The High Luminosity LHC interaction region magnets towards series production

The High Luminosity Large Hadron Collider (HL-LHC) is the new flagship project of CERN. First endorsed in 2013 and approved in 2016, HL-LHC is an upgrade of the accelerator aiming to increase by a factor of ten the statistics of the LHC collisions at the horizon of 2035-2040. HL-LHC relies on cutting edge technologies: among them, large aperture superconducting magnets will replace the present hardware to allow a smaller beam size in two interaction points (IPs). The project involves the construction of about 150 magnets of six different types: the quadrupole triplet, two main dipoles and three orbit correctors. The triplet, manufactured at CERN and in the USA, will consist of 30 magnets based on Nb3Sn technology, with an operational peak field of 11.4 T. These will be the first quadrupole Nb3Sn magnets installed in a particle accelerator. The other five types of magnets, all relying on Nb-Ti technology, present non-trivial challenges in the design and construction; they will be manufactured as part of in-kind contribution under the responsibility of institutes in Japan, China, Spain, and Italy. The project is now in the phase of transition between qualification through short models and prototypes and the beginning of the series construction. In this paper we review the magnet requirements, the reasons for selecting the design, the technological challenges with respect to previous projects, and we summarize the steps that have been taken to validate the baseline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for 14.4 keV solar axions from M1 transition of {sup 57}Fe with CUORE crystals

We report the results of a search for axions from the 14.4 keV M1 transition from {sup 57}Fe in the core of the sun using the axio-electric effect in TeO{sub 2} bolometers. The detectors are 5 × 5 × 5 cm{sup 3} crystals operated at about 10 mK in a facility used to test bolometers for the CUORE experiment at the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg⋅d of data was made using a newly developed low energy trigger which was optimized to reduce the energy threshold of the detector. An upper limit of 0.58 c⋅kg{sup −1}⋅d{sup −1} is established at 95% C.L., which translates into lower bounds f{sub A} ≥ 3.12 × 10{sup 5} GeV 95% C.L. (DFSZ model) and f{sub A} ≥ 2.41 × 10{sup 4} GeV 95% C.L. (KSVZ model) on the Peccei-Quinn symmetry-breaking scale, for a value of S = 0.5 of the flavor-singlet axial vector matrix element. These bounds can be expressed in terms of axion masses as m{sub A} ≤ 19.2 eV and m{sub A} ≤ 250 eV at 95% C.L. in the DFSZ and KSVZ models respectively. Bounds are given also for the interval 0.35 ≤ S ≤ 0.55.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics reach of the XENON1T dark matter experiment

The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in 1 tonne fiducial volume and (1, 12) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is (1.80 ± 0.15) · 10{sup −4} (kg·day·keV){sup −1}, mainly due to the decay of {sup 222}Rn daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region (4, 50) keV, is composed of (0.6 ± 0.1) (t·y){sup −1} from radiogenic neutrons, (1.8 ± 0.3) · 10{sup −2} (t·y){sup −1} from coherent scattering of neutrinos, and less than 0.01 (t·y){sup −1} from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency L{sub eff}, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a 2 y measurement in 1 t fiducial volume, the sensitivity reaches a minimum cross section of 1.6 · 10{sup −47} cm{sup 2} at m{sub χ} = 50 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Second Radio Synchrotron Background Workshop: Conference Summary and Report

We summarize the second radio synchrotron background workshop, which took place on 2022 June 15–17 in Barolo, Italy. This meeting was convened because available measurements of the diffuse radio zero level continue to suggest that it is several times higher than can be attributed to known Galactic and extragalactic sources and processes, rendering it the least well-understood electromagnetic background at present and a major outstanding question in astrophysics. The workshop agreed on the next priorities for investigations of this phenomenon, which include searching for evidence of the radio Sunyaev–Zel’dovich effect, carrying out cross-correlation analyses of radio emission with other tracers, and supporting the completion of the 310 MHz absolutely calibrated sky map project.

79 ASTRONOMY AND ASTROPHYSICS↗

Collisionless losses of fast ions in the Divertor Tokamak Test due to toroidal field ripple

In this paper we analyze fast ion motion in the Divertor Tokamak Test device. DTT is planned to be heated through a mix of 45 MW heating power, including 15 MW negative-ion-based Neutral Beam heating (NNBI) which is currently being developed by Consorzio RFX in Padova, Italy. An issue for DTT is that a Toroidal Field (TF) ripple with a maximum value of about 0.42% (with respect to the on-axis magnetic field $B_0$) is expected on the low-field side (LFS), and this ripple interacts with fast ions through rather well-known phenomena of ripple-precession resonances, in addition to prompt losses of ions which do not complete a full orbit in the poloidal plane. We will show that, with the planned geometry of NNBI, prompt losses are negligible, and ripple-precession losses amount to a maximum 0.15%. The calculations are performed with the guiding center code ORBIT using two different equilibria, and a beam with energy 400 keV and injection angle $\alpha_{inj} = 40^{\circ}$ (measured w.r.t. the first wall), which corresponds to a pitch of injected particles $\lambda = v_{\parallel}/v \approx \sin{\alpha_{inj}} = 0.65$. Main resonances are of the form $\omega_b - n N \omega_d = 0$, $\omega_b$ and $\omega_d$ being the bounce and precession frequency, respectively, $N=18$ the ripple periodicity and $3 \le n \le 6$ are the toroidal wavenumbers of the resonances. Although collisionless interaction with the TF ripple does not pose a serious threat to the NNBI project, an open question remains whether the presence of these resonances will interact with fast particles accelerated by \alfven eigenmodes, and if stochastization of the resonances is possible in DTT, as it was observed in the past in TORE SUPRA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conference Report on the 7th International Symposium on Liquid metals Applications for fusion (ISLA-7)

