zirconium plate produced using ultrasonic additive manufacturing (UAM) are presented. In addition to conventional tensile testing techniques, digital image correlation captured highly variable strain accumulation in specimens loaded perpendicular or parallel to the build height (Z). When tested in parallel to Z, delamination at prior foil/foil interfaces creates strain localization noticeable in strain rate maps, whereas specimens loaded perpendicular to Z illustrate conventional strain hardening until necking accelerates delamination. Although bond strengths are statistically and spatially variable, in situ electron backscattering diffraction tests illustrate the ability for grains near interfaces to accommodate strain with twinning and slip modes consistent with conventionally produced zirconium alloys. Finally, mixtures of ductile and delamination-induced fracture highlight the interface-driven failure modes of UAM zirconium plate in the as-built condition. Graphic abstract

36 MATERIALS SCIENCE↗