Supported by the world magnetic fusion research community, a series of International Symposia on Liquid metals Applications for fusion (ISLA) have been held biannually since 2010. The 7th edition (ISLA-7) was held for the period from 12 December through 16 December 2022, at Chubu University located in Kasugai, Aichi, Japan. For the first time in the history of this series of symposia, ISLA-7 was held in a hybrid fashion, due to the COVID-19 situation. The total number of the participants was 60, 34 out of whom attended the symposium in person, and the rest participated online. As to the presentation statistics, 29 papers were presented in person, whereas 21 presentations were delivered online but real-time by the presenters in China, Spain, the UK, and the USA. Both of the presentations delivered in person and online were recorded, and the video has been shared by all participants. These participants represent 11 countries: China, Czech, Italy, Japan, Latvia, Netherlands, Russia, Thailand, the UK, and the USA. All these numbers are among the largest in this series of symposia. Covered by these presentations are; in session-2, program overviews and liquid metal research review; in session-3, liquid metal flows, and MHD issues; in session-4, liquid metal facilities; in sessions-5 and 6, liquid metal experiments and modeling; in session-7, divertor physics and heat flux mitigation; in session-8, plasma and liquid metals interactions; in session-9 liquid metal plasma-facing components, erosion, and wettability. In addition, there were an opening session whereby several opening addresses were delivered and also a closing session where all technical session summaries were presented by the respective session chairs.

divertor↗

Conference Report on the 8th International Symposium on Liquid Metals Applications for Fusion (ISLA-8)

The International Symposium on Liquid Metals Applications for Fusion (ISLA) aims to assemble scientists and engineers engaged in research on lithium and liquid metal applications for fusion devices, facilitating discussions on recent advancements and challenges in an open forum to support the development of viable fusion reactors. The 8th International Symposium on Liquid Metals Applications for Fusion (ISLA-8) was organized by the Institute of Plasma Physics, Chinese Academy of Sciences, from 8 to 12 September 2024, in Hefei, China. The symposium was attended by over 70 participants, marking one of the highest attendance figures in the series. A total of 68 presentations were delivered, including 59 presented on-site, while the remainder were conducted online. The participants represented 10 countries, namely China, Japan, the Netherlands, Russia, the USA, the Czech Republic, Italy, Thailand, Spain, and Germany. The symposium covered 10 topics, structured into 13 sessions. Additionally, an opening session provided an overview of the current symposium, while a closing session summarized reports from each session chair.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron beam test of the large area Mu2e calorimeter prototype

The Mu2e calorimeter consists of 1348 pure CsI crystals coupled to two large area UV-extended Silicon Photomultipliers (SiPMs) organized in two separate annular disks. An intense R&D phase has been pursued to check if this configuration satisfies the Mu2e requirements. In May 2017, a dedicated test has been performed at the Beam Test Facility (BTF) in Frascati (Italy) where the large calorimeter prototype (Module-0) has been exposed to an electron beam in the energy range between 60 and 120 MeV. The prototype consists of 51 crystals, each one readout by two Mu2e SiPMs. We present results for timing and energy resolution both for electrons at normal incidence (0°) and at a grazing impact angle (50°) more similar to the experiment configuration. At 100 MeV, an energy resolution of 5.4% (7.4%) at normal (grazing) incidence has been achieved in good agreement with Monte Carlo expectation. In the same energy range, a time resolution of ~XX ps (~YY ps) has been measured at normal incidence with 1 GHz (250 MHz) sampling rate. Dependence of time and energy resolutions as a function of beam energy and impinging angle are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Monte Carlo simulation of the Borexino detector

Borexino is a 300 ton sub-MeV liquid scintillator solar neutrino detector which has been running at the Laboratori Nazionali del Gran Sasso (Italy) since 2007. Thanks to its unprecedented radio-purity, it was able to measure the flux of 7 Be, 8 B, pp, and pep solar neutrinos and to detect geo-neutrinos. A reliable simulation of the detector is an invaluable tool for all Borexino physics analyses. The simulation accounts for the energy loss of particles in all the detector components, the generation of the scintillation photons, their propagation within the liquid scintillator volume, and a detailed simulation of the electronics chain. A novel efficient method for simulating the external background which survives the Borexino passive shield was developed. This technique allows to reliably predict the effect of the contamination in the peripheral construction materials. The techniques developed to simulate the Borexino detector and their level of refinement are of possible interest to the neutrino and dark matter communities, especially for current and future large-volume liquid scintillator experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from the CUORE-0 experiment

The CUORE-0 experiment searched for neutrinoless double beta decay in 130 Te using an array of 52 tellurium dioxide crystals, operated as bolometers at a temperature of 10 mK. It took data in the Gran Sasso National Laboratory (Italy) since March 2013 to March 2015. We present the results of a search for neutrinoless double beta decay in 9.8 kg-years 130 Te exposure that allowed us to set the most stringent limit to date on this half-life. The performance of the detector in terms of background and energy resolution is also reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status and prospects for CUORE

CUORE is a cryogenic detector consisting of 988 TeO 2 crystals, 750 g each, and will be operated at a temperature of ~10 mK, to search for neutrinoless double beta decay (0νββ) of 130 Te. The detector, in the final stages of construction at the Laboratori Nazionali del Gran Sasso (Italy), will start its operations in 2016. CUORE-0, its pilot experiment, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach. CUORE-0 also made the most precise measurement of the 2νββ decay. The expected sensitivity of CUORE to the 0νββ 130 Te half-life is 9 •10 25 y, for 5 years of data taking. Here, we report the most recent results of CUORE-0, their implications for CUORE, and the current status of the CUORE experiment.

Canonica, L↗

Muon radiography applied to volcanoes imaging: the MURAVES experiment at Mt. Vesuvius

Muon radiography is a technique based on the measurement of absorption profiles of muons as they pass through matter. This measurement allows to obtain an image of the inner structure of large volume objects and is suitable to be applied in several fields, such as volcanology, archaeology and civil engeneering. One of the main applications concerns the study of volcanic structures; indeed it is possible to use this technique to measure the mass distribution inside the edifice of a volcano providing useful information to better understand the possible eruption mechanisms. The MURAVES (MUon RAdiography of VESuvius) project aims to the study of the summital cone of Mt. Vesuvius near Naples in Italy, one of the most dangerous active volcanoes in the world. The MURAVES apparatus is a modular, robust muon hodoscope system with a low power consumption, optimized to be used in inhospitable environments like the surroundings of volcanoes. The complete detection system is an array of identical tracking modules, each with an area of 1 m2, based on the use of plasic scintillators. The technologies, the status and the data analysis strategy of the experiment will be presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium β-decay endpoint. Here, we detail the implementation and optimization methods for successful operation of the filter for electrons with a known pitch angle. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to < 10 eV (< 1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratory (LNGS) in Italy.

47 OTHER INSTRUMENTATION↗

Erratum: Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Regretfully, the author list of the original paper did not contain the members of the groups being responsible for the HPGe screening, Radon emanation measurement and ICPMS surface characterization works. As the work performed is to be considered more than “just service work”, the authors together with the members of these groups have decided to amend the authors list. At publication the following authors were not included in the author list: • From Pacific Northwest National Laboratory, Richland, WA, U.S.A.: E.W. Hoppe, I.J. Arnquist, K.P. Hobbs, A.D. French, M.L. diVacri • From INFN, Laboratori Nazionali del Gran Sasso, 67100 Assergi, Italy: M. Laubenstein • From M. Smoluchowski Institute of Physics, Jagiellonian University, 30-348 Krakow, Poland: G. Zuzel The metadata of the present erratum are already correct.

99 GENERAL AND MISCELLANEOUS↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

DarkSide-20k (DS-20k) is a dark matter detection experimentunder construction at the Laboratori Nazionali del Gran Sasso (LNGS)in Italy. It utilises ∼ 100 t of low radioactivity argon from anunderground source (UAr) in its inner detector, with half serving astarget in a dual-phase time projection chamber (TPC). The UArcryogenics system must maintain stable thermodynamic conditionsthroughout the experiment's lifetime of over10 years. Continuous removal ofimpurities and radon from the UAr is essential for maximising signalyield and mitigating background. We are developing an efficient andpowerful cryogenics system with a gas purification loop with atarget circulation rate of1000 slpm. Central to itsdesign is a condenser operated with liquid nitrogen which is pairedwith a gas heat exchanger cascade, delivering a combined coolingpower of more than 8 kW. Here wepresent the design choices in view of the DS-20k requirements, inparticular the condenser's working principle and the coolingcontrol, and we show test results obtained with a dedicatedbenchmarking platform at CERN and LNGS. We find that the thermalefficiency of the recirculation loop, defined in terms of nitrogenconsumption per argon flow rate, is95 % and the pressure in the testcryostat can be maintained within±(0.1–0.2) mbar. Wefurther detail a 5-day cool-down procedure of the test cryostat,maintaining a cooling rate typically within-2 K/h, as required for theDS-20k inner detector. Additionally, we assess the circuit's flowresistance, and the heat transfer capabilities of two heat exchangergeometries for argon phase change, used to provide gas forrecirculation. We conclude by discussing how our findings influencethe finalisation of the system design, including necessarymodifications to meet requirements and ongoing testing activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.